Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electricity Market”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Energy Arbitrage with Hydrogen: HTSE + Combustion Turbine

The Light Water Reactor Sustainability (LWRS) program seeks to keep Nuclear Power Plants (NPPs) competitive in the changing energy market. The Flexible Plant Operation and Generation (FPOG) pathway investigates Energy Storage Systems (ESS) to give operators an alternative to curtailment or paying to put power on the grid. This work investigates the concept of diverting heat and electricity to High Temperature Steam Electrolysis (HTSE) to produce hydrogen when grid demand is low, storing that hydrogen, then burning it in a combustion turbine to produce zero-emission electricity when grid demand is high. A process model of the combustion turbine was developed in Aspen HYSYS, which was used to complete a parametric analysis and techno-economic analysis.

08 HYDROGEN↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Q1-2024 Solar Cost Benchmarks

Each year, the U.S. Department of Energy’s (DOE) Solar Energy Technologies Office (SETO) and its national laboratory partners develop cost benchmarks for U.S. solar photovoltaic (PV) systems. These benchmarks track progress toward reducing solar costs and guide R&D priorities. Unlike typical studies that report only $/W, SETO uses intrinsic units (e.g., $/m² for mounting structures) to better capture how technology improvements such as module efficiency would impact system costs. This allows flexible modeling where inputs can vary significantly to assess cost sensitivity. Costs are reported in two ways: Minimum Sustainable Price (MSP): Long term, financially viable price under stable market conditions. Modeled Market Price (MMP): Actual market price, influenced by short term distortions such as tariffs or subsidies. Three national labs collect cost data from industry stakeholders, ensuring no duplication in outreach to stakeholders. Data reflects real transactions (primarily from Q1) and is weighted based on the number of sources per cost element. The PV System Cost Model (PVSCM) divides total installed system cost into eight categories: 1. Module (PV) 2. Inverter 3. Energy Storage System (ESS) 4. Structural BOS (SBOS) 5. Electrical BOS (EBOS) 6. Fieldwork 7. Office work 8. Other (developer/EPC costs) The first five are hardware costs, while the last three are soft costs. Each category includes fixed and variable cost components, where “size” depends on context (e.g., manufacturing capacity for modules vs. system capacity for installation costs). Variable costs are expressed using appropriate intrinsic units. The model reflects the owner’s upfront overnight capital cost, excluding tax credits. Tariffs and subsidies are treated as temporary market distortions affecting MMP but not MSP. PVSCM is implemented in Excel, where cost elements are aggregated into total system cost. Additional sheets handle unit conversions and operation & maintenance (O&M), with O&M costs levelized over the system’s lifetime.

14 SOLAR ENERGY↗

LA100 Equity Strategies. Chapter 8: Equitable Rooftop Solar Access and Benefits

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on analysis of customer-sited rooftop solar and storage as a means to reduce electricity bills for low- and moderate-income (LMI) households, multifamily building residents, and renters, who traditionally lack access to bill savings from rooftop solar. Specifically, NREL modeled customer-sited solar and storage adoption using the Distributed Generation Market Demand (dGen™)1 model through 2035 and developed scenarios to identify programs or policies that could support equitable access to bill savings from rooftop solar or solar-plus-storage. Scenarios tested include a direct-install program for LMI customers, net metering for LMI customers, and equitable distribution of benefits from installing solar between owners and renters of renter-occupied buildings. Research was guided by input from the community engagement process, and equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

The Wind Turbine Rotors of the Future: A Research Agenda from the Big Adaptive Rotor Project

