Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

The Hubble Space Telescope quasar absorption line key project. v. redshift evolution of lyman limit absorption in the spectra of a large sample of quasars

Using a sample of 119 QSOs, containing objects we have selected having previously available high quality ground-based and IUE spectral observations, together with Hubble Space Telescope (HST) observations of 26 QSOs from Bahcall et al. (1993, 1995) and Impey et al. (1995) and new optical observations of 41 objects by Steidel & Sargent (1995), we study the redshift evolution of Lyman limit absorption systems (LLSs; tau greater than 1.0) over the reshift range 0.32 less than or equal to z(sub LLS) less than or equal to 4.11. The HST observations significantly improve the determination of the low redshift (0.4 less than or equal to z(sub LLS) less than or equal to 1.4) distribution. We find the effect which may have been responsible for the apparent strong evolution at a(sub LLS) greater than or equal to 2.5 found by Lanzetta (1991), which led him to consider a broken, not single power law as a better description of the redshift distribution of LLSs. After removing objects which may bias our sample, leaving a total of 169 QSOs, we find the distribution is well described by a single power law, and obtain for the number density as a function of redshift the form N(z) = N(sub 0)(1 + z)(exp gamma) with gamma = 1.50 =/- 0.39 and N(sub 0) = 0.25(sup -0.10)(sub +0.17), consistent with a constant comoving density of absorbers in a Firedmann universe with q(sub 0) = 0 but indicating evolution if q(sub 0) = 1/2.

Stengler-Larrea, Erik A.↗

Heavy fermion behavior explained by bosons

Conventional heavy fermion (HF) theories require existence of massive fermions. We show that heavy fermion phenomena can also be simply explained by existence of bosons with moderate mass but temperature dependent concentration below the formation temperature T(sub B), which in turn is close to room temperature. The bosons B(++) are proposed to be in chemical equilibrium with a system of holes h(+): B(++) = h(+) + h(+). This equilibrium is governed by a boson breaking function f(T), which determines the decreasing boson density and the increasing fermion density with increasing temperature. Since HF-compounds are hybridized from minimum two elements, we assume in addition existence of another fermion component h(sub s)(+) with temperature independent density. This spectator component is thought to be the main agent in binding the bosons in analogy with electronic or muonic molecules. Using a linear boson breaking function we can explain temperature dependence of the giant linear specific heat coefficient gamma(T) coming essentially from bosons. The maxima in resistivity, Hall coefficient, and susceptibility are explained by boson localization effects due to the Wigner crystallization. The antiferromagnetic transitions in turn are explained by similar localization of the pairing fermion system when their density n(sub h)(T(sub FL)) becomes lower than n(sub WC), the critical density of Wigner crystallization. The model applies irrespective whether a compound is superconducting or not. The same model explains the occurrence of low temperature antiferromagnetism also in high-T(sub c) superconductors. The double transition in UPt3 is proposed to be due to the transition of the pairing fermion liquid from spin polarized to unpolarized state.

Kallio, A.↗

Computation of Domain-Averaged Shortwave Irradiance by a One-Dimensional Algorithm Incorporating Correlations between Optical Thickness and Direct Incident Radiation

A one-dimensional radiative transfer algorithm that accounts for correlations between the optical thickness and the incident direct solar radiation is developed to compute the domain-averaged shortwave irradiance profile. It divides the direct irradiance into four components and treats the direct irradiance in two separate, clear and cloudy columns to account for the fact that clouds attenuate the direct irradiance more than clear-sky. The horizontal inhomogeneity of clouds in the cloudy column is treated by the gamma weighted two-stream approximation, which assumes that the optical thickness of clouds follows a gamma distribution. The algorithm inputs the cloud fraction, cumulative cloud fraction as a function of height, and a parameter expressing the shape of the probability density function of the cloud optical thickness distribution in addition to inputs required for a two-stream radiative transfer model. These cloud property inputs can be obtained using ground- and satellite-based instruments. Therefore, the algorithm can treat realistic cloud overlap features and horizontal inhomogeneity of clouds in a framework of one- dimensional radiative transfer. Heating rates computed by the algorithm using cloud fields generated by cloud resolving models agree with those computed with a Monte Carlo model. If optical properties in computational layers that divide a vertically extensive cloud are correlated, the irradiance profile computed by the algorithm further improves.

