Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Searching for dark absorption with direct detection experiments

We consider the absorption by bound electrons of dark matter in the form of dark photons and axion-like particles, as well as of dark photons from the Sun, in current and next-generation direct detection experiments. Experiments sensitive to electron recoils can detect such particles with masses between a few eV to more than 10 keV. For dark photon dark matter, we update a previous bound based on XENON10 data and derive new bounds based on data from XENON100 and CDMSlite. We find these experiments to disfavor previously allowed parameter space. Moreover, we derive sensitivity projections for SuperCDMS at SNOLAB for silicon and germanium targets, as well as for various possible experiments with scintillating targets (cesium iodide, sodium iodide, and gallium arsenide). The projected sensitivity can probe large new regions of parameter space. For axion-like particles, the same current direction detection data improves on previously known direct-detection constraints but does not bound new parameter space beyond known stellar cooling bounds. However, projected sensitivities of the upcoming SuperCDMS SNOLAB using germanium can go beyond these and even probe parameter space consistent with possible hints from the white dwarf luminosity function. We find similar results for dark photons from the sun. For all cases, direct-detection experiments can have unprecedented sensitivity to dark-sector particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A review of the developments of radioxenon detectors for nuclear explosion monitoring

Developments in radioxenon monitoring since the implementation of the International Monitoring System are reviewed with emphasis on the most current technologies to improve detector sensitivity and resolution. The nuclear detectors reviewed include combinations of plastic and NaI(Tl) detectors, high purity germanium detectors, silicon detectors, and phoswich detectors. The minimum detectable activity and calibration methods for the various detectors are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A rapid molecular precursor solid-state route to crystalline Fe 2 GeS 4 nanoparticles

Iron germanium sulfide (Fe 2 GeS 4 ) recently emerged as a potential thin film solar photovoltaic absorber. The introduction of the third element—germanium (Ge)—viewed as a solution for overcoming multiple barriers of a photovoltaic pyrite, confers stability to Fe 2 GeS 4 at elevated temperatures, typically required for accomplishing grain growth in Gen 2 thin film PV. A facile synthesis of Fe 2 GeS 4 nanoparticles from molecular precursors, comprising mechanical mixing of starting materials followed by a two-hour annealing in a sulfur-rich atmosphere is presented herein. Further processing of the resulting Fe 2 GeS 4 nanopowders at elevated temperatures demonstrates high thermal stability of Fe 2 GeS 4 (up to 500 °C), in comparison with pyrite, which shows onset of pyrrhotite upon heating above 160 °C. Based on the secondary crystalline phases formed, here we propose a mechanism of decomposition of Fe 2 GeS 4 at high temperatures. Films fabricated with Fe 2 GeS 4 were further annealed and revealed that Fe 2 GeS 4 withstands high temperatures in thin film.

36 MATERIALS SCIENCE↗

Pressure-driven density match nucleates metastable r8 phases from amorphous Si and Ge

The pressure–temperature phase behavior of covalent disordered solids such as amorphous silicon and germanium is complex. Questions remain on possible glass transitions, on polyamorphism via amorphous–amorphous transitions, on connections with liquid–liquid transitions, on structure-behavior relationships, and on their potential as precursor for novel methods for material discovery. Here we demonstrate experimentally the nucleation of a metastable, four-fold coordinated rhombohedral r8 phase from pure amorphous silicon and germanium upon room temperature compression at pressures below 10 GPa. Accompanying theory reveals a strong pressure-driven distortion of the bond angle transforming the starting tetrahedral low-density amorphous network to a distorted four-fold coordinated medium-density state. This state is of lower density than metallic high-density networks, resembles the crystalline r8 phase and initiates its nucleation. Our finding shows that polyamorphism is not the only possible transformation mode for these amorphous solids and that instead nucleation of interesting functional phases at potentially useful pressures is possible. Such novel access modes to metastable structures are critical for future exploitability and could be useful for other tetrahedral materials including carbon, where the related (bc8) post-diamond phase remains elusive. Our observed density match between an amorphous and a metastable crystalline phase clearly allows for a new phase transition pathway, while corresponding theory demonstrates how carefully validated atomistic simulations can guide prediction, discovery and synthesis of novel material structures.

