Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Applicability of moire deflection tomography for diagnosing arc plasmas

The argon arc plasma whose central temperature, 1.90x10{sup 4} K, is used as a practical example for an experiment to research the applicability of moire deflection tomography in arc plasma flow-field diagnosis. The experimental result indicates that moire deflection of the measured argon arc plasma is very small, even smaller than that of a common flame with the maximal temperature of nearly 1.80x10{sup 3} K. The refractive-index gradient in moire deflection tomography mainly contributes to the temperature gradient in essence when the probe wavelength and pressure are certain in plasma diagnosis. The applicable temperature ranges of moire deflection tomography in the argon arc plasma diagnosis are given with the probe wavelength 532 nm at 1 atm in certain measuring error requirements. In a word, the applicable temperature range of moire deflection tomography for arc plasma diagnosis is intimately related to the probe wavelength and the practical measuring requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of energetic electrons on dust charging in hot cathode filament discharge

The effect of energetic electrons on dust charging for different types of dust is studied in hydrogen plasma. The hydrogen plasma is produced by hot cathode filament discharge method in a dusty plasma device. A full line cusped magnetic field cage is used to confine the plasma elements. To study the plasma parameters for various discharge conditions, a cylindrical Langmuir probe having 0.15 mm diameter and 10.0 mm length is used. An electronically controlled dust dropper is used to drop the dust particles into the plasma. For different discharge conditions, the dust current is measured using a Faraday cup connected to an electrometer. The effect of secondary emission as well as discharge voltage on charging of dust grains in hydrogen plasma is studied with different dust.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of atomic radical monitoring probe and its application to spatial distribution measurements of H and O atomic radical densities in radical-based plasma processing

Atomic radicals such as hydrogen (H) and oxygen (O) play important roles in process plasmas. In a previous study, we developed a system for measuring the absolute density of H, O, nitrogen, and carbon atoms in plasmas using vacuum ultraviolet absorption spectroscopy (VUVAS) with a compact light source using an atmospheric pressure microplasma [microdischarge hollow cathode lamp (MHCL)]. In this study, we developed a monitoring probe for atomic radicals employing the VUVAS with the MHCL. The probe size was 2.7 mm in diameter. Using this probe, only a single port needs to be accessed for radical density measurements. We successfully measured the spatial distribution of the absolute densities of H and O atomic radicals in a radical-based plasma processing system by moving the probe along the radial direction of the chamber. This probe allows convenient analysis of atomic radical densities to be carried out for any type of process plasma at any time. We refer to this probe as a ubiquitous monitoring probe for atomic radicals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma properties of RF magnetron sputtering system using Zn target

In the present work, we investigate the fundamental properties of magnetron sputtering plasma using Zn target and its deposited Zn thin film. The magnetron sputtering plasma was produced using radio frequency (RF) power supply and Argon (Ar) as ambient gas. A Langmuir probe was used to collect the current from the plasma and from the current intensity, we calculate the electron density and electron temperature. The properties of Zn sputtering plasma at various discharge conditions were studied. At the RF power ranging from 20 to 100 W and gas pressure 5 mTorr, we found that the electron temperature was almost unchanged between 2-2.5 eV. On the other hand, the electron temperature increased drastically from 6 Multiplication-Sign 10{sup 9} to 1 Multiplication-Sign 10{sup 10}cm{sup -3} when the discharge gas pressure increased from 5 to 10 mTorr. The electron microscope images show that the grain size of Zn thin film increase when the discharge power is increased. This may be due to the enhancement of plasma density and sputtered Zn density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited)

A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation between excitation temperature and electron temperature with two groups of electron energy distributions

The relationship between the electron excitation temperature (T{sub exc}) determined by optical emission spectroscopy and the electron temperature (T{sub e}) using a rf-compensated Langmuir probe was investigated in argon capacitively coupled plasmas. In the experiment performed at the gas pressure range of 30 mTorr to 1 Torr and the rf power range of 5-37 W, the electron energy probability function (EEPF) obtained from the probe current versus voltage characteristic curve showed two energy groups of electrons. The measured EEPF demonstrated that the electron energy distribution changed from Druyvesteyn to single Maxwellian as the discharge current was increased and from bi-Maxwellian to Druyvesteyn as the pressure was increased. As a result, T{sub exc} showed a tendency identical to that of T{sub e} of the high energy part of electrons as pressure and rf power were varied. This suggests that electron temperature can be determined from the measured T{sub exc} through a calibration experiment by which the ratio between electron and excitation temperatures is measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional time resolved measurements of toroidal velocity correlated with density blobs in magnetized plasmas

