Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Exergetic design and analysis of a freeze-out heat exchanger for helium purification

The freeze-out purification process is very effective in removing moisture contamination and can be utilised for purification of helium gas in cryogenic applications. A process model for a freeze-out helium purifier (up to 30 g/s of contaminated helium at 10 ppmv) with a coiled finned-tube heat exchanger is developed. Furthermore, an extensive 1st and 2nd law (exergy) analysis is carried out and the exergetically optimal heat exchanger configuration (diameter and number of flow passes) for a given heat exchanger surface area ranging from 42.5 m 2 to 57.5 m 2 are found.

cryogenics↗

Morphological, Physiological, and Genetic Techniques for Improving Field Identification of Steelhead, Coastal Cutthroat Trout, and Hybrid Smolts

Abstract In streams with sympatric populations of steelhead Oncorhynchus mykiss and coastal cutthroat trout O. clarkii clarkii (hereafter, cutthroat trout), life history descriptions and smolt production estimates may be hampered by misclassification of hybrids as steelhead or cutthroat trout. Additionally, important morphological and physiological differences between hybrid and non-hybird smolts are often unknown. Therefore, we assessed field classification and created classification models to quantify and reduce misclassification rates among migrating steelhead, cutthroat trout, and hybrid smolts. Field misclassifications of smolts with steelhead or cutthroat trout genotypes were low (1% and 2%, respectively). However, field misclassification of fish with hybrid genotypes was high, with 11% of the hybrids being misclassified as steelhead and 42% of the hybrids being misclassified as cutthroat trout. Hybrid smolts were larger, had lower gill Na+, K+-ATPase activities, and lower condition factors than steelhead but were similar to cutthroat trout smolts in these same measurements. Additionally, statistical classification analyses using morphological traits including subterminal jaw slash intensity, hyoid teeth presence, maxillary length, breaks of pigment along outer margin of adipose fin, condition factor, and migration date improved classification error rates of hybrids from 53% to 21%. In systems with sympatric populations of steelhead and cutthroat trout, we recommend a thorough evaluation of field-based identification methods with genetic techniques to assess the effectiveness of field-based classification in addition to examining important life history differences among steelhead, cutthroat trout, and their hybrids.

Kennedy, Benjamen M.↗

Assessment of Barotrauma from Rapid Decompression of Depth-Acclimated Juvenile Chinook Salmon Bearing Radiotelemetry Transmitters

This study investigated the mortality of and injury to juvenile Chinook salmon Oncorhynchus tshawytscha exposed to simulated pressure changes associated with passage through a large Kaplan hydropower turbine. Mortality and injury varied depending on whether a fish was carrying a transmitter, the method of transmitter implantation, the depth of acclimation, and the size of the fish. Juvenile Chinook salmon implanted with radio transmitters were more likely than those without to die or sustain injuries during simulated turbine passage. Gastric transmitter implantation resulted in higher rates of injury and mortality than surgical implantation. Mortality and injury increased with increasing pressure of acclimation. Injuries were more common in subyearling fish than in yearling fish. Gas emboli in the gills and internal hemorrhaging were the major causes of mortality. Rupture of the swim bladder and emphysema in the fins were also common. This research makes clear that the exposure of juvenile Chinook salmon bearing radiotelemetry transmitters to simulated turbine pressures with a nadir of 8-19 kPa can result in barotrauma, leading to immediate or delayed mortality. The study also identified sublethal barotrauma injuries that may increase susceptibility to predation. These findings have significant implications for many studies that use telemetry devices to estimate the survival and behavior of juvenile salmon as they pass through large Kaplan turbines typical of those within the Columbia River hydropower system. Our results indicate that estimates of turbine passage survival for juvenile Chinook salmon obtained with radiotelemetry devices may be negatively biased.

54 ENVIRONMENTAL SCIENCES↗

Open Cell Metal Foam Heat Exchangers for Air-dehumidification Applications

Open cell metal foams have emerged as promising porous materials for various thermal applications such as energy storage and electronics cooling. The physical and mechanical characteristics suggest significant advantages over conventional fin configurations for use in air-cooling heat exchangers. The larger surface area to volume ratio and repetitive cell structure introducing the boundary layer restart and thus enhancing the mixing have been identified as important attributes for such applications. An experimental study has been conducted to evaluate the performance of metal foam heat exchangers under dehumidifying conditions. Closed-loop wind tunnel experiments have been used to determine the pressure drop and heat transfer performance under wet-operating conditions where the parameters such as pore size and upstream face velocity have been varied to understand the potential impact of these parameters.

