Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Formation of resonances and anionic fragments upon electron attachment to benzaldehyde

Benzaldehyde is a simple aromatic aldehyde and has a wide range of applications in the food, pharmaceutical, and chemical industries. The positive electron affinity of this compound suggests that low-energy electrons can be easily trapped by neutral benzaldehyde. In the present study, we investigated the formation of negative ions following electron attachment to benzaldehyde in the gas-phase. Calculations on elastic electron scattering from benzaldehyde indicate a π* valence bound state of the anion at -0.48 eV and three π* shape resonances (0.78, 2.48 and 5.51 eV). The excited state spectrum of the neutral benzaldehyde is also reported to complement our findings. Using mass spectrometry, we observed the formation of the intact anionic benzaldehyde at ~0 eV. We ascribe the detection of the benzaldehyde anion to stabilization of the π* valence bound state upon dissociative electron attachment to a benzaldehyde dimer. In addition, we report the cross sections for nine fragment anions formed through electron attachment to benzaldehyde. Investigations carried out with partially deuterated benzaldehyde show that the hydrogen loss is site-selective with respect to the incident electron energy. In addition, we propose several dissociation pathways, backed up by quantum chemical calculations on their thermodynamic thresholds. The threshold calculations also support that the resonances formed at higher energies lead to fragment anions observable by mass spectrometry, whereas the resonances at low electron energies decay only by electron autodetachment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SpectraCodec: A Hilbert curve-based method for encoding metadata in mass spectra for machine learning applications (SpectraCodec) v1

Machine learning approaches to mass spectrometry (MS) data analysis require structured metadata for optimal performance. However, current MS file formats necessitate external metadata sources, creating integration challenges that impede analytical workflows. Here, we present a novel approach for encoding metadata directly within mzML files using one-hot encoding of ASCII characters mapped via Hilbert space-filling curves. This strategy embeds metadata in the first spectrum's m/z-intensity space, ensuring persistence with the primary data, eliminating the need for external metadata files, and maintaining compatibility with existing MS software. We demonstrate that the Hilbert curve mapping efficiently utilizes the two-dimensional spectral space while maintaining robust data recovery. This method offers a practical solution for machine learning applications in mass spectrometry by ensuring metadata and spectral data remain unified through all stages of analysis.

Bowen, Benjamin [Lawrence Berkeley National Labora↗

Guiding the choice of informatics software and tools for lipidomics research applications

Progress in mass spectrometry lipidomics has led to a rapid proliferation of studies across biology and biomedicine. These generate extremely large raw datasets requiring sophisticated solutions to support automated data processing. To address this, numerous software tools have been developed and tailored for specific tasks. However, for researchers, deciding which approach best suits their application relies on ad hoc testing, which is inefficient and time consuming. Here we first review the data processing pipeline, summarizing the scope of available tools. Next, to support researchers, LIPID MAPS provides an interactive online portal listing open-access tools with a graphical user interface. This guides users towards appropriate solutions within major areas in data processing, including (1) lipid-oriented databases, (2) mass spectrometry data repositories, (3) analysis of targeted lipidomics datasets, (4) lipid identification and (5) quantification from untargeted lipidomics datasets, (6) statistical analysis and visualization, and (7) data integration solutions. Detailed descriptions of functions and requirements are provided to guide customized data analysis workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Symbiont-Mediated Protection of Acromyrmex Leaf-Cutter Ants from the Entomopathogenic Fungus Metarhizium anisopliae

