Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of an IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Evaluation of Lung Microwave Ablation in a Porcine Tumor Mimic Model

To evaluate the microwave ablation of created tumor mimics in the lung of a large animal model (pigs), with examination of the ablative synergy of multiple antennas. Fifty-six tumor-mimic models of various sizes were created in 15 pigs by using barium-enriched minced collected thigh muscle injected into the lung of the same animal. Tumors were ablated under fluoroscopic guidance by single-antenna and multiple-antenna microwaves. Thirty-five tumor models were treated in 11 pigs with a single antenna at 75 W for 15 min, with 15 measuring 20 mm in diameter, 10 measuring 30 mm, and 10 measuring 40 mm. Mean circularity of the single-antenna ablation zones measured 0.64 {+-} 0.12, with a diameter of 35.7 {+-} 8.7 mm along the axis of the antenna and 32.7 {+-} 12.8 mm perpendicular to the feeding point. Multiple-antenna delivery of 75 W for 15 min caused intraprocedural death of 2 animals; modified protocol to 60 W for 10 min resulted in an ablation zone with a diameter of 43.0 {+-} 7.7 along the axis of the antenna and 54.8 {+-} 8.5 mm perpendicular to the feeding point; circularity was 0.70 {+-} 0.10. A single microwave antenna can create ablation zones large enough to cover lung tumor mimic models of {<=}4 cm with no heat sink effect from vessels of {<=}6 mm. Synergic use of 3 antennas allows ablation of larger volumes than single-antenna or radiofrequency ablation, but great caution must be taken when 3 antennas are used simultaneously in the lung in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Control angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Term Effects of Ankaferd Hemostat for Renal Artery Embolization: An Experimental Study

Renal artery embolization (RAE) is a minimally invasive therapeutic technique that is utilized in a number of disorders. Ankaferd is a novel hemostatic agent with a new mechanism of action independent of clotting factors. We used Ankaferd for RAE in a sheep model. Seven adult female sheep were included in the study. Selective renal arteriogram using 5-F diagnostic catheter was performed to make sure that each kidney was fed by a single renal artery and the animal had normal renal vasculature. Coaxial 2.7-F microcatheter was advanced to the distal main renal artery. Under fluoroscopic guidance, 2 mL of Ankaferd mixed with 2 mL of nonionic iodinated contrast agent was slowly injected. Fluoroscopy was used to observe the deceleration of flow and stagnation. Control renal angiograms were performed just after embolization. After the procedure, the animals were observed for 1 day and then sacrificed with intravenous sodium thiopental. The technical success was observed in seven of the seven animals.. After embolization procedure, none of the animals died or experienced a major systemic adverse event. On macroscopic examination of the embolized kidneys, thrombus at the level of main renal artery formed after Ankaferd embolization was more compact compared with the thrombi that was not Ankaferd-associated, which was observed elsewhere. Microscopically, majority of the renal tubular cells (80-90 %) were necrotic, and there was epithelial cell damage in a small portion of the cells (10-20 %). RAE was safe and effective in the short-term with Ankaferd in studied animals. Further studies should be conducted to better delineate the embolizing potential of this novel hemostatic agent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of the Nonlethal Margin Inside the Visible 'Ice-Ball' During Percutaneous Cryoablation of Renal Tissue

Objective. The study was designed to determine the distance between the visible 'ice-ball' and the lethal temperature isotherm for normal renal tissue during cryoablation. Methods. The Animal Care Committee approved the study. Nine adult swine were used: three to determine the optimum tissue stain and six to test the hypotheses. They were anesthetized and the left renal artery was catheterized under fluoroscopy. Under MR guidance, the kidney was ablated and (at end of a complete ablation) the nonfrozen renal tissue (surrounding the 'ice-ball') was stained via renal artery catheter. Kidneys were explanted and sent for slide preparation and examination. From each slide, we measured the maximum, minimum, and an in-between distance from the stained to the lethal tissue boundaries (margin). We examined each slide for evidence of 'heat pump' effect. Results. A total of 126 measurements of the margin (visible 'ice-ball'-lethal margin) were made. These measurements were obtained from 29 slides prepared from the 6 test animals. Mean width was 0.75 {+-} 0.44 mm (maximum 1.15 {+-} 0.51 mm). It was found to increase adjacent to large blood vessels. No 'heat pump' effect was noted within the lethal zone. Data are limited to normal swine renal tissue. Conclusions. Considering the effects of the 'heat pump' phenomenon for normal renal tissue, the margin was measured to be 1.15 {+-} 0.51 mm. To approximate the efficacy of the 'gold standard' (partial nephrectomy, {approx}98 %), a minimum margin of 3 mm is recommended (3 Multiplication-Sign SD). Given these assumptions and extrapolating for renal cancer, which reportedly is more cryoresistant with a lethal temperature of -40 Degree-Sign C, the recommended margin is 6 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation of Large Renal Angiomyolipoma: Median-Term Follow-Up

