Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optimal Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Weather responsive smart ventilation system using multiple optimization parameters

A smart ventilation system which uses outdoor temperature and moisture to optimize control of the system. The main principle is to shift ventilation from time periods that have large indoor-outdoor temperature and moisture differences to periods when these differences are smaller, and their energy and comfort impacts are expected to be less. Fan flow rates are reduced when the outside temperature and moisture falls outside of optimum levels, yet overall air exchange is maintained to ensure chronic and acute exposure to pollutants remains relative to best practice. Online weather and smart thermostat data can be used as control inputs, so no specific measurement devices are needed to control ventilation fans.

Parker, Danny↗

Efficient, direct compilation of SU(N) operations into SNAP & Displacement gates

We present a function which connects the parameter of a previously published short sequence of selective number-dependent arbitrary phase (SNAP) and displacement gates acting on a qudit encoded into the Fock states of a superconducting cavity, $V_k(\alpha)=D(\alpha)R_\pi(k)D(-2\alpha)R_\pi(k)D(\alpha)$ to the angle of the Givens rotation $G(\theta)$ on levels $|k\rangle,|k+1\rangle$ that sequence approximates, namely $\alpha=\Phi(\theta) = \frac{\theta}{4\sqrt{k+1}}$. Previous publications left the determination of an appropriate $\alpha$ to numerical optimization at compile time. The map $\Phi$ gives us the ability to compile directly any $d$-dimensional unitary into a sequence of SNAP and displacement gates in $O(d^3)$ complex floating point operations with low constant prefactor, avoiding the need for numerical optimization. Numerical studies demonstrate that the infidelity of the generated gate sequence $V_k$ per Givens rotation $G$ scales as approximately $O(\theta^6)$. We find numerically that the error on compiled circuits can be made arbitrarily small by breaking each rotation into $m$$\theta/m$ rotations, with the full $d\times d$ unitary infidelity scaling as approximately $O(m^{-4})$. This represents a significant reduction in the computational effort to compile qudit unitaries either to SNAP and displacement gates or to generate them via direct low-level pulse optimization via optimal control.

Job, Joshua↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

Biconjugate Impedance Matching Control of the HERO WEC: Preprint

Effective control strategies are essential for maximizing the power output of wave energy converters (WECs). In this study, we explore the methodology of port-based modelling which can be used for bi-conjugate impedance matching, a type of reactive control that involves maximizing power transfer by setting the load (PTO) impedance to be the complex conjugate of the source impedance (WEC). Despite its foundational role in electrical engineering, this method has seen limited application in wave energy and has not yet been demonstrated in wave-powered desalination systems. We represent our complex multidisciplinary system as an equivalent circuit to explore frequency-based relations. The HERO WEC, a small-scale, modular point absorber (PA) designed for reverse osmosis desalination is used as a case study to demonstrate port-based modelling for control applications. Improving the performance of wave-powered water desalination systems could play a critical role in addressing freshwater scarcity for coastal communities, especially those in remote or disaster-prone regions.

16 TIDAL AND WAVE POWER↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

From TPL assessment to design optimization: Wave energy converter control co-design applied to the RM3

The Reference Model (RM) project developed six marine energy converter concepts using a sequential design methodology, which, while widely adopted in the industry, often overlooks interactions between system components, resulting in suboptimal designs. One such example is the Reference Model 3 (RM3), a two-body point absorber wave energy converter (WEC). An assessment using the Technology Performance Level (TPL) revealed that RM3’s low power-to-cost ratio, partly due to expensive steel construction, limits its techno-economic performance. Here, this study aims to redesign RM3 by reducing its scale and employing control co-design to integrate WEC and Power Take-Off (PTO) dynamics, constraints, and cost considerations within an optimization framework. We demonstrate the limitations of RM3’s current PTO design and explore the benefits of scaling down to enhance techno-economic viability by lowering material costs. Using WecOptTool, we conduct a parameter sweep over gear ratios and spring stiffnesses for various Commercial Off-The-Shelf generators in irregular wave conditions. Our findings emphasize the importance of aligning PTO components with WEC dynamics, showing that control co-design and strategic scaling can improve RM3’s power-to-cost ratio. This study presents a transferable example of applied control co-design for other WECs, supporting early-stage developers in their design decisions.

Off the shelf components↗

Advanced Process Control and Dynamic Optimization of Reversible Solid Oxide Cell Systems for Performance and Long-Term Health

This presentation was delivered at the 2024 Hydrogen Annual Merit Review Meeting. It focuses on three aspects of projects focusing on solid oxide cell systems- advanced control including nonlinear model predictive control and traditional control, dynamic optimization with due consideration of chemical degradation over the cell lifetime, dynamic optimization considering physical degradation.

