Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Life Cycle Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Performance analysis of hybrid power configurations: Impact on primary energy intensity, carbon dioxide emissions, and life cycle costs

In this work, utilization of Natural gas and Hydrogen to support current and future building energy needs to offset the total electric demand while improving the grid resiliency and energy efficiency was investigated. Demand side energy management will play an important role in efficiently managing the available energy resources. Performance assessment of different power generation and energy management configurations is presented in this paper. Development of solutions in addressing grid resiliency by providing the ability to design suitable configurations for meeting individual building energy needs is discussed. Primary movers (PM) such as internal combustion engines (ICE) and fuel cells (FC) along with small scale auxiliary renewable energy source such as photovoltaics (PV) were considered. Key attributes of total carbon foot-print, life cycle costs including capital and operational expenditure, electric grid offset or peak shaving capability, thermal energy availability and its further potential to offset total electric demand, and primary energy intensity are analyzed and discussed in detail.

08 HYDROGEN↗

A model for selecting the best sustainable airport technology alternatives

Air transport is a continually expanding industry, a fact that has become even more evident with the recovery of the aviation industry post-COVID-19. This expansion amplified energy consumption at airports, which was already significantly high. Airport decision-makers are increasingly focusing on improving sustainability and addressing social, economic, and environmental criteria across airports worldwide. In this article, we propose a decision-making model for identifying a sustainable airport technology solution that minimizes the energy consumption of airport lighting while considering economic, emission, and life-cycle criteria. The proposed model combines data envelopment analysis and multi-criteria decision making techniques. We applied the model to the Dallas/Fort Worth International Airport (DFW) as a case study, considering eight lighting technology solutions, each with five luminous flux alternatives. Our model identified the best lighting technology solution for DFW outdoor and indoor environments based on the following criteria: luminous flux, capital costs, life-cycle costs, energy consumption, and emissions (CO2e, NOx, SO2, and PM2.5). The designed model is customizable to any airport and is applicable to a wide range of airport lighting technologies. In our analysis, Light-Emitting Diode lighting emerged as the most sustainable technology option. It ranked first in most cases due to its balance of high efficacy, long lifespan, low life-cycle cost, low capital cost, and lower emissions across all pollutants.

Tchivwila, Moise B↗

Large-Scale NASA Science Applications on the Columbia Supercluster

Columbia, NASA's newest 61 teraflops supercomputer that became operational late last year, is a highly integrated Altix cluster of 10,240 processors, and was named to honor the crew of the Space Shuttle lost in early 2003. Constructed in just four months, Columbia increased NASA's computing capability ten-fold, and revitalized the Agency's high-end computing efforts. Significant cutting-edge science and engineering simulations in the areas of space and Earth sciences, as well as aeronautics and space operations, are already occurring on this largest operational Linux supercomputer, demonstrating its capacity and capability to accelerate NASA's space exploration vision. The presentation will describe how an integrated environment consisting not only of next-generation systems, but also modeling and simulation, high-speed networking, parallel performance optimization, and advanced data analysis and visualization, is being used to reduce design cycle time, accelerate scientific discovery, conduct parametric analysis of multiple scenarios, and enhance safety during the life cycle of NASA missions. The talk will conclude by discussing how NAS partnered with various NASA centers, other government agencies, computer industry, and academia, to create a national resource in large-scale modeling and simulation.

Brooks, Walter↗

Role of High-End Computing in Meeting NASA's Science and Engineering Challenges

High-End Computing (HEC) has always played a major role in meeting the modeling and simulation needs of various NASA missions. With NASA's newest 62 teraflops Columbia supercomputer, HEC is having an even greater impact within the Agency and beyond. Significant cutting-edge science and engineering simulations in the areas of space exploration, Shuttle operations, Earth sciences, and aeronautics research, are already occurring on Columbia, demonstrating its ability to accelerate NASA s exploration vision. The talk will describe how the integrated supercomputing production environment is being used to reduce design cycle time, accelerate scientific discovery, conduct parametric analysis of multiple scenarios, and enhance safety during the life cycle of NASA missions.

