Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Industrial Assessment Center Technical Field Manager

The work to be performed involves managing Industrial Assessment Centers through a portfolio of activities. The core activities to be performed are in the general areas of; quality assurance of IAC operations, enhancement of the student IAC experience, program development for improving assessments and implementing smart manufacturing projects, program outreach to carry assessment successes beyond the program, and program integration with other DOE/manufacturing assistance programs. The IAC Technical Field Management Organization (FMO) works in close collaboration with DOE and provides technical management for the IAC program working under policy guidelines established by DOE.

42 ENGINEERING↗

Application of Electrochemical Methods to Molten Salt Reactors: Draft TLR Documenting Assessment of Electrochemical Monitoring

Nuclear Regulatory Commission (NRC) is developing the regulatory framework and technical expertise to support regulatory review of advanced non-water reactors, including molten salt reactors (MSRs). In an MSR, it is essential that the salt chemistry be maintained in a desired range in terms of redox potential for reliable operation and mitigation of corrosion to structural materials in the reactor, particularly the reactor vessel and heater exchanger. Measuring the redox potential of the salt in the reactor would also allow for the material lifetimes to be predicted more accurately, and chemical issues to be diagnosed more quickly. In addition to the chemical composition analysis by ICP-MS, electrochemical methods including potentiometry and linear wave scanning (LSC) were also used in molten salt reactor experiment (MSRE) for redox potential monitoring purposes. Electrochemcial methods offers unique advantages such as quick turnaround in results and unique capability of in-line monitoring of redox potential, and are considered popular electroanalytical techniques that can be used to monitor redox potentials and salt chemistry including impurities. The last two decades have seen significant advances in science and engineering of electrochemical methods for potential application to molten salts. The primary goal of this report is to assist NRC in understanding the monitoring of the salt chemistry by electrochemical methods and provide NRC reviewers with necessary information and tools to support regulatory review of MSR designs. This reports consists of two majors parts—Part 1, chemical potential of molten salts and effects by fission process in MSR; Part 2, assessment of electrochemical methods for application to MSRs. The TRLs of the typical relevant electrochemical methods for molten salts were evaluated based on the DOE TRL guidelines and upon a review of the current status of the electrochemical methods for two typical salt systems, fluoride and chloride, for MSRs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-Scale Modeling and Prototype Development for Electrochemical CO2 Reduction (CRADA Final Report)

In this CRADA project, Lawrence Livermore National Laboratory, Stanford University, SLAC National Laboratory, and TotalEnergies collaboratively executed a multidisciplinary investigation of electrochemical reduction of CO2 to produce sustainable fuels and chemicals. Overall, the project led to an increased understanding of the fundamental processes involved in CO2 electrolysis, from the atomistic scale to the full electrolyzer device scale, ultimately leading to design guidelines for CO2 electrolyzers that will help in their future commercialization. As the model systems, Ag- and Cu-based catalysts were investigated in various forms depending on the electrochemical platform that was utilized to study the activity, selectivity, and durability towards electrochemical CO2 reduction. By employing experimental, theoretical, and computational techniques, the project team experimentally validated multi-physics models, evaluated the experimental levers that lead to increased electrolyzer reaction selectivity and energy efficiency, and used computational optimization to design higher performance electrodes. The learnings of this project were extensively documented in publicly available peer-reviewed journal publications and conference presentations, which serve as a foundation for further work to build from.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microreactor Assembly Transportation Cask Model Description for Criticality Safety Validation Basis Assessment (Rev. 3)

