Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laboratory procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

Versatile Remediation Module Final Operational Testing Results

Oak Ridge National Laboratory (ORNL) successfully demonstrated the Versatile Remediation Module (VRM), a prototype module designed and built by ORNL for performing the on-site remote repair of welded stainless-steel storage containers for spent nuclear fuel and high-level radioactive waste. This report describes the VRM prototype and its design features, components, qualification tests, operational procedures, and demonstration results to support continued long-term storage or off-site transportation of spent nuclear fuel and high-level radioactive waste currently stored in storage containers. A remote (i.e., 100 ft away from the simulated radiative environment) demonstration of the VRM was successfully performed on a full-scale mock-up welded stainless-steel canister. The VRM is designed with features to accommodate remediation techniques beyond those currently selected and described in this report. Therefore, many of the VRM’s features could benefit other remote nuclear or nonnuclear applications. The VRM is envisioned to serve as a development center to facilitate and enhance the further development of new remediation technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Apex Alpha with LabWare-LIMS Data Reduction for Alpha Analyses

Savannah River Site's Environmental Bioassay Laboratory is migrating its laboratory information management system (LIMS) from SQL-LIMS to Oracle Labware-LIMS (LW-LIMS) systems to align with the Department of Energy's cyber security policies. Concurrently with the LIMS upgrade, the current VMS based Alpha Measurement System (AMS) software is being replaced with Apex Alpha software to reduce other cyber vulnerabilities, streamline procedural production aspects of data handling, and improve outdated reduction processes to align the program with requirements outlined in ANSI N13.30. The primary technical changes which are being implemented are: - Reagent contributions are added in data reduction, - Moving average background equivalent activity are used for gross signal corrections, - Measured uncertainty of both are included in the decision level and propagated uncertainty, - Tracer levels are increased for precision and accuracy improvements, and - Reports are modified for compliance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Definition study for an extended manned test of a regenerative life support system

A program was defined which consists of extended ground-based manned tests of regenerative life support systems. The tests are to evaluate prototypes of advanced life support systems under operational, integrated conditions, thus providing data for the design of efficient environmental control and life support systems for use in long-duration space missions. The requirements are defined for test operations to provide a simulation of an orbiting space laboratory. The features of Phase A and B programs are described. These tests use proven backup equipment to ensure successful evaluation of the advanced subsystems. A pre-tests all-systems checkout period is provided to minimize equipment problems during extended testing and to familiarize all crew and operating staff members with test equipment and procedures.

Source record↗

Ballastic signature identification systems study

The results are described of an attempt to establish a uniform procedure for documenting (recording) expended bullet signatures as effortlessly as possible and to build a comprehensive library of these signatures in a form that will permit the automated comparison of a new suspect bullet with the prestored library. The ultimate objective is to achieve a standardized format that will permit nationwide interaction between police departments, crime laboratories, and other interested law enforcement agencies.

Reich, A.↗

Performance testing of the Galileo attitude control system

Performance testing plans, procedures, and initial results for the Galileo Attitude and Articulation Control Subsystem are described. The objectives of performance testing include test bed comparisons, examining the interactions between spacecraft dynamics and controllers, and verifying the ability to tune control algorithms in flight to meet specific performance requirements. Two primary test beds are described. One, the Integration Test Laboratory, drives actual flight hardware components and support equipment with a real time computer simulation of spacecraft dynamics. The other, the Functional Simulator, is a nonreal time computer simulation with high fidelity spacecraft dynamics, including flexible appendages, fuel slosh, and simulated hardware components. Initial Functional Simulator results are presented which illustrate spacecraft response to open loop spin-up and turn commands. A closed loop sun acquisition turn is also demonstrated. Future tests for verifying performance of attitude determination, spacecraft control, and scan platform pointing functions are outlined.