Biswas, Rupak↗

Simulated Bladed MMC Disk LCF Validation

The goal of this program was to evaluate the low cycle fatigue behavior of an SCS-6/Ti-6Al-4V sub-component under bi-axial loading conditions at 316 C(600 F). A simulated bladed TMC disk was designed having thirty four blades representing the number that would be used in Allied Signal's JTAGG II impeller. The outer diameter of the bladed ring was 254 mm (10.0 inch) and the inner diameter 114.3 mm (4.50 inch). The outer and inner diameter of the composite zone was 177.8 mm (7.00 inch) and 127.O mm(5.00 inch) respectively. Stress analysis showed that the fatigue life of the bladed composite ring would be about 12000 cycles for the test conditions applied. A modal analysis was conducted which showed that the blades would have sufficient life margin from dynamic excitation. The arbor design was the same as that employed in the spin-to burst test of NAS3-27027. A systematic stress analysis of each part making up the arbor was undertaken to assure the design would meet the low cycle fatigue requirements of the program. The Textron Systems grooved foil-fiber process was chosen to make the SCS-6/Ti-6Al-4V core ring based on the success they had in contract NAS3-27027. Fiber buckling, however, was observed at several locations in the first ring made which rendered it unsuitable for spin testing. The fiber buckling was attributed to cracking of the graphite tooling during the consolidation process. On this basis a second ring was made but it too contained fiber buckling defects. Analysis by Textron indicated that the fiber buckling was most likely due to poor placement of the SCS-6 fiber in the etched grooves of the Ti-6Al-4V foil. This was also a contributor to the defects in the first ring. Since there was little indication of control in the process to manufacture a quality ring a third attempt at making a ring was not undertaken.

Merrick, H. F.↗

The design analysis of a rechargeable lithium cell for space applications

Ambient temperature rechargeable lithium batteries are needed by NASA for advanced space power applications for future missions. Specific energies of not less than 100 Wh/kg and long cycle life are critical performance goals. A design analysis of a 35 Ah Li-TiS2 cell was carried out using literature and experimental data to identify key design parameters governing specific energy. It is found that high specific energies are achievable in prismatic cells, especially with the use of advanced hardware materials. There is a serious need for a greatly expanded engineering database in order to enable more quantitative design analysis.

Subba Rao, S.↗

Unified field studies of the algae testbed public-private partnership as the benchmark for algae agronomics

National scale agronomic projections are an important input for assessing potential benefits of algae cultivation on the future of innovative agriculture. The Algae Testbed Public-Private Partnership was established with the goal of investigating open pond algae cultivation across different geographic, climatic, seasonal, and operational conditions while setting the benchmark for quality data collection, analysis, and dissemination. Identical algae cultivation systems and data analysis methodologies were established at testbed sites across the continental United States and Hawaii. Within this framework, the Unified Field Studies were designed for algae cultivation during all 4 seasons across the testbed network. With increasingly diverse algae research and development, and field deployment strategies, the challenges associated with data collection, quality, and dissemination increase dramatically. The dataset presented here is the complete, curated, climatic, cultivation, harvest, and biomass composition data for each season at each site. Furthermore, these data enable others to do in-depth cultivation, harvest, techno-economic, life cycle, resource, and predictive growth modelling analysis, as well as development of crop protection strategies throughout the algae cultivation industry.

09 BIOMASS FUELS↗

National Launch System comparative economic analysis

Results are presented from an analysis of economic benefits (or losses), in the form of the life cycle cost savings, resulting from the development of the National Launch System (NLS) family of launch vehicles. The analysis was carried out by comparing various NLS-based architectures with the current Shuttle/Titan IV fleet. The basic methodology behind this NLS analysis was to develop a set of annual payload requirements for the Space Station Freedom and LEO, to design launch vehicle architectures around these requirements, and to perform life-cycle cost analyses on all of the architectures. A SEI requirement was included. Launch failure costs were estimated and combined with the relative reliability assumptions to measure the effects of losses. Based on the analysis, a Shuttle/NLS architecture evolving into a pressurized-logistics-carrier/NLS architecture appears to offer the best long-term cost benefit.

