Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Quantifying Resolution Implications for Agent-based Distributed Energy Resource Customer Adoption Models

In this report we explore tradeoffs of top-down and bottom-up methods in their precision and computational burden using NREL's dGen model, an agent-based model of residential and non-residential distributed PV adoption. In particular, we assess the role of agent resolution in instantiating statistically-representative populations in the model--and the resulting variance of model projections at the state, sector and county levels. Running the model for a single state with fixed macroeconomic assumptions, we vary both the number of agents instantiated and the number of unique simulations. Notably, in each run we introduce sources of uncertainty in cumulative DPV adoption results during agent instantiation as we stochastically sample agent attributes from localized building characteristic and solar resource distributions. We find three key trends which guide what can be expected of results. First, precision of the model projections, as measured by the variance of the unique simulations increased as a function of the number of agents sampled, though with diminishing returns to scale. The result is expected given the Law of Large Numbers. Second, the mean or expected value of projections decreased as the number of agents instantiated increased. Empirically, aggregate DPV capacities projected by dGen are 7% lower on average at a 10-agent resolution compared to 1-agent resolutions, and up to 10% lower in the non-residential sector. We attribute this outcome to a system sizing scheme that biases lower cumulative installed capacity as agent resolution increases when roof size and load are not positively correlated. Finally, the variance of model projections differed by sector, where variance was substantially larger in the commercial sector, largely due to differences in parameterization by sector. We explain the larger variance in the non-residential sector as an outcome of the greater variance in building uses and load shapes as compared to the residential sector, and we find that a resolution on the order of 100-agents per county would be necessary to bring non-residential variance in line with residential variance at a 2-agent resolution. We propose that further research explore increasing precision and agent resolution in the non-residential sector. Moreover, given that days of intensive computing may be required to resolve a suitable estimate even at the extent of a single state within acceptable levels of precision, to promote computational efficiency we also suggest more clearly quantifying sources of variability at the county level such that resolution can by dynamically increased where county level results are least precise.

14 SOLAR ENERGY↗

Photovoltaic Shading Testbed for Module-Level Power Electronics

This document describes a repeatable test procedure that attempts to simulate shading situations, as would be experienced by typical residential rooftop photovoltaic (PV) systems. This type of shading test is particularly useful to evaluate the impact of different power conversion setups, including microinverters, DC power optimizers and string inverters, on overall system performance. Theperformance results are weighted based on annual estimates of shade to predict annual performance improvement. A trial run of the test procedure was conducted with a side by side comparison of a string inverter with a microinverter, both operating on identical 8kW solar arrays. Considering three different shade weighting conditions, the microinverter was found to increase production by 3.7%under light shading, 7.8% under moderate shading, and 12.3% under heavy shading, relative to the reference string inverter case. Detail is provided in this document to allow duplication of the test method at different test installations and for different power electronics devices.

14 SOLAR ENERGY↗

Solar dynamic power for space station freedom

The Space Station Freedom Program is presently planned to consist of two phases. At the completion of Phase 1, Freedom's manned base will consist of a transverse boom with attached manned modules and 75 kW of available electric power supplied by photovoltaic (PV) power sources. In Phase 2, electric power available to the manned base will be increased to 125 kW by the addition of two solar dynamic (SD) power modules, one at each end of the transverse boom. Power for manned base growth beyond Phase 2 will be supplied by additional SD modules. Studies show that SD power for the growth eras will result in life cycle cost savings of $3 to $4 billion when compared to PV-supplied power. In the SD power modules for Space Station Freedom, an offset parabolic concentrator collects and focuses solar energy into a heat receiver. To allow full power operation over the entire orbit, the receiver includes integral thermal energy storage by means of the heat of fusion of a salt mixture. Thermal energy is removed from the receiver and converted to electrical energy by a power conversion unit (PCU) which includes a closed brayton cycle (CBC) heat engine and an alternator. The receiver/PCU/radiator combination will be completely assembled and charged with gas and cooling fluid on Earth before launch to orbit. The concentrator subassemblies will be pre-aligned and stowed in the orbiter bay before launch. On orbit, the receiver/PCU/radiator assembly will be installed as a unit. The pre-aligned concentrator panels will then be latched together and the total concentrator attached to the receiver/PCU/radiator by the astronauts. After final electric connections are made and checkout is complete, the SD power module will be ready for operation.

