Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Fermi GBM Observations of LIGO Gravitational-Wave Event Gw150914

With an instantaneous view of 70% of the sky, the Fermi Gamma-ray Burst Monitor (GBM) is an excellent partner in the search for electromagnetic counterparts to gravitational-wave (GW) events. GBM observations at the time of the Laser Interferometer Gravitational-wave Observatory (LIGO) event GW150914 reveal the presence of a weak transient above 50 keV, 0.4 s after the GW event, with a false-alarm probability of 0.0022 (2.9(sigma)). This weak transient lasting 1 s was not detected by any other instrument and does not appear to be connected with other previously known astrophysical, solar, terrestrial, or magnetospheric activity. Its localization is ill-constrained but consistent with the direction of GW150914. The duration and spectrum of the transient event are consistent with a weak short gamma-ray burst (GRB) arriving at a large angle to the direction in which Fermi was pointing where the GBM detector response is not optimal. If the GBM transient is associated with GW150914, then this electromagnetic signal from a stellar mass black hole binary merger is unexpected. We calculate a luminosity in hard X-ray emission between 1 keV and 10 MeV of 1.8(sup +1.5, sub -1.0) x 10(exp 49) erg/s. Future joint observations of GW events by LIGO/Virgo and Fermi GBM could reveal whether the weak transient reported here is a plausible counterpart to GW150914 or a chance coincidence, and will further probe the connection between compact binary mergers and short GRBs.

gamma-ray burst: general – gravitational waves↗

Detecting excess ionizing radiation by electromagnetic breakdown of air

A scheme is proposed for detecting a concealed source of ionizing radiation by observing the occurrence of breakdown in atmospheric air by an electromagnetic wave whose electric field surpasses the breakdown field in a limited volume. The volume is chosen to be smaller than the reciprocal of the naturally occurring concentration of free electrons. The pulse duration of the electromagnetic wave must exceed the avalanche breakdown time (10-200 ns) and could profitably be as long as the statistical lag time in ambient air (typically, microseconds). Candidate pulsed electromagnetic sources over a wavelength range, 3 mm>{lambda}>10.6 {mu}m, are evaluated. Suitable candidate sources are found to be a 670 GHz gyrotron oscillator with 200 kW, 10 {mu}s output pulses and a Transversely Excited Atmospheric-Pressure (TEA) CO{sub 2} laser with 30 MW, 100 ns output pulses. A system based on 670 GHz gyrotron would have superior sensitivity. A system based on the TEA CO{sub 2} laser could have a longer range >100 m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental Verification of NASA’s Europa Clipper Mission

NASA’s Jet Propulsion Laboratory (JPL) and its partner are planning a mission to explore an icy moon of Jupiter, Europa. The objective of the planned Europa Clipper mission is to gain insight into the key ingredients for this potentially habitable world. This mission will conduct investigations using a suite of remote sensing and in-situ fields and particles instruments, and a two-channel ice-penetrating radar. Among its science objectives are to produce high-resolution images of Europa's surface, determine its composition, look for signs of recent or ongoing activity, measure the thickness of the ice shell, search for subsurface lakes, and determine the depth and salinity of Europa's ocean. Europa Clipper is expected to encounter very challenging environments. These environments include radiation, dynamics, thermal, and electromagnetics, which have been translated into a set of environmental requirements that are levied onto the Europa Clipper flight system design. This paper describes how the environmental requirements are specified and verified for each flight component and at which level of integration. A couple of examples will be provided to illustrate the process by which a comprehensive set of verification activities is specified and performed for individual subsystems and instruments to ensure mission success.

