Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

PS Ripple Study during the 2019 Fermilab Booster Experiment

S.02 has been one of the experiment of the 2019 Fermilab Booster Studies. Its goal had been to evaluate the tune ripple on beam stability. A prerequisite is to measure the voltage ripple in both AC and DC mode. With a good knowledge of the Booster transmission line model one can determine how voltage ripple leads to tune modulation depth at the same ripple frequency.

43 PARTICLE ACCELERATORS↗

Sensor Fish: an autonomous sensor package for characterizing complex flow fields and fish passage

Fish passing through dams or other hydraulic structures may be injured or killed despite advances in turbine design, project operations, and other fish bypass systems. The Sensor Fish (SF) device is an autonomous sensor package that characterizes the physical conditions and stressors to which fish are exposed during passage through hydro facilities. It was designed to move passively as a neutrally buoyant object through severe hydraulic environments, while collecting high-resolution sensor data. Since its first generation1, the SF device has been successfully deployed in many fish passage studies and has evolved to be a major tool for characterizing fish passage conditions during fish passage in the Columbia River Basin. To better accelerate hydropower development, the U.S. Department of Energy Water Power Program provided funding to develop a new generation (Gen 2 SF) to incorporate more capabilities and accommodate a wider range of users over a broader range of turbine designs and operating environments. The Gen 2 SF (Figure 1) is approximately the size and density of a yearling salmon smolt and is nearly neutrally buoyant. It contains three-dimensional (3D) rotation sensors, 3D linear acceleration sensors, a pressure sensor, a temperature sensor, a 3D orientation sensor, a radiofrequency (RF) transmitter, and a recovery module2. A low-power microcontroller collects data from the sensors and stores up to 5 min of data on internal flash memory at a sampling frequency of 2048 Hz. The recovery module makes the SF positively buoyant after a pre-programmed period of time, causing it to float to the surface for recovery.

Sensor Fish↗

Development of a Real-time Modulation Control System on the JT-60U ECRF System

A real-time modulation control system was developed for studying the effectiveness of modulated Electron Cyclotron Current Drive (ECCD) on the stabilization of Neoclassical Tearing Modes (NTMs). The phase and duty cycle tracking was enabled with high accuracy even if the NTM frequency varied during ECCD. A characteristic of an anode voltage modulation for modulating the gyrotron oscillation that caused the time variation of the phase and duty cycle was also taking into account. It was shown that the phase and duty cycle could be kept the target values within 50 ms even if the frequency varied by 1 kHz/s or higher at a frequency of around 5 kHz. Then, NTM stabilization experiments with modulated ECCD for m/n = 2/1 NTM was successfully performed in JT-60U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Method to Reduce the Coherent Betatron Oscillations in a Muon g-2 Storage Ring Experiment using RF Fields

The muon $g-2$ storage-ring experiments store a beam of polarized muons in a weak focusing storage ring. As the ensemble of muons goes around the ring, their spin precesses, and when they decay through the weak interaction: $\mu^+ \rightarrow e^+ \nu_e \bar{\nu_\mu}$ the decay positrons are detected by electromagnetic calorimeters. In addition to the expected exponential decay in the positron time spectrum, the weak decay asymmetry causes a modulation in the number of positrons at the difference frequency between the spin and cyclotron frequencies, $\omega_a$. This frequency is directly proportional to the magnetic anomaly $a =(g-2)/2$, where $g$ is the gyromagnetic ratio of the muon, which is slightly greater than 2. The detector acceptance depends on the radial position of the muon decay, so the coherent betatron oscillations (CBO) of the muon bunch following injection into the storage ring amplitude modulates the measured muon signal with the frequency $\omega_{CBO}$. A new method using radio frequency (RF) electric fields has the potential to significantly decrease the beam CBO, and additionally to scrape the beam to reduce muon losses from the storage ring during the measurement period.

