Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiplex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A 220-$\mu$ W –83-dBm 5.8-GHz Third-Harmonic Passive Mixer-First LP-WUR for IEEE 802.11ba

A 40-nm CMOS IEEE 802.11ba low-power wake-up receiver (LP-WUR) is presented. It receives 802.11ba messages generated by an 802.11 orthogonal frequency-division multiplexing (OFDM) transmitter operating at 5.8 GHz. The power consumption of the RF front-end is minimized by removing active RF gain stages and using a third harmonic passive mixer with a ring-based local oscillator (LO) operating at one-third of the RF frequency. The noise figure is 14 dB, taking advantage of a 1:3 transformer that provides passive voltage gain in front of the high switch loss mixer-first RF front-end, and matching across 5.5-5.8 GHz with <; -12 dB S11. Here, the receiver achieves a sensitivity of -83-dBm and -20-dB adjacent channel signal-tointerference ratio (SIR) while consuming 220 μW at a bit error rate (BER) of 10-3 and data rate of 62.5 kb/s, which shows the best sensitivity-power tradeoff among >3-GHz receivers.

42 ENGINEERING↗

Measuring Light Reflectance of BGO Crystal Surfaces

A scintillating crystal's surface reflectance has to be well understood in order to accurately predict and optimize the crystal?s light collection through Monte Carlo simulations. In this paper, we measure the inner surface reflectance properties for BGO. The measurements include BGO crystals with a mechanically polished surface, rough-cut surface, and chemically etched surface, and with various reflectors attached, both air- coupled and with coupling compound. The measurements are performed with a laser aimed at the center of a hemispherical shaped BGO crystal. The hemispherical shape eliminates any non-perpendicular angles for light entering and exiting the crystal. The reflected light is collected with an array of photodiodes. The laser can be set at an arbitrary angle, and the photodiode array is rotated to fully cover 2? of solid angle. The current produced in the photodiodes is readout with a digital multimeter connected through a multiplexer. The two rows of photodiodes achieve 5-degree by 4-degree resolution, and the current measurement has a dynamic range of 10^5:1. The acquired data was not described by the commonly assumed linear combination of specular and diffuse (Lambertian) distributions, except for a very few surfaces. Surface roughness proved to be the most important parameter when choosing crystal setup. The reflector choice was of less importance and of almost no consequence for rough-cut surfaces. Pure specular reflection distribution for all incidence angles was measured for polished surfaces with VM2000 film, while the most Lambertian distribution for any surface finish was measured for titanium dioxide paint. The distributions acquired in this paper will be used to create more accurate Monte Carlo models for light reflection distribution within BGO crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Front-End ASIC for Liquid Argon TPC

We present a front-end application-specific integrated circuit (ASIC) for a wire based time-projection-chamber (TPC) operating in liquid Argon (LAr). The LAr TPC will be used for long baseline neutrino oscillation experiments. The ASIC must provide a low-noise readout of the signals induced on the TPC wires, digitization of those signals at 2 MSamples/s, compression, buffering and multiplexing. A resolution of better than 1000 rms electrons at 200 pF input capacitance for an input range of 300 fC is required, along with low power and operation in LAr (at 87 K). We include the characterization of a commercial technology for operation in the cryogenic environment and the first experimental results on the analog front end. The results demonstrate that complementary metal-oxide semiconductor transistors have lower noise and much improved dc characteristics at LAr temperature. Finally, we introduce the concept of '1/f equivalent' to model the low-frequency component of the noise spectral density, for use in the input metal-oxide semiconductor field-effect transistor optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype Design of Global Common Module for ATLAS Experiment’s Phase-II Upgrade