Prince, A.↗

Quantifying uncertainty in LCA-modelling of waste management systems

Highlights: Black-Right-Pointing-Pointer Uncertainty in LCA-modelling of waste management is significant. Black-Right-Pointing-Pointer Model, scenario and parameter uncertainties contribute. Black-Right-Pointing-Pointer Sequential procedure for quantifying uncertainty is proposed. Black-Right-Pointing-Pointer Application of procedure is illustrated by a case-study. - Abstract: Uncertainty analysis in LCA studies has been subject to major progress over the last years. In the context of waste management, various methods have been implemented but a systematic method for uncertainty analysis of waste-LCA studies is lacking. The objective of this paper is (1) to present the sources of uncertainty specifically inherent to waste-LCA studies, (2) to select and apply several methods for uncertainty analysis and (3) to develop a general framework for quantitative uncertainty assessment of LCA of waste management systems. The suggested method is a sequence of four steps combining the selected methods: (Step 1) a sensitivity analysis evaluating the sensitivities of the results with respect to the input uncertainties, (Step 2) an uncertainty propagation providing appropriate tools for representing uncertainties and calculating the overall uncertainty of the model results, (Step 3) an uncertainty contribution analysis quantifying the contribution of each parameter uncertainty to the final uncertainty and (Step 4) as a new approach, a combined sensitivity analysis providing a visualisation of the shift in the ranking of different options due to variations of selected key parameters. This tiered approach optimises the resources available to LCA practitioners by only propagating the most influential uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward Greener and More Sustainable Manufacture of Bauxite-Derived Adsorbents for Water Defluoridation

The bauxite-derived adsorbent, activated alumina (AA), has a current annual global market of over 600 million USD, and of this, more than one-third of AA is used for defluoridation of fluoride-bearing water. The commonly used Bayer process for production of AA suffers from thermodynamic inefficiency, thereby raising costs, and also causes significant environmental damage. Here, we evaluate three other bauxite-derived adsorbents as alternatives to AA for water defluoridation: Mildly processed bauxite, thermally activated bauxite, and acid-treated thermally activated bauxite (ATAB). We first determine the energy intensity and resource efficiency of these three new adsorbents throughout their (future, anticipated) manufacturing processes and compare their defluoridation performance in the laboratory. Then, we quantify the carbon footprints of the three adsorbents via the product life-cycle approach, from their manufacturing to their applications in defluoridation. The results reveal that these three adsorbents exhibit less energy intensity and higher resource efficiency, thereby lowering their carbon footprints by 2-20×, relative to an equivalent amount of AA. We also estimate the operating costs of manufacturing and potential revenues from carbon offsets for each of the three adsorbents. Replacement of about 33 000 tonnes per year of AA currently used for wastewater treatment with equivalent ATAB could annually reduce annual manufacturing costs by 4.7 million USD and additionally generate 79 200 tonnes CO 2 offsets. Finally, this study supports decision-making on selecting a greener and more sustainable approach for wastewater defluoridation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Techno-economic analysis of DC power distribution in commercial buildings

Improvements in building end-use efficiency have significantly reduced the energy intensity of new buildings, but diminishing returns make it a challenge to build very-low energy buildings cost-effectively. A largely untapped efficiency strategy is to improve the efficiency of power distribution within buildings. Direct current (DC) distribution with modern power electronics has the potential to eliminate much of the power conversion loss in alternating current (AC) building distribution networks that include photovoltaics and DC end uses. Previous literature suggests up to 15% energy savings from DC power distribution in very energy efficient buildings with onsite generation and battery storage. This paper extends prior energy modeling of DC versus AC distribution in buildings, to consider the cost of implementing DC systems on a life-cycle basis. A techno-economic analysis framework based on commercially available products that evaluates the cost-effectiveness of DC systems is presented. The analysis is conducted for three commercial building types in two California climate zones and for various PV and battery storage capacities. Monte Carlo simulation is used to compute the payback period and lifecycle cost savings of DC versus AC distribution systems. A future-market scenario is also examined, which evaluates how future efficiency improvements in power converters and changes in electricity tariffs may affect cost savings. This analysis shows that DC systems can be cost-effective in all scenarios that include large capacities of battery storage and onsite solar, whereas for systems without storage, DC distribution is generally not cost-effective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Life Cost Based FMEA Manual: A Step by Step Guide to Carrying Out a Cost-based Failure Modes and Effects Analysis

