Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Optical Logarithmic Transformation of Speckle Images with Bacteriorhodopsin Films

The application of logarithmic transformations to speckle images is sometimes desirable in converting the speckle noise distribution into an additive, constant-variance noise distribution. The optical transmission properties of some bacteriorhodopsin films are well suited to implement such a transformation optically in a parallel fashion. I present experimental results of the optical conversion of a speckle image into a transformed image with signal-independent noise statistics, using the real-time photochromic properties of bacteriorhodopsin. The original and transformed noise statistics are confirmed by histogram analysis.

Downie, John D.↗

The Solar-B Mission

The Solar-B mission is a joint enterprise between Japan, the United States of America and the United Kingdom. The collaboration is led by ISAS, the Japanese Institute for Space and Astronautical Science (ISAS), NASA and PPARC (Particle Physics and Astrophysics Research Council) play supporting roles in the development of the scientific objectives and provision of the scientific instruments. The mission's primary objective is to conduct a systems study of the solar atmosphere through the acquisition of coordinated measurements of the photosphere, the transition region/low corona and the upper corona using three instruments: an optical telescope, an extreme ultraviolet imaging spectrometer and a soft x-ray telescope. Drs. Saku Tsuneta (NAOJ) and Alan Title (LMSAL) lead the optical imaging team. The optical telescope is a 50-cm aperture, diffraction limited, Gregorian. The focal plane package will record high resolution images, Dopplergrams, and vector magnetic fields on spatial scales dominated by elemental photospheric flux tubes, and over a field of view large enough to contain small active regions. Drs. Tetsuya Watanabe, Len Culhane (MSSL) and George Doschek (NRL) led the EUV imaging and spectroscopy team. The EUV telescope has a 15-cm primary mirror feeding a toroidal grating. The optics have multiplayer coatings which select two wavebands between 180-204 A and 250-290 A. Drs. Kiyoto Shibasaki (NAOJ) and Leon Golub (SAO) lead the X-ray imaging team. The x-ray telescope will provide full disk, soft x-ray images with twice the spatial resolution of the Yohkoh SXT and enhanced sensitivity to longer (>40 A) wavelengths. The launch of Solar-B, into a sun-synchronous orbit, is scheduled for August 2004. Solar-B is the second mission in the Sun-Earth Connection, Solar-Terrestrial Probe Program which is managed by the Goddard Space Flight Center. The Science Directorate of the Marshall Space Flight Center manages the Solar-B Project for the ST Probe Project Office. This paper discusses the objectives, specifications, and design of the scientific instruments as presented at the Preliminary Design Review held at MSFC in May 2000.

Davis, John M.↗

Atomic resolution coherent x-ray imaging with physics-based phase retrieval

Coherent x-ray imaging and scattering from accelerator based sources such as synchrotrons continue to impact biology, medicine, technology, and materials science. Many synchrotrons around the world are currently undergoing major upgrades to increase their available coherent x-ray flux by approximately two orders of magnitude. The improvement of synchrotrons may enable imaging of materials in operando at the atomic scale which may revolutionize battery and catalysis technologies. Current algorithms used for phase retrieval in coherent x-ray imaging are based on the projection onto sets method. These traditional iterative phase retrieval methods will become more computationally expensive as they push towards atomic resolution and may struggle to converge. Additionally, these methods do not incorporate physical information that may additionally constrain the solution. In this work, we present an algorithm which incorporates molecular dynamics into Bragg coherent diffraction imaging (BCDI). This algorithm, which we call PRAMMol (Phase Retrieval with Atomic Modeling and Molecular Dynamics) combines statistical techniques with molecular dynamics to solve the phase retrieval problem. We present several examples where our algorithm is applied to simulated coherent diffraction from 3D crystals and show convergence to the correct solution at the atomic scale.

47 OTHER INSTRUMENTATION↗

An optical systems analysis approach to image resampling

All types of image registration require some type of resampling, either during the registration or as a final step in the registration process. Thus the image(s) must be regridded into a spatially uniform, or angularly uniform, coordinate system with some pre-defined resolution. Frequently the ending resolution is not the resolution at which the data was observed with. The registration algorithm designer and end product user are presented with a multitude of possible resampling methods each of which modify the spatial frequency content of the data in some way. The purpose of this paper is threefold: (1) to show how an imaging system modifies the scene from an end to end optical systems analysis approach, (2) to develop a generalized resampling model, and (3) empirically apply the model to simulated radiometric scene data and tabulate the results. A Hanning windowed sinc interpolator method will be developed based upon the optical characterization of the system. It will be discussed in terms of the effects and limitations of sampling, aliasing, spectral leakage, and computational complexity. Simulated radiometric scene data will be used to demonstrate each of the algorithms. A high resolution scene will be "grown" using a fractal growth algorithm based on mid-point recursion techniques. The result scene data will be convolved with a point spread function representing the optical response. The resultant scene will be convolved with the detection systems response and subsampled to the desired resolution. The resultant data product will be subsequently resampled to the correct grid using the Hanning windowed sinc interpolator and the results and errors tabulated and discussed.