Bell, C. E.↗

Concentrator hot-spot testing, phase 1

Results of a study to determine the hot-spot susceptibility of concentrator cells, to provide a hot-spot qualification test for concentrator modules, and to provide guidelines for reducing hot-spot susceptibility are presented. Hot-spot heating occurs in a photovoltaic module when the short-circuit current of a cell is lower than the string operating current forcing the cell into reverse bias with a concurrent power dissipation. Although the basis for the concentrator module hot-spot qualification test is the test developed for flat-plate modules, issues, such as providing cell illumination, introduce additional complexities into the testing procedure. The same general guidelines apply for protecting concentrator modules from hot-spot stressing as apply to flat-plate modules. Therefore, recommendations are made on the number of bypass diodes required per given number of series cells per module or source circuit. In addition, a new method for determining the cell temperature in the laboratory or in the field is discussed.

Gonzalez, C. C.↗

EP/TOMS Science Data Processing Programmer's Guide. Version 1.9

This EP/TOMS Programmer's Guide provides detailed information concerning the data, software, operations, and maintenance of the EP/TOMS Science Data Processing System. This system was developed for the NASA Goddard Space Flight Center (GSFC), Laboratory for Atmospheres, Atmospheric Chemistry Branch (Code 916) by SSAI. The description of the EP/TOMS Science Data Processing System starts with an overall system perspective (Section 3). A description of all data files ingested, stored, and/or produced follows in Section 4. Detailed descriptions of each major software subsystem are in Section 5. Section 6 presents processing procedures. Section 7 presents maintenance procedures. Procedures for updating this document are included in Section 7.

Source record↗

Reducing systematic bias in machine learning applications to J/ψ signal extraction in high-energy nuclear physics

Machine learning techniques are increasingly used in high-energy nuclear physics because they can exploit multivariate correlations more efficiently than conventional cut-based analyses. A central challenge is the construction of training samples that faithfully reproduce the detector response observed in data. Signal samples are usually derived from detector simulations; therefore, mismatches between simulation and data can degrade classifier performance and introduce systematic biases. This work presents two practical correction procedures, namely cumulative distribution function (CDF) mapping and a shift-and-scale transformation, to align simulated signal features with those measured in data. Their performance is demonstrated with $J$/$\psi$ yield measurements in $\sqrt{s_{nn}}$ = 200 GeV Ru+Ru and Zr+Zr collisions recorded by STAR. A set of self-consistency tests shows that these procedures substantially suppress the systematic bias associated with data-simulation discrepancies in machine-learning-based signal extraction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Adaptive continuity-preserving simplification of street networks

Street network data is widely used to study human-based activities and urban structure. Often, these data are geared towards transportation applications, which require highly granular, directed graphs that capture the complex relationships of potential traffic patterns. While this level of network detail is critical for certain fine-grained mobility models, it represents a hindrance for studies concerned with the morphology of the street network. For the latter case, street network simplification — the process of converting a highly granular input network into its most simple morphological form — is a necessary, but highly tedious preprocessing step, especially when conducted manually. In this manuscript, we develop and present a novel adaptive algorithm for simplifying street networks that is both fully automated and able to mimic results obtained through a manual simplification routine. The algorithm — available in the neatnet Python package — outperforms current state-of-the-art procedures when comparing those methods to manually, human-simplified data, while preserving network continuity.

