Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Relationship of non-invasive quantification of myocardial blood flow to arrhythmic events in patients with implantable cardiac defibrillators

Background: Ischemia contributes to arrhythmogenesis though its role is incompletely understood. Abnormal myocardial perfusion measured by PET imaging may predict ventricular arrhythmias (VAs) in a high-risk population. Methods: Patients with implantable cardiac defibrillators who had undergone rubidium-82 cardiac PET imaging were identified. Patients were stratified by median MBF and MFR values for analysis. The Cox proportional hazards model was used to assess the impact of myocardial perfusion on survival free of VT independent of critical covariates. Results: A total of 159 patients (124 (78%) males, median age 65.9 years, IQR [56.76-72.63]) were followed for 1.43 years IQR [0.83-2.21]. VA occurred in 29 patients (23.7%). After adjustment for ejection fraction, age, and sex, impaired stress MBF was associated with an increased risk of VA (adjusted HR per ml/min/g 1.52, 95% CI (1.01-2.31), P = 0.04). Summed rest and stress scores were not predictive of VA. Among patients with severe LV dysfunction, stress MBF remained an independent predictor of VA (adjusted HR per 1 ml/min/g HR 1.69, 95% CI (1.03-11.36), P = 0.03), while residual EF, summed rest, and summed stress scores were not (P > 0.05). Conclusions: Impaired stress myocardial blood flow was associated with less survival free of ventricular arrhythmias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of {sup 18}F-FDG PET/CT in the diagnosis of cardiovascular implantable electronic device infections: A meta-analysis

Objective: We performed a meta-analysis evaluating the use of fluorine-18-fluorodeoxyglucose ({sup 18}F-FDG) positron-emission tomography (PET)/computed tomography (CT) in the diagnosis of cardiovascular implantable electronic device (CIED) infections. Background: PET/CT may be helpful in the diagnosis of CIED infection, particularly in patients with the absence of localizing signs or definitive echocardiographic findings. Methods: PubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov from January 1990 to April 2017 were searched for studies evaluating the accuracy of PET/CT in the diagnosis of CIED infections. Results: Overall, 14 studies involving 492 patients were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of CIED infection was 83% (95% CI 78%-86%) and the pooled specificity was 89% (95% CI 84%-94%). PET/CT demonstrated a higher sensitivity of 96% (95% CI 86%-99%) and specificity of 97% (95% CI 86%-99%) for diagnosis of pocket infections. Diagnostic accuracy for lead infections or CIED-IE was lower with pooled sensitivity of 76% (95% CI 65%-85%) and specificity of 83% (95% CI 72%-90%). Conclusion: Use of PET/CT in the evaluation of CIED infection has both a high sensitivity (83%) and specificity (89%) and deserves consideration in the management of selected patients with suspected CIED infections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR Imaging of Patients with Cardiac Implantable Electronic Devices (CIEDs): Implementing a Program and Optimizing CMR

Purpose of review: How to implement a program for MRI in patients with conditional and non-conditional (“legacy”) CIED. How to optimize safety and image quality in CMR? What the radiologists need to know: device programming, pre- and post-MRI CIED parameters. Recent findings: New Center for Medicare and Medicaid Services (CMS) guidelines have opened MRI to many patients with nonconditional devices. Newer pulse sequences for cardiac MRI (CMR) in device patients, including modified cine, late gadolinium enhancement and T1 mapping sequences, have resulted in improved image quality in device patients. We present several cases of CMR in device patients, including imaging of leadless pacemakers subcutaneous ICDs. Imaging pitfalls/artifacts in CMR interpretation are also presented. Summary: An organized institutional workflow with an established protocol involving proper patient screening, device programming, scan monitoring, and pre- and post-ICD interrogation minimizes risk in patients with conditional and non-conditional CIEDs. Although rare, significant changes in lead performance, power-on/reset, inappropriate pacing or ICD discharges and battery voltage depletion should be documented. High-quality scans with accurate scar characterization in CIED patients require the use of wideband sequences. CMS has recently acknowledged MRI as a reasonable test necessary for the diagnosis and treatment of beneficiaries with implanted CIEDs, improving the financial prospects and encouraging future developments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal diffusivity recovery and defect annealing kinetics of self-ion implanted tungsten probed by insitu transient grating spectroscopy