Lyon, Richard G.↗

First Searches for Optical Counterparts to Gravitational-Wave Candidate Events

During the Laser Interferometer Gravitational-wave Observatory and Virgo joint science runs in 2009-2010, gravitational wave (GW) data from three interferometer detectors were analyzed within minutes to select GW candidate events and infer their apparent sky positions. Target coordinates were transmitted to several telescopes for follow-up observations aimed at the detection of an associated optical transient. Images were obtained for eight such GW candidates. We present the methods used to analyze the image data as well as the transient search results. No optical transient was identified with a convincing association with any of these candidates, and none of the GW triggers showed strong evidence for being astrophysical in nature. We compare the sensitivities of these observations to several model light curves from possible sources of interest, and discuss prospects for future joint GW-optical observations of this type.

gravitational waves↗

Mobile Bay turbidity plume study

Laboratory and field transmissometer studies on the effect of suspended particulate material upon the appearance of water are reported. Quantitative correlations were developed between remotely sensed image density, optical sea truth data, and actual sediment load. Evaluation of satellite image sea truth data for an offshore plume projects contours of transmissivity for two different tidal phases. Data clearly demonstrate the speed of change and movement of the optical plume for water patterns associated with the mouth of Mobile bay in which relatively clear Gulf of Mexico water enters the bay on the eastern side. Data show that wind stress in excess of 15 knots has a marked impact in producing suspended sediment loads.

Crozier, G. F.↗

The Fizeau Interferometer Testbed (FIT) for Stellar Imager

Goddard Space Flight Center is pursuing the development of space-based, long-baseline (less than 0.5km) UV-optical Fizeau imaging interferometers to enable the next major stride toward very high angular resolution astronomical observations. This effort includes the development and operation of the Fizeau Interferometer Testbed (FIT), in collaboration with the Naval Research Lab/NPOI, Univ. of MD, and Sigma Space Corporation. The FIT will be used to explore the principles of and requirements for the Stellar Imager (SI) mission concept (http://hires.gsfc.nasa.gov/-si) and other such Fizeau Interferometers/Sparse Aperture Telescope missions. The primary FIT goal is to demonstrate closed-loop control of a many-element (7 - 30) system which keeps the optical beams in phase and thus enables high quality imaging. The FIT will also be used to assess various wavefront reconstruction and sensing and image reconstruction algorithms for utility and accuracy by application to real data generated by the Testbed. In this paper, we describe the design and goals of the system, provide a status report on its construction, and note our future plans. The FIT development is supported by NASA-ROSS/SARA grants to GSFC, UMD, and NRL and by internal GSFC R&D funds.

Carpenter, Kenneth G.↗

Multispectral Imager With Improved Filter Wheel and Optics

Figure 1 schematically depicts an improved multispectral imaging system of the type that utilizes a filter wheel that contains multiple discrete narrow-band-pass filters and that is rotated at a constant high speed to acquire images in rapid succession in the corresponding spectral bands. The improvement, relative to prior systems of this type, consists of the measures taken to prevent the exposure of a focal-plane array (FPA) of photodetectors to light in more than one spectral band at any given time and to prevent exposure of the array to any light during readout. In prior systems, these measures have included, variously the use of mechanical shutters or the incorporation of wide opaque sectors (equivalent to mechanical shutters) into filter wheels. These measures introduce substantial dead times into each operating cycle intervals during which image information cannot be collected and thus incoming light is wasted. In contrast, the present improved design does not involve shutters or wide opaque sectors, and it reduces dead times substantially. The improved multispectral imaging system is preceded by an afocal telescope and includes a filter wheel positioned so that its rotation brings each filter, in its turn, into the exit pupil of the telescope. The filter wheel contains an even number of narrow-band-pass filters separated by narrow, spoke-like opaque sectors. The geometric width of each filter exceeds the cross-sectional width of the light beam coming out of the telescope. The light transmitted by the sequence of narrow-band filters is incident on a dichroic beam splitter that reflects in a broad shorter-wavelength spectral band that contains half of the narrow bands and transmits in a broad longer-wavelength spectral band that contains the other half of the narrow spectral bands. The filters are arranged on the wheel so that if the pass band of a given filter is in the reflection band of the dichroic beam splitter, then the pass band of the adjacent filter is in the longer-wavelength transmission band of the dichroic beam splitter (see Figure 2). Each of the two optical paths downstream of the dichroic beam splitter contains an additional broad-band-pass filter: The filter in the path of the light transmitted by the dichroic beam splitter transmits and attenuates in the same bands that are transmitted and reflected, respectively, by the beam splitter; the filter in the path of the light reflected by the dichroic beam splitter transmits and attenuates in the same bands that are reflected and transmitted, respectively, by the dichroic beam splitter. In each of these paths, the filtered light is focused onto an FPA. As the filter wheel rotates at a constant angular speed, its shaft angle is monitored, and the shaft-angle signal is used to synchronize the exposure times of the two FPAs. When a single narrowband-pass filter on the wheel occupies the entire cross section of the beam of light coming out of the telescope, the spectrum of light that reaches the dichroic beam splitter lies entirely within the pass band of that filter. Therefore, the beam in its entirety is either transmitted by the dichroic beam splitter and imaged on the longer-wavelength FPA or reflected by the beam splitter and imaged onto the shorter-wavelength FPA.