Nawaz, Kashif↗

Development and assessment of solar-thermal-activated fuel production: Phase 1, summary

Sandia National Laboratories has for many years been engaged in investigating and developing the science and technology of solar thermochemistry for solar fuel applications under the banner “Sunshine to Petrol.” This report summarizes BP‐funded solar thermochemical work performed from November 2011 through May 2012. This “phase one” effort centered on performance mapping of the Counter‐Rotating‐Ring Receiver Reactor Recuperator (CR5) prototype, a thermochemical heat engine for splitting CO 2 (and/or H 2 O) to produce CO (H 2 ) and O 2 . The bulk of the on‐sun testing effort was performed with 8 ceria‐finned rotating rings. During operation, argon is injected into the reduction side of the CR5 while CO 2 is provided to the oxidation side.

Miller, James Edward↗

Task I: Dark Matter Search Experiments with Cryogenic Detectors: CDMS-I and CDMS-II Task II: Experimental Study of Neutrino Properties: EXO and KamLAND

Dark Matter Search - During the period of performance, our group continued the search for dark matter in the form of weakly interacting massive particles or WIMPs. As a key member of the CDMS (Cryogenic Dark Matter Search) collaboration, we completed the CDMS II experiment which led the field in sensitivity for more than five years. We fabricated all detectors, and participated in detector testing and verification. In addition, we participated in the construction and operation of the facility at the Soudan Underground Laboratory and played key roles in the data acquisition and analysis. Towards the end of the performance period, we began operating the SuperCDMS Soudan experiment, which consists of 15 advanced Ge (9 kg) detectors. The advanced detector design called iZIP grew out of our earlier DOE Particle Detector R&D program which demonstrated the rejection of surface electrons to levels where they are no longer the dominant source of background. Our group invented this advanced design and these larger detectors were fabricated on the Stanford campus in collaboration with the SLAC CDMS group and the Santa Clara University group. The sensitivity reach is expected to be up to 5 times better than CDMS II after two years of operation. We will check the new limits on WIMPs set by XENON100, and we expect improved sensitivity for light mass WIMPs beyond that of any other existing experiment. Our group includes the Spokesperson for SuperCDMS and continues to make important contributions to improvements in the detector technology which are enabling the very low trigger thresholds used to explore the low mass WIMP region. We are making detailed measurements of the charge transport and trapping within Ge crystals, measuring the diffusive trapping distance of the quasiparticle excitations within the Al phonon collector fins on the detector surface, and we are contributing to the development of much improved detector Monte Carlos which are essential to guide the detector design and optimize the analysis. Neutrino Physics – In the period of performance the neutrino group successfully completed the construction of EXO-200 and commissioned the detector. Science data taking started on Jun 1, 2011. With the discovery of the 2-neutrino double-beta decay in 136-Xe and the first measurement of the 0-neutrino mode resulting in the most stringent limit of Majorana masses, our group continues to be a leading innovator in the field of neutrino physics which is central to DOE-HEP Intensity Frontier program. The phenomenon of neutrino oscillations, in part elucidated by our earlier efforts with the Palo Verde and KamLAND experiments, provides the crucial information that neutrino masses are non-zero and, yet, it contains no information on the value of the neutrino mass scale. In recent times our group has therefore shifted its focus to a high sensitivity 0-neutrino double beta decay program, EXO. The 0-neutrino double beta decay provides the best chance of extending the sensitivity to the neutrino mass scale below 10 meV but, maybe more importantly, it tests the nature of the neutrino wave function, providing the most sensitive probe for Majorana particles and lepton number violation. The EXO program, formulated by our group several years ago, plans to use up to tonnes of the isotope 136-Xe to study the 0-neutrino double beta decay mode. The EXO-200 detector is the first step in this program and it represents the only large US-led and based experiment taking data. The EXO-200 isotope enrichment program broke new grounds for the enterprise of double beta decay. The detector design and material selection program paid off, resulting in a background that is among the very best in the field. The “first light" of EXO-200 was very exciting with the discovery -in the first month of data- of the rarest 2-neutrino double beta decay mode ever observed. The lower limit on the 0-neutrino double beta decay half-life, published in Phys. Rev. Lett. and based on the first 120 days of data is the second best but, when translated into a Majorana mass scale, it is one of the most stringent constraint we have on neutrino masses. Indeed, such a limit was the first result to contradict a claim of discovery in 76-Ge for most nuclear matrix elements calculations. As we continue data taking and plan some modest upgrades to EXO-200 our group is also very active in the design of nEXO, a 5 tonne detector based on the technology demonstrated by EXO-200. Over the years we have made it a tradition to explore the frontier and not to be shy about looking in new directions and re-inventing ourselves to best take advantage of the precious few opportunities provided by Nature. We have also cultivated a number of young people at all levels and, by now, many of the undergraduates, graduate students and postdocs educated by this group have leading positions in academia and industry around the world.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimizing the design and analysis of cryogenic semiconductor dark matter detectors for maximum sensitivity

