Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Local strain inhomogeneities during electrical triggering of a metal–insulator transition revealed by X-ray microscopy

Electrical triggering of a metal–insulator transition (MIT) often results in the formation of characteristic spatial patterns such as a metallic filament percolating through an insulating matrix or an insulating barrier splitting a conducting matrix. When MIT triggering is driven by electrothermal effects, the temperature of the filament or barrier can be substantially higher than the rest of the material. Using X-ray microdiffraction and dark-field X-ray microscopy, we show that electrothermal MIT triggering leads to the development of an inhomogeneous strain profile across the switching device, even when the material does not undergo a pronounced, discontinuous structural transition coinciding with the MIT. Diffraction measurements further reveal evidence of unique features associated with MIT triggering including lattice distortions, tilting, and twinning, which indicate structural nonuniformity of both low- and high-resistance regions inside the switching device. Such lattice deformations do not occur under equilibrium, zero-voltage conditions, highlighting the qualitative difference between states achieved through increasing temperature and applying voltage in nonlinear electrothermal materials. Electrically induced strain, lattice distortions, and twinning could have important contributions in the MIT triggering process and drive the material into nonequilibrium states, providing an unconventional pathway to explore the phase space in strongly correlated electronic systems.

42 ENGINEERING↗

Self-consistent modeling of electrochemical strain microscopy of solid electrolytes

Electrochemical strain microscopy (ESM) employs a strong electromechanical coupling in solid ionic conductors to map ionic transport and electrochemical processes with nanometer-scale spatial resolution. To elucidate the mechanisms of the ESM image formation, we performed self-consistent numerical modeling of the electromechanical response in solid electrolytes under the probe tip in a linear, small-signal regime using the Boltzmann–Planck–Nernst–Einstein theory and Vegard's law while taking account of the electromigration and diffusion. We identified the characteristic time scales involved in the formation of the ESM response and found that the dynamics of the charge carriers in the tip-electrolyte system with blocking interfaces can be described as charging of the diffuse layer at the tip-electrolyte interface through the tip contact spreading resistance. At the high frequencies used in the detection regime, the distribution of the charge carriers under the tip is governed by evanescent concentration waves generated at the tip-electrolyte interface. The ion drift length in the electric field produced by the tip determines the ESM response at high frequencies, which follows a 1/f asymptotic law. The electronic conductivity, as well as the electron transport through the electrode-electrolyte interface, do not have a significant effect on the ESM signal in the detection regime. The results indicate, however, that for typical solid electrolytes at room temperature, the ESM response originates at and contains information about the very surface layer of a sample, and the properties of the one-unit-cell-thick surface layer may significantly contribute to the ESM response, implying a high surface sensitivity and a high lateral resolution of the technique. On the other hand, it follows that a rigorous analysis of the ESM signals requires techniques that account for the discrete nature of a solid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decoding the shift-invariant data: applications for band-excitation scanning probe microscopy *

A shift-invariant variational autoencoder (shift-VAE) is developed as an unsupervised method for the analysis of spectral data in the presence of shifts along the parameter axis, disentangling the physically-relevant shifts from other latent variables. Using synthetic data sets, we show that the shift-VAE latent variables closely match the ground truth parameters. The shift VAE is extended towards the analysis of band-excitation piezoresponse force microscopy data, disentangling the resonance frequency shifts from the peak shape parameters in a model-free unsupervised manner. The extensions of this approach towards denoising of data and model-free dimensionality reduction in imaging and spectroscopic data are further demonstrated. This approach is universal and can also be extended to analysis of x-ray diffraction, photoluminescence, Raman spectra, and other data sets.

36 MATERIALS SCIENCE↗

Quantitative Structure Determination from Experimental Four-Dimensional Scanning Transmission Electron Microscopy via the Scattering Matrix

Considerable inroads have recently been made on algorithms to determine the sample potential from four-dimensional scanning transmission electron microscopy data from thick samples where multiple scattering cannot be neglected. This paper further develops the scattering matrix approach to such structure determination. Through simulation, we demonstrate how this approach can be modified to better handle partial spatial coherence, unknown probe defocus, and information from the dark field region. By combining these developments we reconstruct the electrostatic potential of a monolithic SrTiO 3 crystal showing good quantitative agreement with the expected structure.

4D STEM↗

Human-in-the-Loop: The Future of Machine Learning in Automated Electron Microscopy

Machine learning (ML) methods are progressively gaining acceptance in the electron microscopy community for de-noising, semantic segmentation, and dimensionality reduction of data post-acquisition. The introduction of the application programming interfaces (APIs) by major instrument manufacturers now allows the deployment of ML workflows in microscopes, not only for data analytics but also for real-time decision-making and feedback for microscope operation. However, the number of use cases for real-time ML remains remarkably small. Furthermore, we discuss some considerations in designing ML-based active experiments and pose that the likely strategy for the next several years will be human-in-the-loop automated experiments (hAE). In this paradigm, the ML learning agent directly controls beam position and image and spectroscopy acquisition functions, and a human operator monitors experiment progression in real and feature space of the system and tunes the policies of the ML agent to steer the experiment toward specific objectives.