Tungsten is a promising candidate material for plasma-facing armour components in future fusion reactors. A key concern is irradiation-induced degradation of its normally excellent thermal transport properties. In this comprehensive study, thermal diffusivity degradation in ion-implanted tungsten and its evolution from room temperature (RT) to 1073 K is considered. Five samples were exposed to 20 MeV self-ions at RT to achieve damage levels ranging from 3.2 x 10 -4 to 3.2 displacements per atom (dpa). Transient grating spectroscopy with in-situ heating was then used to study thermal diffusivity evolution as a function of temperature. Using a kinetic theory model, an equivalent point defect density is estimated from the measured thermal diffusivity. The results showed a prominent recovery of thermal diffusivity between 450 K and 650 K, which coincides with the onset of mono-vacancy mobility. After 1073 K annealing samples with initial damage of 3.2 x 10 -3 dpa or less recover close to the pristine value of thermal diffusivity. For doses of 3.2 x 10 -2 dpa or higher, on the other hand, a residual reduction in thermal diffusivity remains even after 1073 K annealing. Transmission electron microscopy reveals that this is associated with extended, irradiation-induced dislocation structures that are retained after annealing. A sensitivity analysis shows that thermal diffusivity provides an efficient tool for the assessing total defect content in tungsten up to 1000 K.

36 MATERIALS SCIENCE↗

The detection of He in tungsten following ion implantation by laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) results are presented that provide depth-resolved identification of He implanted in polycrystalline tungsten (PC-W) targets by a 200 keV He+ ion beam, with a surface temperature of approximately 900 °C and a peak fluence of 10 23 m –2 . He retention, and the influence of He on deuterium and tritium recycling, permeation, and retention in PC-W plasma facing components are important questions for the divertor and plasma facing components in a fusion reactor, yet are difficult to quantify. The purpose of this work is to demonstrate the ability of LIBS to identify helium in tungsten; to investigate the sensitivity of laser parameters including, laser energy and gate delay, that directly influence the sensitivity and depth resolution of LIBS; and to perform a proof-of-principle experiment using LIBS to measure relative He intensities as a function of depth. In conclusion, the results presented demonstrate the potential not only to identify helium but also to develop a methodology to quantify gaseous impurity concentration in PC-W as a function of depth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermodynamic description of the Ti-Mo-Nb-Ta-Zr system and its implications for phase stability of Ti bio-implant materials

Titanium alloys are great candidates for applications such as biomedical implants that require biocompatibility, a low Young's modulus and a high strength. However, the properties of Ti alloys are highly dependent on phase stability. Here in the present work, a database for the Ti-Mo-Nb-Ta-Zr system has been evaluated using the CALPHAD (CALculation of PHAse Diagram) approach. The database was completed by evaluating the accuracy of previously modeled systems from literature and modeling systems that, to the best of the authors’ knowledge, had no modeling available in literature. All of the binary systems that make up the Ti-Mo-Nb-Ta-Zr system had previously modeled thermodynamic descriptions available in the literature and in most cases had multiple different descriptions available, which meant determining which previous thermodynamic description most accurately modeled the binary system with a direct focus on the bcc phase. In order to determine the accuracy of the multiple available thermodynamic descriptions from literature a combination of experimental data (also obtained from the literature) and computed thermochemical properties of the bcc phase from DFT (Density Functional Theory)-based first-principles calculations (present work) were used. Once the thermodynamic descriptions for the binary systems were chosen, focus shifted to the Ti-containing ternary systems. The Ti-Mo-Zr, Ti-Nb-Zr and Ti-Ta-Zr systems had previous thermodynamic description available in literature, which were incorporated without changes into the working database. The Ti-Mo-Ta, Ti-Nb-Ta and Ti-Mo-Nb systems had, to the authors’ knowledge, no descriptions available in the literature. Interaction parameters were determined for the Ti-Mo-Ta and Ti-Nb-Ta systems, and no interaction parameters were introduced for the Ti-Mo-Nb system. The database introduced by this work satisfactorily predicts the thermodynamics of the Ti-Mo-Nb-Ta-Zr system.

CALculation of PHAse Diagrams↗

Tuning the surface energy of fluorinated diamond-like carbon coatings via plasma immersion ion implantation plasma-enhanced chemical vapor deposition with 1,1,1,2-tetrafluoroethane

Here, we demonstrate an environmentally friendly and scalable method to create fluorine-doped diamond-like carbon (F-DLC) coatings using plasma immersion ion implantation plasma-enhanced chemical vapor deposition (PIII-PECVD) with 1,1,1,2-tetrafluoroethane. F-DLC films tend to have low wettability and good mechanical flexibility, which make them suitable for applications in biomedical devices and antibiofouling surfaces. We report on the effects of fluorine incorporation on the surface chemistry, surface energy, and morphology of these coatings, showing that our method is effective in increasing the fluorine content in the F-DLC up to 40%. We show that the addition of fluorine leads to a decrease in surface energy, which is consistent with a reduction in surface wettability.

