Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Geothermal Energy and Resilience in Arctic Countries

The eight Arctic countries have diverse energy systems but can be split into two distinct groups based on energy characteristics. The first group includes countries which are heavily gridconnected (Iceland, Norway, Sweden, and Finland); the second group includes countries with some grids as well as an abundance of remote microgrids, particularly in their more northern regions (Canada, Russia, the United States [Alaska], and Greenland). The primary energy source for both heat and power in remote communities is almost exclusively diesel. Geothermal energy is currently used in all eight Arctic countries, providing heat and sometimes electricity at utility scales and at the microgrid scale. However, the availability of geothermal resources is poorly defined in Arctic countries. We reframe geothermal heat and power as integrated energy systems, asking the question: are integrated geothermal energy systems - where available and economic - resilient solutions for communities in Arctic countries? Resilience attributes of integrated geothermal energy systems are identified, with a focus on microgrids and small-scale applications.

arctic energy↗

A comparison of economic evaluation models as applied to geothermal energy technology

Several cost estimation and financial cash flow models have been applied to a series of geothermal case studies. In order to draw conclusions about relative performance and applicability of these models to geothermal projects, the consistency of results was assessed. The model outputs of principal interest in this study were net present value, internal rate of return, or levelized breakeven price. The models used were VENVAL, a venture analysis model; the Geothermal Probabilistic Cost Model (GPC Model); the Alternative Power Systems Economic Analysis Model (APSEAM); the Geothermal Loan Guarantee Cash Flow Model (GCFM); and the GEOCOST and GEOCITY geothermal models. The case studies to which the models were applied include a geothermal reservoir at Heber, CA; a geothermal eletric power plant to be located at the Heber site; an alcohol fuels production facility to be built at Raft River, ID; and a direct-use, district heating system in Susanville, CA.

Ziman, G. M.↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost: Preprint

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This in turn is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in EGS binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost.

ambient temperature↗

Oilwell Conversion (Well API 121913310501) to Geothermal Heat Storage Well for Flexible Electricity Storage

Geothermal growth is limited by a lack of geographically dispersed high-temperature thermal resources and high initial upfront investment in characterization and well construction. This project intended to address the challenges of energy supply intermittency and enhance grid resilience, reliability, and energy security by storing energy provided from currently available renewable resources in the subsurface to harvest it a later time during at-peak energy demand. This project intended to improve geothermal adoption, reduce initial project risk, and improve price competitiveness through utilizing existing oil and gas infrastructure such as non-productive wells, non-economic fields, dry holes, and orphaned wells. The project also intended to address the lack of geographically dispersed thermal resources and enhance grid resilience, reliability, and energy security by introducing an economical method for storing energy from currently available renewable resources in the subsurface for usage during at-peak energy demand. During this research, the project furthered the understanding of the feasibility of utilizing abandoned oil and gas wells as geothermal heat storage wells. The project team investigated the heat storage and hydrogeological characteristics of subsurface reservoirs in the Illinois Basin to evaluate their response to heat injection for determining the evolution of temperature profiles and heat losses over time using existing and available data sets. The project team then performed modeling and simulation to evaluate the heat losses of returning fluids during heat extraction. The outputs were used to select an optimal candidate reservoir and location in Southern Illinois. The team designed and performed a small-scale field test in an existing oil well to refine the model and to demonstrate the permitting and regulatory pathways necessary for the conversion of oil and gas assets to geothermal use. The field test also serves as a proof of concept and can guide the procedures for future research and implementation. Additionally, the project team, conducted initial market research and customer discovery to develop a go to market strategy for an Advanced Geothermal Energy Storage (AGES) system. The project team in this research also identified the parameters to be refined in future research, to improve the current go to market strategy economic model. To this end several subject matter experts were also identified to assist in future research with geothermal infrastructure setup, energy storage policy and law, energy storage market demand, potential siting based on demand etc. Future research will involve further sophistication of the site commercial modeling, implementing a larger-scale test, and further refinement of the thermodynamic modeling/simulation process. The output will be lifecycle costs and economics suitable for comparison to alternative approaches from a validated full-scale demonstration for venture capital investment into this technology. The project successfully demonstrated the ability to leverage existing oilfield infrastructure, permits, and land access and leasing agreements, to enable geothermal storage projects to come online faster and cheaper than a greenfield development could. This technology could allow for greater energy independence and security through long-term energy storage solutions. The longer duration allows for greater storage for renewables currently limited by hours-long storage durations of lithium-ion. The AGES system would support the growth of renewable energy farms, and provide greater opportunities for a cleaner energy infrastructure.

