Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Patient Dose Reference Levels for Interventional Radiology: A National Approach

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm{sup 2} for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm{sup 2} for lower limb arteriography (685 cases), 89 Gy cm{sup 2} for renal arteriography (55 cases), 80 Gy cm{sup 2} for biliary drainage (205 cases), 289 Gy cm{sup 2} for hepatic chemoembolization (151 cases), 94 Gy cm{sup 2} for iliac stent (70 cases), and 236 Gy cm{sup 2} for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new method for the preparation of a Fe{sub 3}O{sub 4}/graphene hybrid material and its applications in electromagnetic wave absorption

Graphical abstract: A microwave-assisted solvothermal process was used to prepare Fe{sub 3}O{sub 4} nanoparticles/graphene hybrids, which could be applied as an electromagnetic (EM) radiation absorbent. The absorber, composed of 20 wt% Fe{sub 3}O{sub 4}/graphene–epoxy, exhibited a dual-frequency reflection characteristic covering the C and Ku bands with maximum reflection losses of less than −20 dB at thicknesses of 4 and 5 mm. - Highlights: • Fe{sub 3}O{sub 4}/graphene composites were prepared by a microwave-assisted solvothermal route. • Uniform loading of Fe{sub 3}O{sub 4} nanoparticles on graphene was obtained. • The products as-synthesized show great promise as a microwave absorption material. • Synergistic effects of Fe{sub 3}O{sub 4} and graphene caused improved absorption efficiency. • The Fe{sub 3}O{sub 4}/graphene product possessed a dual-frequency reflection characteristic. - Abstract: A rapid, simple, and inexpensive process combining a microwave-assisted technique and a solvothermal method has been developed using graphene sheets and FeCl{sub 3}·6H{sub 2}O as the reactant to prepare graphene/Fe{sub 3}O{sub 4} nanoparticle hybrids, which can be applied as an electromagnetic radiation absorbent. The experimental factors (i.e., composition ratio, microwave power, and irradiation time) on the products’ characteristics were examined. Under optimal conditions, the morphological analysis revealed that the graphene sheet was homogeneously covered with Fe{sub 3}O{sub 4} nanoparticles (∼50 nm). The electromagnetic parameters of the composites made from 20 wt% Fe{sub 3}O{sub 4}/graphene–epoxy were measured by a vector network analyzer. It was found that the 4- and 5 mm-thick composites could attain a reflection loss below −20 dB in the dual-ranges of 4–8 and 12–18 GHz.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microwave absorption behavior and electromagnetic properties of Ni-Zr doped La-Sr hexagonal ferrite synthesized by auto-combustion method

Highlights: • Quantitative analysis of Microwave Absorption for synthesized ferrites. • Maximum absorption was successfully predicted from quarter-wavelength method. • Minimum RL = −25.07 dB with 1.25 GHz bandwidth for composition x = 0.75. • Better gross loss tangent and Microwave Absorption in Ku-band. • Synthesized ferrites can be used as thin or thick sheet of microwave absorber. - Abstract: Strontium hexagonal ferrites with compositional formula Sr{sub 0.85}La{sub 0.15}(NiZr){sub x}Fe{sub 12-2x}O{sub 19}, where ‘x’ varies from 0.00 to 1.00 in steps of 0.25, were synthesized by auto-combustion method. Structural, magnetic, electromagnetic and microwave absorption properties of synthesized ferrites were studied. The vector network analyzer (VNA) was used to measure complex permittivity (ε′–jε′′) and complex permeability (μ′–jμ′′) in X-band (8–12.4 GHz) and Ku-band (12.4–18 GHz) frequency range. The minimum reflection loss curves were obtained using back metal plate method for analyzing absorption properties of the material. All the synthesized ferrites show maximum absorption in Ku-band for sample thickness in the range of 1.6–1.68 mm. These newly synthesized ferrites have great potential to be used as thin microwave absorber sheets with minimum reflection loss values in the range of –19.69 dB to −27.8 dB and bandwidth in the range of 680 MHz–1.25 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

