Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC MIRRORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

In-orbit performance of the ITOS improved attitude control system with Hall generator brushless motor and earth-splitting technique

The National Aeronautics and Space Administration (NASA), launched ITOS-D with an improved attitude control system. A Hall generator brushless dc torque motor replaced the brush dc torque motor on Tiros-M and ITOS-A. Two CO2 attitude horizon sensors and one mirror replaced the four wideband horizon sensors and two mirrors on ITOS-1 and NOAA-1. Redundant pitch-control electronic boxes containing additional electronic circuitry for earth-splitting and brushless motor electronics were used. A method of generating a spacecraft earth-facing side reference for comparison to the time occurrence of the earth-splitting pulse was used to automatically correct pitch-attitude error. A single rotating flywheel, supported by a single bearing, provided gyroscopic stability and the required momentum interchange to keep one side of the satellite facing the earth. Magnetic torquing against the earth's magnetic field eliminated the requirement for expendable propellants which would limit satellite life in orbit.

Peacock, W. M.↗

Large-volume centimeter-wave cavities for axion searches

The scan rate of an axion haloscope is proportional to the square of the cavity volume. In this paper, a new class of thin-shell cavities are proposed to search for axionic dark matter. These cavities feature active volume much larger (>20×) than that of a conventional cylindrical haloscope, comparable quality factor Q, and a similar frequency tuning range. Furthermore, full 3D numerical finite-element analyses have been used to show that the TM 010 eigenmodes are singly polarized throughout the volume of the cavity and can facilitate axion-photon conversion in uniform magnetic field produced by a superconducting solenoid. To mitigate spurious mode crowding and volume losses due to localization, a pre-amplification binary summing network will be used for coupling. Because of the favorable frequency-scaling, the new cavities are most suitable for centimeter-wavelength (~ 10–100 GHz), corresponding to the promising post-inflation axion production window. In this frequency range, the tight machining tolerances required for high-Q thin-shell cavities are achievable with standard machining techniques for near-infrared mirrors.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Small-Aperture Cos-theta Dipole Insert Coil Based on Bi2212 Rutherford Cable and Stress Management Structure

The U.S. Magnet Development Program (US-MDP) is developing high-field accelerator magnets with magnetic fields beyond the limits of Nb3Sn technology based on high temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212). However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are substantial in high-field accelerator magnets. To prevent large degradation of the Bi2212 coils and achieve the required field quality, an innovative design which provides turn positioning during coil fabrication and operation and manage azimuthal and radial strains/stresses in the coil has been proposed at FNAL. This paper describes the development of a small-aperture two-layer Bi2212 dipole coil with stress management. The main parameters of the Bi2212 wire and Rutherford cable, the design of coil stress management structure and its plastic model, the coil mechanical analysis in the dipole mirror configuration are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The oblique electron lens.

An oblique electron lens is described that is especially applicable to image converters and camera tubes employing flat opaque photocathodes. The use of optical lenses, corrector plates, and/or mirrors (often employed in other electron lenses designed for use with opaque photocathodes) are eliminated. The oblique electron lens is well suited to ultraviolet and vacuum ultraviolet image converters, and to image converters employing opaque negative electron affinity photocathodes. It is also possible to use this oblique electron lens for electronography. Measurements on an experimental tube show that a limiting resolution of 50 line pairs/mm is possible, but the intrinsic lens quality is believed to approach that of a conventional electromagnetic lens having uniform and colinear electric and magnetic fields.

Johnson, C. B.↗

GEMS

The prime scientific objectives of the Gravity and Extreme Magnetism SMEX, GEMS, are to determine the effects of the spin of black holes, the configurations of the magnetic fields of magnetars, and the structure of the supernova shocks which accelerate cosmic rays. In the cases of both stellar black holes and supermassive black holes, sensitivity to 1% polarization is needed to make diagnostic measurements of the net polarizations predicted for probable disk and corona models. GEMS can reach this goal for several Seyferts and quasars and measure the polarizations of representatives of a variety of other classes of X-ray sources, such as rotation-powered and accretion-powered pulsars. GEMS uses foil mirrors to maximize the collecting area achievable within the SMEX constraints. The polarimeters at the mirror foci are Time Projection Chambers which use the photoelectic effect to measure the polarization of the incident photon. We have built laboratory models with good efficiency and modulation in the 2-10 keV range. An attached small student experiment would add 0.5 keV sensitivity for bright soft sources. The instrument has a point spread function which allows measurement of structures in the brighter nearby supernova remnants. GEMS' Orbital Sciences spacecraft will rotate at a rate of 0.1 revolutions per minute during observations, so that systematic errors due to the detector can be detected and corrected. A program of 35 sources can be observed in 9 months. GEMS is designed for a two year lifetime which will allow a General Observer program that would more than double the number of sources measured. For subsets of black holes, neutron stars and supernova remnants, GEMS will measure the polarization of several sources, solving important questions while establishing the sensitivity required for future missions.

