Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

High-Resolution, Lightweight, and Low-cost X-Ray Optics for the Lynx Observatory

We describe an approach to build an x-ray mirror assembly that can meet Lynx’s requirements of high-angular resolution, large effective area, light weight, short production schedule, and low-production cost. Adopting a modular hierarchy, the assembly is composed of 37,492 mirror segments, each of which measures ∼100 mm × 100 mm × 0.5 mm. These segments are integrated into 611 modules, which are individually tested and qualified to meet both science performance and spaceflight environment requirements before they in turn are integrated into 12 metashells. The 12 metashells are then integrated to form the mirror assembly. This approach combines the latest precision polishing technology and the monocrystalline silicon material to fabricate the thin and lightweight mirror segments. Because of the use of commercially available equipment and material and because of its highly modular and hierarchical building-up process, this approach is highly amenable to automation and mass production to maximize production throughput and to minimize production schedule and cost. As of fall 2018, the basic elements of this approach, including substrate fabrication, coating, alignment, and bonding, have been validated by the successful building and testing of single-pair mirror modules. In the next few years, the many steps of the approach will be refined and perfected by repeatedly building and testing mirror modules containing progressively more mirror segments to fully meet science performance, spaceflight environments, as well as programmatic requirements of the Lynx mission and other proposed missions, such as AXIS.

Zhang, William W.↗

Moderate resolution spectroscopy for the Space Infrared Telescope Facility (SIRTF)

The conceptual design presented for a low-to-moderate resolution IR spectrometer is expected to allow the spectroscopic study of objects whose location ranges from within the solar system to distant galaxies, with far greater sensitivity than previously available for the study of faint objects. The low resolution mode will allow detailed continuum radiation studies to be conducted, while the moderate resolution mode will facilitate studies encompassing the IR spectral signatures of small outer solar system bodies and the nature of more luminous active galaxies and QSOs at greater distances. The five spectrometer modules share a common aperture, and all gratings share a single scan mechanism. All heat sources other than the detectors operate at 7 K and are separated from the 4 K cold station. Two-dimensional area detector arrays are used in the 2.5- to 120-micron bands to simultaneously monitor adjacent regions in extended objects and to measure the background near point sources.

Houck, J. R.↗

High resolution measurements of the low state of Cyg X-1

Cyg X-1 was observed on two occasions separated by a year by the same X-ray rocket payload. High resolution temporal and spectral data reveal that Cyg X-1 was essentially unchanged in these two observations a year apart, with bursts of millisecond duration observed in the earlier flight and also, observed in the second. Analysis of these bursts has failed to reveal any internal temporal structure, either luminous or spectral. The shot noise character of temporal fluctuations on timescales approximately 1 second can be explained by the presence of exponential pulses with a fraction of a second time constant and a rate near 8 sec/1. The possible connection of these pulses with the bursts is examined.

Rothschild, R. E.↗

Comparison of ISCCP and other cloud amounts

A new 8-year global cloud climatology has been produced by the International Satellite Cloud Climatology Project (ISCCP) that provides information every 3 h at 280-km spatial resolution covering the period from July 1983 through June 1991. If cloud detection errors and differences in area sampling are neglected, individual ISCCP cloud amounts agree with individual surface observations to within 15% rms with biases of only a few percent. When measurements of small-scale, broken clouds are isolated in the comparison, the rms differences between satellite and surface cloud amounts are about 25%, similar to the rms difference between ISCCP and Landsat determinations of cloud amount. For broken clouds, the average ISCCP cloud amounts are about 5% smaller than estimated by surface observers (difference between earth cover and sky cover), but about 5% larger than estimated from very high spatial resolution satellite observations (overestimate due to low spatial resolution offset by underestimate due to finite radiance thresholds). Detection errors caused by errors in the ISCCP clear-sky radiances or incorrect radiance threshold magnitudes, are the dominant source of error in monthly average cloud amounts. The ISCCP cloud amounts appear to be too low over land by about 10%, somewhat less in summer and somewhat more in winter, and about right (maybe slightly low) over oceans. In polar regions, ISCCP cloud amounts are probably too low by about 15%-25% in summer and 5%-10% in winter. Comparison of the ISCCP climatology to three other cloud climatologies shows excellent agreement in the geographic distribution and seasonal variation of cloud amounts; there is little agreement about day/night contrasts in cloud amount. Notable results from ISCCP are that the gobal annual mean cloud amount is about 63%, being about 23% higher over oceans than over land, that it varies by less than 1% rms from month to month, and that it has varied by about 4% on a time scale approximately equal to 2-4 years. The magnitude of interannual variations of local (280-km scale) monthly mean cloud amounts is about 7%-9%. Longitudinal contrasts in cloud amount are just as large as latitudinal contrasts. The largest seasonal variation of cloud amount occurs in the tropics, being larger in summer than in winter; the seasonal variation in the middle latitudes has the opposite phase. Polar regions may have little seasonable variability in cloud amount. The ISCCP results show slightly more nightime than daytime cloud amount over oceans and more daytime than nightime cloud amount over land.

