Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Polymer-Based Thermally Stable Chemiresistive Sensor for Real-Time Monitoring of NO 2 Gas Emission

Here, we present a thermally stable, mechanically compliant, and sensitive polymer-based NO 2 gas sensor design. Interconnected nanoscale morphology driven from spinodal decomposition between conjugated polymers tethered with polar side chains and thermally stable matrix polymers offers judicious design of NO 2 -sensitive and thermally tolerant thin films. The resulting chemiresitive sensors exhibit stable NO 2 sensing even at 170 °C over 6 h. Controlling the density of polar side chains along conjugated polymer backbone enables optimal design for coupling high NO 2 sensitivity, selectivity, and thermal stability of polymer sensors. Lastly, thermally stable films are used to implement chemiresistive sensors onto flexible and heat-resistant substrates and demonstrate a reliable gas sensing response even after 500 bending cycles at 170 °C. Such unprecedented sensor performance as well as environmental stability are promising for real-time monitoring of gas emission from vehicles and industrial chemical processes.

47 OTHER INSTRUMENTATION↗

Optical Fiber Sensor with a Hydrophobic Filter Layer for Monitoring Hydrogen under Humid Conditions

Real-time and remote monitoring of hydrogen concentration in underground hydrogen storage reservoirs is crucial to maintaining the integrity and safety of the storage facilities. High humidity in the underground deposits interferes with hydrogen sensors, introducing inaccuracy into the hydrogen sensing measurements. A hydrophobic filter layer over a hydrogen sensing layer on an optical fiber hydrogen sensor was devised to minimize the impact of the humidity on the sensor. The hydrogen sensor coated with a hydrophobic filter layer demonstrated a significant improvement in reliable hydrogen sensing under high humidity conditions (99% RH) without severe baseline drift and reduction of transmission intensity. Finally, the optical fiber hydrogen sensor revamped with the filter layer would enable the reliable measurement of hydrogen concentration under the humid conditions expected in subsurface hydrogen storage facilities.

08 HYDROGEN↗

Time-Evolving Chirality Loss in Molecular Photodissociation Monitored by X-ray Circular Dichroism Spectroscopy

In this work, the ultrafast photoinduced chirality loss of 2-iodobutane is studied theoretically by time- and frequency-resolved X-ray circular dichroism (TRXCD) spectroscopy. Following an optical excitation, the iodine atom dissociates from the chiral center, which we capture by quantum non-adiabatic molecular dynamics simulations. At variable time delays after the pump, the resonant X-ray pulse selectively probes the iodine and carbon atom involved in the chiral dissociation through a selected core-to-valence transition. The TRXCD signal at the iodine L 1 edge accurately captures the timing of C–I photodissociation and thereby chirality loss, c.a 70 fs. The strong electric dipole–electric quadrupole (ED–EQ) response makes this signal particularly sensitive to vibronic coherence at the high X-ray regime. At the carbon K-edges, the signals monitor the molecular chirality of the 2-butyl radical photoproduct and the spin state of the iodine atom. The ED–EQ response is masked under the strong electric dipole-magnetic dipole response, making this signal intuitive for the electronic population. The evolution of the core electronic states and its chiral sensitivity is discussed. Overall, the element-specific TRXCD signal provides a detailed picture of molecular dynamics and offers a unique sensitive window into the time-dependent chirality of molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Telomerase-Activated Magnetic Resonance Imaging Probe for Consecutively Monitoring Tumor Growth Kinetics and In Situ Screening Inhibitors

