Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

LiH formation and its impact on Li batteries revealed by cryogenic electron microscopy

Little is known about how evolved hydrogen affects the cycling of Li batteries. Hypotheses include the formation of LiH in the solid-electrolyte interphase (SEI) and dendritic growth of LiH. Here, we discover that LiH formation in Li batteries likely follows a different pathway: Hydrogen evolved during cycling reacts to nucleate and grow LiH within already deposited Li metal, consuming active Li. We provide the evidence that LiH formed in Li batteries electrically isolates active Li from the current collector that degrades battery capacity. We detect the coexistence of Li metal and LiH also on graphite and silicon anodes, showing that LiH forms in most Li battery anode chemistries. Last, we find that LiH has its own SEI layer that is chemically and structurally distinct from the SEI on Li metal. Our results highlight the formation mechanism and chemical origins of LiH, providing critical insight into how to prevent its formation.

25 ENERGY STORAGE↗

Microscopy Parser

Reads proprietary electron microscope vendor files and exports them in a standardized open source HDF5 format.

Simpson, Joseph↗

Deep machine learning-assisted multiphoton microscopy to reduce light exposure and expedite imaging

Two-photon excitation fluorescence (2PEF) allows imaging of tissue up to about one millimeter in thickness. Typically, reducing fluorescence excitation exposure reduces the quality of the image. However, using deep learning super resolution techniques, these low-resolution images can be converted to high-resolution images. This work explores improving human tissue imaging by applying deep learning to maximize image quality while reducing fluorescence excitation exposure. We analyze two methods: a method based on U-Net, and a patch-based regression method. Both methods are evaluated on a skin dataset and an eye dataset. The eye dataset includes 1200 paired high power and low power images of retinal organoids. The skin dataset contains multiple frames of each sample of human skin. High-resolution images were formed by averaging 70 frames for each sample and low-resolution images were formed by averaging the first 7 and 15 frames for each sample. The skin dataset includes 550 images for each of the resolution levels. We track two measures of performance for the two methods: mean squared error (MSE) and structural similarity index measure (SSIM). For the eye dataset, the patches method achieves an average MSE of 27,611 compared to 146,855 for the U-Net method, and an average SSIM of 0.636 compared to 0.607 for the U-Net method. For the skin dataset, the patches method achieves an average MSE of 3.768 compared to 4.032 for the U-Net method, and an average SSIM of 0.824 compared to 0.783 for the U-Net method. Despite better performance on image quality, the patches method is worse than the U-Net method when comparing the speed of prediction, taking 303 seconds to predict one image compared to less than one second for the U-Net method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visualizing bleb mass dynamics in single cells using quantitative phase microscopy

Understanding biological responses to directed energy (DE) is critical to ensure the safety of personnel within the Department of Defense. At the Air Force Research Laboratory, we have developed or adapted advanced optical imaging systems that quantify biophysical responses to DE. One notable cellular response to DE exposure is the formation of blebs, or semi-spherical protrusions of the plasma membrane in living cells. In this work, we demonstrate the capacity of quantitative phase imaging (QPI) to both visualize and quantify the formation of membrane blebs following DE exposure. QPI is an interferometric imaging tool that uses optical path length as a label-free contrast mechanism and is sensitive to the non-aqueous mass density, or dry mass, of living cells. Blebs from both CHO-K1 and U937 cells were generated after exposure to a series of 600 ns, 21.2 kV/cm electric pulses. These blebs were visualized in real time, and their dry mass relative to the rest of the cell body was quantified as a function of time. It is our hope that this system will lead to an improved understanding of both DE-induced and apoptotic blebbing.