15 GEOTHERMAL ENERGY↗

Community Geothermal: Energy, Cost, and Carbon Modeling for District Design - Ann Arbor, MI

This data includes results on an analysis of existing and projected energy, cost, and carbon for the City of Ann Arbor - District Geothermal Design and Deployment to Equitably Decarbonize Low Income Neighborhoods in Ann Arbor project. The scope of the project includes designing and implementing a geothermal district heating and cooling system that reduces thermal heating and cooling load by 75% and greenhouse gas emissions by 40% in the project area (262 households, 6 commercial buildings). The existing neighborhood was modeled using Design Builder, an EnergyPlus software, to understand the current energy load. The energy model was then flipped to reflect the designed district geothermal heating and cooling system to project the effect on energy, carbon, and cost. This dataset includes the analysis files utilized and created for this study. There are 3 categories of data: 1) existing/benchmarking, 2) energy modeling, and 3) post processed calculations. This follows the methodology and process of the project team, which is fully explained in file 00_Technical Economic Environmental Assessment. All uses of data are referenced throughout this assessment to their respective files included below.

15 GEOTHERMAL ENERGY↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

15 GEOTHERMAL ENERGY↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

Chainer, Timothy J.↗

Monitoring deformation at the Geysers Geothermal Field, California using C-band and X-band interferometric synthetic aperture radar

In this study, we resolve deformation at The Geysers Geothermal Field using two distinct sets of interferometric synthetic aperture radar (InSAR) data. The first set of observations utilize archived European Space Agency C-band synthetic aperture radar data from 1992 through 1999 to image the long-term and large-scale subsidence at The Geysers. The peak range velocity of approximately 50 mm/year agrees with previous estimates from leveling and global positioning system observations. Data from a second set of measurements, acquired by TerraSAR-X satellites, extend from May 2011 until April 2012 and overlap the C-band data spatially but not temporally. These X-band data, analyzed using a combined permanent and distributed scatterer algorithm, provide a higher density of scatterers (1122 per square kilometer) than do the C-band data (12 per square kilometer). The TerraSAR-X observations resolve 1 to 2 cm of deformation due to water injection into a Northwest Geysers enhanced geothermal system well, initiated on October 2011. Lastly, the temporal variation of the deformation is compatible with estimates from coupled numerical modeling.

58 GEOSCIENCES↗

Crossing the Barriers: An Analysis of Permitting Barriers to Geothermal Development and Potential Improvement Scenarios

Developers have identified many non-technical barriers to geothermal power development, including permitting. Activities required for permitting, such as the associated environmental reviews, can take a considerable amount of time and delay project development. This paper discusses the impacts to geothermal development timelines due to the permitting challenges, including the regulatory framework, environmental review process, and ancillary permits. We identified barriers that have the potential to prevent geothermal development or delay timelines and defined improvement scenarios that could assist in expediting geothermal development and permitting timelines and lead to the deployment of additional geothermal resources by 2030 and 2050: (1) the creation of a centralized federal geothermal permitting office and utilization of state permit coordination offices as well as (2) an expansion of existing categorical exclusions applicable to geothermal development on Bureau of Land Management public lands to include the oil and gas categorical exclusions passed as part of the Energy Policy Act of 2005. We utilized the Regional Energy Deployment System (ReEDS) and the Geothermal Electricity Technology Evaluation Model (GETEM) to forecast baseline geothermal deployment based on previous analysis of geothermal project development and permitting timelines. The model results forecast that reductions in geothermal project timelines can have a significant impact on geothermal deployment. For example, using the ReEDS model, we estimated that reducing timelines by two years, perhaps due to the creation of a centralized federal geothermal permitting office and utilization of state permit coordination offices, could result in deployment of an additional 204 MW by 2030 and 768 MW by 2050 - a 13% improvement when compared to the business as usual scenario. The model results forecast that a timeline improvement of four years - for example with an expansion of existing categorical exclusions coupled with the creation of a centralized federal geothermal permitting office and utilization of state permit coordination offices - could result in deployment of an additional 2,529 MW of geothermal capacity by 2030 and 6,917 MW of geothermal capacity by 2050 - an improvement of 116% when compared to the business as usual scenario. These results suggest that reducing development timelines could be a large driver in the deployment of geothermal resources.