A new Global Trigger subsystem will be installed in the Level-0 Trigger as part of HL-LHC Upgrade of ATLAS during the upcoming Long-Shutdown 3. It will feature new and improved trigger hardware and algorithms, and an increased maximum output rate of 1 MHz. The Global Trigger will run offline-like trigger algorithms on full-granularity data, gathered from several sub-detectors and trigger-processing subsystems. A single Global Common Module (GCM) hardware is implemented across the Global Trigger system to be used as Multiplexer Processor, Global Event Processor and CTP Interface (gCTPi). This common hardware platform method will minimize the complexity of the firmware and simplify the system design and long-term maintenance. The GCM prototype is an ATCA front form factor board with two Xilinx Virtex UltraScale+ FPGA VU13P and one ZYNQ UltraScale+ FPGA ZU19EG and seventeen 25.78125 Gb/s FireFly duplex optical modules on it. The total power consumption of this board must be less than 350 W, and the temperature of the optical modules should be less than 70 °C in the worst case. The VU13Ps serve as algorithms processor nodes such as MUX, GEP and gCTPi, and the ZU19EG with Peta Linux OS running on it, is used as Command/Control/Readout Unit to configure and monitor the board and communicate with the ATLAS Detector Control System (DCS). The development of an ATCA blade with three large FPGAs and about 200 optical links running at 25Gb/s is a very challenging task, and the successful test results have demonstrated this GCM prototype as an advancement of state-of-the-art electronics module design in HEP experiments. This paper presents the hardware design considerations, functionalities, and performance test results of this GCM prototype.

47 OTHER INSTRUMENTATION↗

OFDM Radar Space-Time Adaptive Processing by Exploiting Spatio-Temporal Sparsity

We propose a sparsity-based space-time adaptive processing (STAP) algorithm to detect a slowly-moving target using an orthogonal frequency division multiplexing (OFDM) radar. We observe that the target and interference spectra are inherently sparse in the spatio-temporal domain. Hence, we exploit that sparsity to develop an efficient STAP technique that utilizes considerably lesser number of secondary data and produces an equivalent performance as the other existing STAP techniques. In addition, the use of an OFDM signal increases the frequency diversity of our system, as different scattering centers of a target resonate at different frequencies, and thus improves the target detectability. First, we formulate a realistic sparse-measurement model for an OFDM radar considering both the clutter and jammer as the interfering sources. Then, we apply a residual sparse-recovery technique based on the LASSO estimator to estimate the target and interference covariance matrices, and subsequently compute the optimal STAP-filter weights. Our numerical results demonstrate a comparative performance analysis of the proposed sparse-STAP algorithm with four other existing STAP methods. Furthermore, we discover that the OFDM-STAP filter-weights are adaptable to the frequency-variabilities of the target and interference responses, in addition to the spatio-temporal variabilities. Hence, by better utilizing the frequency variabilities, we propose an adaptive OFDM-waveform design technique, and consequently gain a significant amount of STAP-performance improvement.

adaptive waveform design.↗

Genotyping‐in‐Thousands by sequencing (GT‐seq): A cost effective SNP genotyping method based on custom amplicon sequencing

Abstract Genotyping‐in‐Thousands by sequencing ( GT ‐seq) is a method that uses next‐generation sequencing of multiplexed PCR products to generate genotypes from relatively small panels (50–500) of targeted single‐nucleotide polymorphisms ( SNP s) for thousands of individuals in a single Illumina HiSeq lane. This method uses only unlabelled oligos and PCR master mix in two thermal cycling steps for amplification of targeted SNP loci. During this process, sequencing adapters and dual barcode sequence tags are incorporated into the amplicons enabling thousands of individuals to be pooled into a single sequencing library. Post sequencing, reads from individual samples are split into individual files using their unique combination of barcode sequences. Genotyping is performed with a simple perl script which counts amplicon‐specific sequences for each allele, and allele ratios are used to determine the genotypes. We demonstrate this technique by genotyping 2068 individual steelhead trout ( Oncorhynchus mykiss ) samples with a set of 192 SNP markers in a single library sequenced in a single Illumina HiSeq lane. Genotype data were 99.9% concordant to previously collected TaqMan ™ genotypes at the same 192 loci, but call rates were slightly lower with GT ‐seq (96.4%) relative to Taqman (99.0%). Of the 192 SNP s, 187 were genotyped in ≥90% of the individual samples and only 3 SNP s were genotyped in <70% of samples. This study demonstrates amplicon sequencing with GT ‐seq greatly reduces the cost of genotyping hundreds of targeted SNP s relative to existing methods by utilizing a simple library preparation method and massive efficiency of scale.

