Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

The LSU-Argonne conversion electron spectrometer: A new detector for the X-Array and SATURN decay station

In this study, a new conversion electron detector has been commissioned at the ATLAS/ CARIBU facility at Argonne National Laboratory. The LSU-Argonne Conversion Electron Spectrometer (LACES) is a LN 2 -cooled Si(Li) detector system designed to be incorporated into a decay station that comprises the dedicated HPGe clover array with a box geometry (X -Array) and the Scintillator and Tape Using Radioactive Nuclei (SATURN) device. This integration enables simultaneous measurements of conversion electrons and gamma-rays in decay experiments, yielding novel information on transition multipolarities, electric monopole transitions, and isomeric states that decay mostly via conversion electrons. A measurement of the energy resolution of LACES yielded 2.3-keV FWHM at 975 keV for electrons and 1.3-keV FWHM at 75 keV for X-rays. A detailed study of the absolute detection efficiency (at 5 mm from the source) was performed, where this quantity was determined experimentally in the range of electron transition energies between 25.5 keV and 1047.8 keV and subsequently simulated using the GEANT4 code. Measurement and simulations are found to be in excellent agreement. A precise characterization, for this type of detector system, of the absolute detection efficiency for such a wide energy range is reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the reconstruction and identification of high-momentum muons in proton-proton collisions at $\sqrt{s} =$ 13 TeV

The CMS detector at the LHC has recorded events from proton-proton collisions, with muon momenta reaching up to 1.8 TeV in the collected dimuon samples. These high-momentum muons allow direct access to new regimes in physics beyond the standard model. Because the physics and reconstruction of these muons are different from those of their lower-momentum counterparts, this paper presents for the first time dedicated studies of efficiencies, momentum assignment, resolution, scale, and showering of very high momentum muons produced at the LHC. These studies are performed using the 2016 and 2017 data sets of proton-proton collisions at &surd;s = 13 TeV with integrated luminosities of 36.3 and 42.1 fb−1, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Limits on Millicharged Particles Using the ArgoNeuT Experiment at Fermilab

A search for millicharged particles, a simple extension of the standard model, has been performed with the ArgoNeuT detector exposed to the Neutrinos at the Main Injector beam at Fermilab. The ArgoNeuT liquid argon time projection chamber detector enables a search for millicharged particles through the detection of visible electron recoils. We search for an event signature with two soft hits (MeV-scale energy depositions) aligned with the upstream target. For an exposure of the detector of 1.0×10 20 protons on target, one candidate event has been observed, compatible with the expected background. This search is sensitive to millicharged particles with charges between 10 -3 $e$ and 10 -1 $e$ and with masses in the range from 0.1 to 3 GeV. This measurement provides leading constraints on millicharged particles in this large unexplored parameter space region.

43 PARTICLE ACCELERATORS↗

Time Resolution Characterization of 4H-SiC LGADs with a 90 Sr Source

This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a 90Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61 ps was achieved, comparable to that of standard Si LGADs. The present limitation in the time resolution of 4H-SiC LGADs appears to stem from limited charge generation. Nevertheless, their higher voltage tolerance and faster carrier drift suggest that, with increased charge collection, their timing performance could approach or even surpass that of Si LGADs. Furthermore, these results demonstrate the strong potential of 4H-SiC LGADs as a robust platform for precision timing in future 4D tracking detectors, while also highlighting that signal charge is the dominant factor currently limiting their performance, indicating that further optimization of gain and drift structures will be essential for future development.

43 PARTICLE ACCELERATORS↗

Calibration and simulation of ionization signal and electronics noise in the ICARUS liquid argon time projection chamber

The ICARUS liquid argon time projection chamber (LArTPC) neutrino detector has been taking physics data since 2022 as part of the Short-Baseline Neutrino (SBN) Program. This paper details the equalization of the response to charge in the ICARUS time projection chamber (TPC), as well as data-driven tuning of the simulation of ionization charge signals and electronics noise. The equalization procedure removes non-uniformities in the ICARUS TPC response to charge in space and time. This work leverages the copious number of cosmic ray muons available to ICARUS at the surface. The ionization signal shape simulation applies a novel procedure that tunes the simulation to match what is measured in data. The end result of the equalization procedure and simulation tuning allows for a comparison of charge measurements in ICARUS between Monte Carlo simulation and data, showing good performance with minimal residual bias between the two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER 268 CED-3b Report

