Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

Performance Evaluation of Decontamination Foam Containing Mesoporous silica NPs - 18453

It is necessary to secure decontamination technology that is easy to apply and minimizes the generation of secondary waste for large-scale equipment and large-area decontamination, which are difficult to be applied structurally when massive repairs or the decommissioning of a nuclear facility are required. In this respect, decontamination foam has a potentially wide application in the removal of contaminants from metallic walls, overhead surfaces, and elements of complex components and facilities. The decontamination efficiency can be enhanced by improving the contact time between the chemical decontamination agents and the contaminated surface through the introduction of stabilizers into the decontamination foam. In this study, the stability of a decontamination foam containing mesoporous silica NPs as a stabilizer and the decontamination performance of radioactive isotope contaminated specimens were evaluated. A process for waste liquid treatment after foam decontamination was also proposed. Decontamination performance tests using RI contaminated specimens were carried out in a decontamination foam prepared only with a solution containing only 1 wt% EM100 surfactant, and in a decontamination foam prepared with a solution containing 1 wt% EM100 surfactant and 1 wt% of various silica NPs. The stability of the decontamination foam was increased owing to the addition of various types of silica NPs. In particular, the liquid film thickness of the decontamination foam containing mesoporous silica NPs was the largest. As a result, the decontamination coefficient for RI contaminated specimens increased as the thickness of the foam liquid film increased owing to the longer contact time between the RI contaminated specimen and the chemical decontamination agent as the thickness of the foam liquid film increased. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Yield Estimates for Nuclear Detonations Over Water

One of the primary methods used by the United States to estimate the yields of atmospheric nuclear tests performed in the 1940’s, 50’s, and 60’s was to film each detonation with a high-speed camera, measure the blast radius as a function of time, and then use Taylor’s spherical blast wave equation to calculate the source energy (i.e., the yield). For surface detonations, the yield in Taylor’s equation was assumed to be twice as large as the actual yield to account for the energy reflected from the surface, assuming the ground was a perfect reflector. Recent simulations of surface detonations over water (referred to as barge shots) have shown that Taylor’s equation must be modified further to account for material entrainment and heat losses. We have computed this lost energy using a high-order radiation-hydrodynamics code to determine the reduction in blast radius vs. time. By analyzing simulation data in the same manner as film data, we have determined that a yield correction factor of 1.27± 0.04 should be applied to the barge shots.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Power Curve Working Group's assessment of wind turbine power performance prediction methods

Wind turbine power production deviates from the reference power curve in real-world atmospheric conditions. Correctly predicting turbine power performance requires models to be validated for a wide range of wind turbines using inflow in different locations. The Share-3 exercise is the most recent intelligence-sharing exercise of the Power Curve Working Group, which aims to advance the modeling of turbine performance. The goal of the exercise is to search for modeling methods that reduce error and uncertainty in power prediction when wind shear and turbulence digress from design conditions. Herein, we analyze data from 55 wind turbine power performance tests from nine contributing organizations with statistical tests to quantify the skills of the prediction-correction methods. We assess the accuracy and precision of four proposed trial methods against the baseline method, which uses the conventional definition of a power curve with wind speed and air density at hub height. The trial methods reduce power-production prediction errors compared to the baseline method at high wind speeds, which contribute heavily to power production; however, the trial methods fail to significantly reduce prediction uncertainty in most meteorological conditions. For the meteorological conditions when a wind turbine produces less than the power its reference power curve suggests, using power deviation matrices leads to more accurate power prediction. We also determine that for more than half of the submissions, the data set has a large influence on the effectiveness of a trial method. Overall, this work affirms the value of data-sharing efforts in advancing power curve modeling and establishes the groundwork for future collaborations.

17 WIND ENERGY↗

Correlations of Capacitance-Voltage Hysteresis with Thin-Film CdTe Solar Cell Performance During Accelerated Lifetime Testing

In this paper we present the correlation of CdTe solar cell performance with capacitance-voltage hysteresis, defined presently as the difference in capacitance measured at zero-volt bias when collecting such data with different pre-measurement bias conditions. These correlations were obtained on CdTe cells stressed under conditions of 1-sun illumination, open-circuit bias, and an accelerationtemperature of approximately 100 degrees C.