Materials discovery↗

Exploring the Impact of Nuclear Data Uncertainties in Ultra-high Resolution Gamma Spectroscopy for Isotopic Analysis Using Approximate Bayesian Computation

High purity germanium (HPGe) currently provides the highest readily available resolution gamma detection for a broad range of radiation measurements, but microcalorimetry is a developing option that has considerably higher resolution even than HPGe. Superior microcalorimetry resolution offers the potential to better distinguish closely spaced X-rays and gamma-rays, a common challenge for the low energy spectral region near 100 keV from special nuclear materials, and the higher signal-to-background ratio also confers an advantage in detection limit. As microcalorimetry continues to develop, it is timely to assess the impact of uncertainties in detector and item response functions and in basic nuclear data, such as branching ratios and half-lives, used to interpret spectra in terms of the contributory radioactive isotopes. We illustrate that a new inference option known as approximate Bayesian computation (ABC) is effective and convenient both for isotopic inference and for uncertainty quantification for microcalorimetry. The ABC approach opens a pathway to new and more powerful implementations for practical applications than currently available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Cumulative Fission Yield Measurements with Fission Spectrum Neutrons on 235 U

Two isotopically-characterized targets of high-purity (99.84±0.03%) 235 U-oxide and a neutron dosimetry package were exposed to a pulsed neutron irradiation using the Godiva critical assembly at the National Criticality Experiments Research Center. Following irradiation, the fissioned targets were counted with a broad-energy germanium detector. Estimates of the total fissions for each target were made using measurements of well-known fission products. The total fission values were then used to measure the fission yields of 21 fission products with half-lives between 636 and 119,700 seconds. Mean values of seventeen of the measured fission products fell within the 95% confidence level of the Evaluated Nuclear Data Files VII.1/b (ENDF/B-VII.1) using the larger of the two uncertainties: 84g Br, 89 Rb, 91 Sr, 93 Y, 97 Zr, 101 Mo, 105 Ru, 128 Sn, 129 Sb, 130g Sb, 131 Sb, 131m Te, 133 I, 135 I, 141 Ba, 142 Ba, and 142 La. Seven isotopes were measured to better precision than is listed in the ENDF/B-VII.1 database: 89 Rb, 93 Y, 128 Sn, 129 Sb, 130g Sb, 131m Te, and 133 I. Four of the measured isotopes were found to be statistically different from the ENDF/B-VII.1 database: 94 Y, 134 Te, 134 I, and 138 Xe. Two of the isotopic analyses conducted in this paper fit the parent and daughter data simultaneously. The parent-daughter pairs measured in this way were the 134 Te/I and 142 Ba/La pairs. The fission yield results obtained in this way are unique, especially for 134 I, because the parent and daughter half-lives are so close. Here, given the limited number of direct measurements of the 134 Te/I pair from fast neutron induced fission and the seemingly high estimate for 134 Te from previous work, it is likely that the value in this paper is more accurate; however, additional measurements of this pair are needed to validate this assertion.

42 ENGINEERING↗

Validation of gamma-ray detection techniques for safeguards monitoring at natural uranium conversion facilities

Recent IAEA circulars and policy papers have sought to implement safeguards when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under the revised policy, IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO 2 (NO 3 ) 2 ) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. Nondestructive assay techniques using gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely way. This work investigated gamma-ray signatures of uranyl nitrate circulating in the UNCLE facility and evaluated various gamma-ray detector sensitivities to uranyl nitrate. These detector validation activities include assessing detector responses to the uranyl nitrate gamma-ray signatures for spectrometers based on sodium iodide, lanthanum bromide, and high-purity germanium detectors. The results of measurements under static and dynamic operating conditions at concentrations ranging from 10–90 g U/L of natural uranyl nitrate are presented. A range of gamma-ray lines is examined, including attenuation for transmission measurement of density and concentration. It was determined that transmission-corrected gamma-ray spectra provide a reliable way to monitor the 235 U concentration of uranyl nitrate solution in transfer pipes in NUCPs. Furthermore, existing predictive and analysis methods are adequate to design and realize practical designs. The 137 Cs transmission source employed in this work is viable but not optimal for 235 U densitometry determination. Validated simulations assessed the viability of 133 Ba and 57Co as alternative densitometry sources. All three gamma-ray detectors are viable for monitoring natural uranium feed; although high-purity germanium is easiest to interpret, it is, however, the least attractive as an installation instrument. Overall, for monitoring throughput in a facility such as UNCLE, emulating the uranium concentration and pump speeds of the Springfields conversion facility in the United Kingdom, an uncertainty of less than 0.17% is required in order to detect the diversion of 1 SQ of uranyl nitrate through changes in uranium concentration over an accountancy period of one year with a detection probability of 50%. As a result, calibrated gamma-ray detection systems are capable of determining the concentration of uranium content in NUCPs, it is only in combination with verifiable operator declarations and supporting data, such as flow rate and enrichment, that safeguards conclusions can be drawn.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FRAM v5.2 estimation of plutonium and uranium isotopics using digitized 3-D position-sensitive CdZnTe detectors