Kato, S.↗

Dithiomethylether As a Ligand in the Hydrogenase H-Cluster

An X-ray crystallographic refinement of the H-cluster of [FeFe]-hydrogenase from Clostridium pasteurianum has been carried out to close-to atomic resolution and is the highest resolution [FeFe]-hydrogenase presented to date. The 1.39 {angstrom}, anisotropically refined [FeFe]-hydrogenase structure provides a basis for examining the outstanding issue of the composition of the unique nonprotein dithiolate ligand of the H-cluster. In addition to influencing the electronic structure of the H-cluster, the composition of the ligand has mechanistic implications due to the potential of the bridge-head {gamma}-group participating in proton transfer during catalysis. In this work, sequential density functional theory optimizations of the dithiolate ligand embedded in a 3.5-3.9 {angstrom} protein environment provide an unbiased approach to examining the most likely composition of the ligand. Structural, conformational, and energetic considerations indicate a preference for dithiomethylether as an H-cluster ligand and strongly disfavor the dithiomethylammonium as a catalytic base for hydrogen production.

08 HYDROGEN↗

An Advanced ISOCS In Situ Gamma Spectrometry Services Tool to Reduce Uncertainties in Waste Characterization Projects - 16311

Canberra's In Situ Object Counting System (ISOCS) is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function. It avoids the need for radioisotope standards which can be costly and prohibitively difficult to produce. Uncertainties in the sample - detector geometry lead to uncertainties in the calibrations. Canberra's ISOCS Uncertainty Estimator (IUE) tool offers an automated means of accommodating known model geometry uncertainties, with calculation of robust defensible calibration uncertainties. However these uncertainties may be large leading to potential over-estimation of under-estimation of activity. This can be equated directly to waste disposal costs if one is using ISOCS for waste sentencing to classify wastes as (for example) Transuranic Waste (TRU) or Low Level Waste (LLW). An Advanced ISOCS in-situ Gamma Spectrometry (AIGS) services tool has been developed to reduce the uncertainties. This system is based on generating and comparing geometry models that yield Figures of Merit (FoM) indicative of improved consistency between modelled data and available diverse measurement data. This paper describes the development and features of AIGS, focusing on recent testing with radioisotope sources in a 200 litre drum filled with a simulated waste matrix. The results demonstrate a significant advantage for Am-241 where uncertainties can otherwise amount to a factor of 2 or more. We show how our specialist teams can develop procedures for deployment of standard ISOCS hardware, adapting measurement geometries and procedures through careful planning, to provide data that can be used to greatly reduce the uncertainties in the measured activities. Lastly, we comment on the range of potential applications for this new technique and the wider benefits for the decommissioning industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Classical strongly coupled quark-gluon plasma. V. Structure factors

We show that the classical and strongly coupled quark-gluon plasma is characterized by a multiple of structure factors that obey generalized Orstein-Zernicke equations. We use the canonical partition function and its associated density functional to derive analytical equations for the density and charge monopole structure factors for arbitrary values of {Gamma}=V/K, the ratio of the mean potential to the Coulomb energy. The results are compared with SU(2) molecular dynamics simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fermi Large Area Telescope Observations of the Supernova Remnant GS.7-0.1

We present a detailed analysis of the GeV gamma-ray emission toward the supernova remnant (SNR) G8.7-0.1 with the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope. An investigation of the relationship among G8.7-0.l and the TeV unidentified source HESS J1804-216 provides us with an important clue on diffusion process of cosmic rays if particle acceleration operates in the SNR. The GeV gamma-ray emission is extended with most of the emission in positional coincidence with the SNR G8.7-0.l and a lesser part located outside the western boundary of G8.7-0.l. The region of the gamma-ray emission overlaps spatially-connected molecular clouds, implying a physical connection for the gamma-ray structure. The total gamma-ray spectrum measured with LAT from 200 MeV-100 GeV can be described by a broken power-law function with a break of 2.4 +/- 0.6 (stat) +/- 1.2 (sys) GeV, and photon indices of 2.10 +/- 0.06 (stat) +/- 0.10 (sys) below the break and 2.70 +/- 0.12 (stat) +/- 0.l4 (sys) above the break. Given the spatial association among the gamma rays, the radio emission of G8.7-0.1, and the molecular clouds, the decay of 1IoS produced by particles accelerated in the SNR and hitting the molecular clouds naturally explains the GeV gamma-ray spectrum. We also find that the GeV morphology is not well represented by the TeV emission from HESS J1804-216 and that the spectrum in the GeV band is not consistent with the extrapolation of the TeV gamma-ray spectrum. The spectral index of the TeV emission is consistent with the particle spectral index predicted by a theory that assumes energy-dependent diffusion of particles accelerated in an SNR. We discuss the possibility that the TeV spectrum originates from the interaction of particles accelerated in G8.7-0.1 with molecular clouds, and we constrain the diffusion coefficient of the particles.