Contact angle↗

Retrospective Comparison of Chemoradiotherapy Followed by Adjuvant Chemotherapy, With or Without Prior Gliadel Implantation (Carmustine) After Initial Surgery in Patients With Newly Diagnosed High-Grade Gliomas

Purpose: Retrospective study of patients treated for high-grade glioma, with or without biodegradable carmustine wafers and according to the Stupp protocol. Methods and Materials: Between May 2007 and June 2008, 65 patients underwent surgery for high-grade glioma, 28 had implantation of Gliadel and 37 patients did not. Patients received radiotherapy with concomitant temozolomide followed by 5 consecutive days of temozolomide every month for 6 months. Results: Overall median follow-up was 17.1 months; the median relapse-free survival (RFS) was 14 months with a RFS of 54% at 12 months, and 38% at 24 months. For patient with and without Gliadel, median and 1-year RFS were 12.9 months and 52% vs. 14 months and 42%, respectively (p = 0.89). According to pathology, Gliadel did not influence RFS of patients with Grade III or glioblastoma. However, for all patients, in multivariate analysis, non-methylated methylguanine methyltransferase (MGMT) was the only unfavorable prognostic factor of RFS (p = 0.017; HR 2.8; CI [1.2-7]). Median overall survival (OS) was 20.8 months; the OS rate at 12 months was 78.5%, and at 24 months 35.4%. For patients treated with and without Gliadel, median and 1-year OS were 20.6 months and 78.6% vs. 20.8 months and 78.4%, respectively. According to pathology, Gliadel did not influence OS of patients with Grade III or glioblastoma. For all patients, in multivariate analysis, unfavorable prognosticators for OS were non-methylated MGMT (p = 0.001; HR: 6.5; CI [2-20]) and irradiation dose <60 Gy (p = 0.02; HR: 6.3; CI [2-20]). With carmustine wafers, before irradiation, median gross tumor volume plus edema was 84 mL (27-229), whereas it was 68 mL (10-362) without carmustine (p = nonsignificant). Four cases of Grade 3 thrombopenia occurred, all in the carmustine wafer group. Conclusion: In patients with high-grade gliomas, adding Gliadel before performing a Stupp protocol did not improve survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kilovoltage Imaging of Implanted Fiducials to Monitor Intrafraction Motion With Abdominal Compression During Stereotactic Body Radiation Therapy for Gastrointestinal Tumors

Purpose: To assess intrafraction respiratory motion using a commercial kilovoltage imaging system for abdominal tumor patients with implanted fiducials and breathing constrained by pneumatic compression during stereotactic body radiation therapy (SBRT). Methods and Materials: A pneumatic compression belt limited respiratory motion in 19 patients with radiopaque fiducials in or near their tumor during SBRT for abdominal tumors. Kilovoltage images were acquired at 5- to 6-second intervals during treatment using a commercial system. Intrafractional fiducial displacements were measured using in-house software. The dosimetric effect of the observed displacements was calculated for 3 sessions for each patient. Results: Intrafraction displacement patterns varied between patients and between individual treatment sessions. Averaged over 19 patients, 73 sessions, 7.6% of craniocaudal displacements exceeded 0.5 cm, and 1.2% exceeded 0.75 cm. The calculated single-session dose to 95% of gross tumor volume differed from planned by an average of −1.2% (range, −11.1% to 4.8%) but only for 4 patients was the total 3-session calculated dose to 95% of gross tumor volume more than 3% different from planned. Conclusions: Our pneumatic compression limited intrafractional abdominal target motion, maintained target position established at setup, and was moderately effective in preserving coverage. Commercially available intrafractional imaging is useful for surveillance but can be made more effective and reliable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exceptional radiation resistance of hardened amorphous SiC under high-temperature hydrogen ion implantation

This study provides a compelling comparison of the structural and mechanical responses of single-crystal silicon carbide (sc-SiC), nanocrystalline silicon carbide (nc-SiC), and amorphous silicon carbide (am-SiC) to hydrogen ion implantation at 650 °C across three distinct fluences: low, medium, and high (LF, MF, HF). While both sc-SiC and nc-SiC exhibit blistering, microcracking, and exfoliation, am-SiC remains free of blisters, demonstrating superior resilience. Notably, nc-SiC, with its high density of stacking faults (SFs), requires a higher fluence to initiate blistering compared to sc-SiC. At high fluences, hydrogen accumulation at grain boundaries (GBs) in nc-SiC elevates internal gas pressure, intensifying exfoliation. In sc-SiC, blistering leads to increased hardness, whereas in nc-SiC, the degradation of the SF structure results in a reduction in hardness. In contrast, am-SiC undergoes structural relaxation during irradiation, resulting in a significant increase in hardness while maintaining its structural integrity, with only the formation of nano-sized spherical bubbles observed. Furthermore, these findings highlight the exceptional suitability of am-SiC for nuclear applications, where resistance to radiation-induced microcracking is critical.