Python↗

Progression to Compatibility Evaluations in Flowing Molten Salts

Molten salt compatibility with structural alloys has been identified as a key issue for the development of Generation 3 concentrating solar power (CSP) systems with thermal storage. To accelerate this evaluation to pumped systems, the goal of this project was to conduct thermal convection loop (TCL) experiments with a peak temperature of ≥700°C and a typical temperature gradient of ~100°C. The experiments indicated that conventional ~16wt.%Cr Ni-based alloys are compatible up to 700°C with purified (i.e. low O) or dried (low H₂O) industrial-sourced Mg-K-Na chloride salt with <10 μm/yr loss. This two-year project was conducted based on the experimental and mechanistic understanding developed more than 60 years ago at Oak Ridge National Laboratory (ORNL). The first TCL experiment met the <15 μm/yr corrosion metric for this project with specimens of Ni-based alloy 600 exposed at 580°-700°C for 1000 h and post-exposure room temperature tensile tests showed minimal degradation. The second TCL experiment successfully deployed an electrochemical sensor from Argonne National Laboratory and had a peak temperature of 750°C but only ran for ~110 h due to a furnace failure. Both experiments used highly purified industrial-sourced salt with an O content of ~3 μg O/g salt and a Mg addition of 0.04 wt.%. In the second year, the Chloride Collective developed a more economical drying procedure such that the O content was much higher (>20,000 μg O/g salt). A third TCL experiment was conducted with a sensor and a peak temperature of 700°C using dried salt from the same industrial source and increased NaCl content (~20 wt.%). In addition to a 0.05% Mg addition to the salt, a Mg coupon was added in the coldest part of the loop which dissolved during the experiment. Again, small mass changes were noted for specimens of alloys 600 and C276 but the values were slightly higher than those measured in purified salt with Mg. A thin non-continuous and non-adherent oxide layer was deposited on most specimens containing Mg, Si and Al but Cr depletion also was observed. Both years included facilities qualification crucible experiments and then capsule experiments to confirm a baseline isothermal reaction rate. The first year capsule experiment led to the conclusion that the two-stage ORNL purification process using NH₄Cl and CCl₄ left the salt with a high Cl potential and a Mg addition (~0.05wt.%) was needed to lower the potential. The second year capsule experiments at 600° and 700°C found little difference in depth of attack for 0-0.25%Mg additions. In general, the complex reactions where salt can be trapped in the porous surface layer of metal indicated that mass change is an unreliable metric and average depth of Cr depletion is a better metric for assessing the extent of attack. These results have created a new baseline that is contrary to the recent published literature for chloride salts where mass losses have been reported that can be extrapolated to very significant annual metal loss rates. Chloride salt corrosion can be controlled and the results also indicate that salt purification to low O levels may not be necessary. However, additional TCL experiments are needed at different times and temperatures to generate important engineering information such as temperature dependent corrosion rates and reaction rate laws for extrapolation to long-term behavior and isolate the effect of salt additives and impurities.

36 MATERIALS SCIENCE↗

ANSI/ASHRAE/IES Standard 90.1-2022 Performance Rating Method Reference Manual

This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2022 (Standard 90.1-2022). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 was a new feature of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The procedures and processes described in the PRM reference manual (PRM-RM) are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot-spot qualification testing of concentrator modules

Results of a study to determine the hot-spot susceptibility of concentrator cells, to provide a hot-spot qualification test for concentrator modules, and to provide guidelines for reducing hot-spot susceptibility are presented. Hot-spot heating occurs in a photovoltaic module when the short-circuit current of a cell is lower than the string operating current, forcing the cell into reverse bias with a concurrent power dissipation. Although the basis for the concentrator-module hot-spot qualification test is the test developed for flat-plate modules, issues such as providing cell illumination introduce additional complexities into the testing procedure. The results indicate that the same general guidelines apply to protecting concentrator modules from hot-spot stressing as apply to flat-plate modules, and recommendations are made on the number of bypass diodes required per given number of series cells per module or source circuit. A method for determining the cell temperature in the laboratory or in the field is discussed.

Gonzalez, C. C.↗

Engineering Strategies for the Design of Plant Nutrient Delivery Systems for Use in Space: Approaches to Countering Microbiological Contamination

Microbiological contamination of crops within space-based crop growth research chambers has been postulated as a potentially significant problem. Microbial infestations; fouling of Nutrient Delivery System (NDS) fluid loops; and the formation of biofilms, have been suggested as the most obvious and important manifestations of the problem. Strict sanitation and quarantine procedures will reduce, but not eliminate, microbial species introduced into plant growing systems in space habitats. Microorganisms transported into space will most likely occur as contaminants on spacecraft components, equipment, the crew, and plant-propagative materials. Illustrations of the potential magnitude of the microbiological contamination issue will be drawn from the literature and from documentation of laboratory and commercial field experience. Engineering strategies for limiting contamination and for the development of countermeasures will be described. Microbiological control technologies and NDS hardware will be discussed. Configurations appropriate for microgravity research facilities, as well as anticipated bio-regenerative life support system implementations, will be explored. An efficiently designed NDS, capable of adequately meeting the environmental needs of crop plants in space, is considered to be critical in both the research and operational domains. Recommended experiments, tests and technology developments, structured to allow the development of prudent engineering solutions, will also be presented.