Rossow, William B.↗

Aerosol‐Jet‐Printable Covalent Organic Framework Colloidal Inks and Temperature‐Sensitive Nanocomposite Films

Abstract With molecularly well‐defined and tailorable 2D structures, covalent organic frameworks (COFs) have emerged as leading material candidates for chemical sensing, storage, separation, and catalysis. In these contexts, the ability to directly and deterministically print COFs into arbitrary geometries will enable rapid optimization and deployment. However, previous attempts to print COFs have been restricted by low spatial resolution and/or post‐deposition polymerization that limits the range of compatible COFs. Here, these limitations are overcome with a pre‐synthesized, solution‐processable colloidal ink that enables aerosol jet printing of COFs with micron‐scale resolution. The ink formulation utilizes the low‐volatility solvent benzonitrile, which is critical to obtaining homogeneous printed COF film morphologies. This ink formulation is also compatible with other colloidal nanomaterials, thus facilitating the integration of COFs into printable nanocomposite films. As a proof‐of‐concept, boronate‐ester COFs are integrated with carbon nanotubes (CNTs) to form printable COF‐CNT nanocomposite films, in which the CNTs enhance charge transport and temperature sensing performance, ultimately resulting in high‐sensitivity temperature sensors that show electrical conductivity variation by 4 orders of magnitude between room temperature and 300 °C. Overall, this work establishes a flexible platform for COF additive manufacturing that will accelerate the incorporation of COFs into technologically significant applications.

2D materials↗

Constructing Synoptic Maps of Stratospheric Column Ozone from HALOE, SAGE and Balloonsonde Data Using Potential Vorticity Isentropic Coordinate Transformations

In this study we utilize potential vorticity - isentropic (PVI) coordinate transformations as a means of combining ozone data from different sources to construct daily, synthetic three-dimensional ozone fields. This methodology has been used successfully to reconstruct ozone maps in particular regions from aircraft data over the period of the aircraft campaign. We expand this method to create high-resolution daily global maps of profile ozone data, particularly in the lower stratosphere, where high-resolution ozone data are sparse. Ozone climatologies in PVI-space are constructed from satellite-based SAGE II and UARS/HALOE data, both of which-use solar occultation techniques to make high vertical resolution ozone profile measurements, but with low spatial resolution. A climatology from ground-based balloonsonde data is also created. The climatologies are used to establish the relationship between ozone and dynamical variability, which is defined by the potential vorticity (in the form of equivalent latitude) and potential temperature fields. Once a PVI climatology has been created from data taken by one or more instruments, high-resolution daily profile ozone field estimates are constructed based solely on the PVI fields, which are available on a daily basis from NCEP analysis. These profile ozone maps could be used for a variety of applications, including use in conjunction with total ozone maps to create a daily tropospheric ozone product, as input to forecast models, or as a tool for validating independent ozone measurements when correlative data are not available. This technique is limited to regions where the ozone is a long-term tracer and the flow is adiabatic. We evaluate the internal consistency of the technique by transforming the ozone back to physical space and comparing to the original profiles. Biases in the long-term average of the differences are used to identify regions where the technique is consistently introducing errors. Initial results show the technique is useful in the lower stratosphere at most latitudes throughout the year,and in the winter hemisphere in the middle stratosphere. The results are problematic in the summer hemisphere middle stratosphere due to increased ozone photochemistry and weak PV gradients. Alternate techniques in these regions will be discussed. An additional limitation is the quality and resolution of the meteorological data.