47 OTHER INSTRUMENTATION↗

Aberration-corrected scanning transmission electron microscopy: from atomic imaging and analysis to solving energy problems

The new possibilities of aberration-corrected scanning transmission electron microscopy (STEM) extend far beyond the factor of 2 or more in lateral resolution that was the original motivation. The smaller probe also gives enhanced single atom sensitivity, both for imaging and for spectroscopy, enabling light elements to be detected in a Z-contrast image and giving much improved phase contrast imaging using the bright field detector with pixel-by-pixel correlation with the Z-contrast image. Furthermore, the increased probe-forming aperture brings significant depth sensitivity and the possibility of optical sectioning to extract information in three dimensions. This paper reviews these recent advances with reference to several applications of relevance to energy, the origin of the low-temperature catalytic activity of nanophase Au, the nucleation and growth of semiconducting nanowires, and the origin of the eight orders of magnitude increased ionic conductivity in oxide superlattices. Possible future directions of aberration-corrected STEM for solving energy problems are outlined.

47 OTHER INSTRUMENTATION↗

Fingerprints of composite fermion Lambda levels in scanning tunneling microscopy

A composite fermion (CF) is a topological quasiparticle that emerges from a nonperturbative attachment of vortices to electrons in strongly correlated two-dimensional materials. Similar to noninteracting fermions that form Landau levels in a magnetic field, CFs can fill analogous “Lambda” levels, giving rise to the fractional quantum Hall (FQH) effect of electrons. Here, we show that Lambda levels can be directly visualized through the characteristic peak structure in the signal obtained via spectroscopy with scanning tunneling microscopy (STM) on a FQH state. Complementary to transport, which probes the low-energy properties of CFs, we show that high-energy features in STM spectra can be interpreted in terms of Lambda levels. We numerically demonstrate that STM spectra can be accurately modeled using Jain's CF theory. Our results show that STM provides a powerful tool for revealing the anatomy of FQH states and identifying physics beyond the noninteracting CF paradigm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of domain wall pinning on the dynamic behavior of magnetic vortex structures: Time-resolved scanning x-ray transmission microscopy in NiFe thin film structures

Artificial domain wall pinning sites were created in micron-sized thin-film Ni{sub 80}Fe{sub 20} structures, and their influence on the vortex dynamics was investigated by using time-resolved scanning transmission x-ray microscopy. The domain wall pinning sites were introduced by means of focused ion beam etching in the form of antidots. The vortex gyration frequency increased in square-shaped structures but not in similarly modified disk-shaped structures, where no domain walls are present. This demonstrates that the domain wall pinning is causing the increased frequency. The effect is explained by the confinement of the domain wall motion to the portion of the structure that is circumscribed by the antidots and is in agreement with micromagnetic simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Growth direction and morphology of ZnO nanobelts revealed by combining in situ atomic force microscopy and polarized Raman spectroscopy

Control over the morphology and structure of nanostructures is essential for their technological applications, since their physical properties depend significantly on their dimensions, crystallographic structure, and growth direction. A combination of polarized Raman (PR) spectroscopy and atomic force microscopy (AFM) is used to characterize the growth direction, the presence of point defects and the morphology of individual ZnO nanobelts. PR-AFM data reveal two growth modes during the synthesis of ZnO nanobelts by physical vapor deposition. In the thermodynamics-controlled growth mode, nanobelts grow along a direction close to [0001], their morphology is growth-direction dependent, and they exhibit no point defects. In the kinetics-controlled growth mode, nanobelts grow along directions almost perpendicular to [0001], and they exhibit point defects.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Detection of defects buried in metallic samples by scanning microwave microscopy

This paper reports the local detection of buried calibrated metal defects in metal samples by a new experimental technique, scanning microwave microscopy. This technique combines the electromagnetic measurement capabilities of a microwave vector network analyzer with the subnanometer-resolution capabilities of an atomic force microscope. The network analyzer authorizes the use of several frequencies in the range 1-6 GHz, allowing three-dimensional tomographical investigation, which is useful for the detection of bulk defects in metal materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulating contrast inversion in atomic force microscopy imaging with real-space pseudopotentials

Atomic force microscopy (AFM) measurements have reported contrast inversions for systems such as Cu 2 N and graphene that can hamper image interpretation and characterization. In this work, we apply a simulation method based on ab initio real-space pseudopotentials to gain an understanding of the tip-sample interactions that influence the inversion. We find that chemically reactive tips induce an attractive binding force that results in the contrast inversion. We find that the inversion is tip height dependent and not observed when using less reactive CO-functionalized tips.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Picosecond phase-velocity dispersion of hypersonic phonons imaged with ultrafast electron microscopy