Bremer, James C.↗

Advanced Optical Techniques for Sensing and Imaging in Harsh Environments

Advances in aircraft propulsion technologies require new techniques for performance evaluation of aircraft components and subsystems as well as reliable in-flight control and health management. Those components and subsystems operate in harsh environments and for a proper operation these environments should be constantly monitored to obtain the designed performance of the engine. Optical techniques due to their immunity to electromagnetic radiation, chemical stability, and other unique features pose to meet the ever increasing requirements of the industry.The presentation will address applications of advanced optical techniques for both for sensing and imaging. In the process we will address fiber optics Bragg temperature sensors that were developed at NASA Glenn Research Center and tested at NASA Armstrong Flight Research Center as well as other advanced techniques for sensing and imaging in harsh environments. The presentation will also include discussion on various applications of presented techniques and proposed directions for future development.

Imaging↗

Interferometric and optical tests of water window imaging x ray microscopes

Interferometric tests of Schwarzchild X-ray Microscope are performed to evaluate the optical properties and alignment of the components. Photographic measurements of the spatial resolution, focal properties, and vignetting characteristics of the prototype Water Window Imaging X-ray Microscope are made and analyzed.

Johnson, R. Barry↗

Detailed diffraction imaging of x-ray optics crystals with synchrotron radiation

Rocking curve topography at the Advanced Photon Source’s beamline 1-BM measures the x-ray reflection from large (many cm 2 ) flat crystals on a sub-mm scale with microradian angular resolution. The $(01\bar{1}1)$ reflection at 8 keV is uniform across the crystal and close to theory for three thick quartz wafers well-polished with increasingly finer grit. However, the reflection is non-uniform for some ~ 0.1mmthin, bendable crystals that are made flat by optical contact with a flat substrate. Here, these thin crystals are bent to serve in certain x-ray diagnostics of plasmas, and similar non-uniformities could then occur in bent crystals as well. The same detail in x-ray reflection in bent crystals is unachievable with the existing topography setup: one way to get the desired resolution is with a standard microfocusing approach.

47 OTHER INSTRUMENTATION↗

Quantum Super-resolution Bioimaging using Massively Entangled Multimode Squeezed Light

This report presents a new method for realizing a super-resolution quantum imaging using massively entangled multimode squeezed light (MEMSL). Each branch of the entangled multimode light interacts with the sample and bears the spatially varying optical phase delay. When imaging optics with finite pupil sizes are used, information is lost. Thanks to the analyticity in the Fourier plane, a noiseless measurement would recover the lost information and accomplish super resolution imaging beating the Rayleigh diffraction limit. I proved rigorously in a fully quantum formalism and presented that (1) such information recovery is possible and (2) the information recovery can be accomplished with much less resources when MEMSL is used than those needed in any non-entangled or non-squeezed classical imaging method. Furthermore, the action of the optical loss in the imaging system that degrades the imaging performance is also rigorously analyzed and presented. Several bioimaging applications that can benefit tremendously from the proposed quantum imaging scheme are also suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband Fourier-Transform Optical Photothermal Infrared Spectroscopy and Imaging

Infrared (IR) spectroscopy is a powerful method for mapping chemical heterogeneity on the microscale. Synchrotron IR radiation uniquely provides a high brightness and broad bandwidth to further extend the capabilities of IR spectroscopic imaging. However, the diffraction-limited spatial resolution of IR spectroscopy is insufficient for studies requiring submicrometer spatial differentiation. Optical photothermal IR (O-PTIR) microscopy is a powerful, emerging method that overcomes the IR diffraction limit in IR hyperspectral imaging by employing a modulated IR beam and a visible probe laser beam to detect local temperature-induced modulation at the visible diffraction limit. In this work, we extend the spectral range of photothermal infrared measurements by incorporating a synchrotron IR source, demonstrating a combined synchrotron-based O-PTIR modality that enables high spatial resolution far-field chemical imaging spanning the entire mid-IR range. Both optical- and fluorescence-detected photothermal modalities were performed using a step-scan interferometer, demonstrating improved spectral range (541-4000 cm-1) when compared to optical photothermal microscopy with commercial laser sources (800-1800 cm-1 for this particular source) and improved spatial resolution, when compared to synchrotron microspectroscopy measurements. Following these initial validation studies, synchrotron Fourier-transform fluorescence-detected photothermal IR spectroscopy in combination with synchrotron microspectroscopy measurements was used to differentiate cells in mouse brain tissue sections, which requires submicron spatial resolutions beyond those accessible by IR spectroscopy alone.

