Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRATINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Single-shot, phase-diversity phase retrieval for high-energy beam focal-spot diagnostics

A single-shot, phase-diversity phase-retrieval method is demonstrated for directly characterizing the on-target focal spot at kilojoule energy in the OMEGA 60-beam laser. A 2D holographic grating that introduces diversity focal spots is installed in an existing on-target focal-spot diagnostic to obtain a single-shot diversity focal-spot image. A nonlinear optimization phase-retrieval algorithm with four diversity focal spots is employed to determine modal coefficients for the incident wavefront. The agreement between the measured and calculated focal spots is excellent. Furthermore, this approach can be easily adapted for other high-energy focal-spot diagnostics.

47 OTHER INSTRUMENTATION↗

Simple strategy for the simulation of axially symmetric large-area metasurfaces

Metalenses are composed of nanostructures for focusing light and have been widely explored in many exciting applications. However, their expanding dimensions pose simulation challenges. We propose a method to simulate metalenses in a timely manner using vectorial wave and ray tracing models. We sample the metalens’s radial phase gradient and locally approximate the phase profile by a linear phase response. Each sampling point is modeled as a binary blazed grating, employing the chosen nanostructure, to build a transfer function set. The metalens transmission or reflection is then obtained by applying the corresponding transfer function to the incoming field on the regions surrounding each sampling point. Fourier optics is used to calculate the scattered fields under arbitrary illumination for the vectorial wave method, and a Monte Carlo algorithm is used in the ray tracing formalism. We validated our method against finite-difference time domain simulations at 632 nm, and we were able to simulate metalenses larger than 3000 wavelengths in diameter on a personal computer.

Martins, Augusto (ORCID:0000000295546481)↗

Bendable disordered metamaterials for broadband terahertz invisibility

We experimentally demonstrate a bendable cloaking structure composed of obliquely stacked planar metallic shells that individually enclose the objects to be hidden. The ensemble of shells acts as a disordered oblique grating capable of bending along a curved structure and exhibits broadband invisibility from 0.2 to 1.0 THz. Hiding cloaked objects sized hundreds of microns could prevent the detection of certain powders that are sensitive to terahertz waves; such a cloaking structure can also be considered as a shape-changing passageway that transfers the electromagnetic waves without interfering with them. Our approach provides a unique way to achieve broadband electromagnetic invisibility.

36 MATERIALS SCIENCE↗

Ultranarrow bandwidth pulses from a regeneratively mode-locked fiber laser

We report on the generation of transform-limited nanosecond pulse with an ultranarrow bandwidth from a regeneratively mode-locked erbium-doped fiber laser. A narrow bandwidth fiber Bragg grating is combined with a bulk amplitude electro-optic modulator to shape pulse evolution inside a ring cavity, and regenerative mode locking is applied to produce a stationary shape of pulses in the nanosecond regime (2.05 ns in duration). Spectral characterization via high bandwidth optoelectronic devices shows that optical pulses have an ultranarrow bandwidth of 220 MHz. Numerical simulation reveals that the shape of the narrow spectral filter has a strong effect on the duration and bandwidth of output pulses.

43 PARTICLE ACCELERATORS↗

Design and characterization of “flow-cell” integrated-flow active cooling for high-average-power ceramic optics

We used COMSOL Multiphysics to design a prototype actively cooled “flow-cell” substrate targeted at high-average-power applications, fabricated the prototype from cordierite ceramic, and tested the substrate under load in our thermal loading test stand. Sub-aperture testing revealed average-power handling up to 3.88-W/cm 2 absorbed power density, in excellent agreement with model predictions. Gratings fabricated on 2-in.-diam cordierite coupons were subjected to laser-damage testing and showed a damage threshold of 250 mJ/cm 2 .