Many fungus-growing ants engage in a defensive symbiosis with antibiotic-producing ectosymbiotic bacteria in the genus Pseudonocardia, which help protect the ants’ fungal mutualist from a specialized mycoparasite, Escovopsis. Here, using germfree ant rearing and experimental pathogen infection treatments, we evaluate if Acromyrmex ants derive higher immunity to the entomopathogenic fungus Metarhizium anisopliae from their Pseudonocardia symbionts. We further examine the ecological dynamics and defensive capacities of Pseudonocardia against M. anisopliae across seven different Acromyrmex species by controlling Pseudonocardia acquisition using ant-nonnative Pseudonocardia switches, in vitro challenges, and in situ mass spectrometry imaging (MSI). We show that Pseudonocardia protects the ants against M. anisopliae across different Acromyrmex species and appears to afford higher protection than metapleural gland (MG) secretions. Although Acromyrmex echinatior ants with nonnative Pseudonocardia symbionts receive protection from M. anisopliae regardless of the strain acquired compared with Pseudonocardia-free conditions, we find significant variation in the degree of protection conferred by different Pseudonocardia strains. Additionally, when ants were reared in Pseudonocardia-free conditions, some species exhibit more susceptibility to M. anisopliae than others, indicating that some ant species depend more on defensive symbionts than others. In vitro challenge experiments indicate that Pseudonocardia reduces Metarhizium conidiospore germination area. Our chemometric analysis using matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) reveals that Pseudonocardia-carrying ants produce more chemical signals than Pseudonocardia-free treatments, indicating that Pseudonocardia produces bioactive metabolites on the Acromyrmex cuticle. Our results indicate that Pseudonocardia can serve as a dual-purpose defensive symbiont, conferring increased immunity for both the obligate fungal mutualist and the ants themselves.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Measuring the Chemical Potential of the Martian Regolith to Generate and Sustain Life

A critical component for identifying chemical biosignatures is the ability to assess in-situ the potential of an aqueous geochemical environment to generate and sustain life. On Mars or other solar bodies, in-situ chemical characterization could provide evidence as to whether the chemical composition of the regolith or evaporites in suspected ancient water bodies have been biologically influenced or possess the chemical parameters within which life may have existed, or may still exist. A variety of analytical techniques have been proposed for use in detecting and identify signatures of past or present life. These techniques fall into two groups; visual observation with instruments such as cameras or optical/atomic-force microscopes; or elemental chemical analysis with such instruments as X-ray fluorescence (XRF) and diffraction (XRD), a-proton backscatter (APX), y-ray, Mossbauer, Raman, IR, UV/VIS spectroscopies, gas chromatography (GC), or mass spectrometry (MS). Direct observation of an identifiable lifeform by the first set of instruments in a single sample is highly unlikely, especially for extinct organisms or on the surface. The later instruments can provide vital data as to the elemental mineralogy and geological history of the planet, but are highly inadequate for understanding the chemistry of the planet in terms of indigenous life or interactions with human explorers. Techniques such as XRD, XRF, and APX, provide elemental composition at high limits of detection. Some of this data can be extrapolated or interpolated to provide chemical parameters such as oxidation state or composition. Gas chromatography (GC) without standards and non-specific detectors, has little chance of identifying a mixture of unknown components. Combined with GC or by itself, mass spectrometry (MS) can provide identification of compounds, but in both cases the sample must be appropriately prepared for accurate and reliable analysis. Life as we know it, and probably identify it as such, requires an aqueous environment. Deciphering die chemical speciation of this aqueous environment is the key to recognizing therein the biosignatures of any extinct or present life forms. Identifying the soluble (ionic and nonionic) components by reacting a currently dormant environment can provide a "picture" of the thermodynamics and chemical components of a possibly bioactive environment. The only devices which can provide such information are electrochemical sensors based on the potentiometric ion selective electrodes (ISEs) and on dynamic techniques such as cyclic voltammetry (CV) and stripping voltammetry (SV). Such an array of devices can provide not only the chemical composition of a water-soluble Martian soil sample, but also several other vital chemical parameters such as pH, conductivity, redox potential, and dissolved gases. To address these issues we have been investigating the possible use of an electrochemically-based ion sensor array as a new integrated approach to quantitative analytical and chemometric electrochemical measurements. The sensor array will consist of specific and semispecific ion selective and amperometric transducers, which can simultaneously and continuously identify and semiquantitatively determine over 50 organic and inorganic analytes in water-based environments. Several individual sensors, based on the same principle, have been flight-tested and have been installed as part of the MECA instrumentation on the Mars 2001 Lander for in-situ analyses. However, the microfabrication, integration and multiplexing of such a large number of these sensors on a single substrate have not been previously attempted.