Purpose. To study the feasibility of percutaneous radiofrequency ablation (RFA) of large angiomyolipomas (AMLs) using saline-cooled electrodes. Materials and Methods. Institutional Review Board approval for the study was received. Four patients (all female, age range 33-67 years) with large AMLs (maximal axis 6.1-32.4 cm) not suitable for embolotherapy or surgery consented to a trial of RFA. Procedures were performed under computerized tomographic guidance using 14G saline-infused electrodes. Two ablations (diameter 4-7 cm) were undertaken in each patient. Variables studied were technical success, treatment safety, alteration of tumor consistency, tumor size, effect on renal function, and medium-term freedom from haemorrhage. Results. All four patients underwent successful RFA without any intraprocedural complications. There has been no haemorrhage, or new renal specific symptom, during a minimum 48-month period, and normal renal function has been normal. On follow-up radiological imaging, the tumors have become fattier with involution of the soft-tissue elements (soft tissue-to-total tumor ratio decreased mean [range] of 0.26 [0.14-0.48] to 0.17 [0.04-0.34] U; p = 0.04 [paired Student t test]). Further evidence of treatment effect was the development of a capsule around the ablation zone, but there was no change in overall tumor volume (mean [range] 1,120 [118-2,845] to 1150 [90-3,013] ml; p = 1 [paired Student t test]). Conclusion. RFA of large AMLs is technically feasible using saline-infused electrodes. The soft-tissue elements decreased in volume; the tumors become fattier; and there has been no renal haemorrhage during a 48-month period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion of Preprocedural CTA with Real-time Fluoroscopy to Guide Proper Hepatic Artery Catheterization During Transarterial Chemoembolization of Hepatocellular Carcinoma: A Feasibility Study

To assess feasibility of proper hepatic artery catheterization using a 3D model obtained from preprocedural computed tomographic angiography (CTA), fused with real-time fluoroscopy, during transarterial chemoembolization of hepatocellular carcinoma. Twenty consecutive cirrhotic patients with hepatocellular carcinoma undergoing transarterial chemoembolization were prospectively enrolled onto the study. The early arterial phase axial images of the preprocedural CTA were postprocessed on an independent workstation connected to the angiographic system (Innova 4100; GE Healthcare, Milwaukee, WI), obtaining a 3D volume rendering image (VR) that included abdominal aorta, splanchnic arteries, and first and second lumbar vertebrae. The VR image was manually registered to the real-time X-ray fluoroscopy, with the lumbar spine used as the reference. The VR image was then used as guidance to selectively catheterize the proper hepatic artery. The procedure was considered successful when performed with no need for intraarterial contrast injections or angiographic acquisitions. The procedure was successful in 19 (95 %) of 20 patients. In one patient, celiac trunk angiography was required for the presence of a significant ostial stenosis that was underestimated at computed tomography. Time for image reconstruction and registration was <10 min in all cases. The use of preprocedural CTA model with fluoroscopy enables confident and direct catheterization of the proper hepatic artery with no need for preliminary celiac trunk angiography, thus reducing radiation exposure and contrast media administration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hyaluronic Acid Gel Injection to Prevent Thermal Injury of Adjacent Gastrointestinal Tract during Percutaneous Liver Radiofrequency Ablation