36 MATERIALS SCIENCE↗

Helium effects on microstructural evolution in tempered martensitic steels: In situ helium implanter studies in HFIR

Microstructural evolutions in tempered martensitic steels (TMS) under neutron-irradiation, at fusion relevant He/dpa ratios and dpa rates, were characterized using a novel in situ He-implanter technique. F82H-mod3 was irradiated at 500 C in HFIR to a nominal 9 dpa and 190 or 380 appm He in both in the as-tempered (AT) and 20% cold-worked (CW) conditions. In all cases, a high number density of 1-2 nm He-bubbles were observed, along with fewer but larger 10 nm void-like faceted cavities. The He-bubbles form preferentially on dislocations and various interfaces. A slightly larger number of smaller He bubbles were observed in the CW condition. The lower He/dpa ratio produced slightly smaller and fewer He-bubbles. Comparisons of these observations to the results in nano-structured ferritic alloy (NFA) MA957 provide additional evidence that TMS may be susceptible to He-embrittlement as well as void swelling at fusion relevant He concentrations, while NFA are much more resistant to these degradation phenomena.

36 MATERIALS SCIENCE↗

Bubble morphology in U 3 Si 2 implanted by high-energy Xe ions at 300 °C

The microstructure modifications of a high-energy Xe implanted U 3 Si 2 , a promising accident tolerant fuel candidate, were characterized and are reported upon. The U 3 Si 2 pellet was irradiated at Argonne Tandem Linac Accelerator System (ATLAS) by an 84 MeV Xe ion beam at 300 °C. The irradiated specimen was then investigated using a series of transmission electron microscopy (TEM) techniques. A dense distribution of bubbles were observed near the range of the 84 MeV Xe ions. Xe gas was also found to accumulate at multiple types of sinks, such as dislocations and grain boundaries. Bubbles aggregated at those sinks are slightly larger than intragranular bubbles in lattice. At 300 °C, the gaseous swelling strain is limited as all the bubbles are below 10 nm, implying the promising fission gas behavior of U 3 Si 2 under normal operating conditions in light water reactors (LWRs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase decomposition and bubble evolution in Xe implanted U 3 Si 2 at 450°C

We report on the microstructure investigations of a U 3 Si 2 specimen implanted by 84 MeV Xe ions at 450°C. In the region that corresponds to the highest irradiation dose, U 3 Si 2 was found to decompose into a Si-enriched nanocrystalline USi matrix phase and a U-enriched amorphous inclusion phase. Density functional theory (DFT) calculations were used to help understand the decomposition mechanism. Xe bubbles of different morphologies were observed in USi nano-grains, on USi grain boundaries, and phase boundaries. Original U 3 Si 2 micro-grains were preserved on both sides of the irradiation damage peak region within the sample, implying a radiation dose threshold for decomposition of approximately 150 dpa at 450°C. In the preserved U 3 Si 2 region beneath the irradiation damage peak, where critical amount of Xe ions were deposited, a monomodal size distribution of intragranular Xe bubbles with an average size of 2.68 nm formed. In both decomposed and preserved U 3 Si 2 , the size of Xe bubbles was found to be lower than 50 nm. Based on this observation, the fission gas behavior of U 3 Si 2 is controllable and free of run-away swelling despite the occurrence of decomposition at this irradiation temperature. (C) 2019 Elsevier B.V. All rights reserved.

36 MATERIALS SCIENCE↗

Combined effect of injected interstitials and He implantation, and cavities inside dislocation loops in high purity Fe-Cr alloys

