Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fundamental Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Time-Resolved Hanbury Brown–Twiss Interferometry of On-Chip Biphoton Frequency Combs Using Vernier Phase Modulation

Biphoton frequency combs (BFCs) are promising quantum sources for large-scale and high-dimensional quantum information and networking systems. In this context, the spectral purity of individual frequency bins will be critical for realizing quantum networking protocols like teleportation and entanglement swapping. Measurement of the temporal autocorrelation function of the unheralded signal or idler photons comprising the BFC is a key tool for characterizing their spectral purity and in turn verifying the utility of the biphoton state for networking protocols. Yet the experimentally obtainable precision for measuring BFC correlation functions is often severely limited by detector jitter. The fine temporal features in the correlation function—not only of practical value in quantum information, but also of fundamental interest in the study of quantum optics—are lost as a result. We propose a scheme to circumvent this challenge through electro-optic phase modulation, experimentally demonstrating time-resolved Hanbury Brown–Twiss characterization of BFCs generated from an integrated 40.5-GHz Si 3 N 4 microring, up to a 3×3-dimensional two-qutrit Hilbert space. Through slight detuning of the electro-optic drive frequency from the comb’s free spectral range, our approach leverages Vernier principles to magnify temporal features, which would otherwise be averaged out by detector jitter. We demonstrate our approach under both continuous-wave and pulsed-pumping regimes, finding excellent agreement with theory. In conclusion, our method reveals not only the collective statistics of the contributing frequency bins but also their temporal shapes—features lost in standard fully integrated autocorrelation measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep Learning Parameterization of Vertical Wind Velocity Variability via Constrained Adversarial Training

Atmospheric models with typical resolution in the tenths of kilometers cannot resolve the dynamics of air parcel ascent, which varies on scales ranging from tens to hundreds of meters. Small-scale wind fluctuations are thus characterized by a subgrid distribution of vertical wind velocity W with standard deviation σ W . The parameterization of σ W is fundamental to the representation of aerosol–cloud interactions, yet it is poorly constrained. Using a novel deep learning technique, this work develops a new parameterization for σ W merging data from global storm-resolving model simulations, high-frequency retrievals of W , and climate reanalysis products. The parameterization reproduces the observed statistics of σ W and leverages learned physical relations from the model simulations to guide extrapolation beyond the observed domain. Incorporating observational data during the training phase was found to be critical for its performance. The parameterization can be applied online within large-scale atmospheric models, or offline using output from weather forecasting and reanalysis products.

54 ENVIRONMENTAL SCIENCES↗

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center↗

Prevention of Dual-Mode Excitation in 9-Cell Cavities for LCLSII-HE

Dual-Mode Excitation, also referred to as mode-mixing, is a superposition of two fundamental pi modes in an SRF cavity. In 9-cell TESLA cavities used for the LCLSII-HE project, the two modes that are commonly excited are the pi mode (1300.2 MHz), and the 7/9 pi mode (1297.8 MHz). During vertical cavity qualification testing, only the pi mode is driven by the RF system. However, at high gradients, emitted power at the frequency of the 7/9 pi mode grows despite the RF system only powering the pi mode. When this happens, the RF power measurement system is unable to differentiate between the superimposed modes, and any data taken is invalid. The previous method of dealing with mode-mixing was to turn off power to the cavity, let both modes decay fully, then restore power. Because of the time-sensitive nature of this testing, this leads to underestimates of Q0 or any radiant field emission present in the cavity. The novel RF control solution prevents the 7/9 pi mode from being excited while not interfering with measurements of the fundamental pi mode. A second RF control system is connected to the cavity which drives the 7/9 pi mode. The loop phase for driving the 7/9 pi mode in self excited loop mode is determined then shifted by 180 degrees, thus providing a negative feedback to the undesired mode. Because this off-resonance power can be very small, on the order of milliwatts, it does not interfere with the high-power measurements of the fundamental pi mode. At Jefferson Lab, we are now able to test a cavity for the LCLSII-HE project with no problems from mode-mixing, which allows for CW processing of high-gradient multipacting and field emission.