Failure occurs when one or more of the intended functions of a product are no longer fulfilled to the customer's satisfaction. The most critical product failures are those that escape design reviews and in-house quality inspection and are found by the customer. The product may work for a while until its performance degrades to an unacceptable level or it may have not worked even before customer took possession of the product. The end results of failures which may lead to unsafe conditions or major losses of the main function are rated high in severity. Failure Modes and Effects Analysis (FMEA) is a tool widely used in the automotive, aerospace, and electronics industries to identify, prioritize, and eliminate known potential failures, problems, and errors from systems under design, before the product is released (Stamatis, 1997). Several industrial FMEA standards such as those published by the Society of Automotive Engineers, US Department of Defense, and the Automotive Industry Action Group employ the Risk Priority Number (RPN) to measure risk and severity of failures. The Risk Priority Number (RPN) is a product of 3 indices: Occurrence (O), Severity (S), and Detection (D). In a traditional FMEA process design engineers typically analyze the 'root cause' and 'end-effects' of potential failures in a sub-system or component and assign penalty points through the O, S, D values to each failure. The analysis is organized around categories called failure modes, which link the causes and effects of failures. A few actions are taken upon completing the FMEA worksheet. The RPN column generally will identify the high-risk areas. The idea of performing FMEA is to eliminate or reduce known and potential failures before they reach the customers. Thus, a plan of action must be in place for the next task. Not all failures can be resolved during the product development cycle, thus prioritization of actions must be made within the design group. One definition of detection difficulty (D) is how well the organization controls the development process. Another definition relates to the detectability of a particular failure in the product when it is in the hands of the customer. The former asks 'What is the chance of catching the problem before we give it to the customer'? The latter asks 'What is the chance of the customer catching the problem before the problem results in a catastrophic failure?' (Palady, 1995) These differing definitions confuse the FMEA users when one tries to determine detection difficulty. Are we trying to measure how easy it is to detect where a failure has occurred or when it has occurred? Or are we trying to measure how easy or difficult it is to prevent failures? Ordinal scale variables are used to rank-order industries such as, hotels, restaurants, and movies (Note that a 4 star hotel is not necessarily twice as good as a 2 star hotel). Ordinal values preserve rank in a group of items, but the distance between the values cannot be measured since a distance function does not exist. Thus, the product or sum of ordinal variables loses its rank since each parameter has different scales. The RPN is a product of 3 independent ordinal variables, it can indicate that some failure types are 'worse' than others, but give no quantitative indication of their relative effects. To resolve the ambiguity of measuring detection difficulty and the irrational logic of multiplying 3 ordinal indices, a new methodology was created to overcome these shortcomings, Life Cost-Based FMEA. Life Cost-Based FMEA measures failure/risk in terms of monetary cost. Cost is a universal parameter that can be easily related to severity by engineers and others. Thus, failure cost can be estimated using the following simplest form: Expected Failure Cost = {sup n}{Sigma}{sub i=1}p{sub i}c{sub i}, p: Probability of a particular failure occurring; c: Monetary cost associated with that particular failure; and n: Total number of failure scenarios. FMEA is most effective when there are inputs into it from all concerned disciplines of the product development team. However, FMEA is a long process and can become tedious and won't be effective if too many people participate. An ideal team should have 3 to 4 people from: design, manufacturing, and service departments if possible. Depending on how complex the system is, the entire process can take anywhere from one to four weeks working full time. Thus, it is important to agree to the time commitment before starting the analysis else, anxious managers might stop the procedure before it is completed.

97 MATHEMATICS AND COMPUTING↗

Infrastructure Ecology for Sustainable and Resilient Urban Infrastructure Design

The population growth coupled with increasing urbanization is predicted to exert a huge demand on the growth and retrofit of urban infrastructure, particularly in water and energy systems. The U.S. population is estimated to grow by 23% (UN, 2009) between 2005 and 2030. The corresponding increases in energy and water demand were predicted as 14% (EIA, 2009) and 20% (Elcock, 2008), respectively. The water-energy nexus needs to be better understood to satisfy the increased demand in a sustainable manner without conflicting with environmental and economic constraints. Overall, 4% of U.S. power generation is used for water distribution (80%) and treatment (20%). 3% of U.S. water consumption (100 billion gallons per day, or 100 BGD) and 40% of U.S. water withdrawal (340 BGD) are for thermoelectric power generation (Goldstein and Smith, 2002). The water demand for energy production is predicted to increase most significantly among the water consumption sectors by 2030. On the other hand, due to the dearth of conventional water sources, energy intensive technologies are increasingly in use to treat seawater and brackish groundwater for water supply. Thus comprehending the interrelation and interdependency between water and energy system is imperative to evaluate sustainable water and energy supply alternatives for cities. In addition to the water-energy nexus, decentralized or distributed concept is also beneficial for designing sustainable water and energy infrastructure as these alternatives require lesser distribution lines and space in a compact urban area. Especially, the distributed energy infrastructure is more suited to interconnect various large and small scale renewable energy producers which can be expected to mitigate greenhouse gas (GHG) emissions. In the case of decentralized water infrastructure, on-site wastewater treatment facility can provide multiple benefits. Firstly, it reduces the potable water demand by reusing the treated water for non-potable uses and secondly, it also reduces the wastewater load to central facility. In addition, lesser dependency on the distribution network contributes to increased reliability and resiliency of the infrastructure. The goal of this research is to develop a framework which seeks an optimal combination of decentralized water and energy alternatives and centralized infrastructures based on physical and socio-economic environments of a region. Centralized and decentralized options related to water, wastewater and stormwater and distributed energy alternatives including photovoltaic (PV) generators, fuel cells and microturbines are investigated. In the context of the water-energy nexus, water recovery from energy alternatives and energy recovery from water alternatives are reflected. Alternatives recapturing nutrients from wastewater are also considered to conserve depleting resources. The alternatives are evaluated in terms of their life-cycle environmental impact and economic performance using a hybrid life cycle assessment (LCA) tool and cost benefit analysis, respectively. Meeting the increasing demand of a test bed, an optimal combination of the alternatives is designed to minimize environmental and economic impacts including CO2 emissions, human health risk, natural resource use, and construction and operation cost. The framework determines the optimal combination depending on urban density, transmission or conveyance distance or network, geology, climate, etc. Therefore, it will be also able to evaluate infrastructure resiliency against physical and socio-economic challenges such as population growth, severe weather, energy and water shortage, economic crisis, and so on.