This study evaluated the safety, feasibility, and clinical utility of hyaluronic acid gel injection to separate the gastrointestinal tract from the tumor during liver radiofrequency ablation (RFA). Eleven patients with liver tumors measuring 0.9-3.5 cm (mean {+-} standard deviation, 2.1 {+-} 0.8 cm) that were adjacent to the gastrointestinal tracts received RFA after the mixture of hyaluronic acid gel and contrast material (volume, 26.4 {+-} 14.5 mL; range, 10-60 mL) was injected between the tumor and the gastrointestinal tract under computed tomographic-fluoroscopic guidance. Each tumor was separated from the gastrointestinal tract by 1.0-1.5 cm (distance, 1.2 {+-} 0.2 cm) after injection of hyaluronic acid gel, and subsequent RFA was performed without any complications in all patients. Although tumor enhancement disappeared in all patients, local tumor progression was found in a patient (9.1 %, 1 of 11) during the follow-up of 5.5 {+-} 3.2 months (range, 0.4-9.9 months). In conclusion, hyaluronic acid gel injection is a safe and useful technique to avoid thermal injury of the adjacent gastrointestinal tract during liver RFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-guided Periarterial Ethanol Injection for Renal Sympathetic Denervation: A Feasibility Study in Pigs

Purpose. To evaluate the feasibility and efficacy of image-guided periarterial ethanol injection as an alternative to transluminal radiofrequency ablation. Methods. Unilateral renal periarterial ethanol injection was performed under general anesthesia in 6 pigs with the contralateral kidney serving as control. All interventions were performed in an open 1.0 T MRI system under real-time multiplanar guidance. The injected volume was 5 ml (95 % ethanol labelled marked MR contrast medium) in 2 pigs and 10 ml in 4 pigs. Four weeks after treatment, the pigs underwent MRI including MRA and were killed. Norepinephrine (NE) concentration in the renal parenchyma served as a surrogate parameter to analyze the efficacy of sympathetic denervation. In addition, the renal artery and sympathetic nerves were examined histologically to identify evidence of vascular and neural injury. Results. In pigs treated with 10 ml ethanol, treatment resulted in neural degeneration. We found a significant reduction of NE concentration in the kidney parenchyma of 53 % (p < 0.02) compared with the untreated contralateral kidney. In pigs treated with 5 ml ethanol, no significant changes in histology or NE were observed. There was no evidence of renal arterial stenosis in MRI, macroscopy or histology in any pig. Conclusion. MR-guided periarterial ethanol injection was feasible and efficient for renal sympathetic denervation in a swine model. This technique may be a promising alternative to the catheter-based approach in the treatment of resistant arterial hypertension.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided High-Intensity Focused Ultrasound: Current Status of an Emerging Technology

The concept of ideal tumor surgery is to remove the neoplastic tissue without damaging adjacent normal structures. High-intensity focused ultrasound (HIFU) was developed in the 1940s as a viable thermal tissue ablation approach. In clinical practice, HIFU has been applied to treat a variety of solid benign and malignant lesions, including pancreas, liver, prostate, and breast carcinomas, soft tissue sarcomas, and uterine fibroids. More recently, magnetic resonance guidance has been applied for treatment monitoring during focused ultrasound procedures (magnetic resonance-guided focused ultrasound, MRgFUS). Intraoperative magnetic resonance imaging provides the best possible tumor extension and dynamic control of energy deposition using real-time magnetic resonance imaging thermometry. We introduce the fundamental principles and clinical indications of the MRgFUS technique; we also report different treatment options and personal outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Preclose Technique in Percutaneous Endovascular Aortic Repair: A Systematic Literature Review and Meta-analysis

Purpose. To establish the efficacy and safety of the preclose technique in total percutaneous endovascular aortic repair (PEVAR).MethodsA systematic literature search of Medline database was conducted for series on PEVAR published between January 1999 and January 2012.ResultsThirty-six articles comprising 2,257 patients and 3,606 arterial accesses were included. Anatomical criteria used to exclude patients from undergoing PEVAR were not uniform across all series. The technical success rate was 94 % per arterial access. Failure was unilateral in the majority (93 %) of the 133 failed PEVAR cases. The groin complication rate in PEVAR was 3.6 %; a minority (1.6 %) of these groin complications required open surgery. The groin complication rate in failed PEVAR cases converted to groin cutdown was 6.1 %. A significantly higher technical success rate was achieved when arterial access was performed via ultrasound guidance. Technical failure rate was significantly higher with larger sheath size ({>=}20F). Conclusion. The preclose technique in PEVAR has a high technical success rate and a low groin complication rate. Technical success tends to increase with ultrasound-guided arterial access and decrease with larger access. When failure occurs, it is unilateral in the majority of cases, and conversion to surgical cutdown does not appear to increase the operative risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metallic Stents for Tracheobronchial Pathology Treatment

