Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗

Neutron Imaging Using Grating Interferometry: Exploiting phase contrast and dark-field imaging for <1μm feature detection in bulk materials (Summary Report)

Radiography is an important non-destructive characterization tool for many LANL missions. Contrast in conventional radiography results from attenuation of the incoming x-ray or neutron beam by the object. Neutrons have a great benefit in detecting light elements (e.g. hydrogen) in the presence of heavier elements and penetrate deeper than X-rays into many materials, but neutron radiography resolution is typically limited to ~50 μm. Cracks, voids, pores and a variety of other features smaller than this resolution are therefore undetectable in attenuation based neutron imaging. However, novel neutron imaging modalities leveraging off of interferometric methods, so-called neutron grating interferometry (NGI), are able to spatially map sub-micron features and interfacial features while also exploiting the neutron’s sensitivity to light elements and isotope specific contrast to enable material characterization otherwise impossible.

36 MATERIALS SCIENCE↗

Active Irradiation Testing of Temperature Sensing Capability of Clad Sapphire Optical Fibers with Type 2 Bragg Gratings using Optical Backscatter Reflectometry

This work investigated the temperature-sensing capabilities of Type II fiber Bragg gratings (FBGs) inscribed in sapphire optical fiber in the Ohio State University Research Reactor (OSURR). A Luna Innovations 4600 optical backscatter reflectometer (OBR) was used to interrogate FBGs in three sapphire optical fibers with an internal cladding that was developed by Ohio State. The sapphire fibers were fusion-spliced to silica lead fibers. In addition to the sapphire fibers, two silica fibers with the same Type II FBGs were included in the experiment as a reference. The fiber-based sensors were irradiated in the Central Irradiation Facility (CIF) of the OSURR for a total of 40 hours over 5 days at a reactor power of 450 kW, resulting in a total neutron fluence of approximately 2.5 × 10 18 n/cm 2 and a gamma dose of approximately 3.48 Grad. Two K-type thermocouples were included within the rig: one at the core centerline and the other 12 inches above the top of the core. The temperature was not actively controlled, but the thermocouples were used to provide a reference to which the fiber-based temperature measurements could be compared.

36 MATERIALS SCIENCE↗

In Situ High Energy X-ray Diffraction Characterization of Phase Transformations and Mechanical Behaviors in Rapidly Solidified Titanium and Stainless Steel Alloys [Thesis]

Advanced manufacturing techniques like additive manufacturing (AM) have poised themselves to revolutionize metal manufacturing. A wide range of AM techniques are capable of manufacturing metal components with unique, complex geometries and hastening the scientific-engineering-development cycle. Metal AM relies on a layer-by-layer rapid manufacturing process to build components from the substrate up. Rapid solidification is a large departure from traditional metal manufacturing due to its complex physics. Characterization of rapid solidification is difficult, stemming from the small volumes used in AM and the fast dynamics of the process. High energy X-ray diffraction (HEXRD) is a solution to the characterization problems of rapidly solidified alloys and AM. HEXRD can probe small volumes at fast rates and provides a wide range of thermomechanical and kinetic information. This thesis presents the application of HEXRD to rapidly solidified titanium and stainless steel alloys through a series of case studies. In the first two studies, HEXRD is applied to rapidly solidified titanium and stainless steel welds. The materials are characterized for their temperature history, phase changes, kinetics, and microstructural evolution. In the next case study, HEXRD is applied to characterize phase changes in elastocaloric NiTi shape memory alloys (SMAs) under thermomechanical load. HEXRD, in conjunction with other tools, is used to explain the superior performance of the additively manufactured SMAs. In the final two case studies, HEXRD is used to measure the mechanical response of AM parts with complex geometries; namely, the octet truss lattice. Diffraction reveals a wide range of materials information about the AM microstructure including unexpected phases, texture, and mechanical response to loading. The mechanical results from HEXRD and then compared with theoretical predictions about the performance of octet truss lattices. Summarily, HEXRD is a diverse tool that is poised to address the complex characterization problems of many aspects of the additive manufacturing process.