Gamma-ray spectroscopy is an important tool used in international safeguards to measure plutonium and uranium isotopics. Recently developed, digital, 3-D position-sensitive CdZnTe gamma-ray spectrometers are promising for safeguards, offering improved performance over commonly available CdZnTe systems, with energy resolutions approaching that of high-purity germanium. CdZnTe gamma-ray spectra from plutonium and uranium samples were processed using the commercially available software FRAM v5.2, a tool that estimates plutonium and uranium isotopics from high-purity germanium spectra, across a wide range of materials. Furthermore using digital CdZnTe systems 239 Pu/ 240 Pu isotopic composition and effective 240 Pu percentage are evaluated to within less than 3 sigma statistical measurement uncertainty across reactor to weapons-grade samples, while low and highly-enriched uranium are easily distinguished.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Compton scattering for gamma beam intensity measurements and perspectives at ELI-NP

Compton γ-ray sources have been used for over 30 years with new facilities being under construction or proposed. The gamma beam system under implementation at the Extreme Light Infrastructure - Nuclear Physics facility in Romania will deliver brilliant γ-ray beams with energies up to 19.5 MeV. Several instruments for measuring the parameters of the γ-ray beam are under development at ELI-NP. One of these instruments based on a High Purity Germanium detector is typically used for beam energy measurements at other facilities. Here we investigate the use of a High Purity Germanium detector to continuously monitor the intensity of the ELI-NP gamma beam by measuring the inelastic scattering of photons. This technique relies on both experimental and simulated data and it has been successfully tested during a recent experiment at the High Intensity γ-ray Source facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GEANT4 models of HPGe detectors for radioassay

Radiation transport models of two high purity germanium detectors, GeII and GeIII, located at the University of Alabama have been created in GEANT4 (Agostinelli et al., 2003) [1].These detectors have been used extensively for radioassay measurements of materials used in various low background experiments. The two models have been validated against actual data under several scenarios typically seen in radioassay measurements. Furthermore, the systematic uncertainties of the models for GeII and GeIII are estimated to be ~12% and ~9% respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UCGretina geant4 simulation of the GRETINA Gamma-Ray Energy Tracking Array

UCGretina, a geant4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton continuum. Both of these features are needed in order to accurately extract gamma-ray yields from spectra collected in in-beam gamma-ray spectroscopy measurements with beams traveling at v / c ≳0.3 at the National Superconducting Cyclotron Laboratory and the Facility for Rare Isotope Beams. In the process of developing the model, we determined that millimeter-scale layers of passive germanium surrounding the active volumes of the simulated crystals must be included in order to reproduce measured photopeak efficiencies. In conclusion, we adopted a simple model of effective passive layers and developed heuristic methods of determining passive-layer thicknesses by comparison of simulations and measurements for a single crystal and for the full array. Prospects for future development of the model are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

G4CMP: Condensed matter physics simulation using the G$\scriptsize{\mathrm{EANT}}$4 toolkit

G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Herein processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reproduces theoretical predictions and experimental observations such as phonon caustics, heat-pulse propagation times, and mean charge-carrier drift velocities. In addition to presenting the physics and features supported by G4CMP, this report outlines example applications from the dark matter and quantum information science communities. These communities are applying G4CMP to model and design devices for which the energy transported by phonons and charge carriers is germane to the performance of superconducting instruments and circuits placed on silicon and germanium substrates. The G4CMP package is available to download from GitHub: github.com/kelseymh/G4CMP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isomer spectroscopy of neutron-rich 168 Tb 103