INFRARED IMAGING OF CARBON AND CERAMIC COMPOSITES: DATA REPRODUCIBILITY

Infrared NDE techniques have proven to be superior for imaging of flaws in ceramic matrix composites (CMC) and carbon silicon carbide composites (C/SiC). Not only can one obtain accurate depth gauging of flaws such as delaminations and layered porosity in complex-shaped components such as airfoils and other aeronautical components, but also excellent reproducibility of image data is obtainable using the STTOF (Synthetic Thermal Time-of-Flight) methodology. The imaging of large complex shapes is fast and reliable. This methodology as applied to large C/SiC flight components at the NASA Dryden Flight Research Center will be described.

36 MATERIALS SCIENCE↗

Elementary Ion Optics with Applications to Electromagnetic Spectrometers

This lecture, intended for physics graduate students, represents an introduction to ion optics with applications to the electromagnetic spectrometers used in nuclear astrophysics research. A particular radiative capture reaction is chosen to illustrate the requirements of such spectrometers.

43 PARTICLE ACCELERATORS↗

TESTING OF NB{sub 3}SN QUADRUPOLE COILS USING MAGNETIC MIRROR STRUCTURE

This paper describes the design and parameters of a quadrupole mirror structure for testing the mechanical, thermal and quench performance of single shell-type superconducting quadrupole coils at field, current and force levels similar to that of real magnet. The concept was experimentally verified by testing two quadrupole coils, previously used in quadrupole models, in the developed mirror structure in the temperature range from 4.5 to 1.9 K. The coils were instrumented with voltage taps, heaters, and strain gauges to monitor their mechanical and thermal properties and quench performance. A new quadrupole coil made of improved Nb{sub 3}Sn RRP-108/127 strand and cable insulation based on E-glass tape was also tested using this structure. The fabrication and test results of the quadrupole mirror models are reported and discussed.

36 MATERIALS SCIENCE↗

Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution

To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Lab-based Ultrafast Molecular Structure

The proliferation of various laser-driven approaches to sub-picosecond hard X-ray and short-wavelength radiation generation in the past few decades has opened many avenues for the laboratory-based development of traditionally facility-based short wavelength ultrafast molecular structure science. Together with the introduction of microcalorimeter detection schemes, this opens the floodgates to widespread, decentralized implementation of what were until recently specialist short wavelength techniques. A parallel situation exists for the contemporary adoption of sub-wavelength resolution optical microscopies. In what follows, a few ultrafast molecular structure developments and their rationale are briefly recounted.

74 ATOMIC AND MOLECULAR PHYSICS↗

Recent results from WASA-at-COSY

WASA--a 4{pi} spectrometer for detection of charged and neutral particles--started operation at the cooler synchrotron COSY-Juelich in 2007. A number of experiments on meson production and decays have been carried out since then. The status of the analysis and preliminary results of some selected topics from the physics program are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dipole Excitation With A Paul Ion Trap Mass Spectrometer

Preliminary results are presented for the use of an auxiliary radiofrequency (rf) excitation voltage in combination with a high purity, high voltage rf generator to perform dipole excitation within a high precision Paul ion trap. These results show the effects of the excitation frequency over a continuous frequency range on the resultant mass spectra from the Paul trap with particular emphasis on ion ejection times, ion signal intensity, and peak shapes. Ion ejection times are found to decrease continuously with variations in dipole frequency about several resonant values and show remarkable symmetries. Signal intensities vary in a complex fashion with numerous resonant features and are driven to zero at specific frequency values. Observed intensity variations depict dipole excitations that target ions of all masses as well as individual masses. Substantial increases in mass resolution are obtained with resolving powers for nitrogen increasing from 114 to 325.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lessons Learned In Developing The VACIS Products

