Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fast charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry

In the framework of the ICERR (International Center based on Research Reactors) project, the effect of neutron/gamma irradiation on material and dosimeters has been studied. In this work, we explore the alanine dose-response in the core of the MINERVE research reactor at the CEA Cadarache and we investigate the neutron heating effects in order to evaluate alanine neutron sensitivity. The measured dose of the alanine detector in the mixed gamma-neutron field was estimated by electron spin resonance spectrometry (ESR) with reference to an absorbed dose in water from a 60 Co gamma-ray beam. The experimental sources of uncertainties were reduced by using the optimum conditions of charged-particle equilibrium (CPE), obtained by introducing alanine dosimeters into the aluminum pillbox. Cavity correction factors and dose components were evaluated by the Monte Carlo code MCNP. The calculation showed an underestimated neutron dose with a (C/E) value of about 0.993 +/- 10.83%(k = 1). Results indicate that the fast neutron dose, mainly due to elastic neutron scattering on hydrogen nuclei, represents about 70% of the total dose, while the gamma dose was found to be around 45% of the neutron dose. Additionally, the neutron relative efficiency (REn) to 60 Co gamma-radiation was estimated to be 0.544 +/- 8%(k = 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low-power anisotropic molecular electronic memristors

A molecular electronic memristor, programmable resistive memory device, promises to revolutionize next-generation flexible data storage units, offering fast, dense and ultralow power solutions. Here we report anisotropic resistive switching in molecular κ-(BEDT-TTF) 2 Cu[N(CN) 2 ]Cl memristors, consisting of alternatively segregated bis(ethylenedithio)tetrathiafulvalene (BEDT-TTF) and Cu[N(CN) 2 ]Cl layers. Electron resistance switching behavior controlled by charge tunneling in molecular memristors show a low set voltage of 0.5 V (10 V/cm) with the ON/OFF ratio of 2.3×10 3 along a-axis and a high-level endurance of 1.25×10 4 cycles along all axes. Finally, the findings of such molecular electronic crystals promise for low-power data storage memristors.

36 MATERIALS SCIENCE↗

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structures of strong shocks in low-density helium and neon gases

Strong shocks are essential components in many high-energy-density environments such as inertial confinement fusion implosions. However, the experimental measurements of the spatial structures of such shocks are sparse. In this paper, the soft x-ray emission of a shock front in a helium gas mixture (90% helium, 10% neon) and a pure neon gas was spatially resolved using an imaging spectrometer. We observe that the shock width in the helium mixture gas is about twice as large as in the pure neon gas. Moreover, they exhibit different precursor layers, where electron temperature greatly exceeds ion temperature, extending for more than ~350 µm with the helium gas mixture but less than 30 µm in the pure neon. At the shock front, calculations show that the electrons are strongly collisional with mean-free path two orders of magnitude shorter than the characteristic length of the shock. However, the helium ions can reach a kinetic regime as a consequence of their mean-free path being comparable to the scale of the shock. A radiation-hydrodynamic simulation demonstrates the impact of thermal conduction on the formation of the precursors with charge state, Z, playing a major role in heat flow and the precursor formation in both the helium mixture and the pure neon gases. Particle-in-cell simulations are also performed to study the ion kinetic effects on the formation of the observed precursors. A group of fast-streaming ions is observed leading the shock only in the helium gas mixture. Additionally, both effects explain the longer precursor layer in the helium shock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

A Meteoroid Handbook for Aerospace Engineers and Managers

At the beginning of the Space Age, spacecraft designers and mission planners were very concerned about meteoroids. They envisioned vehicles being ripped to pieces by streams of fast-moving space rocks, a notion promoted by the science fiction novels and movies of the time. The reality is, of course, different—the meteoroid streams that produce meteor showers are not dense by laypeople’s standards, having spatial densities of just a handful of particles per cubic kilometer, even during meteor outbursts. The ever-present, diffuse, sporadic background, which produces observed meteor rates of only 5 to 8 meteors per hour, makes up 90% of the meteoroid risk to spacecraft that spend at least a year in low Earth orbit (LEO), whereas the visually spectacular but short-lived meteor showers make up the other 10%. Still, meteoroids do pose a significant risk to spacecraft. At Earth, they can travel 12 to 72 km/s. These high speeds cause even small meteoroids to carry enormous kinetic energy, making them capable of doing serious damage to spacecraft. For example, a 1-mm-diameter meteoroid moving at 25 km/s can inflict the same damage as a bullet fired from a 0.357 Magnum pistol. An exterior wire can be severed by a 0.1-mm (100 mm) particle, a spacesuit can be penetrated by a 0.5-mm meteoroid, and an unshielded pressure wall (like the cabin of the Space Shuttle) can be perforated by centimeter-sized particles. Along with mechanical damage, meteoroids can also cause other types of spacecraft anomalies. Meteoroids can transfer their momentum to the spacecraft, which can destroy or damage equipment such as shunt resistors and charge-coupled device (CCD) detectors with a clear view of space. Meteoroid impacts can also generate plasma. The impact vaporizes material, producing a crater and an expanding plasma, which can in turn provide a conductive path for any charge accumulated on the spacecraft. This effect is thought to be responsible for the demise of a satellite in one case: the OLYMPUS communications satellite was sent tumbling out of control during the 1993 Perseid outburst, and a Perseid meteoroid strike has been posited as a possible cause (McDonnell et al. 1993; Caswell et al. 1995). Other researchers have suggested that very fast meteoroids could produce a small electromagnetic pulse capable of disrupting spacecraft function (Close et al. 2010).