43 PARTICLE ACCELERATORS↗

Cross-phase modulation between lasers in a tunnel ionizing gas

The phase modulation of a low power long pulse probe laser beam in a rapidly tunnel ionizing gas (helium) under a relativistic short pulse laser is investigated. The relativistic pulse creates a fast increasing plasma density at its front, far ahead of the intensity peak. The probe pulse sees these changes as modulation in its phase and undergoes large frequency upshift. The spectral content of the blueshifted potion of the probe pulse is large when its intensity peak commoves with the ionization front. There are two ionization front created by first and second ionizations, and the separation between the two increases as laser propagates through the gas. The rate of density variation by first and second ionizations, however, is fairly the same and varies little as the spot size of the laser beam increases up to three times its initial value. The ionization front velocity, as well as the upshift in probe pulse frequency, is bigger for sharper laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quasi-periodic Pulse Amplitude Modulation in the Accreting Millisecond Pulsar IGR J00291+5934

We introduce a new method for analyzing the aperiodic variability of coherent pulsations in accreting millisecond X-ray pulsars (AMXPs). Our method involves applying a complex frequency correction to the time-domain light curve, allowing for the aperiodic modulation of the pulse amplitude to be robustly extracted in the frequency domain. We discuss the statistical properties of the resulting modulation spectrum and show how it can be correlated with the non-pulsed emission to determine if the periodic and aperiodic variability are coupled processes. Using this method, we study the 598.88 Hz coherent pulsations of the AMXP IGR J00291+5934 as observed with the Rossi X-ray Timing Explorer and XMM-Newton . We demonstrate that our method easily confirms the known coupling between the pulsations and a strong 8 mHz quasi-periodic oscillation (QPO) in XMM-Newton observations. Applying our method to the RXTE observations, we further show, for the first time, that the much weaker 20 mHz QPO and its harmonic are also coupled with the pulsations. We discuss the implications of this coupling and indicate how it may be used to extract new information on the underlying accretion process.

79 ASTRONOMY AND ASTROPHYSICS↗

Fluid simulation of the bias effect in inductive/capacitive discharges

Computer simulations are performed for an argon inductively coupled plasma (ICP) with a capacitive radio-frequency bias power, to investigate the bias effect on the discharge mode transition and on the plasma characteristics at various ICP currents, bias voltages, and bias frequencies. When the bias frequency is fixed at 13.56 MHz and the ICP current is low, e.g., 6 A, the spatiotemporal averaged plasma density increases monotonically with bias voltage, and the bias effect is already prominent at a bias voltage of 90 V. The maximum of the ionization rate moves toward the bottom electrode, which indicates clearly the discharge mode transition in inductive/capacitive discharges. At higher ICP currents, i.e., 11 and 13 A, the plasma density decreases first and then increases with bias voltage, due to the competing mechanisms between the ion acceleration power dissipation and the capacitive power deposition. At 11 A, the bias effect is still important, but it is noticeable only at higher bias voltages. At 13 A, the ionization rate is characterized by a maximum at the reactor center near the dielectric window at all selected bias voltages, which indicates that the ICP power, instead of the bias power, plays a dominant role under this condition, and no mode transition is observed. Indeed, the ratio of the bias power to the total power is lower than 0.4 over a wide range of bias voltages, i.e., 0–300 V. Besides the effect of ICP current, also the effect of various bias frequencies is investigated. It is found that the modulation of the bias power to the spatiotemporal distributions of the ionization rate at 2 MHz is strikingly different from the behavior observed at higher bias frequencies. Furthermore, the minimum of the plasma density appears at different bias voltages, i.e., 120 V at 2 MHz and 90 V at 27.12 MHz.

42 ENGINEERING↗

Fast modulating electron cyclotron emission (FMECE) diagnostic for tokamaks

Utilizing variable-frequency channels, e.g., yttrium iron garnet (YIG) bandpass filters, in the intermediate frequency (IF) section of an electron cyclotron emission (ECE) radiometer facilitates flexibility in the volume viewed by the ECE channels as well as high resolution electron temperature and temperature fluctuation measurements in tokamaks. Fast modulating electron cyclotron emission (FMECE), a stand-alone IF section with eight channels, is a novel application of YIG filters for real-time electron temperature gradient and gradient scale length measurements. Key to FMECE is a simultaneous input/output data acquisition unit, as well as a modified type of YIG filters, which is capable of fast switching of their center (set) frequencies with a frequency slew rate of 600 μs/GHz. A new FMECE has been implemented and tested on the DIII-D tokamak, demonstrating its capability in real-time gradient measurements. Here, the data presented here shows that FMECE can identify flattening in the electron temperature profile; the latter can be used as a sensor for real time monitoring and control of plasma instabilities. Implementation and application are planned for the EAST tokamak.

