Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flux Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Interannual precipitation controls on soil CO 2 fluxes in high elevation conifer and aspen forests

Abstract Long-term soil CO 2 emission measurements are necessary for detecting trends and interannual variability in the terrestrial carbon cycle. Such records are becoming increasingly valuable as ecosystems experience altered environmental conditions associated with climate change. From 2013 to 2021, we continuously measured soil CO 2 concentrations in the two dominant high elevation forest types, mixed conifer and aspen, in the upper Colorado River basin. We quantified the soil CO 2 flux during the summer months, and found that the mean and total CO 2 flux in both forests was related to the prior winter’s snowfall and current summer’s rainfall, with greater sensitivity to rainfall. We observed a decline in surface soil CO 2 production, which we attributed to warming and a decrease in amount and frequency of summer rains. Our results demonstrate strong precipitation control on the soil CO 2 flux in mountainous regions, a finding which has important implications for carbon cycling under future environmental change.

54 ENVIRONMENTAL SCIENCES↗

Determination of impurities in cubic boron nitride (cBN) by inductively coupled plasma mass spectrometry (ICPMS)

The phase stability of cBN is critically dependent on the content and amount of impurities present. While studies have shown qualitatively that the addition of certain impurities can either increase or decrease the cBN-hBN phase transition temperature, studies have yet to show this effect quantitatively. This is because analytical methods to characterize minor and trace impurities in cBN are currently lacking. To this end, we present flux fusion methods capable of fully digesting cBN samples for ICPMS analyses. The materials used in this study are commercially available cBN powders in three different sizes. Two types of fluxes (LiOH and NaOH·H 2 O) are utilized so that both Li and Na impurities can be determined. To ensure the accuracy of Si measurements, a column chromatography method has been developed to purify Si from flux materials in order to increase the amount of dissolved sample sent to the ICP. Detection limits have been determined using procedural blanks and are found to be below 20 μg/g for all 58 elements analyzed except for Si, for which the detection limit is 312 μg/g. Nonetheless, all cBN powders studied are found to have high Si impurity levels that are above detection limit. This study provides a much-needed analytical protocol to enable comprehensive screening of impurities in cBN.

36 MATERIALS SCIENCE↗

Spatial and temporal variation in forest transpiration across a forested boreal peatland complex

Transpiration is a globally important component of evapotranspiration. Careful upscaling of transpiration from point measurements is thus crucial for quantifying water and energy fluxes. In spatially heterogeneous landscapes common across the boreal biome, upscaled transpiration estimates are difficult to determine due to variation in local environmental conditions (e.g., basal area, soil moisture, permafrost). Here, we sought to determine stand-level attributes that influence transpiration scalars for a forested boreal peatland complex consisting of sparsely treed wetlands and densely treed permafrost plateaus as land cover types. The objectives were to quantify spatial and temporal variability in stand-level transpiration, and to identify sources of uncertainty when scaling point measurements to the stand-level. Using heat ratio method sap flow sensors, we determined sap velocity for black spruce and tamarack for 2-week periods during peak growing season in 2013, 2017 and 2018. We found greater basal area, drier soils, and the presence of permafrost increased daily sap velocity in individual trees, suggesting that local environmental conditions are important in dictating sap velocity. When sap velocity was scaled to stand-level transpiration using gridded 20 × 20 m resolution data across the ~10 ha Scotty Creek ForestGEO plot, we observed significant differences in daily plot transpiration among years (0.17–0.30 mm), and across land cover types. Daily transpiration was lowest in grid-cells with sparsely treed wetlands compared to grid-cells with well-drained and densely treed permafrost plateaus, where daily transpiration reached 0.80 mm, or 30% of the daily evapotranspiration. When transpiration scalars (i.e., sap velocity) were not specific to the different land cover types (i.e., permafrost plateaus and wetlands), scaled stand-level transpiration was overestimated by 42%. To quantify the relative contribution of tree transpiration to ecosystem evapotranspiration, we recommend that sampling designs stratify across local environmental conditions to accurately represent variation associated with land cover types, especially with different hydrological functioning as encountered in rapidly thawing boreal peatland complexes.