Owen, Peter↗

On the 2018 Outburst of the Accreting Millisecond X-Ray Pulsar Swift J1756.9-2508 As Seen with NICER

We report on the coherent timing analysis of the 182 Hz accreting millisecond X-ray pulsar SwiftJ1756.92508during its 2018 outburst as observed with the Neutron Star Interior Composition Explorer (NICER). Combiningour NICER observations with Rossi X-ray Timing Explorer observations of the 2007 and 2009 outbursts, we alsostudied the long-term spin and orbital evolution of this source. We find that the binary system is well describedby a constant orbital period model, with an upper limit on the orbital period derivative of Pb < 7.4 ´ 10-13 ss1.Additionally, we improve upon the source coordinates through astrometric analysis of the pulse arrival times,finding R.A.=17h56m57 18±0 08 and decl.=25°0627 8±3 5, while simultaneously measuring thelong-term spin frequency derivative as n = -7.3 ´ 10-16 Hzs1. We briefly discuss the implications of thesemeasurements in the context of the wider population of accreting millisecond pulsars. We reported on the coherent timing analysis of the 2018 outburst of Swift J1756 as observed with NICER. Consistent with analyses of the previous outbursts (Krimm et al. 2007b; Patruno et al. 2010), we find that the X-ray pulsations have energy dependent amplitudes; the fractional amplitude of the fundamental increases with energy, whereas the fractional amplitude of the harmonic shows a slight decline with energy. This energy dependent behavior is not unusual in AMXPs (Patruno & Watts 2012) and can be interpreted in terms of the thermal emission from the stellar hotspot and reprocessing in the accretion column (e.g., Gierliński et al. 2002; Ibragimov & Poutanen 2009). The pulse arrival times of the 2018 outburst are well described by a timing model consisting of a circular orbit with a constant spin frequency. The pulse phases with respect to this model do not show spurious residuals with time or orbital phase, and no evidence is found that the pulse arrival times exhibit an additional delay associated with passing through the gravitational well of the companion star (Shapiro delay). We note, however, that the expected Shapiro delay is given as (Shapiro et al. 1971) Equation (5) where Φ is the orbital phase, G is the gravitational constant, c is the speed of light, and i is the inclination. Even for the maximum allowed companion mass, ${M}_{C}=0.030\,{M}_{\odot }$ (Krimm et al. 2007b, but see Section 4.2 for more details) and an inclination of 90°, the largest delay we can expect is only 4 μs. As this time-delay is smaller than the uncertainty on our phase residuals by nearly two orders of magnitude (see Figure 1), we are not sensitive to Shapiro delays in Swift J1756. Comparing our measurements for the 2018 outburst with those of the 2007 and 2009 outbursts as observed with RXTE, we analyzed the long-term evolution of this source. We found that the binary system is consistent with having a constant orbital period and that the pulsar shows a spin frequency derivative of $\dot{\nu }=-7.3\times {10}^{-16}\,\mathrm{Hz}\,{{\rm{s}}}^{-1}$. 4.1. Spin-down Evolution The long-term spin frequency derivative measured in Swift J1756 is of the same order as the spin frequency derivatives measured in other AMXPs (Hartman et al. 2008; Patruno 2010; Riggio et al. 2011). This frequency change is most likely driven by the neutron star's loss of rotational energy. If so, then the spin-down luminosity is given as Equation (6) where I represents the neutron star moment of inertia. The long-term spin-down of a neutron star is usually assumed to be dominated by the braking torque associated with a spinning magnetic field. Assuming this mechanism is responsible for the observed spin-down in Swift J1756, we can compute the magnetic dipole moment as (Spitkovsky 2006) Equation (7) where α is the misalignment angle between the rotational and magnetic poles. Considering α = 0°–90°, we then find a magnetic field strength of $B\simeq (4\mbox{--}6)\times {10}^{8}$ G at the stellar magnetic poles. This magnetic field strength estimate is in line with those obtained for other accreting millisecond pulsars (see Mukherjee et al. 2015 and references therein). 4.2. Orbit Evolution The observed long-term binary evolution of Swift J1756 is consistent with this source having a constant orbital period and a lower limit on the evolutionary timescale of Equation (8) Binary evolution theory predicts that systems of this type evolve due to angular momentum loss through gravitational radiation (Kraft et al. 1962; Rappaport et al. 1982; Verbunt 1993). For conservative mass transfer, the binary period derivative is given by di Salvo et al. (2008), Equation (9) where MNS is the neutron star mass, $q={M}_{C}/{M}_{\mathrm{NS}}$ is the binary mass ratio, and −1/3 < n < 1 is the mass–radius index of the companion star. Depending on the source inclination, Krimm et al. (2007b) derived a companion mass of ${M}_{C}\,=0.007\mbox{--}0.022\,{M}_{\odot }$ for a neutron star mass of 1.4 ${M}_{\odot }$. For a neutron star mass of 2.2 ${M}_{\odot }$, the allowed range increased to ${M}_{C}=0.009\mbox{--}0.030\,{M}_{\odot }$. In both cases, they assumed an upper limit on the inclination of i < 85°, motivated by the fact that Swift J1756 does not show eclipses in its light curve. Accounting for the extreme cases of stellar masses and n, the binary may either be contracting or expanding. In either case, however, the rate of change is limited to $| {\dot{P}}_{b}| \lesssim 7\times {10}^{-14}$ s s−1, which is well below the upper limit obtained in this work. Although the binary evolution timescale we obtain for Swift J1756 is consistent with theory, it is worth noting that this is not generally true for low-mass X-ray binaries (see Patruno et al. 2017, for a comprehensive discussion). The AMXP SAX J1808.4–3658, in particular, has been found to evolve on a much shorter timescale, with a first derivative on the orbital period of $3.5\times {10}^{-12}$ s s−1 (Hartman et al. 2008; Patruno et al. 2012; Sanna et al. 2017a). Two models have been proposed to explain this discrepancy: highly nonconservative mass transfer due to irradiation of the companion star by the pulsar (di Salvo et al. 2008; Burderi et al. 2009), and spin–orbit coupling in the companion star (Hartman et al. 2008, 2009). While the latter depends on the companion star, and may vary from source to source, the former should operate in all AMXPs (see also Patruno 2017; Sanna et al. 2017c), including Swift J1756. The spin-down luminosity impinging on the companion star can be estimated as Equation (10) where ${\dot{E}}_{\mathrm{abl}}$ is the ablation luminosity, RL2 is the Roche lobe radius of the companion (Eggleton 1983), and a the binary separation. The irradiation fraction is $f={\dot{E}}_{\mathrm{abl}}/{\dot{E}}_{\mathrm{sd}}$, which, accounting for the range of allowed neutron star and companion masses, evaluates to f = 0.15%–0.35%. The associated mass loss for the companion is given by Equation (11) such that, assuming an efficiency of η = 100%, ${\dot{M}}_{C}\,\sim -3\times {10}^{-10}\,{M}_{\odot }$ yr−1. The effect of this mass loss on the orbital period follows through the relation (Frank et al. 2002) Equation (12) giving a period derivative due to mass loss of ${\dot{P}}_{b,\mathrm{ML}}\,=5\times {10}^{-12}$ s s−1. This value is well above our limit on the period derivative. Hence, in order for this mechanism to be consistent with our observations of Swift J1756, the efficiency at which the companion star converts the incident luminosity into mass loss must be η < 15%. This value is very different from the 40% required in SAX J1808.4–3658 (Patruno et al. 2016) and is instead in line with the <5% efficiency determined for IGR J00291+5934 (Patruno 2017). This work was supported by NASA through the NICER mission and the Astrophysics Explorers Program, and made use of data and software provided by the High Energy Astrophysics Science Archive Research Center (HEASARC). P.B. was supported by an NPP fellowship at NASA Goddard Space Flight Center. D.A. acknowledges support from the Royal Society.