A new method for toroidal velocity measurements with Mach probes is presented. This technique is based on the conditional sampling technique, the triggering events being density blobs. A reconstruction of the time resolved two-dimensional profile of electron density, electron temperature, plasma potential, and toroidal velocity is possible with a single point measurement on a shot-to-shot basis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Investigation of the Role of Fluid Turbulent Stresses and Edge Plasma Flows for Intrinsic Rotation Generation in DIII-D H-Mode Plasmas

The first measurements of turbulent stresses and flows inside the separatrix of a tokamak H-mode plasma are reported, using a reciprocating multitip Langmuir probe at the DIII-D tokamak. A strong co-current rotation layer at the separatrix is found to precede intrinsic rotation development in the core. The measured fluid turbulent stresses transport toroidal momentum outward against the velocity gradient and thus try to sustain the edge layer. However, large kinetic stresses must exist to explain the net inward momentum transport leading to co-current core plasma rotation. The importance of such kinetic stresses is corroborated by the success of a simple orbit loss model, representing a purely kinetic mechanism, in the prediction of features of the edge corotation layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion source development for a photoneutralization based NBI system for fusion reactors

The next step after ITER is to demonstrate the viability and generation of electricity by a future fusion reactor (DEMO). The specifications required to operate an NBI system on DEMO are very demanding. The system has to provide a very high level of power and energy, ~100MW of D° beam at 1MeV, including high wall-plug efficiency (η > 60%). For this purpose, a new injector concept, called Siphore, is under investigation between CEA and French universities. Siphore is based on the stripping of the accelerated negative ions by photo-detachment provided by several Fabry-Perot cavities (3.5MW of light power per cavity) implemented along the D{sup −} beam. The beamline is designed to be tall and narrow in order that the photon flux overlaps the entire negative ion beam. The paper will describe the present R and D at CEA which addresses the development of an ion source and pre-accelerator prototypes for Siphore, the main goal being to produce an intense negative ion beam sheet. The negative ion source Cybele is based on a magnetized plasma column where hot electrons are emitted from the source center. Parametric studies of the source are performed using Langmuir probes in order to characterize the plasma and to compare with numerical models being developed in French universities.

43 PARTICLE ACCELERATORS↗

Lyman-α radiation of a probing metastable hydrogen beam to measure electric fields in diluted fluids and plasmas

The interaction between a metastable H(2s) atomic hydrogen beam and an external electric field leads to the emission of the Lyman-α line. It originates in the Stark mixing of the near-degenerate 2s{sub 1/2} and 2p{sub 1/2} levels separated by the Lamb shift. The quenched radiation proportional to the square of the electric field amplitude is recovered in vacuum by using such an atomic probe beam. For larger electric field, saturation is observed and related to the beam finite transit time. We also observe the strong enhancement of the signal when the field is oscillating at the Lamb shift frequency. This technique is applied in a plasma, offering an alternative way to measure weak electric fields by direct and non-intrusive means.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of new MAST physics in anticipation of first results from MAST Upgrade