Telomerase has long been considered as a biomarker for cancer diagnosis and a therapeutic target for drug discovery. Detecting telomerase activity in vivo could provide more direct information of tumor progression and response to drug treatment, which, however, is hampered by the lack of an effective probe that can generate an output signal without a tissue penetration depth limit. Here in this study, using the principle of distance-dependent magnetic resonance tuning, we constructed a telomerase-activated magnetic resonance imaging probe (TAMP) by connecting superparamagnetic ferroferric oxide nanoparticles (SPFONs) and paramagnetic Gd-DOTA (Gd(III) 1,4,7,10- tetraazacyclododecane-1,4,7,10-tetraazacyclododecane-1,4,7,10-tet-raacetic acid) complexes via telomerase-responsive DNA motifs. Upon telomerase-catalyzed extension of the primer in TAMP, Gd-DOTA-conjugated oligonucleotides can be liberated from the surface of SPFONs through a DNA strand displacement reaction, restoring the T 1 signal of the Gd-DOTA for a direct readout of the telomerase activity. Here we show that, by tracking telomerase activity, this probe provides consistent monitoring of tumor growth kinetics during progression and in response to drug treatment and enables in situ screening of telomerase inhibitors in whole-animal models. This study provides an alternative toolkit for cancer diagnosis, treatment response assessment, and anticancer drug screening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Covalent Drug Binding in Live Cells Monitored by Mid-Infrared Quantum Cascade Laser Spectroscopy: Photoactive Yellow Protein as a Model System

The detection of drug-target interactions in live cells enables analysis of therapeutic compounds in a native cellular environment. Recent advances in spectroscopy and molecular biology have facilitated the development of genetically encoded vibrational probes like nitriles that can sensitively report on molecular interactions. Nitriles are powerful tools for measuring electrostatic environments within condensed media like proteins, but such measurements in live cells have been hindered by low signal-to-noise ratios. In this study, we design a spectrometer based on a double-beam quantum cascade laser (QCL)-based transmission infrared (IR) source with balanced detection that can significantly enhance sensitivity to nitrile vibrational probes embedded in proteins within cells compared to a conventional FTIR spectrometer. Here, using this approach, we detect small-molecule binding in Escherichia coli, with particular focus on the interaction between para-Coumaric acid (pCA) and nitrile-incorporated photoactive yellow protein (PYP). This system effectively serves as a model for investigating covalent drug binding in a cellular environment. Notably, we observe large spectral shifts of up to 15 cm –1 for nitriles embedded in PYP between the unbound and drug-bound states directly within bacteria, in agreement with observations for purified proteins. Such large spectral shifts are ascribed to the changes in the hydrogen-bonding environment around the local environment of nitriles, accurately modeled through high-level molecular dynamics simulations using the AMOEBA force field. Our findings underscore the QCL spectrometer’s ability to enhance sensitivity for monitoring drug–protein interactions, offering new opportunities for advanced methodologies in drug development and biochemical research.

chromophores↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

Electrical Properties of Carbon Dioxide Hydrate: Implications for Monitoring CO 2 in the Gas Hydrate Stability Zone

CO 2 and CH 4 clathrate hydrates are of keen interest for energy and carbon cycle considerations. While both typically form on Earth as cubic structure I (sI), we find that pure CO 2 hydrate exhibits over an order of magnitude higher electrical conductivity ( σ ) than pure CH 4 hydrate at geologically relevant temperatures. In this study, the conductivity was obtained from frequency-dependent impedance ( Z ) measurements made on polycrystalline CO 2 hydrate (CO 2 ·6.0 ± 0.2H 2 O by methods here) with 25% gas-filled porosity, compared with CH 4 hydrate (CH 4 ·5.9H 2 O) formed and measured in the same apparatus and exhibiting closely matching grain characteristics. The conductivity of CO 2 hydrate is 6.5 × 10 –4 S/m at 273K with an activation energy ( E a ) of 46.5 kJ/mol at 260–281 K, compared with ~5 × 10 –5 S/m and 34.8 kJ/m for CH 4 hydrate. Equivalent circuit modeling indicates that different pathways govern conduction in CO 2 versus CH 4 hydrate. Results show promise for use of electromagnetic methods in monitoring CO 2 hydrate formation in certain natural settings or in CO 2 /CH 4 exchange efforts.