54 ENVIRONMENTAL SCIENCES↗

NCSU Flux Tower Data

NCSU Flux Tower Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument descripotion Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Sonic Anemometer, 3 Condensation Particle Counters, 1 SP2, 1 POPS Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU flux tower was located next to the AMF sampling pad. The flux tower consisted of a 10 m telescoping tower. Mounted at the top of the tower was a sonic anemometer (RM Young 8000) and a Krypton Hygrometer. A sample line (¼” conductive tubing) and communication line was laid to a trailer located underneath and slightly adjacent to the tower. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts. Also sampling was a printed particle optical spectrometer (POPS) and a single particle soot photometer (SP2). Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

Scalar flux transport models for self-similar turbulent mixing

A common approach to closing turbulent species flux in multicomponent Reynolds-averaged Navier-Stokes models is to use the standard gradient diffusion approximation. While such an approach has been shown to work well when applied to many canonical turbulent mixing configurations, a gradient diffusion approach is fundamentally limited in its ability to capture complex phenomena such as countergradient transport. For this reason, complicated mixing applications may benefit by treating the turbulent diffusivity with a model transport equation in a manner analogous to second-moment momentum closure in Reynolds-stress transport models. Here, the present work explores the development and application of two different scalar flux transport (SFT) models. Self-similarity constraints are derived for these models, and they are evaluated against gradient-diffusion-based models in several one- and two-dimensional problems of turbulent mixing. It is found that the new SFT models out-perform gradient diffusion models in problems involving rapid acceleration reversal and in problems involving anisotropic transport of materials. In addition, it is found that even a hybrid-SFT approach, in which an SFT equation is utilized along with a gradient diffusion closure, provides some measure of improvement over models that transport the mass flux rather than the scalar flux.

Reynolds-averaged Navier Stokes↗

The Diurnal Cycle of East Pacific Convection, Moisture, and CYGNSS Wind Speed and Fluxes

The far eastern tropical Pacific is one of the rainiest locations on Earth. This region is characterized by a robust diurnal cycle with precipitation initiating over the Andes mountains in Colombia in the late afternoon and moving offshore overnight while organizing into mesoscale convective systems (MCSs). As the MCSs move westward, they can seed tropical easterly waves that develop into tropical cyclones. Novel measurements of near-surface wind speeds and latent heat flux (LHFLX) from the Cyclone Global Navigation Satellite System (CYGNSS) mission and ERA5 reanalysis are used to evaluate changes to regional flow patterns, moisture, and LHFLX that favor a strong westward propagating diurnal cycle of precipitation in this region. Days with strongly versus weakly westward propagating diurnal precipitation are compared during the extended boreal summer of the CYGNSS era (May–October 2018–2021). Strongly propagating days have a more moist lower troposphere with stronger vertically integrated moisture flux convergence than days with weakly propagating precipitation. The enhanced low-level moisture is supported by increased wind-driven LHFLX from stronger regional flows including the Choco and Caribbean Low-Level Jets and Panama and Papagayo gap winds. Increased offshore convergence and vorticity also help sustain convection during the days with strongly propagating precipitation. Background variations in the physical environment, as opposed to diurnal variations, seem more important for supporting a robust diurnal cycle of precipitation in the region.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Implications of first neutrino-induced nuclear recoil measurements in direct detection experiments: Probing nonstandard interaction via CE ν NS

