The impact of neutron irradiation, graphite oxidation and fluorination on tritium uptake into and desorption from graphite in molten salt environments
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Globally distributed computing infrastructures, such as clouds and supercomputers, are currently used to manage data that is generated with an unprecedented speed from a variety of resources. Coping with this trend, the volume of data exchanged across distant sites increases substantially. To accelerate data transfer, high-speed networks are provided to connect remote sites. Most existing data movement solutions are optimized for moving large files. However, it is still challenging to transfer a large number of small files across networks. This disadvantage not only lowers data transfer performance, but also decreases overall system utilization. Here, we identify that moving small files is mainly constrained by degraded file system throughput, not just network performance as might be suspected. We have built a data transfer pipeline model to analyze the impact of small network I/O and storage I/O on data movement. Extending one of the widely used open source data movement solutions, GridFTP, we demonstrate several appropriate engineering approaches that mitigate the bottleneck and increase data transfer efficiency. We show optimizations that improve data transfer performance more than 5 times. In comparison to existing solutions, our approaches can save a significant amount of system resources for moving lots of small files.
Al-Mg isotope systematics of twelve FeO-poor (type I) chondrules from CR chondrites Queen Alexandra Range 99177 and Meteorite Hills 00426 were investigated by secondary ion mass spectrometry (SIMS). Five chondrules with Mg#’s of 99.0 to 99.2 and Δ 17 O of -4.2‰ to -5.3‰ have resolvable excess 26 Mg. Their inferred ( 26 Al/ 27 Al) 0 values range from (3.5 ± 1.3) × 10 -6 to (6.0 ± 3.9) × 10 -6 . This corresponds to formation times of 2.2 (–0.5/+1.1) Myr to 2.8 (-0.3/+0.5) Myr after CAIs, using a canonical ( 26 Al/ 27 Al) 0 of 5.23 × 10 -5 , and assuming homogeneously distributed 26Al that yielded a uniform initial 26 Al/ 27 Al in the Solar System. Seven chondrules lack resolvable excess 26 Mg. They have lower Mg#’s (94.2 to 98.7) and generally higher Δ 17 O (-0.9‰ to -4.9‰) than chondrules with resolvable excess 26 Mg. Their inferred ( 26 Al/ 27 Al) 0 upper limits range from 1.3 × 10 -6 to 3.2 × 10 -6 , corresponding to formation >2.9 to >3.7 Myr after CAIs. Al-Mg isochrons depend critically on chondrule plagioclase, and several characteristics indicate the chondrule plagioclase is unaltered: (1) SIMS 27 Al/ 24 Mg depth profile patterns match those from anorthite standards, and SEM/EDS of chondrule SIMS pits show no foreign inclusions; (2) transmission electron microscopy (TEM) reveals no nanometer-scale micro-inclusions and no alteration due to thermal metamorphism; (3) oxygen isotopes of chondrule plagioclase match those of coexisting olivine and pyroxene, indicating a low extent of thermal metamorphism; and (4) electron microprobe data show chondrule plagioclase is anorthite-rich, with excess structural silica and high MgO, consistent with such plagioclase from other petrologic type 3.00-3.05 chondrites. We conclude that the resolvable ( 26 Al/ 27 Al) 0 variabilities among chondrules studied are robust, corresponding to a formation interval of at least 1.1 Myr.
Explore the source record for details and available documents.