47 OTHER INSTRUMENTATION↗

Hard x-ray – optical four-wave mixing using a split-and-delay line

New, hard x-ray free electron lasers (FEL) produce intense femtosecond-to-attosecond pulses at angstrom wavelengths, giving access to the fundamental spatial and temporal scales of matter. These revolutionary light sources open the door to applying the suite of nonlinear, optical spectroscopy methods at hard x-ray photon energies. Nonlinear spectroscopy with hard x-rays can allow for measuring the coherence properties of short wavelength excitations with atomic specificity and for understanding how high energy excitations couple to other degrees of freedom in atomic, molecular or condensed-phase systems. As a step in this direction, here we present hard x-ray, optical four-wave mixing (4WM) measurements done at 9.8 keV at the split-and-delay line at the x-ray correlation spectroscopy (XCS) hutch of the Linac Coherent Light Source (LCLS). In this work, we create an x-ray transient grating (TG) from a pair of crossing x-ray beams and diffract optical laser pulses at 400 nm from the TG. The key technical advance here is being able to independently vary the delays of the x-ray pulses. Measurements were made in 3 different solid samples: bismuth germinate (BGO), zinc oxide (ZnO) and yttrium aluminum garnet (YAG). The resulting phase-matched, 4WM signal is measured in two different ways: by varying the x-ray, x-ray pulse delay which can reveal both material and light source coherence properties and also by varying the optical laser delay with respect to the x-ray TG to study how the x-ray excitation couples to the optical properties. Although no coherent 4WM signal was seen in these measurements, the absence of this signal gives important information on experimental requirements for detecting this in future work. Also, our laser-delay scans, although not a new measurement, were applied to different materials than in past work and reveal new examples x-ray induced lattice dynamics in solids. This work represents a key step towards extending nonlinear optics and time-resolved spectroscopy into the hard x-ray regime.

47 OTHER INSTRUMENTATION↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-shot measurements of shaped XUV FEL pulses with frequency-resolved optical gating

The ability to control the amplitude and phase of extreme ultraviolet (XUV) and X-ray free-electron laser (FEL) pulses can allow for the extension of optical techniques, such as multidimensional spectroscopy or coherent control, to higher photon energies, for probing and controlling core electronic transitions. However, this requires the ability to make single-shot, and complete, electric field measurements of potentially complex FEL pulses, in order to develop, and verify, pulse shaping strategies. Here, we present direct, single-shot measurements of XUV pulses generated under special operating configurations for producing specific pulse shapes from a laser-seeded XUV FEL. To do this, we built upon our past work using transient grating (TG) cross correlation frequency-resolved optical gating (FROG), where an optical reference pulse is diffracted from an XUV TG produced by a pair of interfering FEL pulses. The resulting nonlinear signal versus frequency and delay, i.e., the FROG trace, contains the electric field of the FEL pulse. The FEL pulse electric field is reconstructed from the FROG trace using a phase retrieval algorithm. Here we confirmed three different pulse shaping strategies for generating chirped, double and multiple FEL pulses by tuning the seed laser and FEL parameters and measuring the resulting shaped FEL pulses with TG XFROG. This work paves the way for generating on-demand pulse shapes with a seeded FEL by improving the characterization of FEL pulses, for transform-limited to more complex shapes.

Elverson, Francesca↗

High-temperature all-fiber non-destructive multi-parameter sensing system with consistent performance

A high-temperature all-fiber non-destructive multi-parameter sensing system is developed. The system can operate consistently in a wide range of temperature changes by specially designed active signal generation and detection units. It is capable of monitoring temperature up to 600°C and cracks on metal pipes with an acoustic wave generation unit and an acoustic detection unit. A gold-coated multi-mode fiber is used to deliver a laser pulse for acoustic excitation while minimizing parasitic acoustic signals at high temperature. An in-fiber Fabry–Perot fiber Bragg grating (FP-FBG) is fabricated in another single-mode fiber and bonded to the test object for acoustic detection. The FP-FBG avoids strain redistribution inside the bonder at high temperature to ensure consistent operation. The feasibility of the system for temperature monitoring and crack detection in real-world applications is also demonstrated on an industry-standard P91 pipe.