SAIC's development of VACIS provides useful 'lessons learned' in bridging the gap from an idea to a security or contraband detection product. From a gamma densitometer idea for solving a specific Customs Service (CS) requirement (detection of drugs in near-empty tanker trucks) in mid-1990's, SAIC developed a broad line of vehicle and cargo inspections systems (over 500 systems deployed to date) based on a gamma-ray radiographic imaging technique. This paper analyzes the reasons for the successful development of VACIS and attempts to identify ''lessons learned'' useful for future security and contraband detection product developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Energy Nanoscale-Resolution X-ray Microscopy Based on Refractive Optics on a Long Beamline

The long length and good coherence properties of ID11 at the ESRF have led to the development of x-ray microscopy based on compound refractive lenses (CRLs). For the highest resolution full-field microscopy, the sample is placed {approx}40 m from the source, which can be micro-focused by a transfocator as a condenser. Due to the long length of the beamline and consequent long sample-detector distance, a CRL objective can be placed up to a meter behind the sample and still allow for magnification of 60x on a detector located at 99 m--enough to achieve easily 100-nm resolution with a typical high-resolution detector.

07 ISOTOPE AND RADIATION SOURCES↗

Magnetoabsorption and radiation-induced resistance oscillations in two-dimensional electron systems

Magnetoabsorption and resistance oscillations in two-dimensional systems are calculated in the framework of the same theory: the microwave driven Larmor orbit model. On the one hand, this theory allows to obtain resistance oscillations with multiple peaks, depending on the microwave frequency. On the other hand, it permits also to calculate the microwave magnetoabsorption..

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Velocity-space signatures of shock-drift acceleration at quasi-perpendicular collisionless shocks

The shock-drift acceleration of ions at quasi-perpendicular shocks is a well-known kinetic mechanism for the acceleration of a small fraction of incoming ions to high energy. Here, we use a suite of sixteen hybrid simulations of quasi-perpendicular collisionless shocks over the range of Alfvén Mach number 4.3 ≤ M A ≤ 15.8 (corresponding to a range of fast magnetosonic Mach numbers 2.6 ≤ M f ≤ 9.4) and shock-normal angle 45°≤ θ Bn ≤ 90° to identify the velocity-space signature of shock-drift acceleration using the field-particle correlation technique. We show that the features of the ion velocity distribution in the shock foot and ramp regions can be clearly interpreted by analysis of the single-particle trajectory of a reflected ion through the full 3D-3V phase space. The characteristic features of the velocity-space signature of shock-drift acceleration remain qualitatively robust over the full parameter range of our simulations, providing a potential means for its identification using single-point spacecraft measurements. At higher Alfvén Mach numbers M A ≳8 (M f ≳5), kinetic instabilities generate fluctuations of the electromagnetic fields within the shock transition region, leading to fluctuations in and smearing out of the resulting velocity-space signatures, but the signature remains generally robust and identifiable. The results on the shock-drift acceleration of ions presented here represent a novel means to determine more completely the partitioning of upstream bulk flow kinetic energy into plasma heating, particle acceleration, and electromagnetic fields in collisionless shocks.

Howes, Gregory G. [Univ. of Iowa, Iowa City, IA (U↗

Asymmetrisation of the profile of a thin dynamic holographic grating in a TV-locked optical feedback loop

A system for recording a dynamic holographic grating in an optically addressed liquid-crystal spatial light modulator is studied. The system provides the asymmetrisation of the grating profile by using a TV-locked optical feedback loop (nonlinear or adaptive interferometer). (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE ABUNDANCE PATTERN IN THE HOT ISM OF NGC 4472: INSIGHTS AND ANOMALIES