58 GEOSCIENCES↗

Multivariate Drought Monitoring, Propagation, and Projection Using Bias-Corrected General Circulation Models

Understanding how droughts are characterized, propagated, and projected, particularly multivariate droughts, is necessary to explain the variability and changes in drought characteristics. This study aims to understand multimodel global drought monitoring, propagation, and projection by utilizing a multivariate standardized drought index (MSDI) during the historical (1959–2014) and future (2045–2100) periods under two socioeconomic pathways SSPs (370 and 585), derived from the bias-corrected Coupled Model Intercomparison Project Phase 6 (CMIP6). Based on the energy metrics, the multivariate bias correction method outperformed other techniques in correcting the biases in the CMIP6 drought representation. The drought indicators demonstrate distinct categories for meteorological, hydrological, and multivariate droughts. There were significant high cross correlations between Heatwave Total Length (HWTL) and MSDI in Africa and South America for all lagged times. Europe and North America generally saw the maximum MSDI drought duration (228 months) during the historical period. For future projections, Africa recorded the maximum drought duration (197 months), while Europe witnessed the minimum drought duration for SSP 370 (171 months), and North America (149 months) for SSP 585. Furthermore, during the historical period in tropical Africa, the propagation of meteorological to hydrological drought was slower during the wet months than during the dry months. Under the SSP 370 future projection, there was a shift in the long period of meteorological-hydrological propagation from the middle and late wet months to the beginning of the wet months in tropical Africa. Therefore, tracking and projecting drought characteristics is vital for understanding the risk of drought-related consequences.

54 ENVIRONMENTAL SCIENCES↗

Monitoring Seismic Velocity Changes Across the San Jacinto Fault Using Train‐Generated Seismic Tremors

Abstract Microseismic noise has been used for seismic velocity monitoring. However, such signals are dominated by low‐frequency surface waves that are not ideal for detecting changes associated with small tectonic processes. Here we show that it is possible to extract stable, high‐frequency body waves using seismic tremors generated by freight trains. Such body waves allow us to focus on small velocity perturbations in the crust with high spatial resolution. We report on 10 years of seismic velocity temporal changes at the San Jacinto Fault. We observe and map a two‐month‐long episode of velocity changes with complex spatial distribution and interpret the velocity perturbation as produced by a previously undocumented slow‐slip event. We verify the hypothesis through numerical simulations and locate this event along a fault segment believed to be locked. Such a slow‐slip event stresses its surroundings and may trigger a major earthquake on a fault section approaching failure.

58 GEOSCIENCES↗

Monitoring Seasonal Shear Wave Velocity Changes in the Top 6 m at Garner Valley in Southern California With Borehole Data

Abstract Subsurface structures play important roles in seismic ground motion, crustal hydrology, stability of the built environment, and more. Constraining temporal changes of subsurface shear wave velocity ( V S ) can provide useful information to all these topics and the growing field of hydrological monitoring with seismic velocity. Using borehole records at Garner Valley, CA, we estimate seasonal subsurface V S variations from impulse response functions (IRFs) of earthquake data (2005–2018) along with IRFs and cross‐correlation of cross‐hole experiment data (2015–2018). The inferred V S variations are up to ∼25% in the top 6 m and ∼10% at 2–5 m in depth. The V S variations correlate strongly with the water table depth changes, suggesting that the changes are mostly due to fluctuations of pore pressure in the shallow material. The shallow velocity changes alter the near‐surface conditions, can affect seismic hazard estimation, and may be improperly attributed to deeper processes without careful analysis.

58 GEOSCIENCES↗

Monitoring Preferential Flow of Water in Sand Using Thermoacoustics Wave Imaging

Abstract Accurate predictions of fluid flow, mass transport, and reaction rates critically impact the efficiency and reliability of subsurface exploration and sustainable use of subsurface resources. Quantitative dynamical sensing and imaging can play a pivotal role in the ability to make such predictions. Geophysical thermoacoustic technology has the potential to provide the aforementioned capabilities, since it builds upon the principle that electromagnetic and mechanical wave fields can be coupled through a thermodynamic process. In this letter, we present laboratory experiments featuring the efficacy of thermoacoustic imaging in the monitoring of preferential flow of water in porous media. Our laboratory experimental equipment can be readily packaged in a form factor that fits in a borehole, and the use of multiple acoustic transducers—which can be combined with volumetric coding techniques—has the potential to provide quasi‐real‐time imaging (0.5 Hz video rate) of regions in close proximity (a few meters) of an open field well.