He, Jiaji (ORCID:0000000165661887)↗

Design of an amplitude-splitting hard x-ray delay line with subnanoradian stability

We propose the design and analysis of a hard x-ray split-delay optical arrangement that combines diffractive and crystal optics. Transmission gratings are employed to achieve the much-desired amplitude splitting and recombination of the beam. Asymmetric channel-cut crystals are utilized to tune the relative delay time. The use of a dispersion-compensation arrangement of the crystals allows the system to achieve subnanoradian pointing stability during a delay scan. It further minimizes wavefront distortion and preserves the pulse front and pulse duration. We analyze the performance of a prototype design that can cover a delay time range of 15 ps with a sub-20 fs time resolution at 10 keV. We anticipate that this system can fully satisfy the very demanding stability requirements for performing split-pulse x-ray photon correlation spectroscopy measurements for the investigation of fast atomic scale dynamics in complex disordered matter.

47 OTHER INSTRUMENTATION↗

Mid-infrared frequency doubling using strip-loaded silicon nitride on epitaxial barium titanate thin film waveguides

Broadband mid-infrared (mid-IR) frequency doubling was demonstrated using nonlinear barium titanate (BTO) thin films. The device has a strip-loaded waveguide structure consisting of top silicon nitride (SiN) strips and an underneath BTO guiding layer. The epitaxial BTO was deposited on a strontium titanate (STO) substrate by pulsed-laser deposition. Through a SiN grating coupler, the pumping mid-IR light at wavelength &#x03BB;<!-- λ --> = 3.30 &#x2212;<!-- - --> 3.45 &#x00B5;<!-- µ --> m was coupled into the nonlinear BTO layer, where the spectrum of the near-infrared (NIR) second-harmonic generation was characterized. The developed BTO waveguides provide a platform for mid-IR nonlinear integrated photonics and on-chip quantum optics.

42 ENGINEERING↗

Ultra-high extinction ratio polarization beam splitter with extreme skin-depth waveguide

In this Letter, we present a high extinction ratio and compact on-chip polarization beam splitter (PBS), based on an extreme skin-depth (eskid) waveguide. Subwavelength-scale gratings form an effectively anisotropic metamaterial cladding and introduce a large birefringence. The anisotropic dielectric perturbation of the metamaterial cladding suppresses the TE polarization extinction via exceptional coupling, while the large birefringence efficiently cross-couples the TM mode, thus reducing the coupling length. We demonstrated the eskid-PBS on a silicon-on-insulator platform and achieved an ultra-high extinction ratio PBS ( ≈ <#comment/> 60 d B for TE and ≈ <#comment/> 48 d B for TM) with a compact coupling length ( ≈ <#comment/> 14.5 µ <#comment/> m ). The insertion loss is also negligible ( < <#comment/> 0.6 d B ). The bandwidth is > <#comment/> 80 (30) nm for the TE (TM) extinction ratio > <#comment/> 20 d B . Our ultra-high extinction ratio PBS is crucial in implementing efficient polarization diversity circuits, especially where a high degree of polarization distinguishability is necessary, such as photonic quantum information processing.

Ahmed, Syed Z.↗

Megawatt pulses from an all-fiber and self-starting femtosecond oscillator

Mamyshev oscillators produce high-performance pulses, but technical and practical issues render them unsuitable for widespread use. Here we present a Mamyshev oscillator with several key design features that enable self-starting operation and unprecedented performance and simplicity from an all-fiber laser. The laser generates 110 nJ pulses that compress to 40 fs and 80 nJ with a grating pair. The pulse energy and duration are both the best achieved by a femtosecond all-fiber laser to date, to our knowledge, and the resulting peak power of 1.5 MW is 20 times higher than that of prior all-fiber, self-starting lasers. Finally, the simplicity of the design, ease of use, and pulse performance make this laser an attractive tool for practical applications.

47 OTHER INSTRUMENTATION↗

Resolved rotation–vibration non-equilibrium with rotational VIPA-CARS

Simultaneous rotational and vibrational temperatures are measured in an N 2 plasma with rotational coherent anti-Stokes Raman scattering (CARS) resolved with a virtually imaged phased array (VIPA)-based spectrometer. A VIPA spectrally separates rotational transitions for each vibrational state, allowing vibrational populations to be directly measured. VIPA-CARS is shown to provide more accurate measurements of non-equilibrium temperatures than grating-resolved rotational CARS. The general characteristics, limitations, and potential uses of VIPA-CARS are discussed.