Man, Kin Fung↗

An ECT/ERT dual-modality sensor for oil-water two-phase flow measurement

This paper presents a new sensor for ECT/ERT dual-modality system which can simultaneously obtain the permittivity and conductivity of the materials in the pipeline. Quasi-static electromagnetic fields are produced by the inner electrodes array sensor of electrical capacitance tomography (ECT) system. The results of simulation show that the data of permittivity and conductivity can be simultaneously obtained from the same measurement electrode and the fusion of two kinds of data may improve the quality of the reconstructed images. For uniform oil-water mixtures, the performance of designed dual-modality sensor for measuring the various oil fractions has been tested on representative data and the results of experiments show that the designed sensor broadens the measurement range compared to single modality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cryogenic target for Compton scattering experiments at HIγS

We have developed a cryogenic target for use at the High Intensity γ-ray Source (HIγS). The target system is able to liquefy 4He at 4 K, hydrogen at 20 K, and deuterium at 23 K to fill a 0.3 L Kapton cell. Liquid temperatures and condenser pressures are recorded throughout each run in order to ensure that the target's areal density is known to ~1%. The target is being utilized in a series of experiments which probe the electromagnetic polarizabilities of the nucleon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analyzing the Radiation Properties of High-Z Impurities in High-Temperature Plasmas

Most tokamak-based reactor concepts require the use of noble gases to form either a radiative mantle or divertor to reduce conductive heat exhaust to tolerable levels for plasma facing components. Predicting the power loss necessary from impurity radiation is done using electron temperature-dependent 'cooling-curves' derived from ab initio atomic physics models. We present here a technique to verify such modeling using highly radiative, argon infused discharges on Alcator C-Mod. A novel x-ray crystal imaging spectrometer is used to measure spatially resolved profiles of line-emissivity, constraining impurity transport simulations. Experimental data from soft x-ray diodes, bare AXUV diodes and foil bolometers are used to determine the local emissivity in three overlapping spectral bands, which are quantitatively compared to models. Comparison of broadband measurements show agreement between experiment and modeling in the core, but not over the entire profile, with the differences likely due to errors in the assumed radial impurity transport outside of the core. Comparison of Ar{sup 16+} x-ray line emission modeling to measurements suggests an additional problem with the collisional-radiative modeling of that charge state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Glow plasma trigger for electron cyclotron resonance ion sources

Electron cyclotron resonance ion sources (ECRISs) are particularly useful for nuclear, atomic, and high energy physics, as unique high current generators of multicharged ion beams. Plasmas of gas discharges in an open magnetic trap heated by pulsed (100 {mu}s and longer) high power (100 kW and higher) high-frequency (greater than 37.5 GHz) microwaves of gyrotrons is promising in the field of research in the development of electron cyclotron resonance sources for high charge state ion beams. Reaching high ion charge states requires a decrease in gas pressure in the magnetic trap, but this method leads to increases in time, in which the microwave discharge develops. The gas breakdown and microwave discharge duration becomes greater than or equal to the microwave pulse duration when the pressure is decreased. This makes reaching the critical plasma density initiate an electron cyclotron resonance (ECR) discharge during pulse of microwave gyrotron radiation with gas pressure lower than a certain threshold. In order to reduce losses of microwave power, it is necessary to shorten the time of development of the ECR discharge. For fast triggering of ECR discharge under low pressure in an ECRIS, we initially propose to fill the magnetic trap with the plasmas of auxiliary pulsed discharges in crossed ExB fields. The glow plasma trigger of ECR based on a Penning or magnetron discharge has made it possible not only to fill the trap with plasma with density of 10{sup 12} cm{sup -3}, required for a rapid increase in plasma density and finally for ECR discharge ignition, but also to initially heat the plasma electrons to T{sub e}{approx_equal}20 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Organic Scintillators for Neutron Detection

This paper present the current work on neutron detection in Soltan Institute for Nuclear Studies. Lately, we have focused our research on the development of new organic scintillators including liquid scintillators for neutron detection and associated measurements. We measured liquid scintillators (also {sup 10}B-doped for thermal neutron detection){sup 3}He tubes, composites, etc. Response of the following detectors on thermal neutrons, fast neutrons and gamma radiation - the pulse shape discrimination (PSD)- has been mainly performed by means of a zero-crossing (ZC) method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconciling FTIR Spectroscopy with Top-off Operations at the Advanced Light Source

Top-off operations is a quasi-continuous injection mode that increases the flux and brightness of a synchrotron source and improves thermal stability of optical components by maintaining a constant current in the storage ring. Although the increased and constant flux is advantageous for FTIR measurements, the frequent injections (about one every 30 seconds in the ALS case) introduce artifacts into the spectrum by creating spikes in the interferogram data. These spikes are caused by brief beam motion during the injection event. Here, we describe our efforts to minimize the effects of top-off generated interferogram spikes on several FTIR spectrometers. They include using a fast feedback mirror system to correct for beam motion and a gating signal to inhibit interferogram collection during a top-off injection.