This white paper outlines a roadmap to inform future research efforts around the wind turbine rotors of the future. The document is authored by researchers that have been working on the Big Adaptive Rotor (BAR) and related initiatives at the National Renewable Energy Laboratory and Sandia National Laboratories. The Wind Energy Technologies Office of the U.S. Department of Energy has been funding BAR since 2018. The learnings from BAR have been documented in dozens of publications. This new paper identifies unresolved critical challenges in wind turbine rotor technology and structures them in four large topic areas: 1. Predictive and validated numerical tools. 2. Design methods and standards. 3. Improvements in manufacturing. 4. Technological innovations. Although wind turbines have not changed in their core architecture, with the market almost entirely dominated by three-bladed upwind rotors, a vast amount of research has allowed to introduce technological innovations resulting in a reduction in levelized cost of energy that made wind competitive with all traditional sources of electricity. Focusing on the rotor, blades will keep following the trend of mass and stiffness reduction, will adopt segmentation, and will keep growing in length, both land-based and offshore. To support this continuous innovation, this white paper argues that research efforts in rotor technology at the national labs are best directed to the first three topic areas and to low technology-readiness-levels (1-3) innovations, leaving the task of implementing higher-TRL (4-9) technological innovations to industry stakeholders. This research roadmap is also well aligned with the upcoming roadmap defined during the International Energy Agency 109th Topical Expert Meeting on the Grand Challenges of Wind Energy.

17 WIND ENERGY↗

Advanced Oxygen-Free Electrolyzer for Ultra-Low-Cost H 2 Storage for Fossil Plants (Final Technical Report)

DOE’s Office of Fossil Energy and Carbon Management has determined that long-duration energy storage solutions co-located with fossil energy assets offer significant benefits to the fossil industry, electric utilities, and customers. T2M Global has developed an Advanced O 2 -Free Electrolyzer System (AES) Technology for low-cost, long-duration H 2 energy storage for fossil plants. The MW-class AES Module conceptual design aims to upgrade stranded assets (dilute/waste syngas streams, excess electricity, and waste heat) at fossil plants to higher value H 2 for additional revenue and greater sustainability. The H 2 energy storage equips fossil plants with the load following capability needed for the lucrative grid-support services market created by Variable Renewable Energy resources.

08 HYDROGEN↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ni-H2 cell separator matrix engineering

This project was initiated to develop alternative separator materials to the previously used asbestos matrices which were removed from the market for health and environmental reasons. The objective of the research was to find a material or combination of materials that had the following characteristics: (1) resistant to the severe conditions encountered in Ni-H2 cells; (2) satisfactory electrical, electrolyte management, and thermal management properties to function properly; (3) environmentally benign; and (4) capable of being manufactured into a separator matrix. During the course of the research it was discovered that separators prepared from wettable polyethylene fibers along and in combination with potassium titanate pigment performed satisfactory in preliminary characterization tests. Further studies lead to the optimization of the separator composition and manufacturing process. Single ply separator sheets were manufactured with 100 percent polyethylene fibers and also with a combination of polyethylene fibers and potassium titanate pigment (PKT) in the ratio of 60 percent PKT and 40 percent fibers. A pilot paper machine was used to produce the experimental separator material by a continuous, wet laid process. Both types of matrices were produced at several different area densities (grams/sq m).

Scott, W. E.↗

America's Strategy to Secure the Supply Chain for a Robust Clean Energy Transition Factsheet

Demand for clean energy technologies such as wind turbines and batteries for electric vehicles has increased significantly as technology costs have plummeted over the last decade and countries seek to diversify their energy systems with more reliable clean energy sources to lower costs for businesses and consumers. The global clean energy market is expected to grow exponentially — reaching $23 trillion at a minimum by 2030. Without new domestic raw materials production and manufacturing capacity, the U.S. will continue to rely on clean energy imports, exposing the nation to supply chain vulnerabilities while simultaneously losing out on the enormous job opportunities associated with the energy transition. Yet, in many cases, the United States has untapped potential to support greater domestic production.