Bult, Peter↗

Fundamental Consideration of Noise radiation by rotary wings

An historical review of progress in understanding of rotor noise is presented. Initial work was principally on propellers, but has many obvious applications to noise from rotary wings. Current understanding of rotor noise radiation is then reviewed in some detail. The principal noise sources appear to be: (1) discrete frequency due to distorted inflow; (2) low frequency broadband due to turbulent inflow, and (3) high frequency broadband due to tip effects. On a helicopter rotor each of these sources seems to be intimately connected with the shed vortex wakes. Tip modifications offer one method for controlling the effects. The implications for the designer are discussed. Rotor subjective noise levels appear to obey a velocity to the eighth power law, independent of thrust. Experiments to rectify some of the present deficiencies in knowledge are suggested.

Lowson, M. V.↗

O 2 dosage as a descriptor of TWC performance under lean/rich dithering in stoichiometric natural gas engines

The effects of oscillations in gas composition, known as lean/rich dithering, on the performance of a commercial Pd-based three-way catalyst (TWC) for stoichiometric natural gas (NG) engines were evaluated using synthetic exhaust flow reactor experiments. Under simulated NG exhaust conditions, NO conversion was intimately correlated to CH 4 conversion at slightly fuel-rich operating conditions. CH 4 conversion significantly varied with lambda (or O 2 concentration) and depended on the direction of the lambda change. The dynamic CH 4 conversion is likely related to the change of catalyst oxidation state and structures of Pd active sites. The CH 4 -NO cross-over point was found at a rich-biased lambda rather than stoichiometry. Compared to static operation, catalyst performance was much higher under a realistic dithering condition. The impacts of dithering parameters including amplitude and frequency on CH 4 and NO conversions were explored. O 2 dosage is proposed as an effective descriptor of the TWC dithering performance. In the O 2 -dosage space, the performance of distinct dithering parameters collapse, helping to elucidate the fundamental influence of dithering parameters on TWC performance. With the help of O2 dosage, an optimal operating window leading to high CH 4 and NO conversions was identified. A higher dithering amplitude is required to keep the catalyst in a reduced state for higher CH 4 and NO conversions, while an appropriate O 2 dosage that does not exceed the breakthrough OSC is necessary to avoid excess O 2 that results in NO slip. The dithering amplitude and O 2 -dosage-metric maps provide a new method for studying dynamic TWC performance and identifying optimum operation strategies.