Swank, Jean↗

Expanded Performance Characterization of the NASA HERMeS Hall Thruster

This work presents a summary of a detailed performance assessment of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) thruster at the throttle conditions most relevant for the Gateway Power and Propulsion Element (PPE). First, an assessment was performed of TDU-3 performance and stability at the previously-tested throttle points of 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW that confirmed TDU-3 was operating nominally and consistent with historical baselines. TDU-3 performance and stability were then assessed throughout the PPE throttle range of 2.6-12 kW and shown to mirror the characteristics observed at the previously tested conditions. Finally, a statistical estimate for the thrust specification at the expanded set of throttle conditions was computed and found to yield similar tolerance ranges to those calculated for the heritage conditions. Taken together, these results provide strong evidence that the demonstrated performance characteristics of the HERMeS design are preserved at the expanded set of throttle conditions relevant to application on PPE.

HERMeS↗

Extended Performance Characterization of the NASA HERMeS Hall Thruster

This work presents a summary of a detailed performance assessment of the Hall Effect Rocket with Magnetic Shielding (HERMeS) Technology Demonstration Unit 3 (TDU-3) thruster at the throttle conditions most relevant for the Gateway Power and Propulsion Element (PPE). First, an assessment was performed of TDU-3 performance and stability at the previously-tested throttle points of 300 V/6.25 kW, 400 V/8.33 kW, 500 V/10.42 kW, and 600 V/12.5 kW that confirmed TDU-3 was operating nominally and consistent with historical baselines. TDU-3 performance and stability were then assessed throughout the PPE throttle range of 2.6-12 kW and shown to mirror the characteristics observed at the previously tested conditions. Finally, a statistical estimate for the thrust specification at the expanded set of throttle conditions was computed and found to yield similar tolerance ranges to those calculated for the heritage conditions. Taken together, these results provide strong evidence that the demonstrated performance characteristics of the HERMeS design are preserved at the expanded set of throttle conditions relevant to application on PPE.

HERMeS↗

The Princeton Field-Reversed Configuration for Compact Nuclear Fusion Power Plants

The Princeton Field-Reversed Configuration (PFRC) nuclear fusion reactor concept is an innovative approach to fusion power generation prioritizing low neutron production and small size. Here, a combination of analytical modeling and numerical simulation shows that the novel heating approach generates an FRC with closed field lines. Simulation data from a single-particle Hamiltonian code predicts ms-scale plasma heating in reactor-scale conditions while PIC codes predict formation of warm FRC plasmas from initial mirror fields. The PFRC-1 and PFRC-2 experiments have heated electrons to energies well in excess of 100 eV and plasma durations to 300 ms, more than 10 4 times longer than the predicted tilt instability growth time. From these data, we have created a development plan and anticipated performance metrics for a fusion reactor based on the PFRC concept. The resulting 1–10 MW PFRC reactors would be suitable for diverse applications, from submarines to urban environments to space propulsion. PFRC is a steady-state, driven magnetic confinement device. Plasma, inside a cylindrical array of coils, is confined and heated by external RF antennae. PFRC would be ultra-low radiation due to both its fuel and small size. The choice of advanced fuels, deuterium and helium-3 (D– 3 He), may be enabled by the high-β FRC configuration. The small size of the reactor would enable rapid exhaust of the dangerous tritium ash. Low radiation would make the reactor safer to operate and, in combination with simple geometry and small size, dramatically lowers development and maintenance costs. This review paper gives an introduction to the physics of the PFRC and a summary of the PFRC-2 experiment results to date. It then discusses the future program plan and how PFRC reactors would be commercialized.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Protein crystallography beamline BL2S1 at the Aichi synchrotron

The protein crystallography beamline BL2S1, constructed at one of the 5 T superconducting bending-magnet ports of the Aichi synchrotron, is available to users associated with academic and industrial organizations. The beamline is mainly intended for use in X-ray diffraction measurements of single-crystals of macromolecules such as proteins and nucleic acids. Diffraction measurements for crystals of other materials are also possible, such as inorganic and organic compounds. BL2S1 covers the energy range 7–17 keV (1.8–0.7 Å) with an asymmetric-cut curved single-crystal monochromator [Ge(111) or Ge(220)], and a platinum-coated Si mirror is used for vertical focusing and as a higher-order cutoff filter. The beamline is equipped with a single-axis goniometer, a CCD detector, and an open-flow cryogenic sample cooler. Lastly, high-pressure protein crystallography with a diamond anvil cell can also be performed using this beamline.