We report that the mega amp spherical tokamak (MAST) was a low aspect ratio device (R/a = 0.85/0.65 ~ 1.3) with similar poloidal cross-section to other medium-size tokamaks. The physics programme concentrates on addressing key physics issues for the operation of ITER, design of DEMO and future spherical tokamaks by utilising high resolution diagnostic measurements closely coupled with theory and modelling to significantly advance our understanding. An empirical scaling of the energy confinement time that favours higher power, lower collisionality devices is consistent with gyrokinetic modelling of electron scale turbulence. Measurements of ion scale turbulence with beam emission spectroscopy and gyrokinetic modelling in up-down symmetric plasmas find that the symmetry of the turbulence is broken by flow shear. Near the non-linear stability threshold, flow shear tilts the density fluctuation correlation function and skews the fluctuation amplitude distribution. Results from fast particle physics studies include the observation that sawteeth are found to redistribute passing and trapped fast particles injected from neutral beam injectors in equal measure, suggesting that resonances between the m = 1 perturbation and the fast ion orbits may be playing a dominant role in the fast ion transport. Measured D–D fusion products from a neutron camera and a charged fusion product detector are 40% lower than predictions from TRANSP/NUBEAM, highlighting possible deficiencies in the guiding centre approximation. Modelling of fast ion losses in the presence of resonant magnetic perturbations (RMPs) can reproduce trends observed in experiments when the plasma response and charge-exchange losses are accounted for. Measurements with a neutral particle analyser during merging-compression start-up indicate the acceleration of ions and electrons. Transport at the plasma edge has been improved through reciprocating probe measurements that have characterised a geodesic acoustic mode at the edge of an ohmic L-mode plasma and particle-in-cell modelling has improved the interpretation of plasma potential estimates from ball-pen probes. The application of RMPs leads to a reduction in particle confinement in L-mode and H-mode and an increase in the core ionization source. The ejection of secondary filaments following type-I ELMs correlates with interactions with surfaces near the X-point. Simulations of the interaction between pairs of filaments in the scrape-off layer suggest this results in modest changes to their velocity, and in most cases can be treated as moving independently. A stochastic model of scrape-off layer profile formation based on the superposition of non-interacting filaments is in good agreement with measured time-average profiles. Transport in the divertor has been improved through fast camera imaging, indicating the presence of a quiescent region devoid of filament near the X-point, extending from the separatrix to $ψ_n$ ~ 1.02. Simulations of turbulent transport in the divertor show that the angle between the divertor leg on the curvature vector strongly influences transport into the private flux region via the interchange mechanism. Coherence imaging measurements show counter-streaming flows of impurities due to gas puffing increasing the pressure on field lines where the gas is ionised. MAST Upgrade is based on the original MAST device, with substantially improved capabilities to operate with a Super-X divertor to test extended divertor leg concepts. SOLPS-ITER modelling predicts the detachment threshold will be reduced by more than a factor of 2, in terms of upstream density, in the Super-X compared with a conventional configuration and that the radiation front movement is passively stabilised before it reaches the X-point. 1D fluid modelling reveals the key role of momentum and power loss mechanisms in governing detachment onset and evolution. Analytic modelling indicates that long legs placed at large major radius, or equivalently low at the target compared with the X-point are more amenable to external control. With MAST Upgrade experiments expected in 2019, a thorough characterisation of the sources of the intrinsic error field has been carried out and a mitigation strategy developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigations of lower hybrid wave-plasma coupling by gas puffing in HT-7

Lower hybrid wave (LHW)-plasma coupling experiments in HT-7 [J. K. Xie and HT-7 Group, Proceedings of the 16th International Conference on Fusion Energy, Montreal, 1996 (IAEA, Trieste, 1997), Vol. 1, p. 685] were carried out by means of puffing gas (CD{sub 4} and D{sub 2}) just around the antenna. Both experiments show that wave-plasma coupling is improved by the gas puffing. The maximum distance between the plasma and the antenna is limited to about 8 cm due to the plasma disruption. The variation in the lined averaged density in the different channels gives a possible evidence of the mechanism of the ionization of neutral gas. The effect of the gas flow rate on the wave-plasma coupling shows that an optimized gas flow rate is necessary for good coupling, being consistent with simulation through Brambilla theory qualitatively. Experiments with puffing D{sub 2} show that the improved coupling results from the global density increase and the local gas puffing. Langmuir probe measurements indicate that the gas puffing effectively increases the density and decreases the temperature in scrape of layer. Studies show that the ionization of the puffed gas is affected by both LHW electric field and plasma temperature. Comparison of D{sub 2} and CD{sub 4} puffing shows that D{sub 2} improves coupling better with less effect on core density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of a permanent-magnet helicon source at 27 and 13 MHz

A small helicon source is used to create dense plasma and inject it into a large chamber. A permanent magnet is used for the dc magnetic field (B-field), making the system very simple and compact. Though theory predicts that better antenna coupling will occur at 27.12 MHz, it was found that 13.56 MHz surprisingly gives even higher density due to practical effects not included in theory. Complete density n and electron temperature T{sub e} profiles are measured at three distances below the source. The plasma inside the source is also measured with a special probe, even under the antenna. The density there is lower than expected because the plasma created is immediately ejected, filling the experimental chamber. The advantage of helicons over inductively coupled plasmas (with no B-field) increases with RF power. At high B-fields, edge ionization by the Trivelpiece-Gould mode can be seen. These results are useful for design of multiple-tube, large-area helicon sources for plasma etching and deposition because problems are encountered which cannot be foreseen by theory alone.