In this thesis, we illustrate how the complex E- field geometry produced by interdigitated electrodes at alternating voltage biases naturally encodes 3D fiducial volume information into the charge and phonon signals and thus is a natural geometry for our next generation dark matter detectors. Secondly, we will study in depth the physics of import to our devices including transition edge sensor dynamics, quasi- particle dynamics in our Al collection fins, and phonon physics in the crystal itself so that we can both understand the performance of our previous CDMS II device as well as optimize the design of our future devices. Of interest to the broader physics community is the derivation of the ideal athermal phonon detector resolution and it's T 3 c scaling behavior which suggests that the athermal phonon detector technology developed by CDMS could also be used to discover coherent neutrino scattering and search for non-standard neutrino interaction and sterile neutrinos. These proposed resolution optimized devices can also be used in searches for exotic MeV-GeV dark matter as well as novel background free searches for 8GeV light WIMPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Market Assessment and Commercialization Strategy for the Radial Sandia Cooler

This market assessment and commercialization report characterizes and assesses the market potential of the rotating heat exchanger technology developed at Sandia National Laboratories (SNL), known as the Radial Sandia Cooler. The RSC is a novel, motor-driven, rotating, finned heat exchanger technology. The RSC was evaluated for the residential, commercial, industrial, and transportation markets. Recommendations for commercialization were made based on assessments of the prototype RSC and the Sandia Cooler technology in general, as well as an in-depth analysis of the six most promising products for initial RSC commercialization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Efficiency Low-Cost Solar Receiver for Use Ina a Supercritical CO 2 Recompression Cycle

This project has performed solar receiver designs for two supercritical carbon dioxide (sCO 2 ) power cycles. The first half of the program focused on a nominally 2 MWe power cycle, with a receiver designed for test at the Sandia Solar Thermal Test Facility. This led to an economical cavity-type receiver. The second half of the program focused on a 10 MWe power cycle, incorporating a surround open receiver. Rigorous component life and performance testing was performed in support of both receiver designs. The receiver performance objectives are set to conform to the US DOE goals of 6¢/kWh by 2020 . Key findings for both cavity-type and direct open receiver are highlighted below: A tube-based absorber design is impractical at specified temperatures, pressures and heat fluxes for the application; a plate-fin architecture however has been shown to meet performance and life targets; the $148/kW th cost of the design is significantly less than the SunShot cost target with a margin of 30%; the proposed receiver design is scalable, and may be applied to both modular cavity-type installations as well as large utility-scale open receiver installations; the design may be integrated with thermal storage systems, allowing for continuous high-efficiency electrical production during off-sun hours; costs associated with a direct sCO 2 receiver for a sCO 2 Brayton power cycle are comparable to those of a typical molten salt receiver; lifetimes in excess of the 90,000 hour goal are achievable with an optimal cell geometry; the thermal performance of the Brayton receiver is significantly higher than the industry standard, and enables at least a 30% efficiency improvement over the performance of the baseline steam-Rankine boiler/cycle system; brayton’s patent-pending quartz tube window provides a greater than five-percent efficiency benefit to the receiver by reducing both convection and radiation losses.

14 SOLAR ENERGY↗

An Assessment of Critical Dimension Small Angle X-ray Scattering Metrology for Advanced Semiconductor Manufacturing