Watanabe, Nobuhisa↗

A semikinetic model for early stage plasmasphere refilling. II - Effects of wave-particle interactions

The paper treats the early stages of plasmasphere refilling along an initially depleted L = 4 magnetic flux tube through a semikinetic model, with special attention given to the effects of wave-particle interactions in which stochastic diffusion of ions in perpendicular velocity due to equatorially concentrated electromagnetic ion cyclotron waves plays a central role. Characteristic individual ion trajectories are examined, as well as the devolution of bulk parameters and ion distribution functions when equal 'polar wind' streams are injected at the northern and southern ionospheres. In the ion trajectories, relatively modest and realistic perpendicular electric field power levels are found to lead to decreased mirror latitudes, substantial acceleration, and equatorial entrainment of these ions. A substantial equatorial density depletion is also found, in agreement with the results of Olsen (1992).

Lin, J.↗

Further Development Of Aperture: A Precise Extremely Large Reflective Telescope Using Re-Configurable Elements: NASA Innovative Advanced Concepts (NIAC) - Phase II

One of the pressing needs for space ultraviolet-visible astronomy is a design to allow larger mirrors than the James Webb Space Telescope primary. The diameter of the rocket fairing limits the mirror diameter such that all future missions calling for mirrors up to 16 meters in diameter or larger will require a mirror that is deployed post-launch. In response to the deployment requirement, we address the issues of this concept called "A Precise Extremely Large Reflective Telescope Using Reconfigurable Elements (APERTURE) with both hardware experiments and software simulations... We designed and built several fixtures with O-rings to hold a membrane. We established a coating process to make a membrane that was coated on one side with Cr and the other side with Cr-Terfenol-D-NiCo. The Terfenol-D (T-D hereafter) is the MSM (Magnetic Smart Memory) we use. We bought and established a procedure for measuring a deformation over time and purchased a Shack Hartmann system from Imagine Optic (https://www.imagine-optic.com). The first substrate we used was DuPont (TM) Kapton® polyimide film. Due to material creep, we found the stability over a 48-hour period with a Kapton substrate was not as good as desired (greater than 1 micron). We then switched to CP1 Polyimide. We found the CP1 much more stable to creep, being stable from about 3 hours to 48 hours to within a measurement error to below approximately 0.1 micron. We produced a 13 micron maximum deviation on a 50-millimeter-diameter piece of CP1 (25 microns thick). The T-D coating was about 2 microns, and the other layers, about 10 nanometers. The magnetic field at the base was about 0.1 teslas. We can make the T-D film at least 5 times thicker and the magnetic field at least 5 times stronger, and hence make deformations as much as 25 times larger. We have a formed a collaboration produced at the NIAC (NASA Innovative Advanced Concepts) mid-term review with Dr. Ron Shiri of Goddard Space Flight Center (GSFC) to explore making controlled deviations on lambda/14-lambda/20 scales which are required to bring a surface to the diffraction limit. We carried out only preliminary work on Si using a Coordinate Measuring Machine (CMM), which produced deviations on the 1 micron level. We are still working on a program to bring to GSFC a flat enough (radius of curvature greater than 10 microns) -coated a Si piece with Cr, T-D, NiCo. Then we plan to carry out tests with an interferometer. Further, we formed a new collaboration with Prof. Rajan Vaidyanathan of the University of Central Florida to replace the CP1 with a shape memory alloy (SMA). With his collaboration, we acquired new Federal funding outside of NASA to explore the use of SMAs (we use NiTi). Our preliminary results indicate that we can produce deformations greater than 1 micron on approximately 100 microns thick. Furthermore we have shown that the NiTi can deploy to better than 1 micron of its set original and then trained shape.