Ajello, M.↗

DETECTION OF A THERMAL SPECTRAL COMPONENT IN THE PROMPT EMISSION OF GRB 100724B

Observations of GRB 100724B with the Fermi Gamma-Ray Burst Monitor find that the spectrum is dominated by the typical Band functional form, which is usually taken to represent a non-thermal emission component, but also includes a statistically highly significant thermal spectral contribution. The simultaneous observation of the thermal and non-thermal components allows us to confidently identify the two emission components. The fact that these seem to vary independently favors the idea that the thermal component is of photospheric origin while the dominant non-thermal emission occurs at larger radii. Our results imply either a very high efficiency for the non-thermal process or a very small size of the region at the base of the flow, both quite challenging for the standard fireball model. These problems are resolved if the jet is initially highly magnetized and has a substantial Poynting flux.

79 ASTRONOMY AND ASTROPHYSICS↗

A new method for focusing and imaging X-rays and gamma-rays with diffraction crystals

Bent diffraction crystals in which the intercrystalline-plane spacing is varied as a function of position in the crystal are used to focus monochromatic radiation from a point source or parallel beam down to a point image. Conversely, radiation from a point source can be focused into an outgoing parallel beam. The Bragg angle for diffraction of monochromatic radiation will now vary as a function of position in the crystal and this new degree of freedom is used to obtain focusing and imaging of the diffracted beam. This approach to focusing and imaging is applied to the design of a large-area, high resolution X-ray telescope that is also a high resolution monochromator with the unique feature that the width of the energy increment that is diffracted can be controlled and varied during the operation of the instrument. The field can be scanned with a wide energy increment and then switched to a narrow energy increment for the high resolution work. Both transmission and reflection type diffraction crystals can be used.

Smither, R. K.↗

Improved Gamma-and X-Ray Pinhole Camera

Electronic additions increase image quality. Digital image-processing equipment electronically performs functions of S1 and D2 improving resolution and adding capability for image storage and further processing. System useful in nuclear medicine or radioisotope imaging, tomography and nuclear industry.

Yin, L. I.↗

Small-scale density irregularities in the nightside Venus ionosphere - Comparison of theory and observations

The theory of the lower-hybrid-drift instability is compared with observations of plasma density irregularities. Marginal stability boundaries (gamma = 0) for the lower-hybrid-drift instability and the occurrence of small-scale density fluctuations are presented as a function of magnetic field B and density n. For plasma density gradient scale lengths in the range 2-10 km, 80-85 percent of the density fluctuations lie in the unstable B/n parameter regime (gamma greater than 0). Stability boundaries for the onset of instability at a wavelength for which the Pioneer Venus Orbiter could measure a Doppler-shifted frequency of 100 Hz are presented. The conditions on B and n for instability in this situation are more stringent than those for marginal stability, especially at low densities (n less than or equal to 5000/cu cm). In general, the instability is most likely to be active in regions of low beta: high magnetic field strength and low density, as found in ionospheric holes or troughs.

Huba, J. D.↗

SU-E-T-135: Dosimetric Properties of the OCTAVIUS Detector 1500

Purpose: In this study the dosimetric properties of the Octavius Detector 1500 array (PTW-Freiburg-Germany) are investigated. Methods: The chambers of the array, each with an entrance window of 4.4 × 4.4 cm{sup 2}, are arranged in a checkerboard pattern in a measurement area of 27 × 27 cm{sup 2} with a sampling frequency of 0.1 mm{sup −1} along each row which can be doubled by merging two measurements shifted by 5 mm. Linearity, stability and output factors were measured with either a Semiflex 31013 or 31010 as a reference detector. Output factors were additionally measured with a Diode 60012. The effective point of measurement was determined by comparing TPR curves of the array with Roos chamber 34001 measurements. The lateral dose response function of a single chamber was determined by comparison with a high resolution diode. An IMRT field verification was carried out with a merged OD1500 measurement. Results: The OD1500 was stable within ±0.15 %. Deviations in linearity did not exceed 1% from 5 to 1000 MU. The effective point of measurement was 8.2 mm below the surface. Deviations in output factors were below 0.77 % from 5 × 5 to 27 × 27 cm{sup 2}. As expected for the smallest field of 1 × 1 cm{sup 2}, the deviation from the diode was significant. The widths of the lateral dose response functions were σ{sup 6} = (2.07 ± 0.03) mm and σ{sup 15} = (2.09 ± 0.03) mm. Gamma Index passing rates for typical IMRT and VMAT plans were above 90 % compared to film and TPS calculations for a local 3 mm / 3 % criterion. Conclusion: The first measurements with the OD1500 array show the excellent applicability of the array for clinical dosimetry. The response of the array to the mean photon energy and dose per pulse are under investigation.