Copper is a redox variable element that may occur as Cu 0 , Cu + , and Cu 2+ in the Earth’s crust. The oxidation state will affect its partitioning between coexisting minerals, melts and fluids and hence its behaviour in magmatic processes. Copper bearing silicate glasses were quenched from melts with 23 synthetic compositions (19 CaO-Na 2 O-MgO-Al 2 O 3 -SiO 2 (CNMAS), two “granites” containing K 2 O ± H 2 O, and Fe-bearing “MORB” and “andesite”) equilibrated at oxygen fugacities (fO 2 ), expressed in log units relative to the fayalite-magnetite-quartz (FMQ) buffer, ranging from −0.7 to 14, temperatures from 900 to 1500 °C and pressures from 0 to 2.5 GPa. Cu K-edge X-ray absorption near edge structure (XANES) spectra were recorded from the glasses and a pre-edge feature in the XANES spectra was found to scale with the proportion of Cu + . Cu + /ΣCu (where ΣCu = Cu + + Cu 2+ ) was quantified by fitting the intensity of the pre-edge feature as a function of fO 2 to the thermodynamically expected relationship. Cu + /ΣCu was found to only weakly depend on melt composition, with more basic melts (e.g., basalts rather than granites) preferentially stabilising Cu 2+ . Increasing temperature stabilises Cu + , while increasing pressure had little effect on Cu + /ΣCu in CNMAS melts but preferentially stabilised Cu 2+ in granite melts. Cu + /ΣCu can be predicted in silicate melts by the empirical equation: log(Cu 2+ /Cu + ) = 0.25(ΔFMQ + 8.58 − 25050/T + 940P/T – 0.02P) − 4.73 + 5400/T + 1.99Λ + (280P – 90P2) where T is temperature in K, P is pressure in GPa and is the optical basicity of the composition. The effects of fO 2 , melt composition, temperature and pressure on Cu + /ΣCu indicate that Cu + will be the dominant oxidation state in terrestrial silicate melts (e.g., Cu + /ΣCu = 99% in an andesitic melt at 900 °C, 1 GPa and ΔFMQ = 1). The electron exchange reaction Cu 2+ + Fe 2+ → Cu + + Fe 3+ occurs on cooling and, given the abundance of Fe in natural melts, the oxidation state of Cu in natural glasses is unlikely to correspond to that in the original melt.
Not Available
To understand the long-term environmental impact of disposing radioactive waste of in a deep geological repository and to optimise its design, performance assessments are used. In this study, four teams (COVRA, GRS, Quintessa, and DOE) modified the previously developed generic repository of DECOVALEX task F2 to identify commonalities and differences between the teams for specific changes in repository design. The teams tested six design modifications: (1) Replacing concrete abutments with run-of-mine salt; (2) Replacing the salt seal with a concrete abutment and using run-of-mine salt instead for the two concrete abutments in each drift seal; (3) Halving the size of the infrastructure area; (4) Using run-of-mine salt instead of gravel for backfilling the infrastructure area; (5) Disposal of spent nuclear fuel without the POLLUX-10 containers (6); Lower initial saturation of the spent nuclear fuel and vitrified waste disposal drifts. Despite different modelling strategies used, models agreed that a smaller infrastructure area has a limited effect on radionuclide transport. Responses to the absence of the two concrete abutments in each seal, the use of single large concrete abutments (200 m each), or the use of run-of-mine salt in the infrastructure area differ between teams due to differing modelling assumptions. Based on these results, the estimated efficacy of containment depends strongly on the model assumptions of each team. More specifically, it appears to depend on the compaction model used and therefore on the backfill material used in different areas of the repository. However, the drift seal appears to be a critical design element in all models, effectively limiting radionuclide transport by hydrologically disconnecting sections of the repository. Additional beneficial design choices include the use of dry salt in disposal drifts to limit radionuclide transport and reducing the infrastructure area costs and minimizing host rock damage.
Not Available
An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.
The observation of spray-wall interaction is of great importance to understand the dynamics that occur during fuel impingement onto the chamber wall or piston surfaces in internal combustion engines. It is found that the maximum spreading length of an impinged droplet can provide a quantitative estimation of heat transfer and energy transformation for spray-wall interaction. Furthermore, it influences the air-fuel mixing and hydrocarbon and particle emissions at combusting conditions. In this paper, an analytical model of different droplet-wall impingement conditions is developed in terms of βm (dimensionless maximum spreading length, the ratio of maximum spreading length to initial droplet diameter) to understand the detailed impinging dynamic process. These conditions are grouped as: a single diesel droplet impinging on the wall with different inclined angles (α); cold wall - heated droplet and heated wall - cold droplet impingement when inclined angle of the wall is 0°, respectively. The analytical model is built up based on the energy conservation that considers kinetic energy, gravitation energy, and surface energy before impingement, as well as viscous dissipation, gravitation energy, adhesion energy, deformation energy, and heat energy after impingement. The experimental work of diesel droplet impinging on an inclined wall is performed at a certain range of the Weber number (We of 33 to 420) with various inclined angles (α of 0° to 45°), while for inclined angle is 0°, droplet and wall temperature are varied from 25°C to 150°C to study the effects of the inclined angle and temperature on the temporal evolution of the post-impingement characteristics (i.e. droplet spreading length, dynamic contact angle). The analytical model is validated and evaluated at the aforementioned experimental operating points. The validated model can be employed to predict maximum spreading length of the droplet impinged on the wall. It is further utilized to determine the transition from capillary regime to kinetic regime, then to viscous regime at different inclined angle of the wall.
Not Available
Not Available