Source record↗

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ten questions concerning energy flexibility in buildings

Demand side energy flexibility is increasingly being viewed as an essential enabler for the swift transition to a low-carbon energy system that displaces conventional fossil fuels with renewable energy sources while maintaining, if not improving, the operation of the energy system. Building energy flexibility may address several challenges facing energy systems and electricity consumers as society transitions to a low-carbon energy system characterized by distributed and intermittent energy resources. For example, by changing the timing and amount of building energy consumption through advanced building technologies, electricity demand and supply balance can be improved to enable greater integration of variable renewable energy. Although the benefits of utilizing energy flexibility from the built environment are generally recognized, solutions that reflect diversity in building stocks, customer behavior, and market rules and regulations need to be developed for successful implementation. In this paper, we pose and answer ten questions covering technological, social, commercial, and regulatory aspects to enable the utilization of energy flexibility of buildings in practice. In particular, we provide a critical overview of techniques and methods for quantifying and harnessing energy flexibility. We discuss the concepts of resilience and multi-carrier energy systems and their relation to energy flexibility. We argue the importance of balancing stakeholder engagement and technology deployment. Finally, we highlight the crucial roles of standardization, regulation, and policy in advancing the deployment of energy flexible buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pathways of clean energy heating electrification programs for reducing carbon emissions in Northwest China

We report clean energy heating electrification programs provide a promising way to reduce carbon emissions from fossil fuel combustion and consumption. This work studies the cost competitiveness of clean energy heating technologies under three dynamic mechanisms: investment costs, subsidy policies, and operating costs with real data. It provides key insights into the cost competitiveness of the different heating technologies deployed in different areas, as well as their sensitivity to the three dynamic mechanisms. The results show that currently, the distinct heating programs are more cost-efficient in the urban area with existing heating networks. The average payback period of all district clean energy heating programs in the urban area is 14.9 years, while that of the individual clean heating programs is 24.7 years. The individual heating programs are becoming increasingly cost-competitive with the incentive mechanisms, especially the electricity pricing mechanisms. Moreover, individual heating technologies present remarkable advantages on flexibility and sustainability in the long run. According to the technology diffusion model proposed in this paper, the individual clean heating programs will occupy more than 50% of the market share in 2050 under the comprehensive effect of CAPEX, government subsidies, and OPEX. The real-world results and analysis render references to shape the pathway of clean energy heating electrification in Northwest China and other regions with a similar situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Leverage demand-side policies for energy security

Energy security is a top priority for governments, companies, and households because energy systems and the critical functions that they support are threatened by disruptions from wars, pandemics, climate change, and other shocks (1). More often than not, governments rely on policies focused on energy supply to enhance energy security while generally ignoring demand-side possibilities. Further, the indicators traditionally used to measure energy security are also tilted toward the supply side; this fails to capture the full spectrum of vulnerability to energy crises. Energy security assessments need to reflect the wider benefits of security related interventions more accurately. To that end, we develop a systematic approach to measuring the energy security impacts of policy interventions that explicitly considers energy demand (buildings, transport, and industry). Here, we determine that demand-side actions outperform conventional supply-side approaches at making countries more resilient. Energy demand links more directly than supply to the satisfaction of critical social functions and human well-being that are at the core of energy security. Yet, demand-side perspectives tend to be neglected or underrepresented in analysis and policy debates on energy security. Factors that contribute to this supply-side bias include the traditional sectoral organization of industries and policy institutions along fuels (coal, oil, and gas) and energy forms (electric utilities) as well as the decentralized and multivaried activities characteristic of energy demand (from vehicles to household appliances to manufacturing and more), which leads to a multitude of actors and institutional fragmentation. The basic fundamentals of energy systems and markets, where demand and supply are intricately linked, have also not yet risen from vague awareness to a central organizing principle among policy-makers for structuring the energy security discourse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Renewable Energy Potential (reV) Model: A Geospatial Platform for Technical Potential and Supply Curve Modeling