15 GEOTHERMAL ENERGY↗

DEEPEN Global Standardized Categorical Exploration Datasets for Magmatic Plays

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. As part of the development of the DEEPEN 3D play fairway analysis (PFA) methodology for magmatic plays (conventional hydrothermal, superhot EGS, and supercritical), weights needed to be developed for use in the weighted sum of the different favorability index models produced from geoscientific exploration datasets. This was done using two different approaches: one based on expert opinions, and one based on statistical learning. This GDR submission includes the datasets used to produce the statistical learning-based weights. While expert opinions allow us to include more nuanced information in the weights, expert opinions are subject to human bias. Data-centric or statistical approaches help to overcome these potential human biases by focusing on and drawing conclusions from the data alone. The drawback is that, to apply these types of approaches, a dataset is needed. Therefore, we attempted to build comprehensive standardized datasets mapping anomalies in each exploration dataset to each component of each play. This data was gathered through a literature review focused on magmatic hydrothermal plays along with well-characterized areas where superhot or supercritical conditions are thought to exist. Datasets were assembled for all three play types, but the hydrothermal dataset is the least complete due to its relatively low priority. For each known or assumed resource, the dataset states what anomaly in each exploration dataset is associated with each component of the system. The data is only a semi-quantitative, where values are either high, medium, or low, relative to background levels. In addition, the dataset has significant gaps, as not every possible exploration dataset has been collected and analyzed at every known or suspected geothermal resource area, in the context of all possible play types. The following training sites were used to assemble this dataset: - Conventional magmatic hydrothermal: Akutan (from AK PFA), Oregon Cascades PFA, Glass Buttes OR, Mauna Kea (from HI PFA), Lanai (from HI PFA), Mt St Helens Shear Zone (from WA PFA), Wind River Valley (From WA PFA), Mount Baker (from WA PFA). - Superhot EGS: Newberry (EGS demonstration project), Coso (EGS demonstration project), Geysers (EGS demonstration project), Eastern Snake River Plain (EGS demonstration project), Utah FORGE, Larderello, Kakkonda, Taupo Volcanic Zone, Acoculco, Krafla. - Supercritical: Coso, Geysers, Salton Sea, Larderello, Los Humeros, Taupo Volcanic Zone, Krafla, Reyjanes, Hengill. **Disclaimer: Treat the supercritical fluid anomalies with skepticism. They are based on assumptions due to the general lack of confirmed supercritical fluid encounters and samples at the sites included in this dataset, at the time of assembling the dataset. The main assumption was that the supercritical fluid in a given geothermal system has shared properties with the hydrothermal fluid, which may not be the case in reality. Once the datasets were assembled, principal component analysis (PCA) was applied to each. PCA is an unsupervised statistical learning technique, meaning that labels are not required on the data, that summarized the directions of variance in the data. This approach was chosen because our labels are not certain, i.e., we do not know with 100% confidence that superhot resources exist at all the assumed positive areas. We also do not have data for any known non-geothermal areas, meaning that it would be challenging to apply a supervised learning technique. In order to generate weights from the PCA, an analysis of the PCA loading values was conducted. PCA loading values represent how much a feature is contributing to each principal component, and therefore the overall variance in the data.