Allan, Douglas↗

Wind Farm Control and Layout Optimization for U.S. Offshore Wind Farms (Final Report - D5)

This report reviews the results and main conclusions of the NOWRDC project "Wind Farm Control and Layout Optimization for U.S. Offshore Wind Farms." A key finding is that wake steering should be considered a valuable tool for increasing the energy production of wind farms, especially in the event the farms are designed to maximize the energy production of a given boundary area.

17 WIND ENERGY↗

Optimal Structures for Voltage Controllers in Inverters: Preprint

Output voltage regulation is a primary performance objective in power electronics systems which are not supported by a stiff voltage source. In this paper, we pose an optimal voltage control problem for ac inverter systems and study the structure of the resulting feedback laws. Here, it is demonstrated that the solution to the optimal voltage regulation control problem exhibits an inner current-controller structure even though there are no explicit objectives on tracking current which are targeted. Furthermore, the outer-loop voltage control and inner-loop current control structure is insensitive to the weighting transfer functions used in the optimal control problem. Although the inner-outer structure has been used in prior works, the optimal nature of such a structure was not known. In deriving the optimal controller, we also present a systematic design framework which is cognizant of the physical properties of inverters. Case studies are used to study the optimal controller and its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines: Preprint

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be timeconsuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the towerbase damage equivalent loading and better tracking of the rated generator speed and power.

closed-loop control↗

Asymmetric dose–volume optimization with smoothness control for rotating-shield brachytherapy

Purpose: It is important to reduce fluence map complexity in rotating-shield brachytherapy (RSBT) inverse planning to improve delivery efficiency while maintaining plan quality. This study proposes an efficient and effective RSBT dose optimization method which enables to produce smooth fluence maps. Methods: Five cervical cancer patients each with a high-risk clinical-target-volume (HR-CTV) larger than 40 cm{sup 3} were considered as the test cases. The RSBT source was a partially shielded electronic brachytherapy source (Xoft Axxent™). The anchor RSBT plans generated by the asymmetric dose–volume optimization with smoothness control (ADOS) method were compared against those produced by the dose–surface optimization (DSO) method and inverse-planning with simulated annealing (IPSA). Either L{sub 1}-norm or L{sub 2}-norm was used to measure the smoothness of a fluence map in the proposed ADOS method as one weighted term of the objective function. Uniform dwell-time scaling was applied to all plans such that HR-CTV D{sub 90} was maximized without violating the D{sub 2cc} tolerances of the rectum, bladder, and sigmoid colon. The quality of the anchor plans was measured with HR-CTV D{sub 90} of the anchor plans. Single-shielded RSBT [(S-RSBT), RSBT with single, fix sized delivery window] and dynamic-sheilded RSBT [(D-RSBT), RSBT with dynamically varying sized delivery window] delivery plans generated based on the anchor plans were also measured, with delivery time constraints of 10, 20, and 30 min/fraction (fx). Results: The average HR-CTV D{sub 90} values of the anchor plans achieved by the ADOS, DSO, and IPSA methods were 111.5, 94.2, and 107.4 Gy, respectively, where the weighting parameter β used in ADOS with L{sub 2}-norm was set to be 100. By using S-RSBT sequencing and 20 min/fx delivery time, the corresponding D{sub 90} values were 88.8, 81.9, and 83.4 Gy; while using D-RSBT sequencing with 20 min/fx delivery time, the corresponding D{sub 90} values were 91.4, 88.3, and 78.9 Gy, respectively. The average optimization times for ADOS, DSO, and IPSA were, respectively, 77, 4, and 1800 s. By using L{sub 1}-norm instead of L{sub 2}-norm in the ADOS method, the optimization time was increased by 20 s, while the D{sub 90} was reduced by 6.8 Gy on average. ADOS-L1 was found to be more sensitive to the weighting parameter than ADOS-L2. If β was increased to 10 000, the D{sub 90} drop with ADOS-L1 was 38 Gy, while the drop with ADOS-L2 is 13 Gy. Conclusions: The ADOS method had a reasonable optimization time cost, while achieving comparable RSBT dose plans as the IPSA method, which is of much higher time complexity. Compared to the DSO and IPSA methods, ADOS is able to generate anchor plans which are more suitable for RSBT delivery while preserving the high quality of the original plans. Compared to ADOS-L1, ADOS-L2 is able to achieve better quality of anchor plans more efficiently.