14 SOLAR ENERGY↗

Awe Bonner sphere measurements of the neutron leakage spectrum from the GODIVIA-IV critical assembly at NCERC - 14413

The US National Criticality Experiments Research Centre (NCERC) is home to several critical assembly machines that were relocated from Los Alamos National Laboratory in the last decade. The centre is sponsored by the Department of Energy's Nuclear Criticality Safety Program (NCSP), which has the mission to ensure the safe handling of fissile materials from a criticality perspective. Under the auspices of the NCSP, Lawrence Livermore National Laboratory (LLNL) is planning to host an international inter-comparison of nuclear accident dosimetry (NAD) using the Godiva-IV assembly at NCERC. The inter-comparison is motivated by a decline in the frequency of performance testing of NADs (both in the US, the UK and France) and the desire to modernize and harmonize dosimetry systems. A pre-requisite for the inter-comparison is the characterisation of the neutron and gamma-ray leakage spectra associated with the Godiva-IV assembly at NCERC. AWE provided its Bonner-sphere spectrometry capability to LLNL for two experimental campaigns, in November 2013 and May 2014, to measure the neutron leakage spectrum of the assembly in both a sub-critical 'steady-state' and a super-prompt-critical 'burst'. Nine points, at distances from 2 to 4 meters from the machine were measured with the Bonner-sphere spectrometer using both an active He-3 detector and a passive technique employing gold foils. This paper presents the spectra unfolded from the data and integral dose values, and compares these to previously published data. The limitations of the work and future plans are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ANNULUS CLOSURE TECHNOLOGY DEVELOPMENT INSPECTION/SALT DEPOSIT CLEANING MAGNETIC WALL CRAWLER

The Liquid Waste Technology Development organization is investigating technologies to support closure of radioactive waste tanks at the Savannah River Site (SRS). Tank closure includes removal of the wastes that have propagated to the tank annulus. Although amounts and types of residual waste materials in the annuli of SRS tanks vary, simple salt deposits are predominant on tanks with known leak sites. This task focused on developing and demonstrating a technology to inspect and spot clean salt deposits from the outer primary tank wall located in the annulus of an SRS Type I tank. The Robotics, Remote and Specialty Equipment (RRSE) and Materials Science and Technology (MS&T) Sections of the Savannah River National Laboratory (SRNL) collaborated to modify and equip a Force Institute magnetic wall crawler with the tools necessary to demonstrate the inspection and spot cleaning in a mock-up of a Type I tank annulus. A remote control camera arm and cleaning head were developed, fabricated and mounted on the crawler. The crawler was then tested and demonstrated on a salt simulant also developed in this task. The demonstration showed that the camera is capable of being deployed in all specified locations and provided the views needed for the planned inspection. It also showed that the salt simulant readily dissolves with water. The crawler features two different techniques for delivering water to dissolve the salt deposits. Both water spay nozzles were able to dissolve the simulated salt, one is more controllable and the other delivers a larger water volume. The cleaning head also includes a rotary brush to mechanically remove the simulated salt nodules in the event insoluble material is encountered. The rotary brush proved to be effective in removing the salt nodules, although some fine tuning may be required to achieve the best results. This report describes the design process for developing technology to add features to a commercial wall crawler and the results of the demonstration testing performed on the integrated system. The crawler was modified to address the two primary objectives of the task (inspection and spot cleaning). SRNL recommends this technology as a viable option for annulus inspection and salt removal in tanks with minimal salt deposits (such as Tanks 5 and 6.) This report further recommends that the technology be prepared for field deployment by: (1) developing an improved mounting system for the magnetic idler wheel, (2) improving the robustness of the cleaning tool mounting, (3) resolving the nozzle selection valve connections, (4) determining alternatives for the brush and bristle assembly, and (5) adding a protective housing around the motors to shield them from water splash. In addition, SRNL suggests further technology development to address annulus cleaning issues that are apparent on other tanks that will also require salt removal in the future such as: (1) Developing a duct drilling device to facilitate dissolving salt inside ventilation ducts and draining the solution out the bottom of the ducts. (2) Investigating technologies to inspect inside the vertical annulus ventilation duct.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient Testing of Nuclear Fuels Performed in the Original Operation of TREAT, Third Edition