Kounaves, S. P.↗

Fast Determination of Lithium Content in Spent Cathodes for Direct Battery Recycling

Determination of the lithium ion content in cathode materials, which is currently performed by inductively coupled plasma mass spectrometry (ICP-MS), involves tedious procedures and error-prone preparation. This work introduces a new methodology to quickly determine the lithium content in spent cathode materials (LiNix Mny Coz O2, x + y + z = 1, NMC) using a thermalgravimetric analysis, which bypasses the use of ICP-MS and significantly reduces the cost and time required for determining the lithium content. Based on this new method, a new approach is developed to identify spent cathode materials suitable for direct relithiation recycling. Finally, these new methods have been applied to investigate the effectiveness of direct electrochemical-relithiation on recycling the spent cathodes, and provide insights for future development of direct battery materials recycling.

cathode recycling↗

Thermodynamics of the potassium-sulfur-oxygen and related systems

The chemical reactions which occur when potassium sulfide, K2S, and potassium sulfite, K2SO3, are heated at temperatures where their vapor pressures are significant, were studied and the vapor pressures and the partial pressures of the chemical products were measured. Mass spectrometry of the vapor of potassium sulfide revealed only K(g). X-ray studies of the solid residues from vaporization experiments revealed K2S2(s) and chemical analyses of the same solid residues showed that the residues approached a composition K2Sx with x in the range 3-4. Vapor pressure of K2S was measured by simultaneous Knudsen-effusion and torsion-effusion (SKETE) in crucibles of aluminum oxide and of graphite. In each such experiment, the vapor pressures agreed initially, but then the apparent pressure by Knudsen-effusion increased suddenly and remained much greater than that by torsion-effusion for the remainder of the experiment. Results of third-law analysis of the torsion pressures imply a delta H (298K) of formation of K2S(s) of -364 + or - 12 kJ/mol. Vapor pressures over K2SO3(s) were measured by simultaneous Knudsen and torsion-effusion and by mass spectrometry. The vapor pressures of both K2S2O5(s) and K2SO3(s) were nonreproducible at a given temperature due to the vaporization reactions of the materials being irreversible under conditions in effusion cells.

Edwards, J. G.↗

Use Of The Operational Air Quality Monitor (AQM) For In-Flight Water Testing Project

A primary requirement for manned spaceflight is Environmental Health which ensures air and water contaminants, acoustic profiles, microbial flora, and radiation exposures within the cabin are maintained to levels needed for crew health and for vehicle system functionality. The reliance on ground analyses of returned samples is a limitation in the current environmental monitoring strategy that will prevent future Exploration missions beyond low-Earth orbit. This proposal attempts to address this shortcoming by advancing in-flight analyses of water and air. Ground analysis of in-flight, air and water samples typically employ vapor-phase analysis by gas chromatography-mass spectrometry (GC-MS) to identify and quantify organic compounds present in the samples. We envision the use of newly-developed direct ionization approaches as the most viable avenue leading towards an integrated analytical platform for the monitoring of water, air, and, potentially bio-samples in the cabin environment. Development of an in-flight instrument capable of analyzing air and water samples would be the logical next step to meeting the environmental monitoring needs of Exploration missions. Currently, the Air Quality Monitor (AQM) on-board ISS provides this specific information for a number of target compounds in the air. However, there is a significant subset of common target compounds between air and water. Naturally, the following question arises, "Can the AQM be used for both air and water quality monitoring?" Previous directorate-level IR&D funding led to the development of a water sample introduction method for mass spectrometry using electrothermal vaporization (ETV). This project will focus on the integration of the ETV with a ground-based AQM. The capabilities of this integrated platform will be evaluated using a subset of toxicologically important compounds.

Macatangay, Ariel↗

The Spatial Distribution of Soluble Organic Matter and Their Relationship to Minerals in the Asteroid (162173) Ryugu