60 APPLIED LIFE SCIENCES↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be time-consuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the tower-base damage equivalent loading and better tracking of the rated generator speed and power.

axial flow↗

Simultaneous optimal system and controller design for multibody systems with joint friction using direct sensitivities

Abstract Real-world multibody systems are often subject to phenomena like friction, joint clearances, and external events. These phenomena can significantly impact the optimal design of the system and its controller. This work addresses the gradient-based optimization methodology for multibody dynamic systems with joint friction using a direct sensitivity approach. The Brown–McPhee model has been used to characterize the joint friction in the system. This model is suitable for the study due to its accuracy for dynamic simulation and its compatibility with sensitivity analysis. This novel methodology supports codesign of the multibody system and its controller, which is especially relevant for applications like robotics and servo-mechanical systems, where the actuation and design are highly dependent on each other. Numerical results are obtained using a software package written in Julia with state-of-the-art libraries for automatic differentiation and differential equations. Three case studies are provided to demonstrate the attractive properties of simultaneous optimal design and control approach for certain applications.

Verulkar, Adwait↗

Swarm Intelligence Based Optimal Design of Local Volt/Var Control Function for Distributed Energy Resources

The increasing penetration of renewable based distributed energy resources (DERs) in distribution network (DN) leads to larger and more frequent voltage variation in distributions network (DN), thus posing challenges on voltage control. Real-time local voltage control method is a promising solution for the above issue. However, the local voltage control function needs to be customized and optimized according to real distribution system condition. In this paper, a swarm intelligence based Volt/Var control optimal design method (SO-VVC) is proposed to optimize the control function. Compared with existing approaches, the proposed method can not only represent the nonlinear behaviour of power flow but is also computation efficient. The performance of the proposed SO-VVC is demonstrated by case studies on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville↗

Integration of optimal operational dispatch and controller determined dynamics for microgrid survivability

We present that the reliability and resilience of the electrical power grids are essential to industry, economy and society. Microgrids that are able to island from the bulk electrical grid are one technology that may vastly improve electrical power service to customer loads. To achieve these improvements, an islanded microgrid should be able to operate through the loss of one of its generators without shedding electrical load. The loss of one generator will typically result in significant additional loads, including transient overloads, being placed on the remaining generators. There is also the possibility of additional generator tripping during these processes (i.e. cascading failures), which would likely result in the collapse of the microgrid. The novelty of our work consists in incorporating dynamic models of generator controllers into a microgrid optimal dispatch formulation with the ultimate goal to avoid operational failures and ensure the “survivability” of all-inverter microgrids to generator loss and transient overloads. The integration of generator and controller dynamics into the optimal dispatch formulation significantly increases the computational complexity. As we develop algorithms to restore speed of the optimization, our method can be readily implemented into a new operational strategy capable of an unprecedented level of reliability against generator contingencies. In addition, we quantitatively illustrate the effect of the survivability constraints on the microgrid operating costs and how the related trade-off between capital and operating costs should be taken into account at the design stage. Finally, the methods developed here also apply to the dispatch of off-grid microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Planning Framework for Mesolevel Optimization of Urban Runoff Control Schemes

A planning framework is developed to optimize runoff control schemes at scales relevant for regional planning at an early stage. The framework employs less sophisticated modeling approaches to allow a practical application in developing regions with limited data sources and computing capability. The methodology contains three interrelated modules: (1)the geographic information system (GIS)-based hydrological module, which aims at assessing local hydrological constraints and potential for runoff control according to regional land-use descriptions; (2)the grading module, which is built upon the method of fuzzy comprehensive evaluation. It is used to establish a priority ranking system to assist the allocation of runoff control targets at the subdivision level; and (3)the genetic algorithm-based optimization module, which is included to derive Pareto-based optimal solutions for mesolevel allocation with multiple competing objectives. The optimization approach describes the trade-off between different allocation plans and simultaneously ensures that all allocation schemes satisfy the minimum requirement on runoff control. Our results highlight the importance of considering the mesolevel allocation strategy in addition to measures at macrolevels and microlevels in urban runoff management. (C) 2016 American Society of Civil Engineers.

Zhou, Qianqian↗

Measure Guideline: Condensing Boilers—Control Strategies for Optimizing Performance and Comfort in Residential Applications

The combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater has become a common option for high-efficiency residential space heating in cold climates. While there are many condensing boilers available on the market with rated efficiencies in the low to mid 90% efficient range, it is imperative to understand that if the control systems are not properly configured, these heaters will perform no better than their non-condensing counterparts. Based on previous research efforts, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency (Arena 2010). It was found that there is a significant lack of information for contractors on how to configure the control systems to optimize overall efficiency. For example, there is little advice on selecting the best settings for the boiler reset curve or how to measure and set flow rates in the system to ensure that the return temperatures are low enough to promote condensing. It has also been observed that recovery from setback can be extremely slow and, at times, not achieved. Recovery can be affected by the outdoor reset control, the differential setting on the boiler and over-sizing of the boiler itself. This guide is intended for designers and installers of hydronic heating systems interested in maximizing the overall system efficiency of condensing boilers when coupled with baseboard convectors. It is applicable to new and retrofit applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