TREAT core was upgraded at the end of the 1980s. The tests performed since about 1970 are summarized in considerable detail. Earlier tests are noted by their designated series and by some parameters that help to identify and distinguish each series from the others. The detailed summary descriptions are intended to help inform future researchers regarding the large, historical, empirical data base generated from that 35-year span during which hundreds of TREAT experiments were performed to investigate and demonstrate the transient behavior of a wide variety of nuclear fuels during severe off-normal and accident conditions -- using direct nuclear heating of the test samples. That empirical basis is foundational and valuable for guiding future qualification and safety evaluation of improved fuel designs and for future transient test planning and performance in TREAT. The second edition of this report added descriptions of the following test series: D, E, EOS, F, H, J, R, RX, and S. This third edition includes descriptions of an additional four test series: the HUT, HOP (& HUC), ORNL-TR, and PNL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On-Demand Designing of Cathode Internal Surface Architecture for Dramatic Enhancement of SOFC Performance and Durability

This project is aimed to design and modify the internal surfaces of porous composite cathode from currently commercially viable Solid Oxide Fuel Cells (SOFCs), using additive manufacturing process of Atomic Layer Deposition (ALD). The material systems being investigated are commercial composite electrodes complex three-dimensional topographies. In term of the chemistry of the ALD layer applied on the internal surface of the porous cathode, this project has employed commercially relevant electrolyte, electrocatalyst and noble metal materials set. Such materials are fully compatible with the commercial fuel cells, and this project has developed special nanostructure on the surface of the commercial composite cathodes. The formation of the designed nanoarchitecture on the surface of SOFC cathode has been achieved through precise control of ALD parameters and their effect on overall cell performance and resultant electrochemical reaction mechanism of cathodes has been investigated through full cell electrochemical performance testing and nanostructure characterization by transmission electron microscopy (TEM). Under the support of this award, following has been achieved: (1). For cathode materials in solid oxide fuel cells (SOFCs), such as perovskite mixed conductor La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-x (LSCF), cation surface segregation and consequently losing conductivity and active sites for the oxygen reduction reaction (ORR) are problematic. To mitigate the cation segregation and enhance SOFC durability, further decorating the internal backbone surface using the desired electrocatalysts could be a promoting approach. Commonly, the cation segregation such as Sr is very volatile, so the effective surface decoration is ideally conformal. Nevertheless, the conformal surface coating would inevitably alter the ORR pathways that initially take place on the surface of the backbone. To reveal the impact of the conformal coating on both the catalytic activity and the conductivity of the cathode, the unary electrocatalyst of Pt or CoO x , was applied to the LSCF/SDC composite electrode of inherently functional SOFCs, respectively. Both ALD coating layers evolve strong interaction with the LSCF composite cathode. Upon operations, the Pt coating layer remains conformal on LSCF grain surfaces but turns into discrete particles on SDC grain surfaces. Meanwhile, CoO x conformal coating grows to be the discrete nanograins on both the LSCF and SDC grains. ALD coating of the cathode alone reduces the ohmic resistance up to 28 % for the entire cells. The increased conductivity induced by the ALD coating of Pt or CoO x is ascribed to different mechanisms. For the inherent functional SOFCs, the present study presents a novel and feasible approach to apply a conformal, dense coating layer on the surface of a mixed conductor, simultaneously increasing the conductivity and durability of the SOFC cathode. (2). High resistance of the oxygen electrode still significantly hinders the state-of-the-art Solid Oxide Fuel Cells (SOFCs). In particular, for an oxygen electrode consisting of mixed electronic and ionic conductors, such as perovskite lanthanum strontium cobalt ferrite (LSCF), it deteriorates due to its low chemical stability of the grain surface. Such degradation is often associated with the segregation of cations. To prevent the cation surface segregation and its resultant perovskite phase decomposition, we demonstrate a conformal ultra-thin (7-10 nm) surface heterogeneous coating layer consisting of subjacent discrete Pt nanoparticles capped with a superjacent fully dense conformal CoO x layer. The performance studies indicate the ALD coating reduces the cell series resistance by up to 40 %. The conformal CoO x layer consists of randomly orientated but single-layered nanograins, with high-density intergranular and surface grain boundaries serving as the electrochemical reaction sites and facilitating mass transport. The conformal coating layer appears to have successfully suppressed the Sr outward diffusion and confined the Sr enriched layer to a ~ 2 nm interface perovskite phase between the coating layer and the LSCF grain surface. Moreover, this ultra-thin Sr enriched perovskite layer presumably possesses high oxygen vacancy and high ionic conductivity and further imposes tensile strain to the LSCF grain surfaces. With the combination of a conformal CoO x nanoionics, Sr enriched layer, and its strained interface, the ALD coating induced surface layer is estimated to have a conductivity of ~ 1.27x10 4 S/cm, which is over two orders magnitude of that from LSCF at 750 ºC.