47 OTHER INSTRUMENTATION↗

Beat-wave Photoinjector for Generating Periodic Electron Bunches at THz Frequencies

A laser beat wave is proposed to induce density modulated electron emission from a photocathode and is thereby used to generate a periodically bunched electron beam from a photocathode electron accelerator. This technique does not introduce additional energy spread or emittance to the electron beam. We also present a laser system for this purpose with a tunable beat frequency up to 40 THz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planck intermediate results. LVI. Detection of the CMB dipole through modulation of the thermal Sunyaev-Zeldovich effect: Eppur si muove II

The largest temperature anisotropy in the cosmic microwave background (CMB) is the dipole, which has been measured with increasing accuracy for more than three decades, particularly with the Planck satellite. The simplest interpretation of the dipole is that it is due to our motion with respect to the rest frame of the CMB. Since current CMB experiments infer temperature anisotropies from angular intensity variations, the dipole modulates the temperature anisotropies with the same frequency dependence as the thermal Sunyaev-Zeldovich (tSZ) effect. Here, we present the first, and significant, detection of this signal in the tSZ maps and find that it is consistent with direct measurements of the CMB dipole, as expected. The signal contributes power in the tSZ maps, which is modulated in a quadrupolar pattern, and we estimate its contribution to the tSZ bispectrum, noting that it contributes negligible noise to the bispectrum at relevant scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Modelling integrated quantum frequency processors towards robust quantum networks

Frequency-encoded quantum information offers intriguing opportunities for quantum communications networks, with the quantum frequency processor (QFP) paradigm promising scalable construction of quantum gates. Yet all experimental demonstrations to date have relied on discrete fiber-optic components that occupy significant physical space and impart appreciable loss. We introduce a model for designing QFPs comprising microring resonator-based pulse shapers and integrated phase modulators. We estimate the performance of frequency-bin Hadamard gates, finding high fidelity values sustained for relatively wide-bandwidth frequency bins. Our simple model and can be extended to other material platforms, providing a design tool for future frequency processors in integrated photonics.

Nussbaum, Benjamin↗

Study of the hyperfine structure of emission lines of I{sub 2} molecules by the method of three-level laser spectroscopy

It is proposed to use narrow optical resonances, corresponding to the hyperfine structure components of emission transitions in I{sub 2}, as frequency references to stabilise laser radiation frequency in the spectral range from 0.8 to 1.3 {mu}m. To obtain such resonances and investigate the hyperfine structure of emission transitions, an experimental setup is built which consists of a saturated absorption laser spectrometer and a three-level laser spectrometer. Excitation is performed by the second harmonic of a cw Nd:YAG laser and probe radiation in the range from 968 to 998 nm is generated by an external cavity diode laser. The radiation beams from both lasers are combined in a cell with iodine vapour, excitation in the cell being performed in the regime of two counterpropagating waves. It is shown that upon phase modulation of exciting radiation, narrow resonances, having the form of the dispersion dependence, appear at the centre of Doppler lines in absorption and emission. These resonances can be used as references to stabilise the laser frequency. The results of the study of the hyperfine structure of emission lines at the (J' = 57, v' = 32) {yields} (J'' = 58, v'' = 48) transition upon excitation at the (J'' = 56, v'' = 0) {yields} (J' = 57, v'' = 32) transition are presented. (laser spectroscopy)

74 ATOMIC AND MOLECULAR PHYSICS↗

A time-to-frequency converter for measuring the shape of short optical pulses

A time-to-frequency converter was constructed using an electro-optic phase modulator as a time lens, allowing the pulse shape in time to be transferred to the frequency domain. We used such a device to record the temporal shape of infrared pulses at a wavelength of 1053 nm (width about 7 ps) and compared these measurements to those made by using both a streak camera and an autocorrelator. This side-by-side comparison illustrates the benefits and limitations of each of the measurement methods. Numerical simulations were used to establish that our time-lens-based system can accurately measure the shape of infrared pulses between 3 ps and 12 ps. We also use our numerical model to determine how such a system can be modified to measure pulses whose width lies in the range of 1–30 ps, a range of interest for the OMEGA-EP laser at the Laboratory for Laser Energetics.

47 OTHER INSTRUMENTATION↗

SILIA: software implementation of a multi-channel, multi-frequency lock-in amplifier for spectroscopy and imaging applications

In this work, we describe a software implementation of a multi-channel, multi-frequency Lock-in Amplifier (SILIA) to extract modulated signals from noisy data distributed over multiple channels of arbitrary number and size. This software implementation emulates the functionality of a multi-channel, multi-frequency lock-in amplifier in a post-processing step following data acquisition. Unlike most traditional lock-in amplifiers, SILIA can work with any number of input channels and is especially useful to analyze data distributed over many channels. We demonstrate the versatility and performance for extracting weak signals in spectroscopy and fluorescence microscopy. We also discuss more general applications and exhibit a method to automatically estimate error from a lock-in result.