Moorhead, A.↗

Redox Couples Control Band Bending, Photovoltage, and Quasi-Fermi Levels in Tungsten Oxide (WO 3 ) Photoanodes

Tungsten oxide (WO 3 ) is a well-known photoanode and photocatalyst for photoelectrochemical (PEC) water oxidation. Because the compound has a deep valence band, it can facilitate the oxygen evolution reaction without added cocatalysts, and it can drive the oxidation of species with much higher electrochemical potentials, including the conversion of water to hydrogen peroxide, sulfate to persulfate, and iodate to meta-periodate. Here, we use the liquid vibrating Kelvin probe surface photovoltage (liquid VK-SPV) technique in combination with open circuit potential (OCP) and photoelectrochemical (PEC) scans to assess the possibility of reaching such oxidizing potentials in aqueous electrolytes and at open circuit. Here, this is done by mapping the quasi-Fermi levels of electrons and holes at the interfaces as a function of the light intensity. Nanostructured WO 3 photoelectrodes for this purpose were fabricated by thermal annealing of a tungstic acid solution on fluorine-doped tin oxide. Electrochemical measurements are conducted at open circuit and 400 nm LED light illumination in electrolytes containing fast (O 2 /H 2 O 2 ), slow (O 2 /H 2 O), and very oxidizing (NaIO 4 /NaIO 3 ) redox couples. Photovoltage values scale with the light intensity and with the built-in potential for each redox couple and reach values up to 0.61 V under 20 mW cm –2 illumination for the NaIO 4 electrolyte. This shows that the photoelectrodes behave like Schottky-type diodes whose maximum possible energy output is determined mainly by the built-in voltage of each junction. For slow redox couples, the quasi-Fermi level of the holes increases with light intensity due to hole accumulation at the WO 3 –liquid interface. For example, for the O 2 /H 2 O electrolyte, interfacial hole accumulation and removal occur on the 90–300 s time scale. For the fast hole acceptor H 2 O 2 , on the other hand, the quasi-Fermi level of the photoholes is pinned to the electrochemical potential of the O 2 /H 2 O 2 couple. This limits the energy conversion efficiency of the electrode. Overall, these results reveal the influence of charge transfer thermodynamics and kinetics on the photovoltage of WO 3 . Furthermore, the work further establishes VK-SPV as a contactless method to observe the photovoltage, carrier dynamics, and quasi-Fermi levels of semiconductor-liquid junctions.

Electrodes↗

Progress toward picosecond on-chip magnetic memory

Here, we offer a perspective on the prospects of ultrafast spintronics and opto-magnetism as a pathway to high-performance, energy-efficient, and non-volatile embedded memory in digital integrated circuit applications. Conventional spintronic devices, such as spin-transfer-torque magnetic-resistive random-access memory (STT-MRAM) and spin–orbit torque MRAM, are promising due to their non-volatility, energy-efficiency, and high endurance. STT-MRAMs are now entering into the commercial market; however, they are limited in write speed to the nanosecond timescale. Improvement in the write speed of spintronic devices can significantly increase their usefulness as viable alternatives to the existing CMOS-based devices. In this article, we discuss recent studies that advance the field of ultrafast spintronics and opto-magnetism. An optimized ferromagnet–ferrimagnet exchange-coupled magnetic stack, which can serve as the free layer of a magnetic tunnel junction (MTJ), can be optically switched in as fast as ~3 ps. Integration of ultrafast magnetic switching of a similar stack into an MTJ device has enabled electrical readout of the switched state using a relatively larger tunneling magnetoresistance ratio. Purely electronic ultrafast spin–orbit torque induced switching of a ferromagnet has been demonstrated using ~6 ps long charge current pulses. We conclude our Perspective by discussing some of the challenges that remain to be addressed to accelerate ultrafast spintronics technologies toward practical implementation in high-performance digital information processing systems.

42 ENGINEERING↗

Comparison of Model Predictions and Performance Test Data for a Prototype Thermal Energy Storage Module

Although model predictions of thermal energy storage (TES) performance have been explored in previous investigations, relevant test data that enable experimental validation of performance models have been limited. This is particularly true for high-performance TES designs that facilitate fast input and extraction of energy. In this paper, we present a summary of experimental tests of a high-performance TES unit using lithium nitrate trihydrate phase change material as a storage medium. Performance data are presented for complete dual-mode cycles consisting of extraction (melting) followed by charging (freezing). These tests simulate the cyclic operation of a TES unit for asynchronous cooling in a variety of applications. Finally, the model analysis is found to agree reasonably well, within 10%, with the experimental data except for conditions very near the initiation of freezing, a consequence of subcooling that is required to initiate solidification.