Hollandsworth, Stacey M.↗

UWB Tracking System Design for Free-Flyers

This paper discusses an ultra-wideband (UWB) tracking system design effort for Mini-AERCam (Autonomous Extra-vehicular Robotic Camera), a free-flying video camera system under development at NASA Johnson Space Center for aid in surveillance around the International Space Station (ISS). UWB technology is exploited to implement the tracking system due to its properties, such as high data rate, fine time resolution, and low power spectral density. A system design using commercially available UWB products is proposed. A tracking algorithm TDOA (Time Difference of Arrival) that operates cooperatively with the UWB system is developed in this research effort. Matlab simulations show that the tracking algorithm can achieve fine tracking resolution with low noise TDOA data. Lab experiments demonstrate the UWB tracking capability with fine resolution.

Ni, Jianjun↗

UWB Tracking System Design with TDOA Algorithm

This presentation discusses an ultra-wideband (UWB) tracking system design effort using a tracking algorithm TDOA (Time Difference of Arrival). UWB technology is exploited to implement the tracking system due to its properties, such as high data rate, fine time resolution, and low power spectral density. A system design using commercially available UWB products is proposed. A two-stage weighted least square method is chosen to solve the TDOA non-linear equations. Matlab simulations in both two-dimensional space and three-dimensional space show that the tracking algorithm can achieve fine tracking resolution with low noise TDOA data. The error analysis reveals various ways to improve the tracking resolution. Lab experiments demonstrate the UWBTDOA tracking capability with fine resolution. This research effort is motivated by a prototype development project Mini-AERCam (Autonomous Extra-vehicular Robotic Camera), a free-flying video camera system under development at NASA Johnson Space Center for aid in surveillance around the International Space Station (ISS).

Ni, Jianjun↗

Millimeter and Submillimeter Spectroscopy of Titan

Our major goals for the first year of this program were to develop a general improved radiative transfer model of the atmosphere of Titan, and to accurately determine the global abundance of CO from observations obtained using the Owens Valley Radio Observatory Millimeter Array. Other goals were to reanalyze older data sets using the improved radiative transfer model and to observe other molecular species as time permitted. Our program was granted two Titan transits to measure the CO(2-1) rotational transition at low spatial resolution, and one transit to measure nitriles and organics in the 236-239 GHz spectral range. In year two, our program was granted two Titan transits to measure the CO(2-1) rotational transition at low spatial resolution, and one transit to measure nitriles and organics in the 236-239 GHz spectral range. The CO(2-1) observations were previously reported in a published paper

Gurwell, Mark A.↗

A first look at AS-ROC: a Si-Ge integrated chip readout for fast timing

Abstract Advances in timing detector technology require new specialized readout electronics. Applications demand below 10 ps time of arrival resolution and low power for a low repetition rate. A possible path to achieve O(10 ps) time resolution is an integrated chip using Silicon Germanium (SiGe) technology. Using DoE SBIR funding, Anadyne, Inc., in collaboration with UC Santa Cruz, has developed a prototype SiGe front-end readout chip optimized for low power and timing resolution. Two versions of the chip were produced with performance in simulation: a more power version with 10 ps resolution at 5 fC with 1.1 mW/channel, and a less power version with 10 ps resolution at 8 fC with 0.6 mW/channel.The chip was produced at Tower Semiconductor with 350 nm technology. The ASIC from the prototype run shows good performance: a rise time of 0.7–1 ns and 25 mV per fC response with RMS noise <1 mV. Simulation and results from the prototype will be reported in this paper.