Simultaneous migration of planar transistors to FinFET architectures, the introduction of a plurality of materials to ensure suitable electrical characteristics, and the establishment of reliable multiple patterning lithography schemes to pattern sub-10 nm feature sizes imposes formidable challenges to current in-line dimensional metrologies. Because the shape of a FinFET channel cross-section immediately influences the electrical characteristics, the evaluation of 3D device structures requires measurement of parameters beyond traditional critical dimension (CD), including their sidewall angles, top corner rounding and footing, roughness, recesses and undercuts at single nanometer dimensions; thus, metrologies require sub-nm and approaching atomic level measurement uncertainty. Synchrotron critical dimension small angle X-ray scattering (CD-SAXS) has unique capabilities to non-destructively monitor the cross-section shape of surface structures with single nanometer uncertainty and can perform overlay metrology to sub-nm uncertainty. In this dissertation, we perform a systematic experimental investigation using CD-SAXS metrology on a hierarchy of semiconductor 3D device architectures including, high-aspect-ratio contact holes, H2 annealed Si fins, and a series of grating type samples at multiple points along a FinFET fabrication process increasing in structural intricacy and ending with fully fabricated FinFET. Comparative studies between CD-SAXS metrology and other relevant semiconductor dimensional metrologies, particularly CDSEM, CD-AFM and TEM are used to determine physical limits of CD-SAXS approach for advanced semiconductor samples. CD-SAXS experimental tradeoffs, advice for model-dependent analysis and thoughts on the compatibility with a semiconductor manufacturing environment are discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Miniaturized Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant Heat eXchangers (HX) are an essential component of Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems, serving as the main heat transfer component. The major limiting factor to HX performance is the large airside thermal resistance. Recent literature aims at improving heat transfer performance by utilizing enhancement methods such as fins and small tube diameters; this has lead to almost exhaustive research on the microchannel HX (MCHX). The objective of this project is to develop a miniaturized air-to-refrigerant HX with at least 20% reduction in volume, material volume, and approach temperature compared to current state-of-the-art multiport flat tube designs and also be capable of production within five years. Moreover, the proposed HX’s are expected to have good water drainage and should succeed in both evaporator and condenser applications. The project leveraged Parallel-Parametrized Computational Fluid Dynamics (PPCFD) and Approximation-Assisted Optimization (AAO) techniques to perform multi-scale analysis and shape optimization with the intent of developing novel HX designs whose thermal-hydraulic performance exceeds that of state-of-the-art MCHX. Nine heat exchanger geometries were initially chosen for detailed analysis, selected from 35+ geometries which were identified in previous work at the University of Maryland, College Park. The newly developed optimization framework was exercised for three design optimization problems: (DP I) 1.0kW radiator, (DP II) 10kW radiator and (DP III) 10kW two-phase HX. DP I consisted of the design and optimization of 1.0kW air-to-water HX’s which exceeded the project requirements of 20% volume/material reduction and 20% better performance. Two prototypes for the 1.0kW HX were prototyped, tested and validated using newly-designed airside and refrigerant side test facilities. DP II, a scaled version DP I for 10kW air-to-water HX applications, also yielded optimized HX designs which met project requirements. Attempts to prototype a 10kW have presented unique manufacturing challenges, especially regarding tube blockages and structural stability. DP III comprised optimizing two-phase HX’s for a 3.0Ton capacity in a heat pump / air-conditioning unit for cooling mode application using R410A as the working fluid. The HX’s theoretically address the project requirements. System-level analysis showed the HX’s achieved up to 15% improvement in COP while also reducing overall unit charge by 30-40%. The project methodology was capable of developing HX’s which can outperform current state-of-the-art MCHX by at least 20% reduction in volume, material volume, and approach temperature. Additionally, the capability for optimization using refrigerant charge as an objective function was developed. The five-year manufacturing feasibility of the proposed HX’s was shown to have a good outlook. Successful prototyping through both conventional manufacturing methods and next generation methods such as additive manufacturing was achieved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next Generation Nuclear Plant Intermediate Heat Exchanger Acquisition Strategy