Re-Configurable Elements↗

Chiral magnetic effect without chirality source in asymmetric Weyl semimetals

Here, we describe a new type of the Chiral Magnetic Effect (CME) that should occur inWeyl semimetals with an asymmetry in the dispersion relations of the left- and right-handed chiral Weyl fermions. In such materials, time-dependent pumping of electrons from a non-chiral external source can generate a non-vanishing chiral chemical potential. This is due to the different capacities of the left- and right-handed (LH and RH) chiral Weyl cones arising from the difference in the density of states in the LH and RH cones. The chiral chemical potential then generates, via the chiral anomaly, a current along the direction of an applied magnetic field even in the absence of an external electric field. The source of chirality imbalance in this new setup is thus due to the band structure of the system and the presence of (non-chiral) electron source, and not due to the parallel electric and magnetic fields. We illustrate the effect by an argument based on the effective field theory, and by the chiral kinetic theory calculation for a rotationally invariant Weyl semimetal with different Fermi velocities in the left and right chiral Weyl cones; we also consider the case of a Weyl semimetal with Weyl nodes at different energies. We argue that this effect is generically present in Weyl semimetals with different dispersion relations for LH and RH chiral Weyl cones, such as SrSi 2 recently predicted as a Weyl semimetal with broken inversion and mirror symmetries, as long as the chiral relaxation time is much longer than the transport scattering time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B{sub 4}C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L{sub 3} edge on a high-T{sub c} superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure of correlation tensors in homogeneous anisotropic turbulence

The theory of isotropic tensors, developed by Robertson (1940), Batchelor (1946), and Chandrasekhar (1951), is extended to cover the general case of turbulence with a pseudo-vector-preferred direction, without assuming mirror-reflection invariance. Attention is focused on two-point-correlation functions, and it is shown that the form of the decomposition into proper and pseudo-tensor contributions is restricted by the homogeneity requirement. The somewhat unexpected result that the vector- and pseudo-vector-preferred-direction cases yield different results is presented: A pseudo-vector-preferred direction allows the correlation matrix one more functional degree of freedom than does the proper vector case. An explicit form of the two-point-correlation tensor in the presence of a uniform mean magnetic field is presented which may be appropriate for use in analysis of magnetic fluctuations in plasma containment devices or the interplanetary medium. A procedure for determining the magnetic helicity from experimental data is presented.

Matthaeus, W. H.↗

Soft X-ray/extreme ultraviolet images of the solar atmosphere with normal incidence multilayer optics

High-resolution images of the sun in the soft-X-ray/XUV range have been obtained with normal-incidence multilayer coated optics (MCOs) during a sounding-rocket flight on October 23, 1987 from White Sands. MCOs were used in two Cassegrain telescopes, as off-axis primary mirrors, and as tertiary mirrors operating with a Wolter-Schwarzschild (WS) grazing-incidence mirror. The inherent energy-selective property of MCOs allowed distinct groups of emission lines to be isolated in the solar corona and the transition region. Images were recorded at 173 and 256 A with the Cassegrain telescopes, at 256 A with a Herschelian telescope, and at 44, 173, and 256 A with the WS hybrid telescope. In addition, soft-X-ray images in the 8-18-A bandpass were obtained at the prime focus of the WS optics. The images show many features of the solar corona and transition region, including magnetically confined loops of hot solar plasma, coronal plumes, polar coronal holes, supergranulation, and features associated with overlying cool prominences.

Lindblom, Joakim F.↗

Facile synthesis of the nitrogen-doped graphene quantum dots at low temperature for cellular labeling

Highlights: • The N-GQDs are prepared via a facile stirring method on a magnetic stirrer at low temperature. • The N-GQDs exhibit outstanding biocompatibility in the live HeLa cells for biological applications. • The live cells keep a 100% survival rate in the high N-GQDs concentration of 200 μg mL{sup −1} for 48 h. - Abstract: A facile one-step approach is developed for the large-scale synthesis of nitrogen doped graphene quantum dot (N-GQDs) at low temperature by using citric acid (CA) as the precursor. The emission wavelength of the N-GQDs is nearly excitation-dependent, which may mirror the effects from particles of different sizes and distribution of different emissive sites on nanoparticles. Moreover, the products are then tested with live Hela cells for the extraordinary biocompatibility. The cellular viability is remained to be 100% even after a 48 h exposure with the high N-GQDs concentration of 200 μg mL{sup −1} and this survival rate is really much higher than that have been reported previously. The as-prepared N-GQDs with negligible inherent toxicity exhibit excellent biological applications such as bio-imaging and cell tracking.

60 APPLIED LIFE SCIENCES↗

Quantum Phases of a Vortex String

We argue that the world sheet dynamics of magnetic k strings in the Higgs phase of the mass-deformed N=4 theory is controlled by a bosonic O(3) sigma model with anisotropy and a topological theta term. The theory interpolates between a massless O(2) symmetric regime, a massive O(3) symmetric phase, and another massive phase with a spontaneously broken Z{sub 2} symmetry. The first two phases are separated by a Kosterlitz-Thouless transition. When theta=pi, the O(3) symmetric phase flows to an interacting fixed point; sigma model kinks and their dyonic partners become degenerate, mirroring the behavior of monopoles in the parent gauge theory. This leads to the identification of the kinks with monopoles confined on the string.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