The goal of IER 268 was to collect information from the operation of the Godiva IV super-prompt critical assembly to support multi-physics modeling efforts. There were two types of systems deployed. One was a Photo-Doppler Velocimetry (PDV) system which used the reflection of laser light on the surface of the Godiva IV core. The other consisted of an MHD 240 detector with two other detectors (an MHD-241 and an Eljen EJ-325A) used for reference as the MHD-240 detector was moved. The collection is referred to as the MHD Detector in the narrative log. There were two types of Godiva operations performed to gather data. A series of super-prompt critical bursts were performed and data collected on both systems, tied to a common trigger. Separately, a series of delayed critical operations at various power levels was performed for a combination of MHD detector distances from Godiva and the presence and absence of a shield in the line of sight between Godiva and the MHD detector. This data was collected to determine the contribution of room return during the burst measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MU2E Experiment at FERMILAB: R&D, Design and Status

The Mu2e Experiment at Fermilab 1) will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus, µ - + N (A, Z) → e - + N (A, Z). This is an example of Charged Lepton Flavour Violation (CLFV) never observed experimentally. The dynamics of such a process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass (~104.967 MeV). If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between conversion and capture rate R µe ≤ 6 × 10 -17 (@ 90% C.L.). This will improve the current limit of a factor of 10 4 over previous experiments. The experiment complements and extends the current/planned searches (µ → eγdecay at MEG , mu3e) as well as the direct searches for new physics at the LHC. Indeed, such CLFV searches in the muon sector probe new physics at a mass scale inaccessible with direct searches at either present or planned high-energy colliders. To detect the muon conversion process, a very intense pulsed beam of negative muons is produced by means of a S-shape Superconducting Solenoid Magnet System that is organized into three subsystems: the Production Solenoid, the Transport Solenoid and the Detector Solenoid. The beam is stopped at 10 GHz on an Aluminum target inside the Detector Solenoid. The Mu2e detectors, also installed inside the Detector Solenoid, are a high-precision tracker made on ~20000 straw tubes, and a calorimeter composed of ~1500 pure CsI crystals organized in two disks and readout by two large area UV-extended Silicon Photomultipliers (SiPMs). The Detector Solenoid region is surrounded by a Cosmic Ray Veto based on scintillators readout by SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the muon anomalous precession frequency at the Muon g − 2 Experiment at Fermilab

The anomalous magnetic moment of the muon, $a_\mu = \frac{g-2}{2}$ is the fractional deviation of the muon $g$-factor from the value of 2. It emerges as the cumulative effect of the virtual particles participating in the muon interaction with a magnetic field via quantum loop corrections. Its value encodes all the possible interactions between the virtual particles and, for this reason, represents an important test of the Standard Model (SM). In particular, any deviation from the SM theoretical evaluation could be due to new physics contributions. The new Muon $g-2$ (E989) Experiment at Fermilab is currently operating to repeat and improve the previous E821 experiment at Brookhaven National Laboratory (BNL), aiming to reduce the experimental error by a factor of 4 to the final accuracy of 140 parts per billion (ppb). On April 7th, 2021, the E989 collaboration published the first result based on the first year of data taking (Run-1), measuring $a_\mu = 0.001~165~920~40(54)$ with a precision of 460 ppb. The measured value is consistent with the BNL measurement and strengthens the long-standing tension with the data-driven SM prediction to a combined discrepancy of 4.2$\sigma$. On the theory side, however, new efforts involving lattice-QCD techniques are starting to question the current consensus on the theoretical prediction, demanding new improvements on both the experimental and theoretical sides. The E989 collaboration is now finalizing the analysis of Run-2 and Run-3 data and a new publication is expected in the first half of 2023 with a combined statistical uncertainty of 200 ppb. The anomalous magnetic moment $a_\mu$ is measured as the ratio between the muon spin anomalous precession frequency, $\omega_a$, and the average magnetic field experienced by the muons as they circulate in the storage ring. This thesis presents a precession frequency analysis of the Run-1 data and an evaluation of the related systematic uncertainties. A new positron reconstruction developed for the analysis of the subsequent data-taking periods, aiming to reduce some of the major systematic uncertainties of the $\omega_a$ measurement, is presented. The author's involvement in the production of the Run-2/5 data and in the precise calibration of the detectors is discussed. Finally, the complete Run-1 $a_\mu$ result is presented.