Labus, Thomas L.↗

Solar dynamic power for Space Station Freedom

The Space Station Freedom Program is presently planned to consist of two phases. At the completion of Phase 1, Freedom's manned base will consist of a transverse boom with attached manned modules and 75 kW of available electric power supplied by photovoltaic (PV) power sources. In Phase 2, electric power available to the manned base will be increased to 125 kW by the addition of two solar dynamic (SD) power modules, one at each end of the transverse boom. Power for manned base growth beyond Phase 2 will be supplied by additional SD modules. Studies show that SD power for the growth eras will result in life cycle cost savings of $3 to $4 billion when compared to PV-supplied power. In the SD power modules for Space Station Freedom, an offset parabolic concentrator collects and focuses solar energy into a heat receiver. To allow full power operation over the entire orbit, the receiver includes integral thermal energy storage by means of the heat of fusion of a salt mixture. Thermal energy is removed from the receiver and converted to electrical energy by a power conversion unit (PCU) which includes a closed brayton cycle (CBC) heat engine and an alternator. The receiver/PCU/radiator combination will be completely assembled and charged with gas and cooling fluid on earth before launch to orbit. The concentrator subassemblies will be pre-aligned and stowed in the orbiter bay before launch. On orbit, the receiver/PCU/radiator assembly will be installed as a unit. The pre-aligned concentrator panels will then be latched together and the total concentrator attached to the receiver/PCU/radiator by the astronauts. After final electric connections are made and checkout is complete, the SD power module will be ready for operation.

Labus, Thomas L.↗

1366 Project Silicon: Reclaiming US Silicon PV Leadership

1366 Technologies’ Project Silicon addresses two of the major goals of the DOE’s PV Manufacturing Initiative Part 2 program: 1) How to reclaim a strong silicon PV manufacturing presence and; 2) How to lower the levelized cost of electricity (“LCOE”) for solar to $0.05-$0.07/kWh, enabling wide-scale U.S. market adoption. To achieve these two goals, US companies must commercialize disruptive, high-value technologies that are capable of rapid scaling, defensible from foreign competition, and suited for US manufacturing. These are the aims of 1366 Technologies Direct Wafer ™ process. The research conducted during Project Silicon led to the first industrial scaling of 1366’s Direct Wafer™ process – an innovative, US-friendly (efficient, low-labor content) manufacturing process that destroys the main cost barrier limiting silicon PV cost-reductions: the 35-year-old grand challenge of making quality wafers (40% of the cost of modules) without the cost and waste of sawing. The SunPath program made it possible for 1366 Technologies to build its demonstration factory, a key and critical step in the Company’s evolution. The demonstration factory allowed 1366 to build every step of the process flow at production size, eliminating potential risk and ensuring the success of the Company’s subsequent scaling for a 1 GW factory to be constructed in Western New York in 2016 and 2017. Moreover, the commercial viability of the Direct Wafer process and its resulting wafers were established as 1366 formed key strategic partnerships, gained entry into the $8B/year multi-Si wafer market, and installed modules featuring Direct Wafer products – the veritable proving grounds for the technology. The program also contributed to the development of three Generation 3 Direct Wafer furnaces. These furnaces are the platform for copying intelligently and preparing our supply chain – large-scale expansion will not require a bigger machine but more machines. SunPath filled the crucial development step between the original research effort in Lexington and the GW factory scheduled to be online before the end of the decade. At the conclusion of the project, it is clear that the Direct Wafer™ technology will have a dramatic impact on the entire silicon photovoltaic supply chain by effectively doubling existing silicon capacity (by reducing silicon usage by 50%) and reducing supply chain capital costs by 35%. The technology, when fully-scaled in the US, will also lead to significant job growth, with the eventual creation of 1,000 jobs in Western New York.