PandaX-4T and XENONnT have recently reported the first measurement of nuclear recoils induced by the B 8 solar neutrino flux, through the coherent elastic neutrino-nucleus scattering ( CE ν NS ) channel. As long anticipated, this is an important milestone for dark matter searches as well as for neutrino physics. This measurement means that these detectors have reached exposures such that searches for low mass, ≲ 10 GeV dark matter cannot be analyzed using the background-free paradigm going forward. It also opens a new era for these detectors to be used as neutrino observatories. In this paper we assess the sensitivity of these new measurements to new physics in the neutrino sector. We focus on neutrino nonstandard interactions (NSI) and show that—despite the still moderately low statistical significance of the signals—these data already provide valuable information. We find that limits on NSI from PandaX-4T and XENONnT measurements are comparable to those derived using combined COHERENT CsI and LAr data. Furthermore, they provide sensitivity to pure τ flavor parameters that are not accessible using stopped-pion or reactor sources. With larger exposures and consequently improvements of statistical uncertainties, forthcoming data from these experiments will provide important, novel results for CE ν NS -related physics. Published by the American Physical Society 2025

Sierra, D. Aristizabal↗

RadSim: Math, Utility & RTK

This package includes three parts, (1) gov.llnl.math, (2)gov.llnl.utility and (3)gov.llnl.rtk, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The techniques and implementation will be entirely transparent, which will allow for improvements and boutique modifications by future researchers beyond the lifespan of this specific project. The first tool of the package, gov.llnl.math, includes classes and functions to define and perform basic math operations. Some of the example features available in the package include defining statistical distributions and performing algebra and matrix operations, all of which are already accessible on publicly available software packages such as MATLAB and ROOT. The second package gov.llnl.utility includes tools commonly used to enable optimization and readability of various data structures such as Java lists and external xml files. Lastly, the gov.llnl.rtk package includes classes and functions to implement methods commonly used in radiation physics, such as data structures to represent and characterize photon spectra and tools to apply well-defined and published methods to calibrate a given spectra.

Cheung, Hoi Sing↗

RadSim: ENSDF, Xray and N42

This package includes three parts, (1) gov.bnl.nndc.ensdf, (2) gov.nist.xray and (3) gov.nist.physics.n42, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The first tool of the package, gov.bnl.nndc.ensdf, includes functionality to parse and split publicly available decay records in ENSDF format, and pull the relevant information from ENSDF libraries. The second tool, gov.nist.xray, provides Xray information using the public NIST database. Lastly, gov.nist.physics.n42, is a tool used to convert an N42 xml file into a Java object that can be interfaced within a Java program.

Hangal, DnaushA↗

Tower - TTU (SWiFT) Tower, All levels - Processed Data

This dataset includes processed sonic anemometer measurements at the 200-m SWIFT tower near Lubbock, Texas on July 4, 2012. Observations are of a canonical convective atmospheric boundary layer. Subgrid stresses and fluxes are computed by subtracting 15-min running average from the signals measured at 1 Hz.

17 WIND ENERGY↗

Magnetic-Field Diffusion Effects in Beam Position Monitors I: Theory

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

Raw Data published in PeerJ, 2021 for Crested Butte decomposition field study 2017-2019.

This data package contains text files that describe geochemical measurements collected from 2017-2019 during isolated conifer needle decomposition field studies in Crested Butte, Colorado. The geochemical measurements were collected across three elevations (2,800–3,500 m) ranging from montane to subalpine ecoregions. The data sets within include total carbon and nitrogen content and fourier-transform infrared spectroscopy (FTIR) results for the initial needles collected in 2016 and after decomposition in 2019. Data collection results from August 2020 are also included from when the experimental plots were removed to understand final concentrations of soil extractable carbon and nitrogen content as well as mass balances from litter bag deployments. Soil porewater results are also provided from 2017-2019 for DOC, TN, UV254, and specific UV absorbance (SUVA) analyses at 15 cm soil depth. Gas flux raw data provides CO2, CH4, N2O, and NH3 measurements above needle decomposition over the three study years. Finally, soil samples for microbial DNA extractions were collected from the upper soil depth. This raw data is available in the NCBI SRA database under SRA accession numbers PRJNA605259 and PRJNA715914. These data sets were generated to investigate the isolated decomposition of spruce and lodgepole conifer needles. The goal of this work was to determine the roles of elevation, soil type, seasonal changes in soil moisture, and snowmelt timing on litter decomposition processes. Results from this work are detailed in the reference paper "Effect of elevation, season and accelerated snowmelt on biogeochemical processes during isolated conifer needle litter decomposition. DOI: 10.7717/peerj.11926."