We performed in-situ analysis on a ~1 mm-sized grain A0080 returned by the Hayabusa2 spacecraft from near-Earth asteroid (162173) Ryugu to investigate the relationship of soluble organic matter (SOM) to minerals. Desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) imaging mapped more than 200 CHN, CHO, CHO–Na (sodium adducted), and CHNO soluble organic compounds. A heterogeneous spatial distribution was observed for different compound classes of SOM as well as among alkylated homologues on the sample surface. The A0080 sample showed mineralogy more like an Ivuna-type (CI) carbonaceous chondrite than other meteorites. It contained two different lithologies, which are either rich (lithology 1) or poor (lithology 2) in magnetite, pyrrhotite, and dolomite. CHN compounds were more concentrated in lithology 1 than in lithology 2; on the other hand, CHO, CHO–Na, and CHNO compounds were distributed in both lithologies. Such different spatial distribution of SOM is likely the result of interaction of the SOM with minerals, during precipitation of the SOM via fluid activity, or could be due to difference in transportation efficiencies of SOMs in aqueous fluid. Organic-related ions measured by time-of-flight secondary ion mass spectrometry (ToF–SIMS) did not coincide with the spatial distribution revealed by DESI-HRMS imaging. This result may be because the different ionization mechanism between DESI and SIMS, or indicate that the ToF–SIMS data would be mainly derived from methanol-insoluble organic matter in A0080. In the Orgueil meteorite, such relationship between altered minerals and SOM distributions was not observed by DESI-HRMS analysis and field-emission scanning electron microscopy, which would result from differences of SOM formation processes and sequent alteration process on the parent bodies or even on the Earth. Alkylated homologues of CHN compounds were identified in A0080 by DESI-HRMS imaging as observed in the Murchison meteorite, but not from the Orgueil meteorite. These compounds with a large C number were enriched in Murchison fragments with abundant carbonate grains. In contrast, such relationship was not observed in A0080, implying different formation or growth mechanisms for the alkylated CHN compounds by interaction with fluid and minerals on the Murchison parent body and asteroid Ryugu.

Ryugu↗

Siloxyaluminate and Siloxygallate Complexes as Models for Framework and Partially Hydrolyzed Framework Sites in Zeolites and Zeotypes.

Anionic molecular models for nonhydrolyzed and partially hydrolyzed aluminum and gallium framework sites on silica, M[OSi(OtBu) 3 ] 4 - and HOM[OSi(OtBu) 3 ] 3 - (where M=Al or Ga), were synthesized from anionic chlorides Li{M[OSi(OtBu) 3 ] 3 Cl} in salt metathesis reactions. Sequestration of lithium cations with [12]crown-4 afforded charge-separated ion pairs composed of monomeric anions M[OSi(OtBu) 3 ] 4 - with outer-sphere [([12]crown-4) 2 Li] + cations, and hydroxides {HOM[OSi(OtBu) 3 ] 3 } with pendant [([12]crown-4)Li] + cations. These molecular models were characterized by single-crystal X-ray diffraction, vibrational spectroscopy, mass spectrometry and NMR spectroscopy. Upon treatment of monomeric [([12]crown-4)Li]{HOM[OSi(OtBu) 3 ] 3 } complexes with benzyl alcohol, benzyloxide complexes were formed, modeling a possible pathway for the formation of active sites for Meerwin-Ponndorf-Verley (MPV) transfer hydrogenations with Al/Ga-doped silica catalysts.

Dombrowski, James P↗

How nitrogen and oxygen shape SRF cavity performance

Nitrogen and oxygen-based surface treatments have revolutionized the performance of superconducting radiofrequency (SRF) cavities, enabling them to reach higher gradients and lower losses. However, the exact mechanisms by which these treatments improve cavity performance remain largely unknown. This work provides new insights into the role of nitrogen and oxygen in SRF cavity performance by using time-of-flight secondary ion mass spectrometry (TOF-SIMS) to precisely quantify the concentrations and depth profiles of these impurities within niobium cutouts. We correlate these impurity profiles with detailed cavity performance measurements, including surface resistance and quality factor, and compare our findings with predictions from BCS theory. The results demonstrate that while both nitrogen and oxygen enhance performance, ten times more oxygen is required to achieve the same reduction in BCS resistance as interstitial nitrogen. We present a potential model in which the observed variation arises from nitrogen's greater effectiveness in trapping hydrogen, thus reducing the formation of niobium hydrides and enhancing superconducting gap.