Steinmetz, S. A. (ORCID:0000000311014662)↗

Boosting SNR of cascaded FBGs in a sapphire fiber through a rapid heat treatment

This Letter reports the performance of femtosecond (fs) laser-written distributed fiber Bragg gratings (FBGs) under high-temperature conditions up to 1600°C and explores the impact of rapid heat treatment on signal-to-noise ratio (SNR) enhancement. FBGs are essential for reliable optical sensing in extreme temperature environments. Comprehensive tests demonstrate the remarkable performance and resilience of FBGs at temperatures up to 1600°C, confirming their suitability for deployment in such conditions. Here, the study also reveals significant fringe visibility improvements of up to ∼10 dB on a 1-m-long sapphire optical fiber through rapid heat treatment, representing a first-time achievement to the best of our knowledge. These enhancements are vital for improving the SNR and overall performance of optical fiber systems in extreme temperatures. Furthermore, the research attains long-term stability for the cascaded FBGs over a 24-hr period at 1600°C. This research expands our understanding of the FBG behavior in high-temperature environments and opens avenues for developing robust optical fiber systems for energy, aerospace, oil and gas, and high-temperature distributed sensing applications.

47 OTHER INSTRUMENTATION↗

Demonstration of a 1 TW peak power, joule-level ultrashort Tm:YLF laser

Here we report on the demonstration of a diode-pumped, Tm:YLF-based, chirped pulse amplification laser system operating at λ ≈ 1.9 µm that produces amplified pulse energies exceeding 1.5 J using a single 8-pass power amplifier. The amplified pulses are subsequently compressed to sub-300 fs durations by a diffraction grating pair, producing record >1 TW peak power pulses. To the best of our knowledge, this is the highest peak power demonstrated for any solid-state, near-2 µm laser architecture and illustrates the potential of Tm:YLF for the next generation of high-power, diode-pumped ultrashort lasers.

47 OTHER INSTRUMENTATION↗

Three-beam hybrid fs/ps coherent anti-Stokes Raman scattering of rotation–vibration non-equilibrium

In this work, we demonstrate time-resolved rotational and vibrational temperature measurements to probe plasma non-equilibrium through a simple three-beam hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system. A single pump/Stokes pair is employed to generate both the pure-rotational and ro-vibrational Raman coherence. A novel phase-matching scheme, to our knowledge, is employed to spatially overlap the two CARS signals, simplifying the optical design and allowing signal selection by tuning a single spectrometer grating. Measurements were performed near the electrodes in a N 2 DC glow discharge. Both the rotational temperature and the vibrational populations up to $v$ = 8 were calculated from the separately measured single-shot pure-rotational and ro-vibrational CARS spectra. Strong rotation–vibration non-equilibrium was observed at both electrodes, with the cathode showing higher vibrational and rotational temperatures. In addition, non-Boltzmann behaviors were observed at both electrodes. This simplified approach enables measurements of rotational and vibrational temperatures with high spatial resolution in non-equilibrium flows.

42 ENGINEERING↗

AlSb as a material for high index contrast nanophotonics

High contrast materials, i.e., materials with a high refractive index and low optical loss, are of wide interest for nanophotonics and metasurface designs at optical and near infrared wavelengths. We explore aluminum antimonide (AlSb) as a high contrast nanophotonic material, using the design of high contrast gratings (HCGs) for low loss dielectric mirrors as an example. The high index of refraction and low absorption coefficient of AlSb in the visible wavelength range enable designs of HCGs that can be effectively optimized to form mirrors with 93.5% reflectivity at red visible wavelengths. We detail a co-sputtering synthesis method for AlSb films, and achieve our target high index of refraction of 3.5 for 635 nm light. We also find that the high sensitivity of AlSb oxidation requires specific handling procedures in developing deposition processes to yield a near zero absorption coefficient.

Bauser, Haley C.↗