DOE has selected the High Temperature Gas-cooled Reactor (HTGR) design for the Next Generation Nuclear Plant (NGNP) Project. The NGNP will demonstrate the use of nuclear power for electricity and hydrogen production. It will have an outlet gas temperature in the range of 900°C to 950°C and a plant design service life of 60 years. The reactor design will be a graphite moderated, helium cooled, prismatic or pebble-bed reactor, and use low-enriched uranium, TRISO-coated fuel. The plant size, reactor thermal power, and core configuration will ensure passive decay heat removal without fuel damage or radioactive material releases during accidents. The NGNP Materials Research and Development (R&D) Program is responsible for performing R&D on likely NGNP materials in support of the NGNP design, licensing, and construction activities. Selection of the technology and design configuration for the NGNP must consider both the cost and risk profiles to ensure that the demonstration plant establishes a sound foundation for future commercial deployments. The NGNP challenge is to achieve a significant advancement in nuclear technology while at the same time setting the stage for an economically viable deployment of the new technology in the commercial sector soon after 2020. The purpose of this report is to address the acquisition strategy for the NGNP Intermediate Heat Exchanger (IHX).This component will be operated in flowing, impure helium on the primary and secondary side at temperatures up to 950°C. There are major high temperature design, materials availability, and fabrication issues that need to be addressed. The prospective materials are Alloys 617, 230, 800H and X, with Alloy 617 being the leading candidate for the use at 950°C. The material delivery schedule for these materials does not pose a problem for a 2018 start up as the vendors can quote reasonable delivery times at the moment. The product forms and amount needed must be finalized as soon as possible. An issue for the fabrication of the IHX pressure and tubular design heat exchanger is the identification of vessel fabrication vendors with the appropriate ASME certifications to perform nuclear work. The number of these firms has declined over the last 20 years and the NGNP will be competing for these services with resurgent orders for LWR’s and chemical process facility components in a world market. The first three designs listed; plate machined heat exchanger (PMHE), plate fin heat exchanger ( PFHE), and the plate stamped heat exchanger (PSHE) are compact heat exchanger designs. The tubular IHX is a standard industrial design. The foam, capillary, and ceramic IHX designs are less mature technologies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High Efficiency Heat Exchanger for High Temperature and High Pressure Applications

CompRex, LLC (CompRex) specializes in the design and manufacture of compact heat exchangers and heat exchange reactors for high temperature and high pressure applications. CompRex’s proprietary compact technology not only increases heat exchange efficiency by at least 25 % but also reduces footprint by at least a factor of ten compared to traditional shell-and-tube solutions of the same capacity and by 15 to 20 % compared to other currently available Printed Circuit Heat Exchanger (PCHE) solutions. As a result, CompRex’s solution is especially suitable for Brayton cycle supercritical carbon dioxide (sCO2) systems given its high efficiency and significantly lower capital and operating expenses. CompRex has already successfully demonstrated its technology and ability to deliver with a pilot-scale compact heat exchanger that was under contract by the Naval Nuclear Laboratory for sCO2 power cycle development. The performance tested unit met or exceeded the thermal and hydraulic specifications with measured heat transfer between 95 to 98 % of maximum heat transfer and temperature and pressure drop values all consistent with the modeled values. CompRex’s vision is to commercialize its compact technology and become the leading provider for compact heat exchangers and heat exchange reactors for various applications including Brayton cycle sCO2 systems. One of the limitations of the sCO2 Brayton power cycle is the design and manufacturing of efficient heat exchangers at extreme operating conditions. Current diffusion-bonded heat exchangers have limitations on the channel size through which the fluid travels, resulting in excessive solid material per heat exchanger volume. CompRex’s design allows for more open area and shorter fluid proximity for increased heat transfer efficiency while sustaining the structural integrity needed for the application. CompRex is developing a novel improvement to its current heat exchanger design where fluids are directed to alternating channels so that each fluid is fully surrounded by the opposing fluid. As compared to similar existing compact heat exchangers, the new design converts most secondary surface area to primary surface area, eliminating fin inefficiencies. CompRex requests that all technical information about the heat exchanger designs be protected as proprietary information. To honor that request, only non-proprietay summaries are included in this report.

47 OTHER INSTRUMENTATION↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications - Design and Simulation Practice to Identify Charge Reduction Opportunities for Residential AC/HP Units

Based on three 5-ton, single-speed heat pumps (HPs), using R-410A, which use the same compressor, indoor blower and outdoor fan, the DOE/ORNL Heat Pump Design Model was used to conduct comparative modelling study. Regarding charge reduction opportunities, in general, we recommend: 1. Downsizing the outdoor condenser will reduce the required system charge, i.e. using smaller tube diameters or fewer tubes; reducing the evaporator inner volume is less important; to offset the reduced condenser tube side surface area, one can increase the air side surface area (fin density) or condenser air flow rate via using a more efficient fan. 2. microchannel heat exchangers are most effective in reducing the required charge, by up to 60% in the condenser and evaporator. To develop low charge systems, one should at least use a microchannel heat exchanger as the outdoor condenser. 3. TXV systems are less sensitive to charge reduction. For the drop-in application, one can decrease the charge to minimize the liquid section in the condenser, at the expense of minor performance degradation; for example, when reducing the system charge by 15% (decrease the subcooling degree to 2R), the simulation results prove that the decrease is less than 3% in the EER and less than 6% in the capacity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending ORNL HPDM Capabilities for Design and Optimization of New Refrigerant Blends – FY18 1st Quarterly Milestone: Perform literature review to collect heat transfer, pressure drop correlations and compressor mapping method for alternative refrigerants

Through a comprehensive literature survey, we identified heat transfer and pressure drop correlations for two-phase evaporation and condensation in fin-and-tube coils using microfin tubes and micro-channel heat exchangers. We also developed a compressor mapping method to convert the maps originally developed for R-22 or R-410A to be used by the alternative lower GWP refrigerants. The correlations and method will be implemented in HPDM for design and optimization of air conditioners and heat pumps using the new refrigerants/blends.