14 SOLAR ENERGY↗

Utility-Scale Solar Data Update (2020 Edition) [Slides]

Berkeley Lab’s 2020 update of utility-scale solar data and trends provides an overview of key trends in the U.S. market, with a focus on 2019. Highlights of this year’s update include: More than 4.5 GWAC of utility-scale solar (i.e., ground-mounted solar projects larger than 5 MWAC) achieved commercial operations in 2019, bringing cumulative capacity to 29 GWAC. Projects are spread across all 10 regions that we track, though more heavily concentrated in the sunniest regions. The median installed cost of projects that came online in 2019 fell to $\$$1.4/WAC ($\$$1.2/WDC), down 20% from 2018 and down by more than 70% from 2010. 77% of projects and 88% of capacity added in 2019 used single-axis tracking. Average capacity factors range from 17% in the least-sunny regions to 30% where it is sunniest. Single-axis tracking adds roughly five percentage points to capacity factor in the regions with the strongest solar resource. Nationwide average levelized power purchase agreement (PPA) prices fell to $\$$24/MWh in 2019, down 17% from 2018 and more than 80% since 2010. Thirty-nine projects (totaling 4.2 GWAC) in our PPA price sample include battery storage (totaling 2.3 GWAC and 9.5 GWh). In the “lower 48” states, a number of these recent PV+battery PPAs have been inked in the mid-$\$$20/MWh range (levelized in 2019 dollars).Not including the 30% investment tax credit (ITC), the median levelized cost of energy (LCOE) from utility-scale PV has declined by 85% since 2010, to $\$$40/MWh in 2019. When the 30% ITC is included within the LCOE calculation, the median LCOE closely tracks the median PPA price over time. In higher-penetration markets like CAISO, the value of solar has been declining, but falling PPA prices have largely kept pace, preserving solar's net value. At the end of 2019, there were nearly 370 GW of solar in interconnection queues from all 7 ISOs and 30 additional utilities across the country. Nearly a third of this proposed solar capacity is paired with battery storage.

14 SOLAR ENERGY↗

Reliability and performance experience with flat-plate photovoltaic modules

Statistical models developed to define the most likely sources of photovoltaic (PV) array failures and the optimum method of allowing for the defects in order to achieve a 20 yr lifetime with acceptable performance degradation are summarized. Significant parameters were the cost of energy, annual power output, initial cost, replacement cost, rate of module replacement, the discount rate, and the plant lifetime. Acceptable degradation allocations were calculated to be 0.0001 cell failures/yr, 0.005 module failures/yr, 0.05 power loss/yr, a 0.01 rate of power loss/yr, and a 25 yr module wear-out length. Circuit redundancy techniques were determined to offset cell failures using fault tolerant designs such as series/parallel and bypass diode arrangements. Screening processes have been devised to eliminate cells that will crack in operation, and multiple electrical contacts at each cell compensate for the cells which escape the screening test and then crack when installed. The 20 yr array lifetime is expected to be achieved in the near-term.

Ross, R. G., Jr.↗

Energy Paths for the Yurok People

This Yurok Tribe energy strategic planning study examined electricity usage, costs and infrastructure, as well as electricity needs on the Reservation. It also assessed the Tribe’s energy resources. Equipped with this information, the project team conducted an energy options analysis that examined different project opportunities and identified key projects that are both feasible to implement and will help the Tribe reach its stated Energy Vision. A key finding of the energy needs assessment is that there are still numerous households that are without grid electric power, and it is likely that most of them will remain disconnected from the grid because of their remoteness. To provide these community members with reliable, affordable, modern energy services their homes will need to be electrified via a robust off-grid energy services program that installs and maintains off-grid energy systems. This is the key need that is explored and addressed in this plan. The approach taken is to establish a new business entity, a Tribal Energy Authority or Utility, that will operate a Tribal Energy Program. The Energy Strategic Plan identifies a number of potential funding sources that could be used to support both the On-grid and Off-grid Energy Programs. This plan also promotes continued efforts to reduce electricity consumption through the implementation of energy efficiency measures in existing facilities and the enforcement of a strong energy-efficient building code for all new construction on the Reservation. Finally, the plan promotes added resilience at critical Tribal facilities on the Reservation by recommending that battery energy storage systems and microgrid controls be coupled with rooftop solar PV systems to create cutting edge microgrid facilities that can provide critical power services to Tribal facilities when the main electric grid is shutdown.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Case Study Analysis of U.S. Policy Solutions to Enable China New Energy Cities