The Renewable Energy Potential (reV) model is a platform for detailed assessment of renewable energy (RE) resources and their geospatial intersection with grid infrastructure and land use characteristics. The reV model currently supports photovoltaic (PV), concentrating solar power (CSP) and land-based wind turbine technologies. Modules in the reV framework function at different spatial and temporal resolutions, allowing for assessment of resource potential, technical potential and supply curves at varying levels of detail. The platform runs on NREL's High Performance Computing system, providing scalable and efficient performance from a single location all the way up to continental scales, for a single year or decades of time series resource data. Coupled with NREL's System Advisor Model (SAM), reV supports resource assessment from 5-minute to hourly temporal resolution and provides for analysis of long-term (i.e., year-on-year) variability of RE generation (e.g., interannual variability and exceedance probabilities). Technical potential is measured as a function of resource potential and limitations put on developable land area defined by the user. For example, the user can limit development by land ownership, terrain, land use/cover, and urban areas, as well as custom inputs. Technology, grid interconnection and operation costs, based on the latest market data and future projections, are also embedded in the model. The supply curve module is a spatial sorting algorithm based on plant siting, grid interconnection cost, and regional competition, which provides a geographically discrete estimate of levelized cost of electricity (LCOE) and supply (i.e., capacity) for specific renewable technologies. The reV model currently provides broad coverage across North America, South and Central Asia, South America and South Africa to inform national- and international-scale analyses as well as regional infrastructure and deployment planning.

13 HYDRO ENERGY↗

U.S. DOE Southeast Combined Heat and Power Technical Assistance Partnership

During the five-year period from September 2018 to December 2023, the Industrial Efficiency and Decarbonization office (IEDO) of the U.S. Department of Energy (DOE) funded the Southeast Combined Heat and Power Technical Assistance Partnership (Southeast CHP TAP), managed the NC Clean Energy Technology Center located at NC State University (NCSU). The Southeast CHP TAP was one of ten regional CHP TAPs established to promote and assist in transforming the market for combined heat and power (CHP) and related technologies, including district energy (DE) and waste heat to power (WHP) throughout the United States. CHP, also known as cogeneration, is an efficient and clean approach to generating on-site electric power and useful thermal energy from a single fuel source.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing Helicopter Pilots’ Detect and Avoid and Collision Avoidance Performance With ACAS Xr

The latest variant of the Federal Aviation Administration’s Airborne Collision Avoidance System (ACAS X) is being designed for both crewed and uncrewed rotorcraft. Referred to as ACAS Xr, the system joins a suite of other ACAS X variants poised to replace the Traffic Alert and Collision Avoidance System (TCAS II). ACAS Xr is tuned to support current-day helicopter platforms as well as electric Vertical Takeoff and Landing (eVTOL) vehicles that are still under development. Given this flexibility, ACAS Xr may be used by helicopter crews currently in operation or by remotely-operated eVTOL aircraft in the emerging Advanced Air Mobility (AAM) market. To cover the range of potential uses, two distinct configurations are being proposed for ACAS Xr: Collision Avoidance System (CAS) and Detect and Avoid (DAA). Under the CAS configuration, ACAS Xr provides minimal caution-level alerting but issues directive warning-level alerting and guidance. The DAA configuration, by contrast, provides caution-level alerting and guidance, in addition to the warning-level alerting and guidance. The current study was performed as part of the National Aeronautics and Space Administration’s AAM project. Six helicopter pilots were recruited to fly a variety of scripted traffic scenarios in a full-motion, crewed eVTOL simulator. Participants flew 60 encounters over two days, reacting to pre-recorded intruder aircraft that were scripted to fly into the participant’s aircraft from different approach angles, relative altitudes, and during different phases of flight. The pilots flew half of the encounters with the CAS configuration and half with the DAA configuration. Within each block of 30 encounters, pilots experienced 10 conflicts while in cruise, 10 in hover, and 10 while on approach to a heliport. Results showed that pilot response times were consistently under 5 seconds for RAs and under 10 seconds for DAA alerts, when present, during all three phases of flight. Unsurprisingly, the DAA configuration was associated with lower rates of en-route and high-severity losses of DAA well clear compared to the CAS configuration in all phases of flight except for the terminal area. Rates of losses of DAA well clear were found to be substantially higher in the Hover scenario, compared to Cruise. Pilots failed to fully comply with RAs at a rate of 0.10-0.18 in all conditions except for the DAA configuration in the Hover scenario, which was associated with a higher non-compliance rate of 0.4 due to Descend RAs issued at low altitudes. The implications of these results with regards to the ongoing development of ACAS Xr is discussed.