Hu, Hannah [Chicago U.]↗

Measurements and computational analysis of the natural decay of 176 Lu

Background: Mainly because of its long half-life and despite its scientific relevance, spectroscopic measurements of 176 Lu forbidden β decays are very limited and lack formulation of shape factors. A direct precise measurement of its Q value is also presently unreported. In addition, the description of forbidden decays provides interesting challenges for nuclear theory. The comparison of precise experimental results with theoretical calculations for these decays can help to test underlying models and can aid the interpretation of data from other experiments. Purpose: Perform the first precision measurements of 176 Lu β-decay spectra and attempt the observation of its electron capture decays, as well as perform the first precision direct measurement of the 176 Lu β-decay Q value. Compare the shape of the precisely determined experimental β spectra to theoretical calculations, and compare the end point energy to that obtained from an independent Q value measurement. Method: Here, the 176 Lu β-decay spectra measurements and the search for electron capture decays were performed with an experimental setup that employed lutetium-containing scintillator crystals and a NaI(Tl) spectrometer for coincidence counting. The β decay Q value was determined via high-precision Penning trap mass spectrometry (PTMS) with the LEBIT facility at the National Superconducting Cyclotron Laboratory. The β-spectrum calculations were performed within the Fermi theory formalism with nuclear structure effects calculated using a shell model approach. Results: Both β transitions of 176 Lu were experimentally observed and corresponding shape factors formulated in their entire energy ranges. The search for electron capture decay branches led to an experimental upper limit of 6.3×10 –6 relative to its β decays. The 176 Lu β-decay and electron capture Q values were measured using PTMS to be 1193.0(6) and 108.9(8) keV, respectively. This enabled precise β end point energies of 596.2(6) and 195.3(6) keV to be determined for the primary and secondary β decays, respectively. The conserved vector current hypothesis was applied to calculate the relativistic vector matrix elements. The β-spectrum shape was shown to significantly depend on the Coulomb displacement energy and on the value of the axial vector coupling constant gA, which was extracted according to different assumptions. Conclusion: The implemented self-scintillation method has provided unmatched observations of 176 Lu, independently validated by the first direct measurements of its β-decay Q value by Penning trap mass spectrometry. Theoretical study of the main β transition led to the extraction of very different effective gA and log10f values, showing that a high-precision description of this transition would require a realistic nuclear structure with nucleus deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mapping the Temperature-dependent and network site-specific onset of spectral diffusion at the surface of a water cluster cage

We explore the kinetic processes that sustain equilibrium in a microscopic, finite system. This is accomplished by monitoring the spontaneous, time-dependent frequency evolution (the frequency autocorrelation) of a single OH oscillator, embedded in a water cluster held in a temperature-controlled ion trap. The measurements are carried out by applying two-color, IR-IR photodissociation mass spectrometry to the D3O+?(HDO)(D2O)19 isotopologue of the “magic number” protonated water cluster, H+?(H2O)21. The OH group can occupy any one of the five spectroscopically distinct sites in the distorted pentagonal dodecahedron cage structure. The OH frequency is observed to evolve over tens of milliseconds in the temperature range (90-120 K). Starting at 100 K, large “jumps” are observed between two OH frequencies separated by ~300 cm-1 indicating migration of the OH group from the bound OH site at 3350 cm-1 to the free position at 3686 cm-1. Increasing the temperature to 110 K leads to partial interconversion among many sites. All sites are observed to interconvert at 120 K such that the distribution of the unique OH group among them adopts the form one would expect for a canonical ensemble. The spectral dynamics displayed by the clusters thus offer an unprecedented view into the molecular-level processes that drive spectral diffusion in an extended network of water molecules.

Yang, Nan↗

Isolating p- and n-Doped Fingers With Intrinsic Poly-Si in Passivated Interdigitated Back Contact Silicon Solar Cells