Purpose: To present the 7-year experience of the treatment of benign and malignant tracheobronchial stenoses using metallic stents. Patients and Methods: One hundred twenty-three stents were inserted in 86 patients (74 benign and 12 malignant stenoses). Ninety-seven stents were placed in the trachea and 26 in the bronchi. The procedures were performed under fluoroscopic and flexible bronchoscopic guidance with the patient under light sedation. In cases of severe stenotic lesions or obstructions, laser resection was performed before stent placement. Clinical and functional pulmonary data were recorded before and 3 months after the procedure. Follow-up involved clinical data and radiographic techniques at 48 h and at 1-, 3-, 6-, and 12-month intervals. Results: The technical success was 100 %. Dyspnea disappearance, forced expiratory volume in the first second, and pulmonary functional data improvement was observed in all patients (p < 0.001). Complications were detected in 23 patients (26.7 %). Mean follow-up time was 6.3 {+-} 1.2 months in patients with malignant lesions and 76.2 {+-} 2.3 months patients with in benign lesions. By the end of the study, 100 % of patients with malignant pathology and 6.7 % of patients with benign lesions had died. Conclusion: Endoluminal treatment of tracheobronchial stenosis with metallic stents is a therapeutic alternative in patients who are poor candidates for surgery. In unresectable malignant lesions, the benefit of metallic stenting is unquestionable. In benign lesions, the results are satisfactory, but sometimes other interventions are required to treat complications. New stent technology may improve these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT Guided Bone Biopsy Using a Battery Powered Intraosseous Device

Purpose: To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. Methods: Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacare, Shavano Park, TX, USA). Data of the 12 were compared to a historic cohort in whom the specimen were acquired using the classic Jamshidi Needle, as reference needle using manual force for biopsy. Results: Technical success was reached in 11 of 12 cases, indicated by central localisation of the needle within the target lesion. All specimen sampled were sufficient for histopathological workup. Compared to the historical cohort the time needed for biopsy decreased significantly from 13 {+-} 6 to 6 {+-} 4 min (P = 0.0001). Due to the shortened intervention time the radiation dose (CTDI) during CT-fluoroscopy was lowered significantly from 169 {+-} 87 to 111 {+-} 54 mGy Multiplication-Sign cm (P = 0.0001). Interventional radiologists were confident with the performance of the needle especially when using in sclerotic or osteoblastic lesions. Conclusion: The OBM is an attractive support for CT-fluoroscopy guided bone biopsy which is safe tool and compared to the classical approach using the Jamshidi needle leading to significantly reduced intervention time and radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of High-Frequency Jet Ventilation for Percutaneous Tumor Ablation

Purpose: To report feasibility and potential benefits of high-frequency jet ventilation (HFJV) in tumor ablations techniques in liver, kidney, and lung lesions. Methods: This prospective study included 51 patients (14 women, mean age 66 years) bearing 66 tumors (56 hepatic, 5 pulmonary, 5 renal tumors) with a median size of 16 ± 8.7 mm, referred for tumor ablation in an intention-to-treat fashion before preoperative anesthesiology visit. Cancellation and complications of HFJV were prospectively recorded. Anesthesia and procedure duration, as well as mean CO{sub 2} capnea, were recorded. When computed tomography guidance was used, 3D spacial coordinates of an anatomical target <2 mm in diameter on 8 slabs of 4 slices of 3.75-mm slice thickness were registered. Results: HFJV was used in 41 of 51 patients. Of the ten patients who were not candidate for HFJV, two patients had contraindication to HFJV (severe COPD), three had lesions invisible under HFJV requiring deep inspiration apnea for tumor targeting, and five patients could not have HFJV because of unavailability of a trained anesthetic team. No specific complication or hypercapnia related to HFJV were observed despite a mean anesthetic duration of 2 h and ventilation performed in procubitus (n = 4) or lateral decubitus (n = 6). Measured internal target movement was 0.3 mm in x- and y-axis and below the slice thickness of 3.75 mm in the z-axis in 11 patients. Conclusions: HFJV is feasible in 80 % of patients allowing for near immobility of internal organs during liver, kidney, and lung tumor ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study