Instruments & Instrumentation↗

Approaching Angstrom-Scale Resolution in Lithography Using Low-Molecular-Mass Resists (<500 Da)

Resists that enable high-throughput and high-resolution patterning are essential in driving the semiconductor technology forward. The ultimate patterning performance of a resist in lithography is limited because of the trade-off between resolution, line-width roughness, and sensitivity; improving one or two of these parameters typically leads to a loss in the third. As the patterned feature sizes approach angstrom scale, the trade-off between these three metrics becomes increasingly hard to resolve and calls for a fundamental rethinking of the resist chemistry. Low-molecular-mass monodispersed metal-containing resists of high atom economy can provide not only very high resolution but also very low line-width roughness without sacrificing sensitivity. Here we describe a modular metal-containing resist platform (molecular mass <500 Da) where a molecular resist consists of just two components: a metal and a radical initiator bonded to it. This simple system not only is amenable to high-resolution electron beam lithography (EBL) and extreme ultraviolet lithography (EUVL) but also unites them mechanistically, giving a consolidated perspective of molecular and chemical processes happening during exposure. Irradiation of the resist leads to the production of secondary electrons that generate radicals in the initiator bonded to metal. This brings about an intramolecular rearrangement and causes solubility switch in the exposed resist. We demonstrate record 1.9–2.0 nm isolated patterns and 7 nm half-pitch dense line-space features over a large area using EBL. With EUVL, 12 nm half-pitch line-space features are shown at a dose of 68 mJ/cm 2 . In both of these patterning techniques, the line-width roughness was found to be ≤2 nm, a record low value for any resist platform, also leading to a low-performance trade-off metric, Z factor, of 0.6 × 10 –8 mJ·nm 3 . With the ultimate resolution limited by instrumental factors, potential patterning at the level of a unit cell can be envisaged, making low-molecular-mass resists best poised for angstrom-scale lithography.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-time resolution of the low-latitude asymmetric disturbance in the geomagnetic field.

The low-latitude asymmetric disturbance field is investigated by means of a Fourier harmonic analysis performed on 2.5-min interspaced values of magnetic records from eight stations, in lieu of the hourly values used in Crooker and Siscoe's (1971) study. The major advantage of the higher time resolution is that substorm activity, which has a time scale of 1-2 hr, can be studied in detail. Data covering four active periods in 1965 and five active periods in 1967 are used.

Crooker, N. U.↗

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence, and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify 𝛾 background from the cavern walls and from capture of 𝛼 particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further off-line analyses.

multi-purpose particle detectors↗

Plasma Facing Component Characterization and Correlation With Plasma Conditions in Lithium Tokamak Experiment-β

Lithium coatings in the Lithium Tokamak eXperiment (LTX) led to flat temperature profiles. The flat temperature profiles were observed along with a hot, low density edge, implying a broad, collisionless scrape-off layer (SOL). Additionally, in vacuo X-ray photoelectron spectroscopy (XPS) measurements established that lithium coatings evaporatively deposited onto high-Z plasma facing components (PFCs) became oxidized while retaining the ability to achieve good plasma performance long after lithium was applied to the PFCs. Longstanding theory predicted flat temperature profiles with low recycling walls, which was presumed to be due to hydrogen binding with elemental lithium to form lithium hydride. The presence of oxidized lithium, however, raised questions regarding the exact mechanism of hydrogen retention in LTX. To investigate these questions, the upgraded facility LTX- β includes a new sample exposure probe (SEP) for more detailed in vacuo analysis of PFC samples. The SEP is equipped with a vacuum suitcase capable of transporting samples representative of the LTX- β outer midplane PFCs to a stand-alone XPS system while maintaining pressures lower than the LTX- β base vacuum to limit the contamination between sample exposure and analysis. The low-energy resolution XPS system used in past experiments could only enable the determination of elemental percentages on the PFC sample surfaces. Because the new XPS system has higher energy resolution, it is more direct to assign chemical compounds to the measured binding energies. This capability has been confirmed by comparing XPS data from PFC test samples with measurements using a commercial high-resolution XPS system. Quartz crystal microbalances (QCMs) were used to quantify the thickness of the deposited lithium on the LTX- β PFCs. This article describes the application of the SEP to characterize the PFC surfaces using XPS and their relationship to plasma conditions.