Steelman, Zachary A.↗

Computational microscopy for fast widefield deep-tissue fluorescence imaging using a commercial dual-cannula probe

A solid-glass cannula serves as a micro-endoscope that can deliver excitation light deep inside tissue while also collecting emitted fluorescence. Then, we utilize deep neural networks to reconstruct images from the collected intensity distributions. By using a commercially available dual-cannula probe, and training a separate deep neural network for each cannula, we effectively double the field of view compared to prior work. We demonstrated ex vivo imaging of fluorescent beads and brain slices and in vivo imaging from whole brains. We clearly resolved 4 µm beads, with FOV from each cannula of 0.2 mm (diameter), and produced images from a depth of ∼1.2 mm in the whole brain, currently limited primarily by the labeling. Since no scanning is required, fast widefield fluorescence imaging limited primarily by the brightness of the fluorophores, collection efficiency of our system, and the frame rate of the camera becomes possible.

42 ENGINEERING↗

In situ high-harmonic microscopy of a nanostructured solid

Nanostructured optical surfaces allow exquisite control over linear and nonlinear light interactions, where the surface actively creates new frequencies up to high-order harmonics of an intense infrared driving laser field. The function and performance of these surfaces depend sensitively on the distribution of the high-harmonic fields in and between the nanostructured elements, as the high-harmonic wavelength becomes comparable to the nanoscale features of the surface. Imaging the nonlinear response at the active surface with nanometer resolution would greatly benefit the optimization of the metasurface's function. Here we demonstrate an approach to lensless imaging of extreme ultraviolet high harmonics that resolves the amplitude and phase of nonlinear polarization at the active nanostructured surface of an MgO crystal. Imaging the near-field distribution of high harmonics is the gateway to optimized functional high-harmonic metasurfaces and the integration of high harmonics on a chip.

36 MATERIALS SCIENCE↗

Investigating the dielectric properties of barium titanate nanocomposites using transmission electron microscopy image processing

Abstract Barium titanate (BTO) is a ferroelectric perovskite material used in energy storage applications because of its high dielectric constant. A previous study showed that the dielectric constant for BTO nanoparticles drastically increases to over 15,000 at a particle size of 70 nm. This result is highly contested, but its implications to energy storage motivated our investigation into the dielectric constants of BTO nanoparticles that are incorporated into a polymer matrix. We developed a novel method of using image processing techniques on transmission electron microscope images of BTO-polymer nanocomposites. Data on the positions, shapes, sizes, and orientations of BTO nanoparticles were used to build more realistic computational models that simulate the dielectric behavior of the nanocomposites. Here, we investigate the relationship between regions of enhanced electric field and the composite dielectric constant.

36 MATERIALS SCIENCE↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Microstructural and chemical characterization of medium burnup fast reactor MOX using electron microscopy

A thorough post-irradiation examination campaign of medium burnup Sodium Fast Reactor (SFR) mixed oxide (MOX) fuel has been undertaken over the past two years to better understand the performance at intermediate burnup of this annular fuel design. Non-destructive examinations as well as destructive examinations of two pins have been recently published by the authors, providing data regarding the performance at macro-scale. The analyses of selected samples have continued to provide more details regarding the overall microstructure and, particularly, the fuel-cladding interaction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrafast Electron Microscopy for Spatial-Temporal Mapping of Charge Carriers

This LDRD supported efforts to significantly advance the scanning ultrafast electron microscope (SUEM) for spatial-temporal mapping of charge carrier dynamics in semiconductor materials and microelectronic devices. Sandia's SUEM capability in Livermore, CA, was built and demonstrated with previous LDRD funding; however, the stability and usability of the tool limited the throughput for analyzing samples. A new laser alignment strategy improved the stability of the SUEM, and the design and characterization of a new micro-channel plate (MCP)- based detector improved the signal-to-noise of the SUEM signal detection. These enhancements to the SUEM system improved throughput by over two orders of magnitude (before, a single time series of SUEM measurements would take several days to several weeks to acquire; now, the same measurements can be completed in~90 minutes in an automated fashion). The SUEM system can now be routinely used as an analytical instrument and will be a central part of several multi-year projects starting in FY22.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