Criticality safety analyses are completed on a transportation cask used for microreactor assembly shipment to provide an example of model and analysis to industry for reproducing this type of study on their microreactor fuel shipment. The fuel assembly considered is based on a gas-cooled microreactor (GC-MR), which utilizes HALEU fuel in the form of TRISO particles and utilizes various design options considered in industry designs. Various versions of this GC-MR assembly were studied, with and without YH 2 moderator, providing similar conclusions. The shipment cask design is revised based on an existing ES-3100 design, developed by Y-12 for the transport of highly enriched uranium (HEU), but is enlarged to hold the GC-MR fuel assembly. Criticality safety analysis for the cask/GC-MR fuel assembly package was performed using the CSAS6 sequence of SCALE6.3.2, utilizing the ENDF/B-VII.1 based continuous energy neutron library, and the analysis strictly follows the guideline from NRC reference reports. Different scenarios, e.g. normal operation, undamaged cask with water flooded, damaged cask with optimal water moderation, have been analyzed and it could be concluded the package would always have a large margin of subcriticality even packed in an infinite array. Sensitivity and similarity analyses are also performed using the TSUNAMI sequence of SCALE6.3.2, and the similarity analysis uses all the experiments from the ICSBEP Handbook with Highly Enriched Uranium (HEU), Intermediate and Mixed Enriched Uranium (IEU) and Low Enriched Uranium (LEU) systems, together with additional ones that are sponsored by the DNCSH program, and selected IRPhEP experiments using TRISO fuel and graphite moderator. These similarity analyses indicate that the dry nominal design has no similar benchmark experiments (ck values greater than 0.8), which may become problematic if more assemblies are shipped together (or a fully loaded core is shipped) and margin to criticality is reduced. However, the cask models with flooded assemblies exhibited similarities to many experiments with c k values greater than 0.8.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative Assessment of Battery Carbon Footprint Calculation Frameworks to Support U.S. Battery Manufacturing

A “battery passport” is a digital record that provides comprehensive information about an individual battery across its life cycle. This concept has been introduced by Battery Regulation (EU) 2023/1542 [1], which applies to batteries for electric vehicles (EVs), industrial batteries with a capacities greater than 2 kWh, and batteries for light means of transport (LMT) greater than 2kWh sold in the European Union (EU) market – impacting manufacturers and exporters across multiple jurisdictions globally. Among its reporting mandates, a key feature of battery passports is the requirement for a carbon footprint (CF) calculation methodology supported by enhanced data granularity to enable traceable and verifiable CF results. While no other jurisdictions have yet adopted formal battery passport requirements like the EU’s, some are developing CF calculation methods to comply with the EU Battery Regulation or are creating CF-related regulations that could evolve in a similar direction, reflecting the growing importance of battery CF guidelines for manufacturers seeking to remain competitive in global markets.

Zhang, Jingyi [Argonne National Laboratory (ANL), ↗

Federal Metering Guidance

The Federal Metering Guidance documents the metering provisions in EO 13834, Efficient Federal Operations and other metering related statutory requirements. This document provides the meter-related reporting requirements for Federal agencies, specifies a method to verify the existence of currently installed building-level meters, provides guidelines on prioritizing the implementation of advanced energy and water meters, sets the schedule for agencies to update their five-year metering plans, provides the minimum requirements that agencies must meet when updating their five-year metering plans along with recommend elements for an effective plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD Modeling of an 81" Single Slope Barrier Wall Drainage Window for on Grade and Sag Conditions

The main goal of this study is to design a drainage window in an 81" single slope barrier wall for on-grade and sag conditions that could replace the standard ODOT I-3 barrier catch basin. The ODOT design guidelines are as follows: a) Examine configurations of the opening to the flume behind the wall under the wall section to maximize conveyance of flow to a roadside ditch section. b) Examine window lengths and configurations to maximize hydraulic efficiency on a grade up to an absolute maximum window length of 20 ft. c) Use a minimum opening height of 4 in. and consider tapering to an increased height at the outlet to the flume to reduce the potential for debris clogging beneath the barrier section. On-grade locations are analyzed for longitudinal slope up to 5% and spread up to 10 ft. Sag locations, represented by pavement at zero longitudinal slope, are analyzed for water depths up to 18 in. The roadway cross section consists of a 10-ft shoulder at a 4.0% cross slope and pavement at a 1.6% cross slope. All surfaces are represented with Manning’s n = 0.015. Computational fluid dynamics (CFD) is used to perform the analysis. The modeling approach follows previous studies by the authors. The new design is similar to a slotted inlet: a rectangular opening cut into the bottom of a barrier (e.g., a temporary barrier or single slope barrier wall), which typically has a uniform cross section. Findings from laboratory tests of flow under Florida DOT barrier walls were used for additional validation of the modeling approach used in this study.