25 ENERGY STORAGE↗

The application of diffusion theory to the analysis of hydrogen desorption data at 25 deg C

The application of diffusion theory to the analysis of hydrogen desorption data (coulombs of H2 desorbed versus time) has been studied. From these analyses, important information concerning hydrogen solubilities and the nature of the hydrogen distributions in the metal has been obtained. Two nickel base alloys, Rene' 41 and Waspaloy, and one ferrous alloy, 4340 steel, are studied in this work. For the nickel base alloys, it is found that the hydrogen distributions after electrolytic charging conforms closely to those which would be predicted by diffusion theory. For Waspaloy samples charged at 5,000 psi, it is found that the hydrogen distributions are essentially the same as those obtained by electrolytic charging. The hydrogen distributions in electrolytically charged 4340 steel, on the other hand, are essentially uniform in nature, which would not be predicted by diffusion theory. A possible explanation has been proposed. Finally, it is found that the hydrogen desorption is completely explained by the nature of the hydrogen distribution in the metal, and that the fast hydrogen is not due to surface and sub-surface hydride formation, as was originally proposed.

Danford, M. D.↗

Revealing charge carrier dynamics and transport in Te-doped GaAsSb and GaAsSbN nanowires by correlating ultrafast terahertz spectroscopy and optoelectronic characterization

Recent advances in the growth of III-V semiconductor nanowires (NWs) hold great promise for nanoscale optoelectronic device applications. It is established that a small amount of nitrogen (N) incorporation in III-V semiconductor NWs can effectively red-shift their wavelength of operation and tailor their electronic properties for specific applications. Still, understanding the impact of N incorporation on non-equilibrium charge carrier dynamics and transport in semiconducting NWs is critical in achieving efficient semiconducting NW devices. In this work, ultrafast optical pump-terahertz probe spectroscopy has been used to study non-equilibrium carrier dynamics and transport in Te-doped GaAsSb and dilute nitride GaAsSbN NWs, with the goal of correlating these results with electrical characterization of their equilibrium photo-response under bias and low-frequency noise characteristics. Nitrogen incorporation in GaAsSb NWs led to a significant increase in the carrier scattering rate, resulting in a severe reduction in carrier mobility. Carrier recombination lifetimes of 33 ± 1 picoseconds (ps) and 147 ± 3 ps in GaAsSbN and GaAsSb NWs, respectively, were measured. The reduction in the carrier lifetime and photoinduced optical conductivities are due to the presence of N-induced defects, leading to deterioration in the electrical and optical characteristics of dilute nitride NWs relative to the non-nitride NWs. Finally, we observed a very fast rise time of ~2 ps for both NW materials, directly impacting their potential use as high-speed photodetectors.

36 MATERIALS SCIENCE↗

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atmospheric pressure plasmas interacting with wet and dry microchannels: reverse surface ionization waves

Atmospheric pressure plasma jets (APPJs) are increasingly being used to functionalize polymers and dielectric materials for biomedical and biotechnology applications. Once such application is microfluidic labs-on-a-chip consisting of dielectric slabs with microchannel grooves hundreds of microns in width and depth. The periodic channels, an example of a complex surface, present challenges in terms of directly and uniformly exposing the surface to the plasma. In this paper, we discuss results from computational and experimental investigations of negative APPJs sustained in Ar/N 2 mixtures flowing into ambient air and incident onto a series of microchannels. Results from two-dimensional plasma hydrodynamics modeling are compared to experimental measurements of electric field and fast-camera imaging. The propagation of the plasma across dry microchannels largely consists of a sequence of surface ionization waves (SIWs) on the top ridges of the channels and bulk ionization waves (IWs) crossing over the channels. The IWs are directed into electric field enhanced vertices of the next ridge. The charging of these ridges produce reverse IWs responsible for the majority of the ionization. The propagation of the plasma across water filled microchannels evolve into hopping SIWs between the leading edges of the water channels, regions of electric enhancement due to polarization of the water. Positive, reverse IWs follow the pre-ionized path of the initial negative waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Plasma wave spectra near slow mode shocks in the distant magnetotail

Recently Feldman et al. (1984) used ISEE-3 data to analyze variations in charged particle and magnetic field characteristics near plasma sheet boundaries in the distant magnetotail, and they demonstrated that several of the crossings had the properties of slow mode shocks. ISEE-3 plasma wave measurements at two of these crossings are presently discussed, and it is shown that all conventional characteristics of fast collisionless shock spectra are present. Upstream (lobe side) electron plasma oscillations are detected in association with electron heat flux enhancements, and pronounced spectral peaks at lower frequencies are found within the shock layer.

Scarf, F. L.↗

High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

Ponseggi, B. G.↗