36 MATERIALS SCIENCE↗

Experimental measurements of the plasma sheath around pinhole defects in a simulated high-voltage solar array

An emissive Langmuir probe was used to measure the potentials within the plasma sheath developed around a hole in a simulated solar array at voltages between 50 and 450 V. The hole sizes were larger than actual pinhole defects; the plasma density was in the 10,000 per cu cm range, which is considerably lower than the density of 1,000,000 per cu cm found at low-earth-orbit altitudes. Despite these inadequacies in the simulation, the experiments indicate that this type of probe is a useful diagnostic technique for investigating the plasma sheaths developing around pinhole defects.

Gabriel, S. B.↗

Collaborative Research Activities of the Arase and Van Allen Probes

This paper presents the highlights of joint observations of the inner magnetosphere by the Arase spacecraft, the Van Allen Probes spacecraft, and ground-based experiments integrated into spacecraft programs. The concurrent operation of the two missions in 2017–2019 facilitated the separation of the spatial and temporal structures of dynamic phenomena occurring in the inner magnetosphere. Because the orbital inclination angle of Arase is larger than that of Van Allen Probes, Arase collected observations at higher L-shells up to L ~ 10. After March 2017, similar variations in plasma and waves were detected by Van Allen Probes and Arase. We describe plasma wave observations at longitudinally separated locations in space and geomagnetically-conjugate locations in space and on the ground. The results of instrument intercalibrations between the two missions are also presented. Arase continued its normal operation after the scientific operation of Van Allen Probes completed in October 2019. The combined Van Allen Probes (2012-2019) and Arase (2017-present) observations will cover a full solar cycle. This will be the first comprehensive long-term observation of the inner magnetosphere and radiation belts.

97 MATHEMATICS AND COMPUTING↗

The effect of an isotopic non-equilibrium plasma on electron temperature measurements

Electron temperatures determined by electrostatic probe, diffuse resonance, and radar backscatter techniques in an isotropic two temperature plasma are presented. Plasma models corresponding to the addition of a minor component of energetic electrons, and models corresponding to a process that cools a fraction of the ionospheric electrons are considered. The diffuse resonance temperature is found to lie between the probe and radar backscatter temperatures. The isotropic models corresponding to the addition of energetic electrons cannot support the reported discrepancies between radio wave and probe electron temperature measurements. Temperature differences similar to the observed differences can be produced by models with a fraction of the electrons at a temperature cooler than that of the main component of electrons.

Benson, R. F.↗

Laboratory realization of relativistic pair-plasma beams

Relativistic electron-positron plasmas are ubiquitous in extreme astrophysical environments such as black-hole and neutron-star magnetospheres, where accretion-powered jets and pulsar winds are expected to be enriched with electron-positron pairs. Their role in the dynamics of such environments is in many cases believed to be fundamental, but their behavior differs significantly from typical electron-ion plasmas due to the matter-antimatter symmetry of the charged components. So far, our experimental inability to produce large yields of positrons in quasi-neutral beams has restricted the understanding of electron-positron pair plasmas to simple numerical and analytical studies, which are rather limited. We present the first experimental results confirming the generation of high-density, quasi-neutral, relativistic electron-positron pair beams using the 440 GeV/c beam at CERN’s Super Proton Synchrotron (SPS) accelerator. Monte Carlo simulations agree well with the experimental data and show that the characteristic scales necessary for collective plasma behavior, such as the Debye length and the collisionless skin depth, are exceeded by the measured size of the produced pair beams. Our work opens up the possibility of directly probing the microphysics of pair plasmas beyond quasi-linear evolution into regimes that are challenging to simulate or measure via astronomical observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-photodetachment and Faraday-cup Measurements in the Expansion Region of a Tandem-type Plasma Source

The study combines experiments on probe diagnostics with laser-photodetachment-technique and Faraday-cup measurements directed towards determination of the position of the extraction device and its influence on the discharge structure. The measurements have been carried out in the second chamber of an inductively-driven tandem plasma source performed as small scale arrangements, with a magnetic filter located just after the transition between the two chambers of the source. Results for the axial profiles of the plasma parameters display the correlation of the ratio n lowbar /n{sub e} of the densities of the negative hydrogen ions and of the electrons and of the concentration of the negative ions with the electron density and temperature: The maxima of the (n lowbar /n{sub e})-ratio and of the density of the negative ions obtained are located at the position of maximum of the electron density behind the filter, in the region of the low electron temperature. Results from probe diagnostics and laser photodetachment measurements at a given axial position for different positions of the Faraday cup show the changes in the spatial distribution of the electron density and temperature and the reduction of the (n lowbar /n{sub e})-ratio and of the density of the negative ions caused by the extraction device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