Campbell, Nathan R.↗

Impacts of degraded DNA on restriction enzyme associated DNA sequencing ( RADS eq)

Abstract Degraded DNA from suboptimal field sampling is common in molecular ecology. However, its impact on techniques that use restriction site associated next‐generation DNA sequencing ( RADS eq, GBS ) is unknown. We experimentally examined the effects of in situ DNA degradation on data generation for a modified double‐digest RADS eq approach (3 RAD ). We generated libraries using genomic DNA serially extracted from the muscle tissue of 8 individual lake whitefish ( Coregonus clupeaformis ) following 0‐, 12‐, 48‐ and 96‐h incubation at room temperature posteuthanasia. This treatment of the tissue resulted in input DNA that ranged in quality from nearly intact to highly sheared. All samples were sequenced as a multiplexed pool on an Illumina MiSeq. Libraries created from low to moderately degraded DNA (12–48 h) performed well. In contrast, the number of RAD tags per individual, number of variable sites, and percentage of identical RAD tags retained were all dramatically reduced when libraries were made using highly degraded DNA (96‐h group). This reduction in performance was largely due to a significant and unexpected loss of raw reads as a result of poor quality scores. Our findings remained consistent after changes in restriction enzymes, modified fold coverage values (2‐ to 16‐fold), and additional read‐length trimming. We conclude that starting DNA quality is an important consideration for RADS eq; however, the approach remains robust until genomic DNA is extensively degraded.

Graham, Carly F.↗

Targeted quantification of functional enzyme dynamics in environmental samples for microbially mediated biogeochemical processes: Targeted quantification of functional enzyme dynamics

Microbially mediated biogeochemical processes are catalyzed by enzymes that control the transformation of carbon, nitrogen, and other elements in environment. The dynamic linkage between enzymes and biogeochemical species transformation has, however, rarely been investigated because of the lack of analytical approaches to efficiently and reliably quantify enzymes and their dynamics in soils and sediments. Herein, we developed a signature peptide-based technique for sensitively quantifying dissimilatory and assimilatory enzymes using nitrate-reducing enzymes in a hyporheic zone sediment as an example. Moreover, the measured changes in enzyme concentration were found to correlate with the nitrate reduction rate in a way different from that inferred from biogeochemical models based on biomass or functional genes as surrogates for functional enzymes. This phenomenon has important implications for understanding and modeling the dynamics of microbial community functions and biogeochemical processes in environments. Our results also demonstrate the importance of enzyme quantification for the identification and interrogation of those biogeochemical processes with low metabolite concentrations as a result of faster enzyme-catalyzed consumption of metabolites than their production. The dynamic enzyme behaviors provide a basis for the development of enzyme-based models to describe the relationship between the microbial community and biogeochemical processes.

Li, Minjing↗

Microbial community structure of hydrothermal deposits from geochemically different vent fields along the Mid-Atlantic Ridge

To evaluate the effects of local fluid geochemistry on microbial communities associated with active hydrothermal vent deposits, we examined the archaeal and bacterial communities of 12 samples collected from two very different vent fields: the basalt-hosted Lucky Strike (37 17'N, 32 16.3'W, depth 1600-1750 m) and the ultramafic-hosted Rainbow (36 13'N, 33 54.1'W, depth 2270-2330 m) vent fields along the Mid-Atlantic Ridge (MAR). Using multiplexed barcoded pyrosequencing of the variable region 4 (V4) of the 16S rRNA genes, we show statistically significant differences between the archaeal and bacterial communities associated with the different vent fields. Quantitative polymerase chain reaction (qPCR) assays of the functional gene diagnostic for methanogenesis (mcrA), as well as geochemical modelling to predict pore fluid chemistries within the deposits, support the pyrosequencing observations. Collectively, these results show that the less reduced, hydrogen-poor fluids at Lucky Strike limit colonization by strict anaerobes such as methanogens, and allow for hyperthermophilic microaerophiles, like Aeropyrum. In contrast, the hydrogen-rich reducing vent fluids at the ultramafic-influenced Rainbow vent field support the prevalence of methanogens and other hydrogen-oxidizing thermophiles at this site. These results demonstrate that biogeographical patterns of hydrothermal vent microorganisms are shaped in part by large scale geological and geochemical processes.