30 DIRECT ENERGY CONVERSION↗

Annual report of groundwater monitoring at Everest, Kansas in 2011

Everest, Kansas, is a small rural community (population approximately 300) located in the southeast corner of Brown County, in the northeastern corner of Kansas. Carbon tetrachloride and chloroform contamination in groundwater at Everest was initially identified in 1997 as a result of testing performed under the Commodity Credit Corporation/U.S. Department of Agriculture (CCC/USDA) private well sampling program conducted by the Kansas Department of Health and Environment (KDHE). The KDHE collected samples from seven private wells in and near Everest. Carbon tetrachloride and chloroform were found in only one of the wells, the Donnie Nigh domestic well (owned at that time by Tim Gale), approximately 3/8 mi northwest of the former Everest CCC/USDA facility. Carbon tetrachloride and chloroform were detected at 121 {mu}g/L and 4 {mu}g/L, respectively. Nitrate was found at 12.62 mg/L. The USDA subsequently connected the Nigh residence to the Everest public water supply system. The findings of the 2011 monitoring at Everest support the following conclusions: (1) Measurements of groundwater levels obtained manually during annual monitoring in 2009-2011 (and through the use of automatic recorders in 2002-2010) have consistently indicated an initial direction of groundwater flow from the former CCC/USDA facility to the north-northwest and toward the Nigh property, then west-southwest from the Nigh property toward the intermittent creek that lies west of the former CCC/USDA facility and the Nigh property. (2) At most of the monitored locations, carbon tetrachloride concentrations decreased in April 2011 relative to 2010 results. Noteworthy decreases of > 50% occurred at locations MW4, MW60, and MW88, in the most concentrated part of the plume. (3) Comparison of accumulated data demonstrates that the area of the carbon tetrachloride plume with concentrations > 200 {mu}g/L has decreased markedly over time and suggests a generally decreasing trend in contaminant levels. (4) The trace increases in carbon tetrachloride concentrations observed in 2010 at locations SB63 and SB64 were notable because of the locations proximity to the downgradient intermittent creek. However, these increases were not confirmed in sampling in 2011. (5) The results of the April 2011 monitoring event continue to support the interpretation, made during the 9-yr observation period from 2001 to 2010, that the migration rate for contamination in groundwater toward the intermittent creek is very slow. (6) No carbon tetrachloride was detected in five samples of surface water collected from the intermittent creek west of the former CCC/USDA facility and the Nigh property, or in tree branch tissue samples collected at locations along the banks of the creek. These observations indicate that the carbon tetrachloride contamination identified at Everest has, to date, not impacted the surface waters of the intermittent creek.