03 NATURAL GAS↗

Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)

MAGIS-100 is a next-generation quantum sensor under construction at Fermilab that aims to explore fundamental physics with atom interferometry over a 100 m baseline. This novel detector will search for ultralight dark matter, test quantum mechanics in new regimes, and serve as a technology pathfinder for future gravitational wave detectors in a previously unexplored frequency band. It combines techniques demonstrated in state-of-the-art 10-meter-scale atom interferometers with the latest technological advances of the world’s best atomic clocks. MAGIS-100 will provide a development platform for a future kilometer-scale detector that would be sufficiently sensitive to detect gravitational waves from known sources. Here we present the science case for the MAGIS concept, review the operating principles of the detector, describe the instrument design, and study the detector systematics.

47 OTHER INSTRUMENTATION↗

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics↗

Cavity Based Searches for New Particles and Gravitational Waves

The Superconducting Quantum Materials and Systems Center, led by Fermi National Accelerator Laboratory, is one of five research centers funded by the U.S. Department of Energy as part of a national initiative to develop and deploy the world’s most powerful quantum computers and sensors. The SQMS Center uses world-record quality-factor superconducting radio-frequency, or SRF, cavities as ultra-sensitive quantum probes. Within the quantum sensing thrust, researchers are developing experiments based on cavities and novel quantum devices to search for particles beyond the Standard Model, dark matter candidates, gravitational waves and fundamental material properties. The seminar will focus mostly on Dark SRF and MAGO activities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diagrammatic Monte Carlo Approach to Real‐frequency Response Functions and the Spin‐Fermion Model of Hot Spots (Final Report)

This three‐year research project was focused on two outstanding condensed matter problems (i) Real‐frequency response functions in Coulomb systems at finite temperature, and Fermi surface (FS) reconstruction in the Spin-Fermion (SF) model. The uniform electron gas (jellium) model, describing electrons interacting via long‐range Coulomb forces on positive neutralizing background, is fundamentally important both for understanding the physics of correlated electrons and for formulation of the time‐dependent density functional theory (TDDFT). The spin-fermion model has found a wide range of applications in the physics of cuprates and iron‐based superconductors to explain the “strange metal" behavior and to suggest a possible pairing mechanism for high‐temperature superconductivity. The project’s goals were development and application of the Diagrammatic Monte Carlo (DiagMC) techniques for solving the above problems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The 12 micron band of ethane: A spectral catalog from 765 cm(-1) to 900 cm(-1)

The high resolution laboratory absorption spectrum of the 12 micro band of ethane gas is studied. The data were obtained using the McMath Solar Telescope 1 meter Fourier Transform interferometer at Kitt Peak National Observatory and tunable diode laser spectrometers at the University of Tennessee and NASA/Goddard Space Flight Center. Over 200 individual vibration rotation transitions were analyzed taking into account many higher order effects including torsional splitting. Line positions were reproduced to better than 0.001/cm. Both ground and upper state molecular constants were determined in the analysis. The experimental details, the analysis procedures and the results are addressed. A list of ethane transitions occurring near (14)CO2 laser lines needed for heterodyne searches for C2H6 in extraterrestrial sources is also included. A spectral catalog of the ethane nu sub g fundamental from 765/cm to 900/cm is provided. A high dispersion (1/cm 12 in.) plot of both the Kitt Peak interferometric data and a simulated spectrum with Doppler limited resolution, a table of over 8500 calculated transitions listed quantum number assignments, frequencies and intensities are provided.

Atakan, A. K.↗

Advances in spaceborne synthetic aperture radar sensor technology

The evolution of space SARs for NASA projects since Seasat (1978) is surveyed, with an emphasis on hardware development. The fundamental principles of SAR are reviewed; the SIR-A and SIR-B instruments flown as Shuttle payloads are characterized; their antennas, transmitters, receivers, and data subsystems are described; the advantages offered by the SIR-C dual-frequency (L and C band) dual-polarization distributed SAR (being developed for a future Shuttle flight and as the basis of an SAR for the Earth Observing System) are explained; and a number of technical challenges are identified (including RF elements, structural fidelity, pointing accuracy, data handling, and dc power). Drawings, diagrams, sample images, photographs, and tables are provided.