58 GEOSCIENCES↗

Evaluation of the FilmArray® system for detection of Bacillus anthracis, Francisella tularensis, and Yersinia pestis

To evaluate the sensitivity and specificity of the Idaho Technologies FilmArray® Biothreat Panel for the detection of Bacillus anthracis (Ba), Francisella tularensis (Ft), and Yersinia pestis (Yp) DNA, and demonstrate the detection of Ba spores. Methods and Results: DNA samples from Ba, Ft and Yp strains and near-neighbors, and live Ba spores were analyzed using the Biothreat Panel, a multiplexed PCR-based assay for 17 pathogens and toxins. Sensitivity studies with DNA suggest a limit of detection of 250 genome equivalents (GEs) per sample. Furthermore, the correct call of Ft, Yp or Bacillus species was made in 63 of 72 samples tested at 25 GE or less. With samples containing 25 Ba Sterne spores, at least one of the two possible Ba markers were identified in all samples tested. We observed no cross-reactivity with near-neighbor DNAs.

Biodetection, PCR, hand portable, pathogens, biote↗

Kinship, inbreeding and fine‐scale spatial structure influence gut microbiota in a hindgut‐fermenting tortoise

Abstract Herbivorous vertebrates rely on complex communities of mutualistic gut bacteria to facilitate the digestion of celluloses and hemicelluloses. Gut microbes are often convergent based on diet and gut morphology across a phylogenetically diverse group of mammals. However, little is known about microbial communities of herbivorous hindgut‐fermenting reptiles. Here, we investigate how factors at the individual level might constrain the composition of gut microbes in an obligate herbivorous reptile. Using multiplexed 16S rRNA gene sequencing, we characterized the faecal microbial community of a population of gopher tortoises ( Gopherus polyphemus ) and examined how age, genetic diversity, spatial structure and kinship influence differences among individuals. We recovered phylotypes associated with known cellulolytic function, including candidate phylum Termite Group 3, suggesting their importance for gopher tortoise digestion. Although host genetic structure did not explain variation in microbial composition and community structure, we found that fine‐scale spatial structure, inbreeding, degree of relatedness and possibly ontogeny shaped patterns of diversity in faecal microbiomes of gopher tortoises. Our findings corroborate widespread convergence of faecal‐associated microbes based on gut morphology and diet and demonstrate the role of spatial and demographic structure in driving differentiation of gut microbiota in natural populations.

Yuan, Michael L.↗

Engineering quantitative stomatal trait variation and local adaptation potential by cis‐regulatory editing

Summary Cis‐regulatory element editing can generate quantitative trait variation that mitigates extreme phenotypes and harmful pleiotropy associated with coding sequence mutations. Here, we applied a multiplexed CRISPR/Cas9 approach, informed by bioinformatic datasets, to generate genotypic variation in the promoter ofOsSTOMAGEN, a positive regulator of rice stomatal density. Engineered genotypic variation corresponded to broad and continuous variation in stomatal density, ranging from 70% to 120% of wild‐type stomatal density. This panel of stomatal variants was leveraged in physiological assays to establish discrete relationships between stomatal morphological variation and stomatal conductance, carbon assimilation and intrinsic water use efficiency in steady‐state and fluctuating light conditions. Additionally, promoter alleles were subjected to vegetative drought regimes to assay the effects of the edited alleles on developmental response to drought. Notably, the capacity for drought‐responsive stomatal density reprogramming instomagenand two cis‐regulatory edited alleles was reduced. Collectively our data demonstrate that cis‐regulatory element editing can generate near‐isogenic trait variation that can be leveraged for establishing relationships between anatomy and physiology, providing a basis for optimizing traits across diverse environments.