54 ENVIRONMENTAL SCIENCES↗

PreMevE‐MEO: Predicting Ultra‐Relativistic Electrons Using Observations From GPS Satellites

Abstract Ultra‐relativistic electrons with energies greater than or equal to two megaelectron‐volt (MeV) pose a major radiation threat to spaceborne electronics, and thus specifying those highly energetic electrons has a significant meaning to space weather communities. Here we report the latest progress in developing our predictive model for MeV electrons in the outer radiation belt. The new version, primarily driven by electron measurements made along medium‐Earth‐orbits (MEO), is called PREdictive MEV Electron (PreMevE)‐MEO model that nowcasts ultra‐relativistic electron flux distributions across the whole outer belt. Model inputs include >2 MeV electron fluxes observed in MEOs by a fleet of GPS satellites as well as electrons measured by one Los Alamos satellite in the geosynchronous orbit. We developed an innovative Sparse Multi‐Inputs Latent Ensemble NETwork (SmileNet) which combines convolutional neural networks with transformers, and we used long‐term in situ electron data from NASA's Van Allen Probes mission to train, validate, optimize, and test the model. It is shown that PreMevE‐MEO can provide hourly nowcasts with high model performance efficiency and high correlation with observations. This prototype PreMevE‐MEO model demonstrates the feasibility of making high‐fidelity predictions driven by observations from longstanding space infrastructure in MEO, thus has great potential of growing into an invaluable space weather operational warning tool.

79 ASTRONOMY AND ASTROPHYSICS↗

Qualification of Commercially Available Silicon Carbide for Passive Thermometry in Reactor Experiments – FY23 Status Report

Silicon carbide (SiC) is often used as a passive temperature indicator for uninstrumented in-core nuclear experiments. For the past several decades, Oak Ridge National Laboratory has relied primarily on SiC thermometry manufactured by Dow Chemical Company, formerly Rohm and Haas because of the material’s high density and reduced grain boundary elements. Although Dow SiC has performed well in this application, this material is no longer commercially available, and a new supplier is needed for future experiments. To determine a suitable replacement, a study was initiated on five types of SiC from four commercial vendors. Several critical properties, including density, electrical resistivity, chemical purity, grain structure, crystal structure, and strength were measured in samples from each material. Additionally, thermometry specimens were manufactured for irradiation in the High Flux Isotope Reactor at nominal temperatures of 300°C, 600°C, and 900°C, which will be measured using continuous dilatometry at a later date. This report provides an update of commercially available SiC material characterization and the irradiation capsule design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision measurement of relative γ-ray intensities from the decay of 61Cu

A discrepancy, well outside reported uncertainties, has been observed between the accepted and measured values of the intensity ratio of the two strongest γ-ray following 61 Cu β + decay. This discrepancy has significant impact since the nat Ni(d,x) 61 Cu reaction has historically been one of only a few IAEA recommendations for use as a deuteron flux monitor and a considerable number of published cross sections measured in ratio to that beam monitor cross section may depend on the choice of either the first or second strongest ray in those calculations. To determine the magnitude of this error most precisely, over a hundred separate measurements of the 283 keV to 656 keV γ-ray emission ratio were collected from seven experiments and a variety of detectors and detection geometries. A weighted average of all these measurements indicates an error in the value listed in the Nuclear Data Sheets of 11% in either the primary or second-highest intensity γ-ray of 61 Cu, potentially introducing an 11% error in 61 Cu production cross section measurements, cross sections using nickel activation as a deuteron beam current monitor, or in dose rates when 61 Cu is used in nuclear medicine. General agreement with the Data Sheets with ten other intensity ratios suggests the most probable error is in the secondary (656 keV) emission, which accordingly should be updated from 10.8% to 9.69%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