Gonzales, A. A.↗

Air Sampling Filter

General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

Source record↗

Software to Manage the Unmanageable

In 1995, NASA s Jet Propulsion Laboratory (JPL) contracted Redmond, Washington-based Lucidoc Corporation, to design a technology infrastructure to automate the intersection between policy management and operations management with advanced software that automates document workflow, document status, and uniformity of document layout. JPL had very specific parameters for the software. It expected to store and catalog over 8,000 technical and procedural documents integrated with hundreds of processes. The project ended in 2000, but NASA still uses the resulting highly secure document management system, and Lucidoc has managed to help other organizations, large and small, with integrating document flow and operations management to ensure a compliance-ready culture.

Source record↗

Quality Control and Calibration of the Dual-Polarization Radar at Kwajalein, RMI

Weather radars, recording information about precipitation around the globe, will soon be significantly upgraded. Most of today s weather radars transmit and receive microwave energy with horizontal orientation only, but upgraded systems have the capability to send and receive both horizontally and vertically oriented waves. These enhanced "dual-polarimetric" (DP) radars peer into precipitation and provide information on the size, shape, phase (liquid / frozen), and concentration of the falling particles (termed hydrometeors). This information is valuable for improved rain rate estimates, and for providing data on the release and absorption of heat in the atmosphere from condensation and evaporation (phase changes). The heating profiles in the atmosphere influence global circulation, and are a vital component in studies of Earth s changing climate. However, to provide the most accurate interpretation of radar data, the radar must be properly calibrated and data must be quality controlled (cleaned) to remove non-precipitation artifacts; both of which are challenging tasks for today s weather radar. The DP capability maximizes performance of these procedures using properties of the observed precipitation. In a notable paper published in 2005, scientists from the Cooperative Institute for Mesoscale Meteorological Studies (CIMMS) at the University of Oklahoma developed a method to calibrate radars using statistically averaged DP measurements within light rain. An additional publication by one of the same scientists at the National Severe Storms Laboratory (NSSL) in Norman, Oklahoma introduced several techniques to perform quality control of radar data using DP measurements. Following their lead, the Topical Rainfall Measuring Mission (TRMM) Satellite Validation Office at NASA s Goddard Space Flight Center has fine-tuned these methods for specific application to the weather radar at Kwajalein Island in the Republic of the Marshall Islands, approximately 2100 miles southwest of Hawaii and 1400 miles east of Guam in the tropical North Pacific Ocean. This tropical oceanic location is important because the majority of rain, and therefore the majority of atmospheric heating, occurs in the tropics where limited ground-based radar data are available.

Marks, David A.↗

Measurement Assurance for End-Item Users

The goal of a Quality Management System (QMS) as specified in ISO 9001 and AS9100 is to assure the end product meets specifications and customer requirements. Measuring devices, often called measuring and test equipments (MTE), provide the evidence of product conformity to the prescribed requirements. Therefore the processes which employ MTE can become a weak link to the overall QMS if proper attention is not given to development and execution of these processes. Traditionally, calibration of MTE is given more focus in industry standards and process control efforts than the equally important proper usage of the same equipment. It is a common complaint of calibration laboratory personnel that MTE users are only interested in "a sticker." If the QMS requires the MTE "to demonstrate conformity of the product," then the quality of the measurement process must be adequate for the task. This leads to an ad hoc definition; measurement assurance is a discipline that assures that all processes, activities, environments, standards, and procedures involved in making a measurement produce a result that can be rigorously evaluated for validity and accuracy. To evaluate that the existing measurement processes are providing an adequate level of quality to support the decisions based upon this measurement data, an understanding of measurement assurance basics is essential. This topic is complimentary to the calibration standard, ANSI/NCSL Z540.3-2006, which targets the calibration of MTE at the organizational level. This paper will discuss general measurement assurance when MTE is used to provide evidence of product conformity, therefore the target audience of this paper is end item users of MTE. A central focus of the paper will be the verification of tolerances and the associated risks, so calibration professionals may find the paper useful in communication with their customers, MTE users.

Mimbs, Scott M.↗