High purity Fe-Cr alloys with Cr content ranging from 3 to 14 wt% were irradiated by self-ions at 500 °C in dual-beam mode up to 157 displacements per atom (dpa), 17 appm He/dpa. Transmission electron microscopy (TEM) on focused ion beam foils revealed the depth distribution of irradiation induced cavities and dislocation loops. A detailed quantitative analysis of cavity microstructure was performed on Fe14%Cr, while Fe(3, 5, 10, 12)%Cr were analyzed qualitatively. A homogeneous distribution of small cavities were observed up to the damage peak. From surface to the damage peak, cavity number density increased almost linearly. The cavity microstructure changed drastically at and after the damage peak, where the size increased and number density decreased. Most notably, the microstructure consisted of a striking mixture of heterogeneously nucleated cavities inside dislocation loops and freely nucleated cavities in the matrix. Further, the depth-dependent void swelling increased continuously along the damage depth. This contrasts with most ion irradiation results where suppression of void swelling occurs adjacent to the damage peak due the injected interstitial effect. We hypothesize a plausible mechanism of the observed swelling variation based on a combined effect of the injected interstitials and helium implantation near the damage peak by comparing the results with those in pure iron irradiated under same conditions. This synergistic effect may develop cavity microstructures which do not necessarily reflect microstructures expected due to injected interstitial effect and can be easily wrongly interpreted. The depth dependent dislocation loop microstructure was studied qualitatively in Fe14%Cr sample. Up to the damage peak, a complex dense network of dislocations formed due to the interaction/impingement of the dislocation loops. Individually resolvable loops were only observed after the damage peak, where their association with cavities was noted. Furthermore helium also induced heterogeneous cavity nucleation on dislocations constituting a grain boundary and on pre-existing dislocation lines.

36 MATERIALS SCIENCE↗

Estimating dose to implantable cardioverter-defibrillator outside the treatment fields using a skin QED diode, optically stimulated luminescent dosimeters, and LiF thermoluminescent dosimeters

The purpose of this work was to determine the relative sensitivity of skin QED diodes, optically stimulated luminescent dosimeters (OSLDs) (microStar Trade-Mark-Sign DOT, Landauer), and LiF thermoluminescent dosimeters (TLDs) as a function of distance from a photon beam field edge when applied to measure dose at out-of-field points. These detectors have been used to estimate radiation dose to patients' implantable cardioverter-defibrillators (ICDs) located outside the treatment field. The ICDs have a thin outer case made of 0.4- to 0.6-mm-thick titanium ({approx}2.4-mm tissue equivalent). A 5-mm bolus, being the equivalent depth of the devices under the patient's skin, was placed over the ICDs. Response per unit absorbed dose-to-water was measured for each of the dosimeters with and without bolus on the beam central axis (CAX) and at a distance up to 20 cm from the CAX. Doses were measured with an ionization chamber at various depths for 6- and 15-MV x-rays on a Varian Clinac-iX linear accelerator. Relative sensitivity of the detectors was determined as the ratio of the sensitivity at each off-axis distance to that at the CAX. The detector sensitivity as a function of the distance from the field edge changed by {+-} 3% (1-11%) for LiF TLD-700, decreased by 10% (5-21%) for OSLD, and increased by 16% (11-19%) for the skin QED diode (Sun Nuclear Corp.) at the equivalent depth of 5 mm for 6- or 15-MV photon energies. Our results showed that the use of bolus with proper thickness (i.e., {approx}d{sub max} of the photon energy) on the top of the ICD would reduce the scattered dose to a lower level. Dosimeters should be calibrated out-of-field and preferably with bolus equal in thickness to the depth of interest. This can be readily performed in clinic.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optical properties of implanted Xe color centers in diamond

Optical properties of color centers in diamond have been the subject of intense research due to their promising applications in quantum photonics. Here in this work we study the optical properties of Xe related color centers implanted into nitrogen rich (type IIA) and an ultrapure, electronic grade diamond. The Xe defect has two zero phonon lines at 794 nm and 811 nm, which can be effectively excited using both green and red excitation, however, its emission in the nitrogen rich diamond is brighter. Near resonant excitation is performed at cryogenic temperatures and luminescence is probed under strong magnetic field. Finally, our results are important towards the understanding of the Xe related defect and other near infrared color centers in diamond.

36 MATERIALS SCIENCE↗

Erbium-Implanted WS 2 Flakes with Room-Temperature Photon Emission at Telecom Wavelengths

Optically addressable spin impurities in crystals along with device engineering provide an attractive route to realizing quantum technologies in the solid state, but reconciling disparate emitter and host material constraints for a given target application is often challenging. Rare-earth ions in two-dimensional (2D) materials could mitigate this problem given the atomic-like transitions of the emitters and the versatile nature of van der Waals systems. Here we combine ion implantation, confocal microscopy, and ab initio calculations to examine the photon emission of Er-doped WS 2 flakes. Optical spectroscopy reveals narrow, long-lived photoluminescence lines in the telecom band, which we activate after low-temperature thermal annealing. Spectroscopic and polarization-selective measurements show a uniform response across the ensemble, while the fluorescence brightness remains mostly unchanged with temperature, suggesting nonradiative relaxation channels are inefficient. Our results create opportunities for novel solid state devices coupling 2D-hosted, telecom-band emitters to photonic heterostructures separately optimized for photon manipulation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