Geology↗

Machine Learning‐Assisted Microearthquake Location Workflow for Monitoring the Newberry Enhanced Geothermal System

Abstract Enhanced geothermal systems (EGS) offer a sustainable energy source but face challenges in accurately locating microearthquakes induced during reservoir stimulation. Locating these microearthquakes provides reliable feedback on the stimulation progress. Current deep learning methods for locating earthquakes require extensive data sets for training, which is problematic as detected microearthquakes are often limited. To address the scarcity of training data, we propose a practical workflow using probabilistic multilayer perceptron (PMLP) which predicts microearthquake locations from cross‐correlation time lags in waveforms. Utilizing a 3D velocity model of Newberry site derived from ambient noise interferometry, we generate numerous synthetic microearthquakes and 3D acoustic waveforms for PMLP training. Accurate synthetic tests prompt us to apply the trained network to the 2012 and 2014 stimulation field waveforms. To enhance the accuracy of source localization, we carefully handpick the P‐arrival times. Predictions on the 2012 stimulation data set show major microseismic activity at depths of 0.5–1.2 km, correlating with a known casing leakage scenario. In the 2014 data set, the majority of predictions concentrate at 2.0–2.9 km depths, consistent with results obtained from conventional physics‐based inversion, and align with the presence of natural fractures from 2.0 to 2.7 km. We validate our findings by comparing the synthetic and field picks, demonstrating a satisfactory match for the first arrivals. By combining the benefits of quick inference speeds and accurate location predictions, we demonstrate the feasibility of using realistic synthetic data set to locate microseismicity for EGS monitoring.

15 GEOTHERMAL ENERGY↗

Nanobody-enabled monitoring of kappa opioid receptor states

Recent studies show that GPCRs rapidly interconvert between multiple states although our ability to interrogate, monitor and visualize them is limited by a relative lack of suitable tools. We previously reported two nanobodies (Nb39 and Nb6) that stabilize distinct ligand- and efficacy-delimited conformations of the kappa opioid receptor. Here, we demonstrate via X-ray crystallography a nanobody-targeted allosteric binding site by which Nb6 stabilizes a ligand-dependent inactive state. As Nb39 stabilizes an active-like state, we show how these two state-dependent nanobodies can provide real-time reporting of ligand stabilized states in cells in situ. Significantly, we demonstrate that chimeric GPCRs can be created with engineered nanobody binding sites to report ligand-stabilized states. Our results provide both insights regarding potential mechanisms for allosterically modulating KOR with nanobodies and a tool for reporting the real-time, in situ dynamic range of GPCR activity.

60 APPLIED LIFE SCIENCES↗

Flexible organic integrated electronics for self-powered multiplexed ocular monitoring

Smart contact lens has drawn extensive research interests due to the noninvasive real-time detection of the human body to provide biomedical information for health management. However, it has been difficult to accurately measure the physiological signals in tears, and the use of external power source has also hindered the future applications. Here, we demonstrated an organic electrochemical transistor based multiplexed sensors self-powered by the organic solar cells (OSCs). The integrated device was fabricated via simple process including solution blade-coating and thermal evaporation. OSCs were optimized to provide optimal operation voltage for the sensors that exhibit semilog-linear response to the glucose and calcium ions in tear fluids without any peripheral circuits. The sensing signals can be transmitted to the laptop wirelessly through a near filed communication unit. This integrated self-powered multiplexed sensing device will provide real-time monitoring of the biomarkers in tears, prospected to be installed on the smart contact lens for the early detection and diagnosis of diabetes.

36 MATERIALS SCIENCE↗

Manipulating polymer composition to create low-cost, high-fidelity sensors for indoor CO2 monitoring

Abstract Carbon dioxide (CO 2 ) has been linked to many deleterious health effects, and it has also been used as a proxy for building occupancy measurements. These applications have created a need for low-cost and low-power CO 2 sensors that can be seamlessly incorporated into existing buildings. We report a resonant mass sensor coated with a solution-processable polymer blend of poly(ethylene oxide) (PEO) and poly(ethyleneimine) (PEI) for the detection of CO 2 across multiple use conditions. Controlling the polymer blend composition and nanostructure enabled better transport of the analyte gas into the sensing layer, which allowed for significantly enhanced CO 2 sensing relative to the state of the art. Moreover, the hydrophilic nature of PEO resulted in water uptake, which provided for higher sensing sensitivity at elevated humidity conditions. Therefore, this key integration of materials and resonant sensor platform could be a potential solution in the future for CO 2 monitoring in smart infrastructure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time laser ultrasonic monitoring of laser-induced thermal processes

