Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Origin and dynamics of emission line clouds in cooling flow environments

The author suggests that since clouds are born co-moving in a turbulent intra-cluster medium (ICM), the allowed parameter space can now be opened up to a more acceptable range. Large-scale motions can be driven in the central parts of cooling flows by a number of mechanisms including the motion of the central and other galaxies, and the dissipation of advected, focussed rotational and magnetic energy. In addition to the velocity width paradox, two other paradoxes (Heckman et al. 1989) can be solved if the ICM is turbulent. Firstly, the heating source for the emission line regions has always been puzzling - line luminosities are extremely high for a given (optical or radio) galaxy luminosity compared to those in non-cooling flow galaxies, therefore a mechanism peculiar to cooling flows must be at work. However most, if not all, previously suggested heating mechanisms either fail to provide enough ionization or give the wrong line ratios, or both. The kinetic energy in the turbulence provides a natural energy source if it can be efficiently converted to cloud heat. Researchers suggest that this can be done via magneto-hydrodynamic waves through plasma slip. Secondly, while the x ray observations indicate extended mass deposition, the optical line emission is more centrally concentrated. Since many of the turbulence-inducing mechanisms are strongest in the central regions of the ICM, so is the method of heating. In other words material is dropping out everywhere but only being lit up in the center.

Loewenstein, Michael↗

Portable dual field gradient force multichannel flow cytometer device with a dual wavelength low noise detection scheme

Systems and methods for combining dielectrophoresis, magnetic forces, and hydrodynamic forces to manipulate particles in channels formed on top of an electrode substrate are discussed. A magnet placed in contact under the electrode substrate while particles are flowing within the channel above the electrode substrate allows these three forces to be balanced when the system is in operation. An optical detection scheme using near-confocal microscopy for simultaneously detecting two wavelengths of light emitted from the flowing particles is also discussed.

47 OTHER INSTRUMENTATION↗

Temporal laser pulse manipulation using multiple optical ring-cavities

An optical pulse stretcher and a mathematical algorithm for the detailed calculation of its design and performance is disclosed. The optical pulse stretcher has a plurality of optical cavities, having multiple optical reflectors such that an optical path length in each of the optical cavities is different. The optical pulse stretcher also has a plurality of beam splitters, each of which intercepts a portion of an input optical beam and diverts the portion into one of the plurality of optical cavities. The input optical beam is stretched and a power of an output beam is reduced after passing through the optical pulse stretcher and the placement of the plurality of optical cavities and beam splitters is optimized through a model that takes into account optical beam divergence and alignment in the pluralities of the optical cavities. The optical pulse stretcher system can also function as a high-repetition-rate (MHz) laser pulse generator, making it suitable for use as a stroboscopic light source for high speed ballistic projectile imaging studies, or it can be used for high speed flow diagnostics using a laser light sheet with digital particle imaging velocimetry. The optical pulse stretcher system can also be implemented using fiber optic components to realize a rugged and compact optical system that is alignment free and easy to use.

Nguyen, Quang-Viet↗

Improvement in Rayleigh Scattering Measurement Accuracy

Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous velocity, density, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of an acousto-optic frequency shifting device to improve measurement accuracy in Rayleigh scattering experiments at the NASA Glenn Research Center. The frequency shifting device is used as a means of shifting the incident or reference laser frequency by 1100 MHz to avoid overlap of the Rayleigh and reference signal peaks in the interference pattern used to obtain the velocity, density, and temperature measurements, and also to calibrate the free spectral range of the Fabry-Perot etalon. The measurement accuracy improvement is evaluated by comparison of Rayleigh scattering measurements acquired with and without shifting of the reference signal frequency in a 10 mm diameter subsonic nozzle flow.

Fagan, Amy F.↗

Uniform Whole Wafer Anisotropic Etching of Structural Ta Thin Films

Tantalum (Ta) has promise as a structural material for micromechanical sensors and actuators. Anisotropic etching of alpha (α) phase Ta is required for micromachining applications. Uniform thickness and etch across a full wafer are desirable features. An experimental investigation is conducted to study plasma etching rate and anisotropy in etching α -Ta in relation to pressure and gas flow ratio. A comparatively low toxicity gas, carbon tetrafluoride (CF4), and argon (Ar) are used. Spectrometry by optical emission spectrometry (OES) and residual gas analysis (RGA) are employed to characterize the plasma to gain insight into the etch mechanisms. At low flow, the etch rate is slow due to an inadequate supply of the etching gas, CF4. The etch rate is also slowed at high flow due to a reduced CF4 residence time. Flow and pressure conditions to achieve a good etch rate and vertical sidewalls are identified and explained by means of a full factorial experiment coupled with emission spectra. Finally, with these conditions, uniform etching of 2.5 μm thick α-Ta across a 4-inch wafer is demonstrated.