Maan, Anurag↗

Exploring the Use of DSCOVR/EPIC Satellite Observations to Monitor Vegetation Phenology

Vegetation phenology plays a pivotal role in regulating several ecological processes and has profound impacts on global carbon exchange. Large-scale vegetation phenology monitoring mostly relies on Low-Earth-Orbit satellite observations with low temporal resolutions, leaving gaps in data that are important for monitoring seasonal vegetation phenology. High temporal resolution satellite observations have the potential to fill this gap by frequently collecting observations on a global scale, making it easier to study change over time. This study explored the potential of using the Earth Polychromatic Imaging Camera (EPIC) onboard the Deep Space Climate Observatory (DSCOVR) satellite, which captures images of the entire sunlit face of the Earth at a temporal resolution of once every 1–2 h, to observe vegetation phenology cycles in North America. We assessed the strengths and shortcomings of EPIC-based phenology information in comparison with the Moderate-resolution Imaging Spectroradiometer (MODIS), Enhanced Thematic Mapper (ETM+) onboard Landsat 7, and PhenoCam ground-based observations across six different plant functional types. Our results indicated that EPIC could capture and characterize seasonal changes of vegetation across different plant functional types and is particularly consistent in the estimated growing season length. Our results also provided new insights into the complementary features and benefits of the four datasets, which is valuable for improving our understanding of the complex response of vegetation to global climate variability and other disturbances and the impact of phenology changes on ecosystem productivity and global carbon exchange.

Weber, Maridee A.↗

High Speed and High Spatial Density Parameter Measurement Using Fiber Optic Sensing Technology

The present invention is an improved fiber optic sensing system (FOSS) having the ability to provide both high spatial resolution and high frequency strain measurements. The inventive hybrid FOSS fiber combines sensors from high acquisition speed and low spatial resolution Wavelength-Division Multiplexing (WDM) systems and from low acquisition speed and high spatial resolution Optical Frequency Domain Reflection (OFDR) systems. Two unique light sources utilizing different wavelengths are coupled with the hybrid FOSS fiber to generate reflected data from both the WDM sensors and OFDR sensors operating on a single fiber optic cable without incurring interference from one another. The two data sets are then de-multiplexed for analysis, optionally with conventionally-available WDM and OFDR system analyzers.

Parker, Allen R. Jr.↗

Astronomical X-Ray Optics Using Mono-Crystalline Silicon: High Resolution, Light Weight, and Low Cost

X-ray astronomy critically depends on X-ray optics. The capability of an X-ray telescope is largelydetermined by the point-spread function (PSF) and the photon-collection area of its mirrors, the same astelescopes in other wavelength bands. Since an X-ray telescope must be operated above the atmosphere inspace and that X-rays reflect only at grazing incidence, X-ray mirrors must be both lightweight and thin, bothof which add significant technical and engineering challenge to making an X-ray telescope. In this paper wereport our effort at NASA Goddard Space Flight Center (GSFC) of developing an approach to making an Xraymirror assembly that can be significantly better than the mirror assembly currently flying on the ChandraX-ray Observatory in each of the three aspects: PSF, effective area per unit mass, and production cost per uniteffective area. Our approach is based on the precision polishing of mono-crystalline silicon to fabricate thinand lightweight X-ray mirrors of the highest figure quality and micro-roughness, therefore, having thepotential of achieving diffraction-limited X-ray optics. When successfully developed, this approach will makeimplementable in the 2020s and 2030s many X-ray astronomical missions that are currently on the drawingboard, including sounding rocket flights such as OGRE, Explorer class missions such as STAR-X andFORCE, Probe class missions such as AXIS, TAP, and HEX-P, as well as large missions such as Lynx.

Zhang, William W.↗