Purpose: Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. Methods: Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPE{sub CBCT}) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPE{sub CBCT-CT} from fused datasets. Image coregistration was evaluated using fiducial registration error (FRE{sub CBCT-CT}) and target registration error (TRE{sub CBCT-CT}). Results: Positioning accuracies in lateral directions pertaining to CBCT (TPE{sub CBCT} = 2.1 {+-} 1.0 mm) were found to be better to those achieved from previous study using CT (TPE{sub CT} = 2.3 {+-} 1.3 mm). Image coregistration error was 0.3 {+-} 0.1 mm, resulting in an average TRE of 2.1 {+-} 0.7 mm (N = 5 targets) and average Euclidean TPE{sub CBCT-CT} of 3.1 {+-} 1.3 mm. Conclusions: Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cholecystokinin-Assisted Hydrodissection of the Gallbladder Fossa during FDG PET/CT-guided Liver Ablation

A 68-year-old female with colorectal cancer developed a metachronous isolated fluorodeoxyglucose-avid (FDG-avid) segment 5/6 gallbladder fossa hepatic lesion and was referred for percutaneous ablation. Pre-procedure computed tomography (CT) images demonstrated a distended gallbladder abutting the segment 5/6 hepatic metastasis. In order to perform ablation with clear margins and avoid direct puncture and aspiration of the gallbladder, cholecystokinin was administered intravenously to stimulate gallbladder contraction before hydrodissection. Subsequently, the lesion was ablated successfully with sufficient margins, of greater than 1.0 cm, using microwave with ultrasound and FDG PET/CT guidance. The patient tolerated the procedure very well and was discharged home the next day.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Chronological Effects of Irreversible Electroporation on Hilar Bile Ducts in a Porcine Model

Purpose: To evaluate the chronological effects of irreversible electroporation (IRE) on large hilar bile ducts in an in vivo porcine model correlated with computed tomography (CT) cholangiography and histopathology. Materials and Methods: Twelve IRE zones were made along hilar bile ducts intraoperatively under ultrasound (US)-guidance in 11 pigs. Paired electrodes were placed either on opposing sides of the bile duct (straddle [STR]) or both on one side of the bile duct (one-sided [OSD]). The shortest electrode-to-duct distance was classified as periductal (≤2 mm) or nonperiductal (>2 mm). CT cholangiography and laboratory tests were performed before IRE and again at 2 days, 4 weeks, and 8 weeks after IRE. Degree of bile duct injury were graded as follows: grade 0 = no narrowing; grade 1 = ≤50 % duct narrowing; grade 2 = >50 % narrowing without proximal duct dilatation; grade 3 = grade 2 with proximal duct dilatation; and grade 4 = grade 3 with enzyme elevation. Pigs were selected for killing and histopathology at 2 days, 4, and 8 weeks. Results: Nonperiductal electrode placement produced no long-term strictures in 5 of 5 ducts. Periductal electrode placement produced mild narrowing in 6 of 7 ducts: 5 grade 1 and 1 grade 2. None showed increased enzymes. There was no significant difference between STR versus OSD electrode placement. Histopathology showed minor but relatively greater ductal mural changes in narrowed ducts. Conclusion: In the larger hilar ducts, long-term patency and mural integrity appear resistant to IRE damage with the energy deposition used, especially if the electrode is not immediately periductal in position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-guided Irreversible Electroporation in an Acute Porcine Liver Model: Effect of Previous Transarterial Iodized Oil Tissue Marking on Technical Parameters, 3D Computed Tomographic Rendering of the Electroporation Zone, and Histopathology

PurposeTo evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance.MethodsAfter Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann–Whitney test. Histopathological differences were assessed.ResultsMean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm{sup 3}, and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm{sup 3}, and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone.ConclusionThere is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