Razumtcev, Aleksandr↗

System and method for obtaining wide screen Schlieren photographs

A system for use in Schlieren photography includes (1) a viewing screen adjacently related to a large grating; (2) a small grating disposed in spaced relation with the large grating; (3) a transparent retainer for confining a transparent medium between the gratings; and (4) optics for imaging the small grating on the large grating. A light source and optically aligned lens are used to project a beam of light along axes extending through the small grating and strike the large grating, subsequent to passing through the medium. A Schlieren image of striations resulting from distortions of light rays proposed by the medium are formed on the screen. A camera is used to photograph the Schlieren image projected on the large screen.

Parthasarathy, S. P.↗

Large Adaptive Optics Survey for Substellar Objects around Young, Nearby, Low-mass Stars with Robo-AO

We present results from the Large Adaptive optics Survey for Substellar Objects, where the goal is to directly image new substellar companions (<70 M {sub Jup}) at wide orbital separations (≳50 au) around young (≲300 Myr), nearby (<100 pc), low-mass (≈0.1–0.8 M{sub ⊙}) stars. We report on 427 young stars imaged in the visible (i') and near-infrared (J or H ) simultaneously with Robo-AO on the Kitt Peak 2.1 m telescope and later the Maunakea University of Hawaii 2.2 m telescope. To undertake the observations, we commissioned a new infrared camera for Robo-AO that uses a low-noise high-speed SAPHIRA avalanche photodiode detector. We detected 121 companion candidates around 111 stars, of which 62 companions are physically associated based on Gaia DR2 parallaxes and proper motions, another 45 require follow-up observations to confirm physical association, and 14 are background objects. The companion separations range from 2 to 1101 au and reach contrast ratios of 7.7 mag in the near-infrared compared to the primary. The majority of confirmed and pending candidates are stellar companions, with ~5 being potentially substellar and requiring follow-up observations for confirmation. We also detected a 43 ± 9 M {sub Jup} and an 81 ± 5 M {sub Jup} companion that were previously reported. We found 34 of our targets have acceleration measurements detected using Hipparcos–Gaia proper motions. Of those, 58{sub -14}{sup +12}% of the 12 stars with imaged companion candidates have significant accelerations (χ{sup 2}>11.8), while only 23{sub -6}{sup +11}% of the remaining 22 stars with no detected companion have significant accelerations. The significance of the acceleration decreases with increasing companion separation. These young accelerating low-mass stars with companions will eventually yield dynamical masses with future orbit monitoring.

47 OTHER INSTRUMENTATION↗

Nonlinear optical thin films

A focused approach to development and evaluation of organic polymer films for use in optoelectronics is presented. The issues and challenges that are addressed include: (1) material synthesis, purification, and the tailoring of the material properties; (2) deposition of uniform thin films by a variety of methods; (3) characterization of material physical properties (thermal, electrical, optical, and electro-optical); and (4) device fabrication and testing. Photonic materials, devices, and systems were identified as critical technology areas by the Department of Commerce and the Department of Defense. This approach offers strong integration of basic material issues through engineering applications by the development of materials that can be exploited as the active unit in a variety of polymeric thin film devices. Improved materials were developed with unprecedented purity and stability. The absorptive properties can be tailored and controlled to provide significant improvement in propagation losses and nonlinear performance. Furthermore, the materials were incorporated into polymers that are highly compatible with fabrication and patterning processes for integrated optical devices and circuits. By simultaneously addressing the issues of materials development and characterization, keeping device design and fabrication in mind, many obstacles were overcome for implementation of these polymeric materials and devices into systems. We intend to considerably improve the upper use temperature, poling stability, and compatibility with silicon based devices. The principal device application that was targeted is a linear electro-optic modulation etalon. Organic polymers need to be properly designed and coupled with existing integrated circuit technology to create new photonic devices for optical communication, image processing, other laser applications such as harmonic generation, and eventually optical computing. The progression from microscopic sample to a suitable film-forming material in a working device is a complex, multifaceted endeavor. It requires close attention to maintaining the optical properties of the electro-optic active portion of the polymer while manipulating the polymer structure to obtain the desired secondary polymer properties.

Leslie, Thomas M.↗