This report summarizes various policies for encouraging investment and installation of renewable energy across the country. In particular, we attempt to explain the benefits of, and considerations behind, each policy type and provide examples of implementation across the United States While recognized as important, this report does not address policies or examples of successful energy efficiency or alternative-fuel vehicle strategies. In addition, we summarize the renewable energy policy strategies undertaken by three areas of the United States: New Jersey, Hawaii, and San Francisco.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fort Mojave Indian Tribe Aha Macav Power Service Renewable Energy Project

Aha Macav Power Service (AMPS), on behalf of the Fort Mojave Indian Tribe received a Department of Energy Solar grant. Partnering with Stockbridge Energy Group and the Department of Energy, AMPS was able to construct, install, test and successfully put into operation a 2.3 MW solar field. As provided in the solar data, this project has helped to offset the cost of open market purchase power needed to meet the needs of the Tribe. The estimated value of the solar energy produced in FY2021 currently is more than $294,000. Eventual expansion of the solar project is projected to create future energy independence for the Fort Mojave Indian Tribe.

14 SOLAR ENERGY↗

Battery and backup generator sizing for a resilient microgrid under stochastic extreme events

Owing to the recent power outages caused by extreme events, installing battery energy storage and backup generators is important to improve resiliency for a grid-tied microgrid. In the design stage, the event occurrence time and duration, which are highly uncertain and cannot be effectively predicted, may affect the needed battery and backup generator capacity but are usually assumed to be pre-determined in utility planning tools. This study investigates the optimal battery and backup generator sizing problem considering the stochastic event occurrence time and duration for the grid-tied microgrid under islanded operation. The reliability requirement is quantified by the mean value of the critical customer interruption time in each stochastic islanding time window (ITW), whose length is the duration and the centre is the occurrence time. The stochastic ITW constraint is then transformed to a probability-weighted expression to derive an equivalent Mixed Integer Linear Programming model. Numerical simulations on a realistic grid-tied PV-based microgrid demonstrate that the total cost is reduced by 11.5% considering the stochastic ITW, compared with the deterministic ITW under the same reliability requirement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent Photovoltaic Performance Data in the USA (Presentation)

This paper presents performance data from nearly 50,000 Photovoltaic systems totaling 1.7 Gigawatts installed capacity in the USA from 2009 to 2012. 90% of the systems performed to within 10% or better of expected performance. Only 2-4% of the data indicate issues significantly affecting the system performance. Special causes of underperformance and their impacts are delineated by reliability category. Delays and interconnections dominate project-related issues particularly in the first year, but total less than 0.5% of all systems. Hardware-related issues are dominated by inverter problems totaling less than 0.4% and underperforming modules to less than 0.1%.

14 SOLAR ENERGY↗

Optimizing Distributed Photovoltaic System Set Points Under Uncertainty

We explore the potential for using dynamic programming (DP) and approximate dynamic programming (ADP) techniques to optimize the set points of distributed photovoltaic (DGPV) inverters under uncertainty about future DGPV deployment. We consider a case where a large (=1MW) system is installed first, and growth in deployment of small rooftop systems is anticipated, but uncertain. We find that for a real feeder (EPRI's J1 feeder), a significant reduction in the number and severity of voltage violations can be expected when DP or ADP is used compared to selecting set points based on the current conditions (the traditional myopic approach). Additionally, we find that using a simple ADP algorithm, sampled backward induction, is more than twice as fast as DP with similar outcomes.