air taxis↗

Assessing Helicopter Pilots’ Detect and Avoid and Collision Avoidance Performance with ACAS Xr

The latest variant of the Federal Aviation Administration’s Airborne Collision Avoidance System (ACAS X) is being designed for both crewed and uncrewed rotorcraft. Referred to as ACAS Xr, the system joins a suite of other ACAS X variants poised to replace the Traffic Alert and Collision Avoidance System (TCAS II). ACAS Xr is tuned to support current-day helicopter platforms as well as electric Vertical Takeoff and Landing (eVTOL) vehicles that are still under development. Given this flexibility, ACAS Xr may be used by helicopter crews currently in operation or by remotely-operated eVTOL aircraft in the emerging Advanced Air Mobility (AAM) market. To cover the range of potential uses, two distinct configurations are being proposed for ACAS Xr: Collision Avoidance System (CAS) and Detect and Avoid (DAA). Under the CAS configuration, ACAS Xr provides minimal caution-level alerting but issues directive warning-level alerting and guidance. The DAA configuration, by contrast, provides caution-level alerting and guidance, in addition to the warning-level alerting and guidance. The current study was performed as part of the National Aeronautics and Space Administration’s AAM project. Six helicopter pilots were recruited to fly a variety of scripted traffic scenarios in a full-motion, crewed eVTOL simulator. Participants flew 60 encounters over two days, reacting to pre-recorded intruder aircraft that were scripted to fly into the participant’s aircraft from different approach angles, relative altitudes, and during different phases of flight. The pilots flew half of the encounters with the CAS configuration and half with the DAA configuration. Within each block of 30 encounters, pilots experienced 10 conflicts while in cruise, 10 in hover, and 10 while on approach to a heliport. Results showed that pilot response times were consistently under 5 seconds for RAs and under 10 seconds for DAA alerts, when present, during all three phases of flight. Unsurprisingly, the DAA configuration was associated with lower rates of en-route and high-severity losses of DAA well clear compared to the CAS configuration in all phases of flight except for the terminal area. Rates of losses of DAA well clear were found to be substantially higher in the Hover scenario, compared to Cruise. Pilots failed to fully comply with RAs at a rate of 0.10-0.18 in all conditions except for the DAA configuration in the Hover scenario, which was associated with a higher non-compliance rate of 0.4 due to Descend RAs issued at low altitudes. The implications of these results with regards to the ongoing development of ACAS Xr is discussed.

air taxis↗

Modeling and Analysing the Impact of Heat Pump Water Heaters on Distribution Systems Using GridLAB-D

With the constant increase in energy demand, finding ways to reduce peak load and the energy-costs factors has become more imperative. Domestic water heating showcases a significant opportunity for such applications. Water heating is the second-highest energy consumer in the residential sector across the United States. Electric Water Heaters (EWHs), in particular, constitute nearly 43% of American household water heating energy consumption. Heat Pump Water Heater (HPWH), on the other hand, are an advanced water heating technology that has recently emerged in the United States residential market. The objectives of this work are to develop a HPWH model and build a case study that evaluates various penetration levels of HPWH in providing reduced peak load and cost-effective energy savings for both utilities and customers. The HPWH model was developed and integrated within the GridLAB-D simulation environment. The model behavior was then validated against a real HPWH unit at Portland State University (PSU). The case studies incorporated five HPWH penetration levels, ranging from 20% to 100%. In each case, EWHs were replaced with HPWHs. The results showed that a high penetration level of HPWHs can reduce the energy consumption on a distribution system to 38%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