54 ENVIRONMENTAL SCIENCES↗

Design and experimental testing of the performance of an outdoor LiBr/H{sub 2}O solar thermal absorption cooling system with a cold store

A domestic-scale prototype experimental solar cooling system has been developed based on a LiBr/H{sub 2}O absorption system and tested during the 2007 summer and autumn months in Cardiff University, UK. The system consisted of a 12 m{sup 2} vacuum tube solar collector, a 4.5 kW LiBr/H{sub 2}O absorption chiller, a 1000 l cold storage tank and a 6 kW fan coil. The system performance, as well as the performances of the individual components in the system, were evaluated based on the physical measurements of the daily solar radiation, ambient temperature, inlet and outlet fluid temperatures, mass flow rates and electrical consumption by component. The average coefficient of thermal performance (COP) of the system was 0.58, based on the thermal cooling power output per unit of available thermal solar energy from the 12 m{sup 2} Thermomax DF100 vacuum tube collector on a hot sunny day with average peak insolation of 800 W/m{sup 2} (between 11 and 13.30 h) and ambient temperature of 24 C. The system produced an electrical COP of 3.6. Experimental results prove the feasibility of the new concept of cold store at this scale, with chilled water temperatures as low as 7.4 C, demonstrating its potential use in cooling domestic scale buildings. (author)

14 SOLAR ENERGY↗

Sealing of fractures in a representative CO 2 reservoir caprock by migration of fines

The impact of fines migration on fracture transmissivity reduction was investigated by injecting a brine solution containing a suspension of 0.1 wt. % kaolinite particles with a mean particle size distribution of 9.6 µm through fractured shale core samples. The fractures had apertures estimated to be approximately 100 µm. A mass balance approach was used to determine the quantity of kaolinite that was deposited within the fractures (influent – effluent = amount deposited in fractures). Large fractions (44 to 90%) of the suspended kaolinite pumped through the fractures were deposited within the fractures. Based on fracture volumes estimated with X-ray computed tomography, it was determined that approximately 10 to 17% of the fracture volume was filled with kaolinite at the point when flow was completely restricted. These results indicate that 100 µm fractures in CO 2 reservoir caprocks could be sealed within hours if the brines passing through the fractures contain a proportional volume of particulates to the tests performed in this laboratory study.

04 OIL SHALES AND TAR SANDS↗

Modeling soil respiration and variations of source components using a multi-factor global climate change experiment

Soil respiration is an important component of the global carbon cycle and is highly responsive to changes in soil temperature and moisture. Accurate prediction of soil respiration and its changes under future climatic conditions requires a clear understanding of the processes involved. In spite of this, most current empirical soil respiration models incorporate just few of the underlying mechanisms that may influence its response. In this study, a new partial process-based component model built on source components of soil respiration was tested using data collected from a multi-factor climate change experiment that manipulates CO2 concentrations, temperature and precipitation. These results were then compared to results generated using several other established models. The component model we tested performed well across different treatments of global climate change. In contrast, some other models, which worked well predicting ambient environmental conditions, were unable to predict the changes under different climate change treatments. Based on the component model, the relative proportions of heterotrophic respiration (Rh) in the total soil respiration at different treatments varied from 0.33 to 0.85. There is a significant increase in the proportion of Rh under the elevated atmospheric CO2 concentration in comparison ambient conditions. The dry treatment resulted in higher proportion of Rh at elevated CO2 and ambient T than under elevated CO2 and elevated T. Also, the ratios between root growth and root maintenance respiration varied across different treatments. Neither increased temperature nor elevated atmospheric CO2 changed Q10 values significantly, while the average Q10 value at wet sites was significantly higher than it at dry sites. There was a higher possibility of increased soil respiration under drying relative to wetting conditions across all treatments based on monthly data, indicating that soil respiration may also be related to soil moisture at previous time periods. Our results reveal that the extent, time delay and contribution of different source components need to be included into mechanistic/processes-based soil respiration models at corresponding scale.

54 ENVIRONMENTAL SCIENCES↗

Coupled thermal stress simulations of ductile tearing

Predictions for ductile tearing of a geometrically complex Ti-6Al-4V plate were generated using a Unified Creep Plasticity Damage model in fully coupled thermal stress simulations. Uniaxial tension and butterfly shear tests performed at displacement rates of 0.0254 and 25.4 mm/s were also simulated. Results from these simulations revealed that the material temperature increase due to plastic work can have a dramatic effect on material ductility predictions in materials that exhibit little strain hardening. Furthermore, this occurs because the temperature increase causes the apparent hardening of the material to decrease which leads to the initiation of deformation localization and subsequent ductile tearing earlier in the loading process.