47 OTHER INSTRUMENTATION↗

Low-Cost, Highly-Integrated Silicon Carbide (SiC) Multichip Power Modules (MCPMs) for Plug-In Hybrid Electric Vehicles (PHEVs)

A high power (6 kW), efficient (> 95%), ultra-power dense (5.0 kW/L and 3.8 kW/kg), Level 2 isolated on-board vehicular battery charger that utilizes silicon carbide (SiC) power devices for application in electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEVs) was developed. The heart of the charger is a high-frequency capable (> 1 MHz) multi-chip power module allowing for high junction temperature (> 200 °C) operation which, when coupled with a high switching frequency, allows for an order of magnitude increase in power density, while boasting an increase in system efficiency over currently used technologies.

33 ADVANCED PROPULSION SYSTEMS↗

Wave convection regimes in a binary mixture in a modulated gravitational field

Nonlinear wave convection regimes are studied in a horizontal layer of an incompressible binary mixture with anomalous thermal diffusion in the gravitational field modulated with an arbitrary amplitude and finite frequency. Oscillation regimes are numerically simulated by the finite difference method for the case of a layer with impenetrable rigid boundaries, which better corresponds to experimental laboratory conditions. A qualitative difference is found in the dynamics of nonlinear quasi-periodic and subharmonic oscillations appearing in the initially stratified mixture and behaving as modulated and regular standing waves. The dependences of the intensity of convective flows on the modulation amplitude are obtained. The results of nonlinear calculations are compared with data on the boundaries of the equilibrium stability found from the linear theory. It is shown that a region of parameters exists where alternating action suppresses the convective motion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

BL LAC OBJECT PKS B1144-379: AN EXTREME SCINTILLATOR

Rapid variability in the radio flux density of the BL Lac object PKS B1144-379 has been observed at four frequencies, ranging from 1.5 to 15 GHz, with the Very Large Array and the University of Tasmania's Ceduna antenna. Intrinsic and line-of-sight effects were examined as possible causes of this variability, with interstellar scintillation best explaining the frequency dependence of the variability timescales and modulation indices. This scintillation is consistent with a compact source 20-40 {mu}as or 0.15-0.3 pc in size. The inferred brightness temperature for PKS B1144-379 (assuming that the observed variations are due to scintillation) is 6.2 Multiplication-Sign 10{sup 12} K at 4.9 GHz, with approximately 10% of the total flux in the scintillating component. We show that scintillation surveys aimed at identifying variability timescales of days to weeks are an effective way to identify the active galactic nuclei with the highest brightness temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗

A Polarimetric Approach for Constraining the Dynamic Foreground Spectrum for Cosmological Global 21 cm Measurements

The cosmological global (sky-averaged) 21 cm signal is a powerful tool to probe the evolution of the intergalactic medium in high-redshift universe (z⩽6). One of the biggest observational challenges is to remove the foreground spectrum which is at least four orders of magnitude brighter than the cosmological 21 cm emission. Conventional global 21 cm experiments rely on the spectral smoothness of the foreground synchrotron emission to separate it from the unique 21 cm spectral structures in a single total-power spectrum. However, frequency-dependent instrumental and observational effects are known to corrupt such smoothness and complicate the foreground subtraction. We introduce a polarimetric approach to measure the projection-induced polarization of the anisotropic foreground onto a stationary dual-polarized antenna. Due to Earth rotation, when pointing the antenna at a celestial pole, the revolving foreground will modulate this polarization with a unique frequency-dependent sinusoidal signature as a function of time. In our simulations, by harmonic decomposing this dynamic polarization, our technique produces two separate spectra in parallel from the same observation: (i) a total sky power consisting both the foreground and the 21 cm background and (ii) a model-independent measurement of the foreground spectrum at a harmonic consistent to twice the sky rotation rate. In the absence of any instrumental effects, by scaling and subtracting the latter from the former, we recover the injected global 21 cm model within the assumed uncertainty. We further discuss several limiting factors and potential remedies for future implementation.

79 ASTRONOMY AND ASTROPHYSICS↗