42 ENGINEERING↗

Verification and Validation of the STAT7 Code

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from high enrichment uranium fuel to low enrichment uranium fuel. The key capabilities of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilities are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL_4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow calculations are involved. This problem can be corrected in a later version of the code, however, does not affect the application of STAT7 code as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

BTO 3.1.2.55 Milestone Report – Report of Literature Review for Maldistribution in Heat Exchangers

In this quarter, a comprehensive review of the literature was performed to understand the effects of flow maldistribution and current efforts to improve performance through flow control. Nearly all systems have some degree of maldistribution on either the air-side, refrigerant-side, or both. Air-side maldistribution was found to have a greater impact on heat exchanger performance compared to refrigerant-side, but both sides of the system are important to consider when developing solutions. Up to a maximum of 65% capacity loss was reported in large commercial systems due to air-side maldistribution. Microchannel heat exchangers are becoming more widespread due to their efficiency and size but are even more prone to maldistribution than conventional fin-tube heat exchangers. Current solutions tend to focus on optimizing header design and refrigerant circuitry to improve performance. Several active control methods, such as hybrid control, have been explored to control refrigerant flow in real time, but there is a need for an adaptive yet cost effective system which can optimize performance in changing conditions.

42 ENGINEERING↗

Diesel Engine Waste Heat Driven Absorption Heat Pumps for ECU Applications in Defense Installations

A thermally activated absorption heat pump suitable for use in naval expeditionary Environmental Control Units, as well as residential space-conditioning, is developed. Waste heat characteristic of the exhaust stream from a diesel engine GenSet is used to drive an absorption cycle to provide cooling. The heat source is coupled to the heat pump using an intermediate fluid loop for flexible deployment. With minor modifications, the heat pump could also provide heating at high coefficients of performance, resulting in versatile functionality. This technology capitalizes on heat and mass transfer enhancement possible in microscale passages to provide a compact architecture for the components and the overall system. The working fluid pair with zero Global Warming Potential is contained within this assembly, reducing fluid inventories significantly over conventional systems. Quiet, reliable, long-life operation due to the absence of a compressor and the use of few moving parts are further critical distinguishing advantages. Modularity in cooling capacity has been demonstrated through scaling-up of component geometry and internal features and dimensions. The core technology was initially demonstrated with a proof-of-concept microscale absorption chiller measuring 200 × 200 × 34 mm and weighing 7 kg that delivered 300 W of cooling in laboratory tests. In the previous BEETIT project, the team made significant advances over the proof-of-concept. System and component designs with > 10× scale-up in capacity were developed, in a packaged unit capable of standalone operation with a semi-autonomous control system. A cooling capacity of 3.5 kW with a COP > 0.5 at an ambient temperature of 35°C was demonstrated for this natural gas-fired unit. Significant cost reductions in fabrication were achieved using low-cost brazing instead of diffusion bonding. In companion projects funded by the Southern Company and the Georgia Research Alliance, stamping and fluid forming techniques were investigated to fabricate microscale features instead of photochemical etching, thereby leading to significant cost reductions. In a follow-on effort funded by ARPA-E and NAVFAC, a 2.7 kW cooling unit was developed to provide cooling at a severe ambient condition of 51.7°C. The unit was driven directly by diesel engine exhaust heat. Innovative finned heat and mass exchangers for the ambient-coupled condenser and absorber were developed. In the present effort, a standalone, packaged and controllable 10.5 kW cooling capacity absorption chiller is developed. This demonstrates a 30× scale up from the proof-of-concept, thus validating the scalability of microchannel heat exchangers for absorption heat pumps. Autonomous operation algorithms demonstrated enhanced dynamic performance. The knowledge from previous projects was leveraged to develop novel component designs that further helped in miniaturizing the heat exchangers. All coupling fluids are hydronically coupled to aid flexible field deployment. The prototype unit provides design cooling capacity at high ambient temperature conditions of 44°C at COP > 0.6.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