15 GEOTHERMAL ENERGY↗

Archuleta County CO Lineaments

This layer traces apparent topographic and air-photo lineaments in the area around Pagosa springs in Archuleta County, Colorado. It was made in order to identify possible fault and fracture systems that might be conduits for geothermal fluids. Geothermal fluids commonly utilize fault and fractures in competent rocks as conduits for fluid flow. Geothermal exploration involves finding areas of high near-surface temperature gradients, along with a suitable plumbing system that can provide the necessary permeability. Geothermal power plants can sometimes be built where temperature and flow rates are high. To do this, georeferenced topographic maps and aerial photographs were utilized in an existing GIS, using ESRI ArcMap 10.0 software. The USA_Topo_Maps and World_Imagery map layers were chosen from the GIS Server at server.arcgisonline.com, using a UTM Zone 13 NAD27 projection. This line shapefile was then constructed over that which appeared to be through-going structural lineaments in both the aerial photographs and topographic layers, taking care to avoid manmade features such as roads, fence lines, and right-of-ways. These lineaments may be displaced somewhat from their actual location, due to such factors as shadow effects with low sun angles in the aerial photographs. Note: This shape file was constructed as an aid to geothermal exploration in preparation for a site visit for field checking. We make no claims as to the existence of the lineaments, their location, orientation, and nature.

15 GEOTHERMAL ENERGY↗

Feasibility of Deep Direct-Use Geothermal on the West Virginia University Campus-Morgantown, WV

In 2010, research completed by the Southern Methodist University (SMU) Geothermal Laboratory estimated temperatures at reasonable drilling depths in the state of West Virginia (WV) were in the temperature range desirable for district heating. This higher temperature region extends from north-central WV (Monongalia County) to southeastern WV (Greenbrier County). The Morgantown campus of West Virginia University (WVU) is located within the north-central region, and as part of the 2016 study on Low-temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB), Morgantown is identified as one of the priority locations for further analysis of the potential for deep direct-use (DDU) of geothermal energy. In this project, the feasibility of developing a Geothermal District Heating and Cooling (GDHC) system for the WVU campus in Morgantown, WV, to replace the current coal-fired steam heating and cooling system, is evaluated.

15 GEOTHERMAL ENERGY↗

Optimal Ground Source Heat Pump System Design

Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

42 ENGINEERING↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, and has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second mode; and, in response, the data center cooling system is switched to the second mode. The second mode is different than the first mode.

42 ENGINEERING↗

How to sustain a CO 2 -thermosiphon in a partially saturated geothermal reservoir: Lessons learned from field experiment and numerical modeling

CO 2 has been proposed as a working fluid for geothermal energy production because of its ability to establish a self-sustaining CO 2 thermosiphon, taking advantage of the strong temperature dependence of CO 2 density. To test the concept of CO 2 heat extraction, in January 2015 a CO 2 thermosiphon was operated at the SECARB Cranfield Site, Cranfield, Mississippi, where a brine-saturated sand at a depth of 3.2 km has been under near continuous CO 2 flood since December 2009 as part of a U.S. Department of Energy demonstration of CO 2 sequestration, resulting in a partially saturated reservoir surrounding a well pair. The lateral distance between the producer and injector was 112 m at reservoir depth, a distance considered pre-commercial in scale, but great enough that thermal breakthrough was still not significant after several years of injection. Instead of producing power with a turbine, heat was extracted heat from recirculated fluid using a heat exchanger and portable chiller. The well field and surface equipment were instrumented to compare field observations with predicted responses from numerical models. Thermosiphon flow could be initiated by venting, but thereafter flow rate steadily declined, indicating that the thermosiphon was not sustainable. To model the system, the capability of T2Well, a fully coupled wellbore/reservoir numerical simulator, was expanded to enable simulation of the entire loop of fluid circulation in the fully-coupled system consisting of the injection/production wells, the reservoir, and the surface devices (heat exchanger, flow-rate regulator etc.). Combined with the newly developed TOUGH2 equation of state module called EOS7CMA, the enhanced T2 Well was used prior to the field experiment to simulate the circulation of a CO 2 -H 2 O-CH 4 mixture in a model geothermal system patterned after the Cranfield demonstration test. The model predicted that a sustainable thermosiphon could be achieved. After the field thermosiphon did not achieve the pre-test prediction of flow rates and thermosiphon sustainability, the numerical model was modified to improve realism and calibrate certain processes; it was then able to reproduce the major phenomena observed in the field. In a series of sensitivity studies, many factors were found that could potentially contribute to the failing of a sustainable thermosiphon. These factors could be categorized as two types: factors that increase the resistance to flow and factors that increase heat loss of the working fluid. In conclusion, the lessons learned can be applied to both future modeling and to achieving CO 2 -based geothermal reservoir exploitation.