14 SOLAR ENERGY↗

Hybrid Power Plants: Status of Installed and Proposed Projects [Slides]

As battery prices fall and wind and solar generation rises, power plant developers are increasingly combining wind and solar projects with on-site batteries, creating “hybrid” power plants. But hybrid or co-located plants have been part of the U.S. electricity mix for decades, with widely ranging configurations that extend beyond pairing a generator with a battery. This new summary tracks and maps existing hybrid and co-located plants across the United States while also synthesizing data from generation interconnection queues to illustrate developer interest in the next wave of plants. The scope is inclusive of co-located hybrid plants that pair two or more generators and/or that pair generation with storage at a single point of interconnection, and also full hybrids that feature co-location and co-control. The focus is on larger, 1 MW+ systems: smaller (often behind-the-meter) projects are also increasingly common, but are not included in the data synthesis. Based in part on EIA Form 860 data, there were at least 125 co-located hybrid plants (>1 MW) already operating across the United States at the end of 2019, totaling over 14 GW of aggregate capacity. Some of the most common configurations include wind+storage (13 projects, 1,290 MW wind, 184 MW storage), PV+storage (40 projects, 882 MW PV, 169 MW storage), and fossil+storage (10 projects, 2,414 MW fossil, 91 MW storage). Data from interconnection queues demonstrates the considerable commercial interest that exists in hybrid power plants, especially solar co-located with storage. By the end of 2019, there were at least 367 GW of solar plants in the nation’s queues; 102 GW (~28%) of this capacity was proposed as a hybrid, most typically pairing PV with battery storage. For wind, 225 GW of capacity sat in the queues, with 11 GW (~5%) proposed as a hybrid, again most-often pairing wind with storage. The proposed solar+storage plants are located throughout the United States, but with California and the non-ISO West being the most prominent areas of commercial interest. Proposed wind+storage and standalone storage plants also center to a degree on these regions of the country.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Life-cycle costing assessment of back contact doping and encapsulation alternatives for increasing the life expectancy of CdTe PV modules (Final Report)

Contribution of Research to the State-of-Knowledge This research produced comparative sustainability evaluations of back contact doping and encapsulation alternatives considered by First Solar for decreasing degradation and increasing the life of the cadmium telluride (CdTe) photovoltaic (PV) modules. Technical Effectiveness and Economic Feasibility of Methods Investigated A holistic life-cycle-assessment of the alternatives considered for longer module operational lives, showed that they add between 0.2% and 2% to environmental impact indicators at the cradle-to-gate module level, but at the cradle-to-grave system level, alternative materials offer only benefits (i.e., environmental impact indicator decreases) to the public and the environment. Parallel experimental studies at First Solar showed that the use of the considered alternative materials did not impact the effectiveness of the current module recycling separations and material recovery processes. Furthermore, the increment on the module manufacturing cost due to using alternative materials was estimated to be negligible (i.e., >1%) and longer module lives more than compensate cost increases. Specifically, increase of the current warranted module life of 30 years to 50 years, would decrease the levelized cost of electricity (LCOE) from $40/MWh to $24/MWh for utility-scale installations in the US-SW, the economic feasibility of the considered alternatives is assured. Benefit to the Public With decreasing degradation from the current ~0.3%/year of Series 6 modules to less than 0.2%/year, the public will be benefited by longer photovoltaic operational lives, and therefore. In addition, the requirement for end-of-life management is shifted from 30 years to 40 or 50 years, with profound benefits to the public and the environment.