36 MATERIALS SCIENCE↗

Data Science and Computation for Rapid and Dynamic Compression Experiment Workflows at Experimental Facilities, September 8-11, 2020. Workshop Report

The application of high pressure to materials has enabled discoveries in scientific fields such as planetary science, materials science, and materials synthesis. Recent advances in X-ray user light sources and other facilities, co-location and integration of user facilities with high-pressure drivers, availability of high-performance computing (HPC) platforms, and the development of new data science techniques have created opportunities for, and challenges in, advancing data analytics for rapid and dynamic compression experiments. To address these challenges, harness the emerging technology now available, and expedite scientific discovery, Los Alamos National Laboratory (LANL) hosted a virtual workshop entitled “Data Science and Computation for Rapid and Dynamic Compression Workflows at Experimental Facilities” from September 8 to 11, 2020. The workshop included 95 registered scientists and analytics experts from 15 universities, 9 United States (US) national laboratories, 5 US and European X-ray light sources, neutron sources such as the Los Alamos Neutron Science Center (LANSCE), other big science facilities such as the National Ignition Facility (NIF), and an industry representative. The workshop included 31 invited talks and 4 lightning talks by students and postdocs.

36 MATERIALS SCIENCE↗

High-Performance/-Precision/-Z(HPPZ) Scintillator Grids via Advanced Electrochemistry. Phase I – Project # 20210572MFR- Mid year review [Slides]

Scintillation grids with improved imaging resolution in time and space, are required for future mission needs at various facilities (pRad user station, LANSCE, DARHT, Scorpius etc). Current technologies use inorganic crystal scintillators, which are positioned within a high-Z scintillator septa. Dense and high-Z materials are optimal for gamma-ray detection making them promising candidates for development of high -performance/-precision/-Z (HPPZ) scintillator grids. The current resolution of standard chemical etching and fabrication processes of high-Z materials is very low, leading to undesired undercutting and ultimately reducing crystal performance efficiency. Goals are to: Perform initial feasibility studies with the aim of producing complex parts for applications with difficult-to-process high-Z material; Use of pulse and pulse-reverse electrochemical methods on additive approaches to produce high-precision Au and Re scintillator grids at a small scale; and, Follow up in Phase II with the delivery of a large-scale scintillator grid of the best material candidate with unprecedented properties for LANL needs determined in Phase I.

36 MATERIALS SCIENCE↗

Completion of Milestone for Receiving Reinstrumentation Equipment from IFE

This set of powerpoint slides demonstrates how milestone "M2CT-21IN0702026: Receive prototype drilling and defueling modules for the re-instrumentation facility procured from the Institute For Energy (Halden, Norway) at the Idaho National Laboratory" was met. It supports an entry in PICS claiming achievement of the milestone. These slides provide a good summary of the purpose and impact of the milestone for our DOE Headquarters colleagues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

p-i-n High-Speed Photodiodes for X-RAY and Infrared Imagers Fabricated by In-Situ -Doped APCVD Germanium Homoepitaxy

Design, simulation, fabrication, and measurement have been performed using a new method for obtaining high-speed p-i-n germanium photodiodes for use in backside imaging arrays. These devices are proof-of-principal in situ-doped vertical mesa structures fabricated using single-wafer, atmospheric-pressure chemical vapor deposition (APCVD) homoepitaxy on Czochralski-grown Ge substrates. Excellent impurity profiles resulting from in situ doping, as measured by spreading-resistance profilometry, were 5 × 10 16 , 2 × 10 15 , and 2 × 10 18 (cm -3 ) for the p-type anode, i-region absorber, and n+ cathode, respectively. Scanning electron microscopy analysis revealed very-low defect densities in the epitaxial layers. The diodes, with diameters ranging 100-500 μm, exhibited excellent ideality (n = 1.15) and less than 1-μA dark current, corresponding to up to 80 kV-cm -1 electric field in the smallest devices. Avalanche breakdown bias was consistently at a magnitude of 50 V or lower. External quantum efficiencies in the near-infrared spectrum peaked at 70%. Pulsed illumination experiments, both in the infrared and X-ray regions, showed pulse rise times in the 100-140 ps range, indicating excellent applicability of this method to high-speed X-ray or infrared applications.

36 MATERIALS SCIENCE↗

Thermal Infrared Detectors: expanding performance limits using ultrafast electron microscopy

This project aimed to identify the performance-limiting mechanisms in mid- to far infrared (IR) sensors by probing photogenerated free carrier dynamics in model detector materials using scanning ultrafast electron microscopy (SUEM). SUEM is a recently developed method based on using ultrafast electron pulses in combination with optical excitations in a pump- probe configuration to examine charge dynamics with high spatial and temporal resolution and without the need for microfabrication. Five material systems were examined using SUEM in this project: polycrystalline lead zirconium titanate (a pyroelectric), polycrystalline vanadium dioxide (a bolometric material), GaAs (near IR), InAs (mid IR), and Si/SiO 2 system as a prototypical system for interface charge dynamics. The report provides detailed results for the Si/SiO 2 and the lead zirconium titanate systems.