In-flight fission of a 345 MeV per nucleon 238U primary beam on a 2 mm thick 9Be target has been used to produce and study the decays of a range of neutron-rich nuclei centred around the doubly mid-shell nucleus 170Dy at the RIBF Facility, RIKEN, Japan. The produced secondary fragments of interest were identified event-by-event using the BigRIPS separator. The fragments were implanted into the WAS3ABI position sensitive silicon active stopper which allowed pixelated correlations between implants and their subsequent β-decay. Discrete γ-ray transitions emitted following decays from either metastable states or excited states populated following beta decay were identified using the 84 coaxial high-purity germanium (HPGe) detectors of the EURICA spectrometer, which was complemented by 18 additional cerium-doped lanthanum bromide (LaBr3) fast-timing scintillation detectors from the FATIMA collaboration. This paper presents the internal decay of a metastable isomeric excited state in the odd-odd nucleus 168Tb, which corresponds to a single proton-neutron hole configuration in the valence maximum nucleus 170Dy. These data represent the first information on excited states in this nucleus, which is the most neutron-rich odd-odd isotope of terbium (Z=65) studied to date. Nilsson configurations associated with an axially symmetric, prolate-deformed nucleus are proposed for the 168Tb ground state the observed isomeric state by comparison with Blocked BCS-Nilsson calculations.

Gamma-ray spectroscopy and nuclear isomerism↗

Correlating Transport and Structural Properties in Li 1+ x Al x Ge 2– x (PO 4 ) 3 (LAGP) Prepared from Aqueous Solution

Li 1+ x Al x Ge 2– x (PO 4 ) 3 (LAGP) is a solid lithium-ion conductor belonging to the NASICON family, representing the solid solution of LiGe 2 (PO 4 ) 3 and AlPO 4 . The typical syntheses of LAGP either involve high-temperature melt-quenching, which is complicated and expensive, or a sol–gel process requiring costly organic germanium precursors. Herein, we report a simple method based on aqueous solutions without the need of ethoxide precursors. Using synchrotron and neutron diffraction, the crystal structure, the occupancies for Al and Ge, and the distribution of lithium were determined. Substitution of germanium by aluminum allows for an increased Li + incorporation in the material and the actual Li + content in the sample increases with the nominal Li + content and a solubility limit is observed for higher aluminum content. By means of impedance spectroscopy, an increase in the ionic conductivity with increasing lithium content is observed. Whereas the lithium ionic conductivity improves, due to the increasing carrier density, the bulk activation energy increases. This correlation suggests that changes in the transport mechanism and correlated motion may be at play in the Li 1+ x Al x Ge 2– x (PO 4 ) 3 solid solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large-scale integration of artificial atoms in hybrid photonic circuits

A central challenge in developing quantum computers and long-range quantum networks is the distribution of entanglement across many individually controllable qubits. Colour centres in diamond have emerged as leading solid-state ‘artificial atom’ qubits because they enable on-demand remote entanglement, coherent control of over ten ancillae qubits with minute-long coherence times and memory-enhanced quantum communication. A critical next step is to integrate large numbers of artificial atoms with photonic architectures to enable large-scale quantum information processing systems. So far, these efforts have been stymied by qubit inhomogeneities, low device yield and complex device requirements. Here we introduce a process for the high-yield heterogeneous integration of ‘quantum microchiplets’—diamond waveguide arrays containing highly coherent colour centres—on a photonic integrated circuit (PIC). We use this process to realize a 128-channel, defect-free array of germanium-vacancy and silicon-vacancy colour centres in an aluminium nitride PIC. Photoluminescence spectroscopy reveals long-term, stable and narrow average optical linewidths of 54 megahertz (146 megahertz) for germanium-vacancy (silicon-vacancy) emitters, close to the lifetime-limited linewidth of 32 megahertz (93 megahertz). We show that inhomogeneities of individual colour centre optical transitions can be compensated in situ by integrated tuning over 50 gigahertz without linewidth degradation. The ability to assemble large numbers of nearly indistinguishable and tunable artificial atoms into phase-stable PICs marks a key step towards multiplexed quantum repeaters and general-purpose quantum processors

36 MATERIALS SCIENCE↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Experimental Developments for the Lamb-Shift Investigation in Heavy Ions

Results of the latest commissioning experiment of a two arm transmission crystal x-ray spectrometer in combination with a high-performance position-sensitive mircostrip germanium detector are presented. Due to the low photon efficiency of only 10{sup -8}, both the position-sensitivity and the energy-resolution of the 2D-germanium detector are absolutely essential to perform experiments using crystal x-ray spectrometers. In this experiment we were aiming for a precise determination of the Ly-{alpha} transitions in H-like Pb{sup 81+} produced in collisions with a krypton gas jet at the ESR storage ring. Up to now, the most accurate determination of QED corrections to the ground state binding energy in a high-Z, H-like system was performed for H-like uranium with an accuracy on the 1% level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