36 MATERIALS SCIENCE↗

Production of monodisperse cerium oxide microspheres with diameters near 100 µm by internal-gelation sol–gel methods

Cerium dioxide microspheres with uniform diameters between 65 – 211 µm were fabricated using internal gelation sol-gel methods. Although uniform microspheres are produced for nuclear fuel applications with diameters above 300 µm, sol-gel microspheres with diameters of 50 - 200 µm have historically been made by emulsion techniques and had poor size uniformity [1, 2]. An internal gelation, sol-gel apparatus was designed and constructed to accommodate the production of small, uniform microspheres whereby cerium-containing solutions were dispersed into flowing silicone oil and heated in a gelation column to initiate solidification [3, 4]. Problems with premature feed gelation and microsphere coalescence were overcome by equipment modifications unique among known internal gelation setups. Microspheres were fabricated and sized in batches as a function of dispersing needle diameter and silicone oil flow rate in the two-fluid nozzle in order to determine the range of sizes possible and corresponding degree of monodispersity. Initial experiments with poor size uniformity were linked to microsphere coalescence in the gelation column prior to solidification as well as excessive flow rates for the cerium feed solution. Average diameter standard deviations as low as 2.23% were observed after optimization of flow rates and minimization of coalescence reactions.

cerium oxide↗

On-demand in situ generation of oxygen in a nanofluidic embedded planar microband electrochemical reactor

In situ generation of reagents and their subsequent use downstream presents new opportunities to amplify the utility of nanofluidic devices by exploiting the confined geometry to address mass transport limitations on reaction kinetics and efficiency. Oxygen, an inherently valuable reactant, can be produced from electrolysis of water, a process that can be conveniently integrated within a nanofluidic system. Here, we construct and characterize a nanofluidic device consisting of a planar microband electrode embedded within a nanochannel for in situ electrochemical generation and optical monitoring of O 2 . Fluorescein, a dye with a pH-sensitive emission intensity, was used to monitor the spatiotemporal characteristics of the oxidation of H 2 O, using the co-produced H + . Application of anodic potentials at the nanochannel-embedded electrode results in a decrease in fluorescence intensity, which reflects the decreasing solution pH. A combination of fluorescence intensity and chronoamperometric response was used to quantitatively determine proton generation, and the H + /O 2 stoichiometry was then used to determine the concentration of the O 2 in the channel. Comparison of the experimental results to finite element simulations validates the use of fluorescein emission intensity to spectroscopically determine the local oxygen concentration in the nanochannel. By varying the applied potential, spatially averaged O 2 concentrations ranging from 0.13 to 0.41 mM were generated. In conclusion, the results demonstrate a convenient route to in situ modulation of the dissolved O 2 level in a nanofluidic device and the use of an optical probe to monitor its spatial and temporal distribution under flow conditions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of 316 stainless steel powder processing conditions on microstructure

One parameter that has both economic and performance effects in the manufacturing of steel parts is the powder feedstock used. 316 L steel powder can be produced through water atomization or gas atomization, where both the powder size and the atomization process determine the cost of powder feedstock. Gas atomized powder is spherical and has a lower oxygen content than water atomized powder, making it the preferred choice for performance, but comes at a higher financial cost. Here, in this study, various 316 L powder batches are characterized to understand physical properties and microstructural variations. Density and flowability were determined using gas pycnometry and Hall flow tests. Powder morphology and porosity were qualitatively analyzed via optical microscopy and scanning electron microscopy, Finally, transmission electron microscopy was used to determine changes in phases present. Spherical gas atomized powder of 30–100 μm contained Mn$-$Si rich oxides both on the surface and within the matrix. Meanwhile, irregular water atomized powder 30 μm in diameter contained silicon oxides without manganese. All powder particles contained a nickel rich cellular structure which was shown to support the formation of additional phases. While literature has observed general microstructural features across 316 L powder particles, transmission electron microscopy (TEM) in this study has identified variations in precipitation and cell structures. Information regarding morphology, flowability, density, and phase distributions can be applied to understand variations in part consolidation, which will in turn show which powder aspects are significant for production.