42 ENGINEERING↗

News Media Framing of Suicide Circumstances and Gender: Mixed Methods Analysis

Background: Suicide is a leading cause of death worldwide. Journalistic reporting guidelines were created to curb the impact of unsafe reporting; however, how suicide is framed in news reports may differ by important characteristics such as the circumstances and the decedent’s gender. Objective: This study aimed to examine the degree to which news media reports of suicides are framed using stigmatized or glorified language and differences in such framing by gender and circumstance of suicide. Methods: We analyzed 200 news articles regarding suicides and applied the validated Stigma of Suicide Scale to identify stigmatized and glorified language. We assessed linguistic similarity with 2 widely used metrics, cosine similarity and mutual information scores, using a machine learning–based large language model. Results: News reports of male suicides were framed more similarly to stigmatizing (P<.001) and glorifying (P=.005) language than reports of female suicides. Considering the circumstances of suicide, mutual information scores indicated that differences in the use of stigmatizing or glorifying language by gender were most pronounced for articles attributing legal (0.155), relationship (0.268), or mental health problems (0.251) as the cause.

59 BASIC BIOLOGICAL SCIENCES↗

Mitiq: A software package for error mitigation on noisy quantum computers

We introduce Mitiq, a Python package for error mitigation on noisy quantum computers. Error mitigation techniques can reduce the impact of noise on near-term quantum computers with minimal overhead in quantum resources by relying on a mixture of quantum sampling and classical post-processing techniques. Mitiq is an extensible toolkit of different error mitigation methods, including zero-noise extrapolation, probabilistic error cancellation, and Clifford data regression. The library is designed to be compatible with generic backends and interfaces with different quantum software frameworks. We describe Mitiq using code snippets to demonstrate usage and discuss features and contribution guidelines. We present several examples demonstrating error mitigation on IBM and Rigetti superconducting quantum processors as well as on noisy simulators.

97 MATHEMATICS AND COMPUTING↗

Impact of radiation on electronics and opto-electronics

In this chapter we will present the results of the impact of radiation on electronics and opto-electronics for two of the LHC experiments during Run 1 and Run 2. ATLAS results are presented in Section 6.1; CMS in Section 6.2. In Section 6.3 we will present a comparison between the two experiments, highlighting operational guidelines and proposing solutions to build the electronics and opto-electronics of the future LHC experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Penetration through Slots in Cylindrical Cavities Operating at Fundamental Cavity Modes in the Presence of Electromagnetic Absorbers

Placing microwave absorbing materials into a high-quality factor resonant cavity may in general reduce the large interior electromagnetic fields excited under external illumination. In this study, we aim to combine two analytical models we previously developed: 1) an unmatched formulation for frequencies below the slot resonance to model shielding effectiveness versus frequency; and 2) a perturbation model approach to estimate the quality factor of cavities in the presence of absorbers. The resulting model realizes a toolkit with which design guidelines of the absorber's properties and location can be optimized over a frequency band. Analytic predictions of shielding effectiveness for three transverse magnetic modes for various locations of the absorber placed on the inside cavity wall show good agreement with both full-wave simulations and experiments, and validate the proposed model. This analysis opens new avenues for specialized ways to mitigate harmful fields within cavities.

36 MATERIALS SCIENCE↗

Surface Meteorological Data from Sequim "Upstairs" PNNL Campus

Surface meteorological data (3m wind speed, wind direction, 2m air temperature, relative humidity, pressure, downwelling irradiance, total rainfall) gathered on the Sequim-PNNL campus ('upstairs'). Equipment is manufactured and calibrated by Campbell Scientific. Placement and height of sensors follows recommended guidelines of the NWS.