30 DIRECT ENERGY CONVERSION↗

Lifespan Impacts to Infrastructure, Renewable Energy Components and Energy Storage Components Related to Fluoropolymer Use

This report focuses on the use of fluoropolymers in infrastructure materials (building construction materials, transportation, and electrical transmission and distribution); renewable energy generation components (specifically wind and solar); and energy storage components (lithium-ion batteries and fuel cells) and product lifespan impacts if fluoropolymers were no longer available or allowed in commerce. Additionally, environmental considerations for fluoropolymer manufacture, use, and end-of-life disposal are discussed. This document is the second of two companion reports. The first report, Assessment of Fluoropolymer Production and Use With Analysis of Alternative Replacement Materials, contained an analysis of use of fluoropolymers and their potential replacement technologies in aerospace, automotive, battery, building construction, chemical processing, electronics, infrastructure, semiconductor, solar panel, and wind energy industries sectors, along with qualitative life cycle assessment (LCA) and cost-benefit analysis of replacing fluoropolymers. This report does not focus on the lifecycle aspects of use of fluoropolymer or alternatives in the designated applications. For more information on those topics, see aforementioned report.

25 ENERGY STORAGE↗

dCache: The Storage System of Choice for Data-Intensive Applications

The ever-increasing volumes of data produced by modern scientific facilities like EuXFEL and LHC put significant stress on data management infrastructure operated by laboratories and research centers. The challenges to be addressed span the entire data life cycle, from ingest and efficient data analysis to long-term preservation, typically involving large tape libraries. dCache, a storage system developed in collaboration between the Deutsches Elektronen-Synchrotron (DESY), Fermi National Accelerator Laboratory, and Nordic e-Infrastructure Collaboration (NeIC), is designed to manage a large number of disk servers and to facilitate transparent data migration to and from archival storage. Its multifaceted approach offers a unified method to support a variety of scientific use cases with the same storage infrastructure, including high-throughput data ingest, data sharing over wide area networks, efficient access from HPC clusters, and long-term data preservation on tertiary storage. Initially developed for high energy physics (HEP) experiments, dCache is now used by various scientific communities, including astrophysics, biomedical research, and life sciences, each having specific requirements. This paper presents architecture, deployment strategies, performance and scalability enhancements, and recent advancements in dCache addressing the needs of scientific communities. Finally, we touch on the development and release process, ensuring the software’s high quality.

DCache↗

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers

The U.S. Department of Energy (DOE) recently completed a rulemaking process in which it amended the existing energy efficiency standards for residential water heaters. A key factor in DOE?s consideration of new standards is the economic impacts on consumers. Determining such impacts requires a comparison of the additional first cost of energy efficiency design options with the savings in operating costs. This paper describes the method used to conduct the life-cycle cost (LCC) and payback period analysis for gas and electric storage water heaters. It presents the estimated change in LCC associated with more energy-efficient equipment, including heat pump electric water heaters and condensing gas water heaters, for a representative sample of U.S. homes. The study included a detailed accounting of installation costs for the considered design options, with a focus on approaches for accommodating the larger dimensions of more efficient water heaters. For heat pump water heaters, the study also considered airflow requirements, venting issues, and the impact of these products on the indoor environment. The results indicate that efficiency improvement relative to the baseline design reduces the LCC in the majority of homes for both gas and electric storage water heaters, and heat pump electric water heaters and condensing gas water heaters provide a lower LCC for homes with large rated volume water heaters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