Chemical segregation↗

High-density carbon ablator ignition path with low-density gas-filled rugby hohlraum

A recent low gas-fill density (0.6 mg/cc 4 He) cylindrical hohlraum experiment on the National Ignition Facility has shown high laser-coupling efficiency (>96%), reduced phenomenological laser drive corrections, and improved high-density carbon capsule implosion symmetry [Jones et al., Bull. Am. Phys. Soc. 59(15), 66 (2014)]. In this Letter, an ignition design using a large rugby-shaped hohlraum [Amendt et al., Phys. Plasmas 21, 112703 (2014)] for high energetics efficiency and symmetry control with the same low gas-fill density (0.6 mg/cc 4 He) is developed as a potentially robust platform for demonstrating thermonuclear burn. The companion high-density carbon capsule for this hohlraum design is driven by an adiabat-shaped [Betti et al., Phys. Plasmas 9, 2277 (2002)] 4-shock drive profile for robust high gain (>10) 1-D ignition performance and large margin to 2-D perturbation growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Replenishing liquid sheet targets to enable high-intensity high-repetition-rate laser–plasma interactions for ion-beam technology

We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm 2 , and in-vacuum dimensions of 6 × 1.5 mm 2 . The platform was evaluated for stability under hundreds of 4.3 J laser shots at 0.5 Hz and 6 × 10 20 W/cm 2 peak intensity, delivered in burst mode, totaling 2.9 kJ on the target. The key metrics of the platform, including sheet characteristics, nozzle aperture morphology, and proton spectra, showed no measurable degradation in the performance of the liquid sheet platform following this experiment. Beyond its application to ion beam technology, we outline a pathway to further develop the capabilities of the platform into a high-repetition-rate plasma mirror.

depth profiling techniques↗

Filament extension atomizers: A study of integration potential into spray dryers for high-viscosity and non-Newtonian fluids

Filament extension atomizers (FEAs) are an emerging class of spray nozzles designed to atomize high-viscosity and non-Newtonian fluids that are challenging for conventional pressure or two-fluid nozzles. In this study, we investigate the influence of roller geometry, surface velocity, roller material, and fluid rheology on the atomization performance of FEA systems using concentrated whey protein suspensions (50–70 wt. %). Extensional and shear rheology experiments, along with high-speed imaging and particle image velocimetry, reveal that filament breakup dynamics are governed by competition between inertial, capillary, and viscoelastic stresses. High roller rotational velocity leads to narrower spray cones, contradicting rheology experiments and suggests a significant inertial contribution to filament breakup. Smaller rollers operating at the same rotational velocity led to broader spray cones consistent with expectations. An FEA nozzle was integrated into a conventional dryer producing particles in the 100 μm range. Results suggest that FEA technology enables atomization of highly viscous fluids at industrially relevant spray cone angles similar to those generated by pressure nozzles, offering a pathway to improve energy efficiency in spray drying by enabling higher solids loading feedstocks. Furthermore, these insights provide critical guidance for optimizing FEA nozzle designs and process parameters across a range of applications.

Energy efficiency↗

The frequency of extreme X-ray variability for radio-quiet quasars

ABSTRACT We analyse 1598 serendipitous Chandra X-ray observations of 462 radio-quiet quasars to constrain the frequency of extreme amplitude X-ray variability that is intrinsic to the quasar corona and innermost accretion flow. The quasars in this investigation are all spectroscopically confirmed, optically bright (mi ≤ 20.2), and contain no identifiable broad absorption lines in their optical/ultraviolet spectra. This sample includes quasars spanning z ≈ 0.1–4 and probes X-ray variability on time-scales of up to ≈12 rest-frame years. Variability amplitudes are computed between every epoch of observation for each quasar and are analysed as a function of time-scale and luminosity. The tail-heavy distributions of variability amplitudes at all time-scales indicate that extreme X-ray variations are driven by an additional physical mechanism and not just typical random fluctuations of the coronal emission. Similarly, extreme X-ray variations of low-luminosity quasars seem to be driven by an additional physical mechanism, whereas high-luminosity quasars seem more consistent with random fluctuations. The amplitude at which an X-ray variability event can be considered extreme is quantified for different time-scales and luminosities. Extreme X-ray variations occur more frequently at long time-scales (Δt ≳ 300 d) than at shorter time-scales and in low-luminosity quasars compared to high-luminosity quasars over a similar time-scale. A binomial analysis indicates that extreme intrinsic X-ray variations are rare, with a maximum occurrence rate of $\lt 2.4{{\ \rm per\ cent}}$ of observations. Finally, we present X-ray variability and basic optical emission-line properties of three archival quasars that have been newly discovered to exhibit extreme X-ray variability.