We describe the direct imaging—with four-dimensional ultrafast electron microscopy—of the emergence, evolution, dispersion, and decay of photoexcited, hypersonic coherent acoustic phonons in nanoscale germanium wedges. Coherent strain waves generated via ultrafast in situ photoexcitation were imaged propagating with initial phase velocities of up to 35 km/s across discrete micrometer-scale crystal regions. We then observe that, while each wave front travels at a constant velocity, the entire wave train evolves with a time-varying phase-velocity dispersion, displaying a single-exponential decay to the longitudinal speed of sound (5 km/s) and with a mean lifetime of 280 ps. We also find that the wave trains propagate along a single in-plane direction oriented parallel to striations introduced during specimen preparation, independent of crystallographic direction. Elastic-plate modeling indicates the dynamics arise from excitation of a single, symmetric (dilatational) guided acoustic mode. Further, by precisely determining the experiment time-zero position with a plasma-lensing method, we find that wave-front emergence occurs approximately 100 ps after femtosecond photoexcitation, which matches well with Auger recombination times in germanium. We conclude by discussing the similarities between the imaged hypersonic strain-wave dynamics and electron/hole plasma-wave dynamics in strongly photoexcited semiconductors.

36 MATERIALS SCIENCE↗

Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE. The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)

42 ENGINEERING↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

Microscopy with ultraviolet surface excitation (MUSE) enables translation of optical biopsy principles to enhance life science education

The translation of microscopy with ultraviolet surface excitation (MUSE) into a high school science classroom is investigated with the goal of providing a suitable new modality to enhance life science education. A key part of this effort is the development of laboratory exercises that can integrate the advanced capabilities of MUSE into a classroom setting. MUSE utilizes the unique property of ultraviolet light at wavelengths between 250 and 285 nm to propagate about 10 um into tissues, thus illuminating only the top cell layer. Furthermore this illumination is provided by a low-power UV LED source, which enables one to cost-efficiently implement this method into the educational environment. MUSE in education can eliminate the need for premade microscope slides and provide a far more engaging and rewarding experience for students.

47 OTHER INSTRUMENTATION↗

Spectroscopic imaging in electron microscopy

In the scanning transmission electron microscope, multiple signals can be simultaneously collected, including the transmitted and scattered electron signals (bright field and annular dark field or Z-contrast images), along with spectroscopic signals such as inelastically scattered electrons and emitted photons. In the last few years, the successful development of aberration correctors for the electron microscope has transformed the field of electron microscopy, opening up new possibilities for correlating structure to functionality. Aberration correction not only allows for enhanced structural resolution with incident probes into the sub-angstrom range, but can also provide greater probe currents to facilitate mapping of intrinsically weak spectroscopic signals at the nanoscale or even the atomic level. In this issue of MRS Bulletin, we illustrate the power of the new generation of electron microscopes with a combination of imaging and spectroscopy. We show the mapping of elemental distributions at atomic resolution and also the mapping of electronic and optical properties at unprecedented spatial resolution, with applications ranging from graphene to plasmonic nanostructures, and oxide interfaces to biology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Electron Microscopy and Micro analytical technique development and application for Irradiated TRISO Coated Particles from the AGR-1 Experiment

A series of up to seven irradiation experiments are planned for the Advanced Gas Reactor (AGR) Fuel Development and Quantification Program, with irradiation completed at the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) for the first experiment (i.e., AGR-1) in November 2009 for an effective 620 full power days. The objective of the AGR-1 experiment was primarily to provide lessons learned on the multi-capsule test train design and to provide early data on fuel performance for use in fuel fabrication process development and post-irradiation safety testing data at high temperatures. This report describes the advanced microscopy and micro-analysis results on selected AGR-1 coated particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-Situ Liquid Cell Transmission Electron Microscopy of Nanoparticles from Spent Nuclear Fuel

Noble Metal Particles (NMP) that are present in SNF play an important role in the Fuel Matrix Degradation (FMD) Model that is being considered for predicting the release rate of radionuclides from a waste package. Previous characterization of chemically separated NMP from SNF showed that these were well-crystallized nanoparticles containing Mo, Tc, Ru, Rh, and Pd with some evidence of actinides. These same chemically separated particles were re-characterized following 10 years of storage as the separated material in water. Scanning Transmission Electron Microscopy (STEM) analysis revealed that significant alteration had occurred in this material during storage, resulting in the almost complete degradation of the NMP. We hypothesized that radiolytic damaged had occurred in the material. To support these concepts, we synthesized a mixed Ru-Pd nanoparticle and subjected it to irradiation in the electron microscope in an in-situ liquid cell. We demonstrated that intense radiation can lead to the decomposition of these metallic particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