meteorological, meteorological data, Meteorologica↗

GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics

Data package for Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon This data is published under a CC0 license. The authors encourage data reuse and request attribution by referencing the below citations for the data packages and associated manuscript. Please cite as: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics. [Data Set] PNNL DataHub. doi: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. MSV000097435: GLBRC soil yearlong incubation 13C-SIP-Lipidomics [Data Set] MassIVE. doi:10.25345/C57659T3K Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon. In Prep This data package consists of compound-specific 13C SIP-lipidomics data from a yearlong tracer incubation experiment designed to investigate microbial lipid persistence in switchgrass bioenergy crop soils. In order to explore how lipid structure may modulate the persistence of C in soil lipids, we leveraged soils from two sites (Michigan - sandy texture, Wisconsin - silty texture) operated by the U.S. Department of Energy-funded Great Lakes Bioenergy Research Center (GLBRC). These sites had comparable climates, identical management practices, but contrasting soil textures, allowing us to assess the variability of lipid accrual or degradation in soils as well as provide insight regarding the degree to which edaphic properties may regulate the retention of soil lipids. Untargeted lipidomics analyses were performed to identify 13C-labeled lipids in the soil microbiome after long-term incubation. Soils were supplemented with 100 micrograms glucose per gram dry soil (99 atom % 13C or natural abundance for paired control) and incubated; samples were collected two months and one year after glucose addition. Lipid extracts (MPLEx) were analyzed by LC-MS/MS and identified using LIQUID. Calculation of isotopic enrichment of lipids was performed by targeted approach using TarMet to quantify lipid isotopologues and IsoCorrectoR to correct for natural abundance isotopes. Contents: Data package contents reported here are the first version and contain downstream analysis files for the raw LC-MS mass spectrometry files (.mzXML) deposited at the MassIVE database repository under accession MSV000097435 (80 experimental runs; 5.85 GB) | MassIVE DOI: 10.25345/C57659T3K. Support files include the additional data download 'Read Me' file containing data descriptor information. Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. Data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location. Available Data Downloads (0.3 GB): "GLBRC soil yearlong incubation 13C-SIP-Lipidomics_readme.txt" - 'Read Me' data package content file (txt) "GLBRC_DataPackage_analysis files" - Data processing files (Rmd) and saved intermediate data processing outputs (rds, csv, xlsx) "GLBRC_13C_lipidomics_dataset.xlsx" - processed data in tabular format (xlsx) Linked Software: LIQUID LC-MS Analysis Software | 10.5281/zenodo.6459462 Lipid Mini-On Software Tools | 10.5281/zenodo.1492803 pmartR Omics Statistical Software | 10.5281/zenodo.6108667 xcms (v4.3.3) TarMet (v1.1.1) IsoCorrectoR (1.24.0) Funding Acknowledgments: This research was supported by an Early Career Research Program award funded by the U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research (OBER) Genomic Science program under FWP 68292, FWP 07880 and EMSL Exploratory Research Project 51095. A portion of this work was performed in the William R. Wiley Environmental Molecular Sciences Laboratory, a national scientific user facility sponsored by OBER and located at Pacific Northwest National Laboratory (PNNL). PNNL is a multi-program national laboratory operated by Battelle for the DOE under Contract DE-AC05-76RLO1830.

Rempfert, Kaitlin R [Pacific Northwest National La↗

KS4A-Omics1.0_FspDS682

Soil fungi facilitate the translocation of inorganic nutrients from soil minerals to other microorganisms and plants. This ability is particularly advantageous in impoverished soils, because fungal mycelial networks can bridge otherwise spatially disconnected and inaccessible nutrient hotspots. However, the molecular mechanisms underlying fungal mineral weathering and transport through soil remains poorly understood. Here, we addressed this knowledge gap by directly visualizing nutrient acquisition and transport through fungal hyphae in a mineral doped soil micromodel using a multimodal imaging approach. Here, we observed how a representative of common saprotrophic soil fungi, Fusarium sp. DS 682, exhibited a mechanosensory response (thigmotropism) around obstacles and through pore spaces (~12 μm) in the presence of minerals.This study establishes the significance of fungal biology and nutrient translocation mechanisms in maintaining fungal growth under water and nutrient limitations in a soil-like microenvironment, using a high-throughput multi-omic analysis approach. Data package KS4A-Omics.1.0_FspDS682 (Publication: Fungal Mineral Weathering Mechanisms Revealed Through Direct Molecular Visualization) contents reported here are the first version (1.0) and contain pre- and post-processed data using high throughput data capture technologies for multi-omic analysis and integration, this data package contains raw and post-processed experimental data for X-Ray Absorption Near Edge Structure Spectroscopy (XANES/XRF), Optical Microscopy, Proteomics, Scanning Electron Microscope (SEM), Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS), X-Ray Diffraction Spectroscopy (XRD) files, and X- Ray Photoelectron Spectroscopy (XPS) using EMSL capabilities. This data package DOI contains a comprehensive collection of high-throughput multi-omics data and process metadata catalog. Support files include additional data download contents “Read Me” with dataset descriptor information and data source method application ontologies (see data dictionary section). Reported data download content is structured for compliance with reported guidelines provided by community standard initiatives and publisher stakeholder policies supporting FAIR data principles.