Abstract Intra- and inter-layer integrity of components fabricated with advanced manufacturing techniques, such as laser powder bed fusion, is dependent upon rapid heating, melting, and solidification processes. There is a need for new techniques to provide in situ feedback of these processes. Here a laser-based ultrasonic technique to probe thermal effects induced by a high-power continuous wave laser in titanium samples is described. Numerical simulations were performed to show that, for a spatially uniform heating beam, laser-induced surface acoustic waves are strongly influenced by surface heating conditions, are dispersive in the case of rapid heating, and that an abrupt velocity reduction happens upon the onset of surface melting. Furthermore, laser-based ultrasound experimental results which monitor the transient change of surface wave travel time associated with high power laser surface heating are provided. A pulsed laser is used to generate high frequency surface acoustic waves that propagate through the laser-heated region and are detected using a photorefractive crystal-based interferometer. Qualitative agreement is observed between theory and experiment with both showing a rapid reduction in the surface wave velocity at the onset of illumination and further decrease in surface wave velocity associated with melting. It is demonstrated that changes in the surface wave velocity can be used to track local heating and detect the onset of surface melting in real time.

36 MATERIALS SCIENCE↗

Current distribution monitoring enables quench and damage detection in superconducting fusion magnets

Abstract Fusion magnets made from high temperature superconducting ReBCO CORC ® cables are typically protected with quench detection systems that use voltage or temperature measurements to trigger current extraction processes. Although small coils with low inductances have been demonstrated, magnet protection remains a challenge and magnets are typically operated with little knowledge of the intrinsic performance parameters. We propose a protection framework based on current distribution monitoring in fusion cables with limited inter-cable current sharing. By employing inverse Biot-Savart techniques to distributed Hall probe arrays around CORC ® Cable-In-Conduit-Conductor (CICC) terminations, individual cable currents are recreated and used to extract the parameters of a predictive model. These parameters are shown to be of value for detecting conductor damage and defining safe magnet operating limits. The trained model is then used to predict cable current distributions in real-time, and departures between predictions and inverse Biot-Savart recreated current distributions are used to generate quench triggers. The methodology shows promise for quality control, operational planning and real-time quench detection in bundled CORC ® cables for compact fusion reactors.

47 OTHER INSTRUMENTATION↗

Momentum informed muon scattering tomography for monitoring spent nuclear fuels in dry storage cask

Development of an effective monitoring method for spent nuclear fuel (SNF) in a dry storage cask (DSC) is important to meet the increasing demand for dry storage investigations. The DSC investigation should provide information about the quantity of stored SNF, and quality assurance of materials should be possible without opening the cask. However, traditional nondestructive examination (NDE) methods such as x-rays are difficult to deploy for DSC investigation because a typical DSC is intentionally designed to shield against radiation. To address this challenge, cosmic ray muons (CRMs) are used as an alternative NDE radiation probe because they can easily penetrate an entire DSC system; however, a wide application of muons is often hindered due to the naturally low CRM flux (~10 4 muons/m 2 /min). This paper introduces a newly proposed imaging algorithm, momentum-informed muon scattering tomography (MMST) , and presents how a limitation of the current muon scattering tomography technique has been addressed by measuring muon momentum. To demonstrate its functionality, a commercial DSC with 24 pressurized light water reactor fuel assemblies (FAs) and the MMST system were designed in GEANT4. Three noticeable improvements were observed for MMST system as a DSC investigation tool: (1) a signal stabilization, (2) an enhanced capability to differentiate various materials, and (3) statistically increased precision to identify and locate missing FAs. The results show that MMST improves the investigation accuracy from 79 to 98% when one FA is missing and 51% to 88% when one-half FA is missing. The advancement of the NDE technique using CRM for DSC verification is expected to resolve long-standing problems in increasing demand for DSC inspections and nuclear security.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