36 MATERIALS SCIENCE↗

A Combined Experimental-Computational Confirmation of the Seismic Stability of the Branched Pipelines of Systems of Nuclear Power Stations

The increase in the extent and degree of complication of the geometry of the branched pipelines of nuclear power stations has led to the appearance of natural forms of vibrations with frequencies that cannot be determined by the traditional combined experimental-computational method. This has made it necessary to develop new approaches to the experimental determination of the dynamic characteristics and to the selection of the boundaries of the design plans. Through use of the proposed correction to the technique and algorithm used in the estimation of the seismic stability of pipelines it has been possible to increase the precision with which the lowest frequencies of the natural vibrations are determined and, in certain cases, to also reduce the volume of operations through “targeted” testing performed at sites of expected maximal amplitudes of the lowest forms of vibrations.

42 ENGINEERING↗

The sapphire backscattering monochromator at the Dynamics beamline P01 of PETRA III

Here, we report on a high resolution sapphire backscattering monochromator installed at the Dynamics beamline P01 of PETRA III. The device enables nuclear resonance scattering experiments on M ossbauer isotopes with transition energies between 20 and 60 keV with sub-meV to meV resolution. In a first performance test with 119 Sn nuclear resonance at a X-ray energy of 23.88 keV an energy resolution of 1.34 meV was achieved. Moreover, the device extends the field of nuclear resonance scattering at the PETRA III synchrotron light source to many further isotopes like 151 Eu, 149 Sm, 161 Dy, 125 Te and 121 Sb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Thin Film Composite Nanofiltration Membrane Using Monoethanolamine (MEA) and Diethanolamine (DEA) with m-Phenylenediamine (MPD)

A novel thin-film composite (TFC) nanofiltration membrane was prepared by interfacial polymerization of polyamide layer on a polyethersulfone support, using monoethanolamine (MEA) and diethanolamine (DEA) with m-phenylenediamine as monomers and trimesoyl chloride (TMC) as crosslink agent. The membrane surface before and after using aminoalcohol monomers (MEA and DEA) was investigated in detail using ATR-FTIR, TGA, AFM and SEM. The AFM and SEM images showed that addition of MEA and DEA had a strong impact on surface morphology. The polyamide layer thickness of control and modified TFC membranes based on MEA and DEA were calculated to be in 180–230 nm range and the mean pore sizes were about 0.35–1.2 nm. The RO performance tests indicated that addition of MEA and DEA can increase the NaCl and Na{sub 2}SO{sub 4} rejection remarkably with little decline in the pure water permeation flux.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Coupled Processes Modeling in Rock Salt and Crushed Salt Including Halite Solubility Constraints: Application to Disposal of Heat-Generating Nuclear Waste

This work presents numerical modeling of coupled thermal, hydraulic and mechanical processes in rock salt and crushed salt considering halite solubility constraints. The TOUGH-FLAC simulator is used, with a recently enhanced Equation-Of-State module that includes the thermodynamic properties of aqueous fluids of variable salinity. Laboratory and field scale tests performed on rock salt and crushed salt under temperature gradients are modeled first to evaluate the capabilities of the simulator to reproduce important features, such as porosity changes induced by halite dissolution/precipitation, and brine and heat migration. Since the results are quite satisfactory, the simulator is used to predict the long-term response of a generic salt repository for heat-generating nuclear waste. To evaluate the impacts of halite solubility on the predictions, two simulations that respectively consider or neglect solubility constraints are performed. In the scenario studied, the results are not significantly affected by dissolution/precipitation, and only some differences are observed due to changes in porosity, but the dominating processes remain the same. Finally, with the new provisions, TOUGH-FLAC is more complete in terms of processes occurring around a heat-releasing nuclear waste package and can therefore provide more accurate predictions of the long-term performance of a nuclear waste repository in salt formations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