Polycrystalline silicon on silicon oxide (poly-Si/SiO x ) passivating contacts enable ultra high efficiency interdigitated back contact silicon solar cells. To prevent shunt between n- and p-type doped fingers, an insulating region is required between them. We evaluate the use of intrinsic poly Si for this isolation region. Interdigitated fingers were formed by plasma deposition of doped hydrogenated amorphous silicon through mechanically aligned shadow masks, on top of a full-area intrinsic amorphous silicon layer. High temperature annealing then crystallized the a-Si:H to poly Si and drove in the dopants. Two mechanisms were identified which cause contamination of the intrinsic poly Si gap during processing. During deposition of doped fingers, we show using secondary ion mass spectrometry and conductivity measurements that the intrinsic gap becomes contaminated by doped a-Si:H tails several nanometers thick to concentrations of ~10 20 cm -3 . Another source of contamination occurs during high-temperature annealing, where dopants desorb from doped regions and readsorb onto intrinsic a Si:H. Both pathways reduce the resistivity of the intrinsic gap from ~10 5 Ω·cm to ~10 -1 Ω·cm. We show that plasma etching of the a-Si:H surface before crystallizing with a capping layer can eliminate the contamination of the intrinsic poly-Si, maintaining a resistivity of ~10 5 Ω·cm. Lastly, this demonstrates masked plasma deposition as a dopant patterning method for Si solar cells.

14 SOLAR ENERGY↗

High throughput single cell multiomics platform [Abstract]

In this collaborative project, PNNL and Scienion will co-develop an integrated microfluidic technology to co-measure the transcriptome and proteome in single cells. The technology will enable us to efficiently separate proteins from mRNA transcripts between two microchips, barcode the molecules, and measure them separately with next-generation sequencing and mass spectrometry, respectively. Multicellular organisms contain diverse cell types and tremendous cell-to-cell heterogeneity that dictates a multitude of biological functions in both physiological and pathological environments. Even in the case of microbes, these genetically identical organisms can randomly differentiate into many subpopulations that assume different roles for the survival of the community. Bulk-scale measurements are insufficient to resolve such complexities. The development and applications of high throughput single-cell omics technologies have transformed our understanding of cellular heterogeneities and their differential responses to internal signaling events or external stimulations. Despite these advances, most current single-cell omic technologies provide information on only one type of biomolecule. Perse, such measurements provide incomplete information because the cell phenotype is determined by multiple layers of biomolecules and the interplay between genome, epigenome, transcriptome, and proteome. For example, mRNA abundance in one cell can not be precisely referred to the corresponding DNA and protein in other cells because of the potential subtle difference in genotype (e.g., somatic mutation or copy number variation) or phenotype (external microenvironment and cell-cell interactions). As such, parallel measurement of multiple biomolecules in the same single cells can offer unique advantages compared with measuring them separately in different single cells. Scienion is a world-leading biotech company focusing on precision liquid handling and its application in single-cell whole-genome sequencing and RNA sequencing. PNNL is the leading institution in ultrasensitive mass spectrometry, microfluidics, and untargeted single-cell proteomics (scProteomics). This collaboration will facilitate a unique fusion between scTranscriptomics capability at Scienion and scProteomics capabilities at PNNL to, for the first time, perform both untargeted transcriptomics and proteomics from the same single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Deducing the N- and O-glycosylation profile of the spike protein of novel coronavirus SARS-CoV-2

The current emergence of the novel coronavirus pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) demands the development of new therapeutic strategies to prevent rapid progress of mortalities. The coronavirus spike (S) protein, which facilitates viral attachment, entry and membrane fusion is heavily glycosylated and plays a critical role in the elicitation of the host immune response. The spike protein is comprised of two protein subunits (S1 and S2), which together possess 22 potential N-glycosylation sites. Herein, we report the glycosylation mapping on spike protein subunits S1 and S2 expressed on human cells through high-resolution mass spectrometry. We have characterized the quantitative N-glycosylation profile on spike protein and interestingly, observed unexpected O-glycosylation modifications on the receptor-binding domain of spike protein subunit S1. Even though O-glycosylation has been predicted on the spike protein of SARS-CoV-2, this is the first report of experimental data for both the site of O-glycosylation and identity of the O-glycans attached on the subunit S1. Our data on the N- and O-glycosylation are strengthened by extensive manual interpretation of each glycopeptide spectra in addition to using bioinformatics tools to confirm the complexity of glycosylation in the spike protein. Here, the elucidation of the glycan repertoire on the spike protein provides insights into the viral binding studies and more importantly, propels research toward the development of a suitable vaccine candidate.

59 BASIC BIOLOGICAL SCIENCES↗