Caro, E. R.↗

Gradiometry and gravitomagnetic field detection

Gravitomagnetism was apparently first introduced into physics about 120 years ago when major developments in electrodynamics and the strong similarity between Coulomb's law of electricity and Newton's law of gravity led to the hypothesis that mass current generates a fundamental force of gravitational origin analogous to the magnetic force caused by charge current. According to general relativity, the rotation of a body leads to the dragging of the local inertial frames. In the weak-field approximation, the dragging frequency can be interpreted, up to a constant proportionality factor, as a gravitational magnetic field. There is, as yet, no direct evidence regarding the existence of such a field. The possibility is examined of detecting the gravitomagnetic field of the Earth by gravity gradiometry.

Mashhoon, Bahram↗

Noise from Two-Blade Propellers

The two-blade propeller, one of the most powerful sources of sound known, has been studied with the view of obtaining fundamental information concerning the noise emission. In order to eliminate engine noise, the propeller was mounted on an electric motor. A microphone was used to pick up the sound whose characteristics were studied electrically. The distribution of noise throughout the frequency range, as well as the spatial distribution about the propeller, was studied. The results are given in the form of polar diagrams. An appendix of common acoustical terms is included.

Stowell, E Z↗

Ultrasound Techniques for Space Applications

Ultrasound has proven to be a safe non-invasive technique for imaging organs and measuring cardiovascular function. It has unique advantages for application to problems with man in space including evaluation of cardiovascular function both in serial studies and during critical operations. In addition, specialized instrumentation may be capable of detecting the onset of decompression sickness during EVA activities. A spatial location and three-dimensional reconstruction system is being developed to improve the accuracy and reproducibility for serial comparative ultrasound studies of cardiovascular function. The three-dimensional method permits the acquisition of ultrasonic images from many views that can be recombined into a single reconstruction of the heart or vasculature. In addition to conventional imaging and monitoring systems, it is sometimes necessary or desirable to develop instrumentation for special purposes. One example of this type of development is the design of a pulsed-Doppler system to monitor cerebral blood flow during critical operations such as re-entry. A second example is the design of a swept-frequency ultrasound system for the detection of bubbles in the circulatory system and/or soft tissues as an early indication of the onset of decompression sickness during EVA activities. This system exploits the resonant properties of bubbles and can detect both fundamental and second harmonic emissions from the insonified region.

Rooney, James A.↗

Determination of Black Hole Mass in Cyg X-1 by Scaling of Spectral Index-QPO Frequency Correlation

It is well established that timing and spectral properties of Galactic Black Hole (BH) X-ray binaries (XRB) are strongly correlated. In particular, it has been shown that low frequency Quasi-Periodic Oscillation (QPO) nu(sub low) - photon index GAMMA correlation curves have a specific pattern. In a number of the sources studied the shape of the index-low frequency QPO correlations are self-similar with a position offset in the nu(sub low) - GAMMA plane determined by a BH mass M(sub BH). Specifically, Titarchuk & Fiorito (2004) gave strong theoretical and observational arguments that the QPO frequency values in this nu(sub low) - GAMMA correlation should be inversely proportional to M(sub BH). A simple translation of the correlation for a given source along frequency axis leads to the observed correlation for another source. As a result of this translation one can obtain a scaling factor which is simply a BH mass ratio for these particular sources. This property of the correlations offers a fundamentally new method for BH mass determination in XRBs. Here we use the observed QPO-index correlations observed in three BH sources: GRO J1655-40, GRS 1915+105 and Cyg X-1. The BH mass of (6.3 plus or minus 0.5) solar mass in GRO J1655-40 is obtained using optical observations. RXTE observations during the recent 2005 outburst yielded sufficient data to establish the correlation pattern during both rise and decay of the event. We use GRO J1655-40 as a standard reference source to measure the BH mass in Cyg X-1. We also revisit the GRS 1915+105 data as a further test of our scaling method. We obtain the BH mass in Cyg X-1 in the range 7.6-9.9.

Shaposhnikov, Nickolai↗

Opto-Electronic Oscillator Using Suppressed Phase Modulation

A proposed opto-electronic oscillator (OEO) would generate a microwave signal having degrees of frequency stability and spectral purity greater than those achieved in prior OEOs. The design of this system provides for reduction of noise levels (including the level of phase noise in the final output microwave signal) to below some of the fundamental limits of the prior OEOs while retaining the advantages of photonic generation of microwaves.

Dick, G. John↗