36 MATERIALS SCIENCE↗

Investigation of Surface Skidding Response of PBX 9501 and PBX 9502

Introduction: Assess the hazards of handling polymer bonder explosives(PBX) for the case of skidding with grit particles in the frictional interface. High explosive (HE) materials tested: PBX 9501 and 9502. High melting point materials at the skidding interface between HE and a substrate is known to increase the probability of ignition by creating hot spots not subject to reduced heating from the melting of HE material. Skidding occurred at peak forces of 6-26 kN normal force, and 0.6-3.4 kN of frictional force. Velocities for skidding range from 5-30 m/s, see figure 7. Sparse amounts of 300 μm silica grit is applied loosely to the HE surface before testing. Previous works have tested ignition by grit. Testing parameters include angle of impact, drop height, grit size, grit density, substrate material. This study focuses on pre ignition conditions and detailed thermal imaging of the frictional interface. Conclusions: Temperature hot spots were observed at high points in HE surface topology. These high points may be created by grit particles. Since these points impact first high frictional work is concentrated and quickly increases temperature. Small amounts of grit do not affect the overall frictional force but do concentrate the frictional work to create hot spots.

36 MATERIALS SCIENCE↗

Radiation hard Ga 2 O 3 detectors for high energy physics

In this project, we explore the use of ultra-wide bandgap Ga 2 O 3 materials for fabricating next-generation radiation hard solid-state detectors for high energy physics (HEP) applications. As an emerging semiconductor, Ga 2 O 3 has ultra-wide bandgap (4.5-4.9 eV), high breakdown electric field (8 MV/cm) and much lower production cost compared with radiation hard diamond detectors, all of which make Ga 2 O 3 a great candidate material working in harsh radiation environment of future HEP experiments. The recent breakthrough of growth technologies of Ga 2 O 3 significantly improves the availability of large area single crystalline Ga 2 O 3 . We focus on an early proof-of-principle demonstration of Ga 2 O 3 detectors and conduct comprehensive material and detector characterization to evaluate the potential of the emerging Ga 2 O 3 as a new radiation-hard detector material. Our endeavors directly support the instrumentation development and update need of HEP experiments and fits very well into the DOE HEP “Detector R&D” research subprogram.

36 MATERIALS SCIENCE↗

Validation of Printed Strain Gauges at Moderate Temperatures (up to 300°C)

Strain gauges in material test reactors serve to generate critical mechanical property data for qualifying the performance of reactor components. Resistance based strain gauge technologies are both well established and commercially available; however, they present limitations in terms of reactor experiment conditions, especially in areas where physical space is a challenge. In this work, an additively manufactured capacitance-based strain gauge was printed on a stainless-steel specimen and tested at up to the prototypic pressurized-water reactor operating temperature of 300°C. In addition, a high-temperature resistive strain gauge (RSG) was used to better understand how the RSGs operate, and to provide baseline measurements for comparison against the printed strain gauges. Future development of printed strain gauges will focus on expanding their temperature limits to 500°C and enabling applications currently beyond the capabilities of commercial RSGs.

36 MATERIALS SCIENCE↗

Development of Quality Control Methods for Robust and Reliable Sensor Design

The successful adoption of additive manufacturing for the rapid prototyping of printed sensors requires the establishment of quantifiable metrics that can interrogate device performance. One measure of performance is the adhesion strength between the substrate and sensor interface, which is critical since the strength of this interface can dictate the accuracy and reliability of the printed sensor. In this work, a non-contact laser-induced spallation technique was used to quantify the adhesion of silver prints on an aluminum alloy substrate. The laser-based method was compared to a standardized pull-off adhesion test, which provided baseline measurements of adhesion strength. The sintering conditions were shown to play an important role in the film-substrate adhesion strength, as well as the cohesion and ductility of the film itself. The methods and results described in this work supports the establishment of process control steps that are necessary for verifying the reliability of printed devices prior to its deployment in critical experiments.

36 MATERIALS SCIENCE↗