Biotechnology & Applied Microbiology↗

Use of an ocular wound chamber for the prevention of exposure keratopathy in a guinea pig model

Abstract Current therapies available to treat and heal ocular surface injuries and periocular burns are frequently inadequate, costly, and labor intensive. To address these limitations, we have employed a flexible, semitransparent ocular wound chamber (OWC) to provide protection as well as a watertight seal to allow for the constant delivery of therapeutics to the ocular surface and surrounding periocular tissue. This study demonstrates the safety and utilization of the OWC on uninjured eyes and in our exposure keratopathy model. For initial safety studies ( N = 3 per group), the eyelids remained intact and the eye uninjured. A blepharotomy ( N = 6 per group) was performed to remove the upper and lower eyelids surrounding the left (OS) eye to create our exposure keratopathy model. Right (OD) eyes served as uninjured controls in all studies. Following OWC placement, 0.5 mL HPMC gel or balanced saline solution (BSS) was injected into the chamber. Animals were monitored daily and fully assessed via white light, fluorescein, and OCT imaging at least through 72 hours post OWC placement. In studies that included a blepharotomy, skin samples were analyzed by multiplex cytokine analysis. Results of safety experiments revealed no significant differences between treatment groups in corneal thickness, fluorescein staining, OCT imaging, or histological eye or skin sections when compared to control eyes. In our exposure keratopathy model, OWC treated eyes showed significantly less fluorescein uptake and also were found to have significantly lower levels of cytokines IL‐13 and IL‐5 in skin samples. These results demonstrate for the first time that treatment using the OWC device is not only safe, but significantly protects against blepharotomy‐induced exposure keratopathy. As a whole, this study advances our overall efforts to develop a feasible solution to treat ocular surface injuries, infections, and periocular burns.

Holt, Andrew W.↗

Model for aspect ratio dependent etch modulated processing

A time-multiplexed, anisotropic, inductively coupled plasma Si deep reactive ion etch process is characterized in terms of the Si macroload, cross-wafer spatial variation, local pattern density, and feature size. The process regime is established as neutral flux limited, in which material transport occurs in the molecular flow to transition flow regimes. For this process regime, a semiempirical, unified analytic model and a numeric model are developed using the Dushman and Clausing vacuum conductance correction factors, respectively, in the Coburn and Winters model of aspect ratio dependent etching. The experimental reaction probability for etching of Si by F was found to be 0.24 for Dushman's factor and 0.22 for Clausing's factor. Each model is validated to {+-}10% against experimental depth data for microdonut and trench test structures and match each other to within 10% for depths of up to 160 {mu}m. The observed depth range is 64 {mu}m at a depth of 160 {mu}m.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ , in vivo , and in operando imaging and spectroscopy of liquids using microfluidics in vacuum

This review offers a succinct overview of the development of a vacuum-compatible microfluidic reactor system for analysis at the liquid vacuum interface (SALVI), and its diverse applications in in situ, in vivo, and in operando imaging of liquid surfaces as well as the air-liquid (a-l), liquid-liquid (l-l), and solid-liquid (s-l) interfaces in the past decade. SALVI is one of the first microfluidics-based reactors that has enabled direct analysis of volatile liquids in vacuum surface tools such as scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Its integration into ambient and vacuum spectroscopy and microscopy is illustrated. Several applications are highlighted including (1) imaging nanoparticles in liquid using in situ SEM; (2) mapping the evolving l-l interface using in situ x-ray absorption spectroscopy and ToF-SIMS; (3) following complex a-l interfacial oxidation reaction products using in situ ToF-SIMS; (4) capturing biological interfaces of cells and microbes via in vivo multimodal and correlative imaging; and (5) monitoring the dynamic solid electrode and liquid electrolyte interface using in operando molecular imaging. Finally, outlook and recommendations are presented. Besides showing the holistic information volume obtained by real-time multiplexed imaging, this review intends to convey the importance of tool development in revolutionizing surface and interface analysis using vacuum platforms previously limited to solid surfaces. Microfluidics is manifested to be not limited to ambient conditions in many examples in this review. Moreover, fundamental interfacial phenomena underpinning mass and charge transfer can now be pursued in real time via innovated chemical imaging and spectroscopy.