14 SOLAR ENERGY↗

Comprehensive study of performance degradation of field‐mounted photovoltaic modules in India

Abstract The All India Survey of Photovoltaic Module Reliability 2014 is an enhanced version of the survey conducted in the previous year, with detailed characterization of PV modules including current‐voltage, infrared and electroluminescence imaging, visual inspection, insulation resistance test and interconnect breakage test. More than a thousand modules were inspected in the field and the main results of the survey are presented in this paper. The average P max degradation rate for the so‐called ‘good’ modules (Group X) is 1.33%/year which is higher than that commonly projected by manufacturers, and widely employed in financial calculations. Modules falling in the ‘not‐so‐good’ category (Group Y) show even higher degradation rates, and it is at least partly due to higher number of micro‐cracks in the modules, and increased degradation of the packaging materials like encapsulant, backsheet, etc. Modules in ‘Hot’ climates degrade faster than modules in the ‘Non‐Hot’ climates. Degradation in fill factor is the primary cause for performance degradation in the young modules (ages <5 years), whereas short‐circuit current degradation is the main contributor to power degradation in the older modules. Small installations (<100 kW p capacity) show higher degradation than large systems, which may be partly due to lack of proper due diligence by the owner at the time of procurement and installation.

Dubey, Rajiv↗

Low-Cost III-V Photovoltaic Materials by Chloride Vapor Transport Deposition Using Safe Solid Precursors

Si-based photovoltaic devices dominate the market. As photovoltaic (PV) manufacturing costs have plummeted, technologies which increase efficiency have become critical. Si cell efficiencies are nearing theoretical limits and Si-based PV modules are unlikely to reach the 25-30% efficiency range. The use of III-V semiconductors is an obvious technical solution to improve efficiency, especially if they can be integrated directly with existing Si technology as tandems. High coefficients of light absorption along with tunable bandgaps and lattice constants have resulted in record conversion efficiencies for both one-sun and concentrator PV applications. GaAs, for example, has been used to manufacture single-junction photovoltaics with world-record efficiencies of 28.8% at one sun.2 However, costs for III-Vs must be dramatically reduced to produce cost-effective, high-efficiency PV solutions. III-V costs are controlled by two factors: semiconductor growth and the substrate. III-V growth is dominated today by metal-organic vapor phase epitaxy (MOVPE) with a lesser role played by molecular beam epitaxy (MBE). MOVPE costs are high due to the expense and low utilization (~30%) of precursors, modest growth rates (~100 nm min -1 ), equipment complexity, and safety infrastructure needed to handle toxic, pyrophoric gases.3 MBE costs are high due to slow growth rates and limitations of scalability. Details comparing plausible low-cost III-V growth methods are available in a review article published as a result of this project. The primary goal of this project was to demonstrate that close-spaced vapor transport (CSVT) using chloride (from HCl) as a transport agent can be used for the rapid growth of device-ready III-V layers from safe, solid-source precursors. In pursuit of this goal, we designed, built, and installed a new Cl-CSVT reactor based on insights from our previous H 2 O-CSVT growth system and in collaboration with equipment professionals at Malachite Technologies. This system was successfully used to grow epitaxial GaAs with controlled n-type doping, having mobilities similar to MOVPE. Detailed technical information and results can also be found in the primary publication resulting from this project. This work sets the stage for tackling the development of high-performance III-V single junctions and tandem devices directly on Si substrates, which was beyond the capabilities of our H2O-CSVT system. The design of the reactor’s source and substrate transfer system should allow for direct deposition of device structures. The collective innovations of our Cl-CSVT system might ultimately serve as an enabling process for commercialization of the technology through a collaboration with appropriate industrial partners.

14 SOLAR ENERGY↗

Homebuilder's Guide to Going Solar (Brochure)

A Homebuilder's Guide to Going Solar is designed to help you assess the benefits to your business and customers of installing solar equipment or making your houses solar-ready. The information comes from studies of builders who have successfully integrated solar into their operations as well as conversations with builders and solar professionals. These studies and conversations indicate that builders want to know: (1) Do solar economics work in my area? (2) If not, are there other reasons to go solar?; and (3) Is there a local support system of solar professionals I can call on to help me integrate solar seamlessly into my projects? This effort to educate builders about solar is a work in progress.

14 SOLAR ENERGY↗