47 OTHER INSTRUMENTATION↗

WA-Omic_LA.1.0 - Quantitative Lipidomics, Metabolomics, and Sequencing (16S/ITS) Publication Data DOI Package

Corresponding Data Publication: "Rapid remodeling of the soil lipidome in response to a drying-rewetting event." This study reveals specific changes in lipids and metabolites that are indicative of stress adaptation, substrate use, and cellular recovery during soil drying and subsequent rewetting. Drought induced nutrient limitation was reflected in the lipidome and polar metabalome, both of which rapidly shifted (within hours) upon rewet. Reduced nutrient access in dry soil caused the replacement of glycerophospholipids with phosphorus-free lipids and impeded resource-expensive osmolyte accumulation. Elevated levels of ceramides and lipids with long chain polyunsaturated fatty acids, in dry soil suggests that lipids play an important role in fungal drought tolerance. Increasing abundance of bacterial glycerophospholipids and triacylglycerols with fatty acids typical of bacteria and polar metabolites suggest metabolic recovery in representative bacteria once the environmental conditions are conducive for growth. These results underscore the importance of the soil lipidome as a robust indicator of microbial community responses, especially at the short time scales of cell-environment reactions. Data package contents reported here are the first version and contain pre- and post-processed data acquisition and subsequent downstream analysis files using various data source instrument method techniques and Mass Spectroscopy (MS) EMSL capabilities. This publication data package DOI is a comprehensive high-throughput multi-omics data lifecycle collection containing processed data method metadata. Support files include additional data download “Read Me” file containing data descriptor information and data source application ontologies (see data dictionary). Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. For increased data availability and interoperability, GC-MS/LC-MS mass spectrometry datasets (Thermo .raw ) were deposited at the MassIVE database repository under the related data accession MSV000086931 and can be accessed by using the API. Statistical data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location.

Amplicon sequencing 16S ITS LC-MS/MS lipidomics mu↗

WA-Omic_LA.1.0 - Quantitative Lipidomics, Metabolomics, and Sequencing (16S/ITS) Publication Data DOI Package

Corresponding Data Publication: "Rapid remodeling of the soil lipidome in response to a drying-rewetting event." This study reveals specific changes in lipids and metabolites that are indicative of stress adaptation, substrate use, and cellular recovery during soil drying and subsequent rewetting. Drought induced nutrient limitation was reflected in the lipidome and polar metabalome, both of which rapidly shifted (within hours) upon rewet. Reduced nutrient access in dry soil caused the replacement of glycerophospholipids with phosphorus-free lipids and impeded resource-expensive osmolyte accumulation. Elevated levels of ceramides and lipids with long chain polyunsaturated fatty acids, in dry soil suggests that lipids play an important role in fungal drought tolerance. Increasing abundance of bacterial glycerophospholipids and triacylglycerols with fatty acids typical of bacteria and polar metabolites suggest metabolic recovery in representative bacteria once the environmental conditions are conducive for growth. These results underscore the importance of the soil lipidome as a robust indicator of microbial community responses, especially at the short time scales of cell-environment reactions. Data package contents reported here are the first version and contain pre- and post-processed data acquisition and subsequent downstream analysis files using various data source instrument method techniques and Mass Spectroscopy (MS) EMSL capabilities. This publication data package DOI is a comprehensive high-throughput multi-omics data lifecycle collection containing processed data method metadata. Support files include additional data download “Read Me” file containing data descriptor information and data source application ontologies (see data dictionary). Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. For increased data availability and interoperability, GC-MS/LC-MS mass spectrometry datasets (Thermo .raw ) were deposited at the MassIVE database repository under the related data accession MSV000086931 and can be accessed by using the API. Statistical data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location.

Amplicon sequencing 16S ITS LC-MS/MS lipidomics mu↗