42 ENGINEERING↗

Line emission mapper microcalorimeter spectrometer

The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.

47 OTHER INSTRUMENTATION↗

Large arrays of dual-polarized multichroic TES detectors for CMB measurements with the SPT-3G receiver

Now, detectors for cosmic microwave background (CMB) experiments are background limited, so a straightforward alternative to improve sensitivity is to increase the number of detectors. Large arrays of multichroic pixels constitute an economical approach to increasing the number of detectors within a given focal plane area. We present the fabrication of large arrays of dual-polarized multichroic transition-edge-sensor (TES) bolometers for the South Pole Telescope third-generation CMB receiver (SPT-3G). The complete SPT-3G receiver will have 2690 pixels, each with six detectors, allowing for individual measurement of three spectral bands (centered at 95 GHz, 150 GHz and 220 GHz) in two orthogonal polarizations. In total, the SPT-3G focal plane will have 16140 detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a niobium microstrip transmission line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES sensors. Detectors are read out using a 64x frequency domain multiplexing (fMux) scheme. The microfabrication of the SPT-3G detector arrays involves a total of 18 processes, including 13 lithography steps. Together with the fabrication process, the effect of processing on the Ti/Au TES's T-c is discussed. In addition, detectors fabricated with Ti/Au TES films with Tc between 400 mK 560 mK are presented and their thermal characteristics are evaluated. Optical characterization of the arrays is presented as well, indicating that the response of the detectors is in good agreement with the design values for all three spectral bands (95 GHz, 150 GHz, and 220 GHz). The measured optical efficiency of the detectors is between 0.3 and 0.8. Our results discussed here are extracted from a batch of research of development wafers used to develop the baseline process for the fabrication of the arrays of detectors to be deployed with the SPT-3G receiver. Results from these research and development wafers have been incorporated into the fabrication process to get the baseline fabrication process presented here. SPT-3G is scheduled to deploy to the South Pole Telescope in late 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical design of PICO: a concept for a space mission to probe inflation and cosmic origins

The Probe of Inflation and Cosmic Origins (PICO) is a probe-class mission concept currently under study by NASA. PICO will probe the physics of the Big Bang and the energy scale of inflation, constrain the sum of neutrino masses, measure the growth of structures in the universe, and constrain its reionization history by making full sky maps of the cosmic microwave background with sensitivity 80 times higher than the Planck space mission. With bands at 21-799 GHz and arcmin resolution at the highest frequencies, PICO will make polarization maps of Galactic synchrotron and dust emission to observe the role of magnetic fields in Milky Way's evolution and star formation. We discuss PICO's optical system, focal plane, and give current best case noise estimates. The optical design is a two-reflector optimized open-Dragone design with a cold aperture stop. It gives a diffraction limited field of view (DLFOV) with throughput of 910 cm 2 sr at 21 GHz. The large 82 square degree DLFOV hosts 12,996 transition edge sensor bolometers distributed in 21 frequency bands and maintained at 0.1 K. We use focal plane technologies that are currently implemented on operating CMB instruments including three-color multi-chroic pixels and multiplexed readouts. To our knowledge, this is the first use of an open-Dragone design for mm-wave astrophysical observations, and the only monolithic CMB instrument to have such a broad frequency coverage. Finally, with current best case estimate polarization depth of 0.65 μKCMB-arcmin over the entire sky, PICO is the most sensitive CMB instrument designed to date.

79 ASTRONOMY AND ASTROPHYSICS↗