Important clues to the chemical and dynamical history of elliptical galaxies are encoded in the abundances of heavy elements in the X-ray emitting plasma. We derive the hot interstellar medium abundance pattern in inner (0-2.3 R{sub e}) and outer (2.3-4.6R{sub e}) regions of NGC 4472 from analysis of Suzaku spectra, supported by analysis of co-spatial XMM-Newton spectra. The low background and relatively sharp spectral resolution of the Suzaku X-ray Imaging Spectrometer detectors, combined with the high luminosity and temperature in NGC 4472, enable us to derive a particularly extensive abundance pattern that encompasses O, Ne, Mg, Al, Si, S, Ar, Ca, Fe, and Ni in both regions. We apply simple chemical evolution models to these data and conclude that the abundances are best explained by a combination of {alpha}-element enhanced stellar mass loss and direct injection of Type Ia supernova (SNIa) ejecta. We thus confirm the inference, based on optical data, that the stars in elliptical galaxies have supersolar [{alpha}/Fe] ratios, but find that that the present-day SNIa rate is {approx}4-6 times lower than the standard value. We find SNIa yield sets that reproduce Ca and Ar, or Ni, but not all three simultaneously. The low abundance of O relative to Ne and Mg implies that standard core collapse nucleosynthesis models overproduce O by {approx}2.

79 ASTRONOMY AND ASTROPHYSICS↗

SUPERNOVA 2009kf: AN ULTRAVIOLET BRIGHT TYPE IIP SUPERNOVA DISCOVERED WITH PAN-STARRS 1 AND GALEX

We present photometric and spectroscopic observations of a luminous Type IIP Supernova (SN) 2009kf discovered by the Pan-STARRS 1 (PS1) survey and also detected by the Galaxy Evolution Explorer. The SN shows a plateau in its optical and bolometric light curves, lasting approximately 70 days in the rest frame, with an absolute magnitude of M{sub V} = -18.4 mag. The P-Cygni profiles of hydrogen indicate expansion velocities of 9000 km s{sup -1} at 61 days after discovery which is extremely high for a Type IIP SN. SN 2009kf is also remarkably bright in the near-ultraviolet (NUV) and shows a slow evolution 10-20 days after optical discovery. The NUV and optical luminosity at these epochs can be modeled with a blackbody with a hot effective temperature (T {approx} 16,000 K) and a large radius (R {approx} 1 x 10{sup 15} cm). The bright bolometric and NUV luminosity, the light curve peak and plateau duration, the high velocities, and temperatures suggest that 2009kf is a Type IIP SN powered by a larger than normal explosion energy. Recently discovered high-z SNe (0.7 < z < 2.3) have been assumed to be IIn SNe, with the bright UV luminosities due to the interaction of SN ejecta with a dense circumstellar medium. UV-bright SNe similar to SN 2009kf could also account for these high-z events, and its absolute magnitude M{sub NUV} = -21.5 {+-} 0.5 mag suggests such SNe could be discovered out to z {approx} 2.5 in the PS1 survey.

79 ASTRONOMY AND ASTROPHYSICS↗

TRANSMISSION AND EMISSION OF SOLAR ENERGETIC PARTICLES IN SEMI-TRANSPARENT SHOCKS

While major solar energetic particle (SEP) events are associated with coronal mass ejection (CME)-driven shocks in solar wind, accurate SEP measurements reveal that more than one component of energetic ions exist in the beginning of the events. Solar electromagnetic emissions, including nuclear gamma-rays, suggest that high-energy ions could also be accelerated by coronal shocks, and some of those particles could contribute to SEPs in interplanetary space. However, the CME-driven shock in solar wind is thought to shield any particle source beneath the shock because of the strong scattering required for the diffusive shock acceleration. In this Letter, we consider a shock model that allows energetic particles from the possible behind-shock source to appear in front of the shock simultaneously with SEPs accelerated by the shock itself. We model the energetic particle transport in directions parallel and perpendicular to the magnetic field in a spherical shock expanding through the highly turbulent magnetic sector with an embedded quiet magnetic tube, which makes the shock semi-transparent for energetic particles. The model energy spectra and time profiles of energetic ions escaping far upstream of the shock are similar to the profiles observed during the first hour of some gradual SEP events.

79 ASTRONOMY AND ASTROPHYSICS↗