15 GEOTHERMAL ENERGY↗

Thermal-Hydrological-Mechanical Modelling of Stockton University Reservoir Cooling System, Fine Scale Stress Test Modelling

Mesh, properties, initial conditions, injection/withdrawal rates for modelling thermal, hydrological, and mechanical effects of fluid injection to and withdrawal from ground for Stockton University reservoir cooling system (aquifer storage cooling system), Galloway, New Jersey, for unscheduled two hour injection at 133 % designed capacity, on fine scale grid, with some results. Second simulation of J.T. Smith, E. Sonnenthal, P. Dobson, P. Nico, and M. Worthington, 2021. Thermal-hydrological-mechanical modeling of Stockton University reservoir cooling system, Proceedings of the 46th Workshop on Geothermal Reservoir Engineering, Stanford University, SGP-TR-218, from which Figures 6-9, pertain.

15 GEOTHERMAL ENERGY↗

Geothermal Thermoelectric Generation (G-TEG) with Integrated Temperature Driven Membrane Distillation and Novel Manganese Oxide for Lithium Extraction

Southern Research Institute (Southern) teamed with partners Novus Energy Technologies (Novus), Carus Corporation (Carus), and Applied Membrane Technology, Inc. (AMT) to develop an innovative Geothermal ThermoElectric Generation (G-TEG) system specially designed to both generate electricity and extract high-value lithium (Li) from low-temperature geothermal brines. The process combined five modular technologies including – silica removal, nanofiltration (NF), membrane distillation (MD), Mn-oxide sorbent for Li recovery, and TEG. This project provides a proof of concept for each of these technologies. The first step in the process is silica precipitation through metal addition and pH adjustment to prevent downstream scaling in membrane processes. Next, the geothermal brine is concentrated with the first of a two stage MD system. The first stage MD system is made of a high-temperature material to withstand geothermal brine temperatures up to 150C.° The first stage MD is integrated with a G-TEG module for simultaneous energy generation. The release of energy from the MD permeate drives heat transfer across the TE module, producing electricity. The first stage MD concentrate is then treated utilizing an NF system to remove Ca 2+ and Mg 2+ . The NF concentrate will be disposed in the well by reinjection. The NF permeate undergoes concentration in a second stage of MD (polymeric material) to further concentrate Li in the NF permeate and enhance the efficiency of the downstream Li recovery process utilizing a Mn-oxide sorbent. Permeate from both the stages of the MD can be beneficially utilized as the permeates will contain less contaminants than the feed water. The concentrated geothermal brines are then contacted with the Mn-oxide sorbent. After Li from the geothermal brine is adsorbed on the sorbent, HCl is then utilized to regenerate the sorbent and recover the Li. The research and development project showed that the Si removal goal (>80%) could be achieved by increasing the pH of the brine and adding Fe 3+ under several scenarios. The NF was also successful in achieving significant Ca 2+ and Mg 2+ removal (~80%) while retaining most Li in the permeate for high strength brines. MD experiments showed that geothermal brines could be significantly concentrated with little fouling due to pre-treatment.

15 GEOTHERMAL ENERGY↗

Comparative study of control strategies for hybrid GSHP system in the cooling dominated climate

The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7 [1]. In the end, the simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the reduced size well field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