Timlin, III, John D.↗

Rectified Rotational Dynamics of Mobile Inclusions in Two-Dimensional Active Nematics

We investigate the dynamics of mobile inclusions embedded in 2D active nematics. The interplay between the inclusion shape, boundary-induced nematic order, and autonomous flows powers the inclusion motion. Disks and achiral gears exhibit unbiased rotational motion, but with distinct dynamics. In comparison, chiral gear-shaped inclusions exhibit long-term rectified rotation, which is correlated with dynamics and polarization of nearby +1/2 topological defects. Furthermore, the chirality of defect polarities and the active nematic texture around the inclusion correlate with the inclusion’s instantaneous rotation rate. Inclusions provide a promising tool for probing the rheological properties of active nematics and extracting ordered motion from their inherently chaotic motion.

36 MATERIALS SCIENCE↗

Fuel Stratification Influence on NO x Emission in a Premixed Axial Reacting Jet-in-Crossflow at High Pressure

Three reacting jet-in-crossflow (JiC) methane/air flames were numerically investigated in a lean axially staged combustor at a pressure of five atmospheres. A detailed chemistry Star-CCM+ computational fluid dynamics (CFD) model was used with 53 species considered and the result of turbulence-governed finite-rate modeling was validated with in-house experimental data. An optically accessible test section features three side windows, allowing local flow and flame analysis with particle image velocimetry (PIV) and CH* chemiluminescence as well as pressure, temperature, and species exit measurements. The research objective was to predict and verify NO x formation of the premixed 12.7 mm axial jet. Three headend temperature levels were investigated along with three premixed jets at lean (φ Jet = 0.75), near-stoichiometric (φ Jet = 1.07), and rich (φ Jet = 1.78) axial fuel line equivalence ratio. Based on the matching exit emission concentration, global emission benefits were investigated by adjustment of the fuel stratification. The perfectly premixed methane/air flames of this study were shown to ignite at the lee-side of the jet. For the elevated headend temperature level T = 1800 K, the flame extended beyond the windward jet trajectory and caused high axial NO production. For industry application, a firing temperature of 1920 K was achieved with a NO x optimized fuel split of 25%, combining a lean headend (φ Headend = 0.61) with a rich (φ Jet = 1.78) jet equivalence ratio. As a result, this operating point allowed minimization of the combustor residence time at temperatures above 1700 K as well as combustion in a compact flame at the jet lee-side along the counter rotating vortex pair.

03 NATURAL GAS↗

A two color, dual beam backscattering laser Doppler velocimeter

A laser Doppler velocimeter has been developed which uses two of the colors emitted from an argon ion laser for the simultaneous measurement of orthogonal velocities. Designed for use in a 2.13 m by 3.05 m wind tunnel, it is capable of traversing its focal volume across spatially unstable flows at scan speeds of up to 1.15 m/sec. Its optical layout and principles of operation are discussed and the data from a typical traversal of a trailing wing tip vortex are presented.

Grant, G. R.↗

Laser Doppler velocimeter measurements in a turbine stator cascade facility

A laser Doppler velocimeter (LDV) developed for mapping the flow velocity downstream from a 32-inch diameter annular cascade of turbine stator vanes in described. The LDV measurements were taken in a plane located approximately 0.5 inch downstream of the trailing edges of the vanes. Two components of the mean velocity (axial and circumferential) were measured. The flow velocities were in the high subsonic range. The LDV optics are of the dual scatter type with off-axis collection of the scattered light. The electronics system is based on the measurement of the time interval corresponding to eight periods of the Doppler signal and has a range of 10 to 80 MHz. The LDV measurements are compared with previous measurements made with a pressure probe.

Seasholtz, R. G.↗

Two-color dual-beam backscatter laser Doppler velocimeter

A laser Doppler velocimeter has been developed that uses two of the colors emitted from an argon-ion laser for the simultaneous measurement of orthogonal velocities. Designed for use in a 2.13- by 3.05-m wind tunnel, it is capable of traversing its focal volume across spatially unstable flows at scan speeds of up to 1.5 m/sec. Its optical layout and principles of operation are discussed, and the data from a typical traversal of a trailing wing-tip vortex are presented.

Grant, G. R.↗

Laser Doppler velocimeter measurements in a turbine stator cascade facility

A laser Doppler velocimeter (LDV) developed for mapping the flow velocity downstream from a 32-inch diameter annular cascade of turbine stator vanes is described. The LDV measurements were taken in a plane located approximately 0.5 inch downstream of the trailing edges of the vanes. Two components of the mean velocity (axial and circumferential) were measured. The flow velocities were in the high subsonic range. The LDV optics are of the dual scatter type with off-axis collection of the scattered light. The electronics system is based on the measurement of the time interval corresponding to eight periods of the Doppler signal and has a range of 10 to 80 MHz. The LDV measurements are compared with previous measurements made with a pressure probe.

Seasholtz, R. G.↗