60 APPLIED LIFE SCIENCES↗

MODELING GAMMA-RAY BURST X-RAY FLARES WITHIN THE INTERNAL SHOCK MODEL

X-ray afterglow light curves have been collected for over 400 Swift gamma-ray bursts (GRBs) with nearly half of them having X-ray flares superimposed on the regular afterglow decay. Evidence suggests that gamma-ray prompt emission and X-ray flares share a common origin and that at least some flares can only be explained by long-lasting central engine activity. We have developed a shell model code to address the question of how X-ray flares are produced within the framework of the internal shock model. The shell model creates randomized GRB explosions from a central engine with multiple shells and follows those shells as they collide, merge, and spread, producing prompt emission and X-ray flares. We pay special attention to the time history of central engine activity, internal shocks, and observed flares, but do not calculate the shock dynamics and radiation processes in detail. Using the empirical E{sub p} -E{sub iso} (Amati) relation with an assumed Band function spectrum for each collision and an empirical flare temporal profile, we calculate the gamma-ray (Swift/BAT band) and X-ray (Swift/XRT band) lightcurves for arbitrary central engine activity and compare the model results with the observational data. We show that the observed X-ray flare phenomenology can be explained within the internal shock model. The number, width, and occurring time of flares are then used to diagnose the central engine activity, putting constraints on the energy, ejection time, width, and number of ejected shells. We find that the observed X-ray flare time history generally reflects the time history of the central engine, which reactivates multiple times after the prompt emission phase with progressively reduced energy. The same shell model predicts an external shock X-ray afterglow component, which has a shallow decay phase due to the initial pile-up of shells onto the blast wave. However, the predicted X-ray afterglow is too bright as compared with the observed flux level, unless epsilon{sub e} is as low as 10{sup -3}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time variations of an absorption feature in the spectrum of the gamma-ray burst on 1980 April 19

The photon number spectrum integrated over the impulsive part of the event is shown to fit a thermal bremsstrahlung function with a temperature of 330 + or - 70 keV at energies between 151 and 487 keV. At lower energies, the data points lie considerably below this function, indicating a broad absorption feature extending down to values less than or equal to 28 keV, the lowest energy measured. The upper energy of this absorption feature varies from 100 to 150 keV on a time scale less than or equal to 0.5 s. This event is interpreted as a typical gamma ray burst, even though it is still considered remotely possible that it is of solar origin. The spectral features, together with their variability, are interpreted in terms of electron interactions at the cyclotron resonance frequency in magnetic fields of 10 to the 12th - 10 to the 13th gauss close to the surface of a neutron star.

Dennis, B. R.↗

SU-E-T-121: Dosimetric Characterization of Gafchromic Film EBT3 Using Vidar DosimetryPro Advantage RED and EPSON Expression 10000XL Scanners

Purpose: The purpose of this paper is to characterize EBT3 using two types of scanner, analyzing the factors of influence of each dosimetry system. Methods: The film used in this study was GAFCHROMIC EBT3, the films were exposed at a dose range between 0Gy a 9Gy in a solid water phantom, SSD=100cm, 5cm depth and perpendicularly to the 6MV photon beam generated by a Novalis TX linear accelerator equipped with an HDMLC. A Farmer type ion chamber TN30013 (PTW) was used to determine the dose delivered to the film. The films were digitized with a scanner EPSON expression 10000XL and the VIDAR DosimetryPro Adventage RED. Software RIT113v6.1 was used for construction of the calibration curve and analysis. The film characteristics investigated were: response at different dose levels, sensitivity to orientation and side and resolution through the results of the spatial response function by analyzing a step pattern. Additionally, 20 IMRT treatment fields were measured with both scanner and compared with calculated dose using gamma index analysis (3%-3mm). Results: The OD obtained for dose level 2Gy in the orientation portrait of the film on the scanner EPSON is (0,222±0,19) and for Vidar RED (0,252±0,10) and landscape is for EPSON (0,211±0,25) and for Vidar RED (0,250±0,11) . The orientation dependence with respect to film side is about 0,09% for EPSON and about 0.03% for VIDAR. The spatial response function increase in response to the Gaussian function FWHM EPSON scanner (0.18mm) compared with VIDAR scanner function (less than 0.06mm) was observed. We analyzed 20 total plan dose distributions the number of pixels with gamma>1 (3%-3mm) was 0.7%±1.2 [0.1%; 2.82%] for EBT3-VIDAR y 2%±2.9 [0.2%; 3.5%] for EBT3-EPSON. Conclusion: VIDAR scanner shows better sensitivity. EBT3 film shows a different response between portrait and landscape orientation. Step pattern is better reproduce by VIDAR scanner.

07 ISOTOPE AND RADIATION SOURCES↗