43 PARTICLE ACCELERATORS↗

Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on the response of a water-Cherenkov detector of the Pierre Auger Observatory to atmospheric muons using an RPC hodoscope

Extensive air showers, originating from ultra-high energy cosmic rays, have been successfully measured through the use of arrays of water-Cherenkov detectors (WCDs). Sophisticated analyses exploiting WCD data have made it possible to demonstrate that shower simulations, based on different hadronic-interaction models, cannot reproduce the observed number of muons at the ground. The accurate knowledge of the WCD response to muons is paramount in establishing the exact level of this discrepancy. In this work, we report on a study of the response of a WCD of the Pierre Auger Observatory to atmospheric muons performed with a hodoscope made of resistive plate chambers (RPCs), enabling us to select and reconstruct nearly 600 thousand single muon trajectories with zenith angles ranging from 0$^\circ$ to 55$^\circ$. Comparison of distributions of key observables between the hodoscope data and the predictions of dedicated simulations allows us to demonstrate the accuracy of the latter at a level of 2%. As the WCD calibration is based on its response to atmospheric muons, the hodoscope data are also exploited to show the long-term stability of the procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the CMS high-level trigger during LHC Run 2

The CERN LHC provided proton and heavy ion collisions during its Run 2 operation period from 2015 to 2018. Proton-proton collisions reached a peak instantaneous luminosity of 2.1× 10 34 cm -2 s -1 , twice the initial design value, at √(s)=13 TeV. The CMS experiment records a subset of the collisions for further processing as part of its online selection of data for physics analyses, using a two-level trigger system: the Level-1 trigger, implemented in custom-designed electronics, and the high-level trigger, a streamlined version of the offline reconstruction software running on a large computer farm. This paper presents the performance of the CMS high-level trigger system during LHC Run 2 for physics objects, such as leptons, jets, and missing transverse momentum, which meet the broad needs of the CMS physics program and the challenge of the evolving LHC and detector conditions. Sophisticated algorithms that were originally used in offline reconstruction were deployed online. Highlights include a machine-learning b tagging algorithm and a reconstruction algorithm for tau leptons that decay hadronically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics potential of the IceCube Upgrade for atmospheric neutrino oscillations

The IceCube Upgrade is an extension of the existing IceCube Neutrino Observatory and will be deployed in the 2025–2026 austral summer. It will significantly improve the sensitivity of the detector to atmospheric neutrino oscillations. The existing 86-string IceCube array contains a dense in-fill known as DeepCore which is optimized to measure neutrinos with energies down to a few GeV. The IceCube Upgrade will consist of seven new densely instrumented strings placed within the DeepCore volume to further enhance the performance in the GeV energy range. The additional strings will feature new optical modules, each containing multiple photomultiplier tubes (PMTs), in contrast to the existing modules that each contain a single PMT. This will more than triple the number of PMT channels with respect to the current IceCube configuration, allowing for improved detection efficiency and reconstruction performance at GeV energies. We describe necessary updates to simulation, event selection, and reconstruction to accommodate the higher data rates observed by the upgraded detector and the addition of multi-PMT modules. We determine the expected sensitivity of the IceCube Upgrade to the atmospheric neutrino oscillation parameters sin 2 ⁡𝜃 23 and Δ⁢𝑚$^{2}_{32}$, the appearance of tau neutrinos and the neutrino mass ordering. The IceCube Upgrade will provide neutrino oscillation measurements that are of similar precision to those from accelerator experiments, while providing complementarity by probing higher energies and longer baselines, and with different sources of systematic uncertainties.

artificial neural networks↗

Photon classification with Gradient Boosted Trees at CLAS12

Dihadron semi-inclusive deep inelastic scattering (SIDIS) of 10.6 GeV longitudinally polarized electrons off the proton has been measured using the CLAS12 detector at Jefferson Lab. Two separate channels, π + π 0 and π - π 0 , were analyzed, requiring the reconstruction of diphoton pairs. Here, in this analysis, we addressed the problem of false neutral particles being reconstructed by CLAS12's event builder, polluting the otherwise physical combinatorial background underneath the π 0 peak. A photon classifier using a Gradient Boosted Trees (GBTs) architecture was trained with Monte Carlo simulations to reduce the amount of background π 0 's. We show that the nearest-neighbor features learned by the model lead to a substantial increase in signal vs. background discrimination compared to previous CLAS12 π^0 analyses. The machine learning approach recovers several times more dihadron statistics for the dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications

We developed a new front-end application-specific integrated circuit (ASIC) to upgrade the Maia X-ray microprobe. The ASIC instruments 32 configurable channels that perform either positive or negative charge amplification, pulse shaping, peak amplitude, and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1-μs peaking time, and a temperature of 248 K, an electronic resolution of 13 and 10 e- rms was measured with and without a silicon drift detector (SDD) sensor, respectively. A spectral resolution of 170-eV full-width at half-maximum (FWHM) at 5.9 keV was obtained with an 55Fe source. The channel linearity was better than ± 1% with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250-nm process with a footprint of 6.3 mm × 3.9 mm and dissipates 167 mW of static power.

Vernon, Emerson↗