43 PARTICLE ACCELERATORS↗

Portable TXRF Spectrometer with 10{sup -11}g Detection Limit and Portable XRF Spectromicroscope with Sub-mm Spatial Resolution

A portable total reflection X-ray fluorescence (TXRF) spectrometer that we have developed is applied to trace elemental analysis of water solutions. Although a 5 W X-ray tube is used in the portable TXRF spectrometer, detection limits of several ppb are achieved for 3d transition metal elements and trace elements in a leaching solution of soils, a leaching solution of solder, and alcoholic beverages are detected. Portable X-ray fluorescence (XRF) spectromicroscopes with a 1 W X-ray tube and an 8 W X-ray tube are also presented. Using the portable XRF spectromicroscope with the 1 W X-ray tube, 93 ppm of Cr is detected with an about 700 {mu}m spatial resolution. Spatially resolved elemental analysis of a mug painted with blue, red, green, and white is performed using the two portable spectromicroscopes, and the difference in elemental composition at each paint is detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication and Characterization of Elliptically-Curved, Laterally-Graded Multilayers for Focusing X-ray Polychromator Applications

We have developed a novel X-ray multilayer working as a focusing polychromator. A multilayer mirror enables independent designs of the focal length and the spectral dispersion, and much higher throughput than the curved crystal. Our ion beam sputtering deposition apparatus has a speed programmable shuttering system for control of the lateral thickness gradient. A SiC/C and three V/C multilayers were deposited on each 150 mm long Si wafers. Period thicknesses are tuned to the designed energy of 5-12 keV, 12-19 keV, 19-26 keV and 26-33 keV, respectively. Four multilayers were clamped to form a 600 mm long 5-33 keV range elliptic mirror on a shaped Cu base plate. The focal length is 700 mm, which is large enough for setups around the sample position. The energy calibration was performed at BL-15C of the Photon Factory based on absorption edges of metal foils, which was in good agreement with the period thickness measured by a laboratory X-ray diffractometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchronized monochromator and insertion device energy scans at SLS

Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

43 PARTICLE ACCELERATORS↗

Medipix3 array high performance read-out board for synchrotron research

The Medipix3 ASIC is one of the most advanced chip that is presently available to build photon counting area detectors. The capabilities of the chip include adjacent pixels charge summing circuitry to sort out the distortion due to charge sharing, simultaneous counting and read-out that enables frames to be acquired without dead time, the colour mode of operation that enables up to eight energy bands to be acquired. In order to fully exploit the capabilities of the Medipix3 chip in synchrotron research, a high performance electronic board capable of driving large arrays of chips is necessary. We propose a parallel read-out board of Medipix3 chip arrays with a scalable architecture that allows driving the Medipix3 chip in all of its modes of operation. The board functions include the control of the chip arrays, data formatting and data compression, the management of the communications with the data storage devices, and operation in various trigger modes. In addition to this the board will have some 'intelligence' embedded. This will add some very important features to the final detector such as pattern recognition, capability of variable frame duration as a function of the photon flux, feedback to other equipment and real time calculations of data relevant to experiments such as the autocorrelation function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ASTRO-H Mission

The joint JAXA/NASA Astro-H mission is the sixth in a series of X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). The planned launch date is 2014. Astro-H will investigate the physics of the high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate spatial resolution over the 0.3-600 keV energy range. ASTRO-H is a combination of wide band X-ray spectroscopy (3-80 keV) provided by focusing hard X-ray mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3-10 keV) provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD camera as a focal plane detector for a soft X-ray telescope and a non-focusing soft gamma-ray detector. The simultaneous broad bandpass, coupled with high spectral resolution of {Delta}E{approx}7 eV by the micro-calorimeter will enable a wide variety of important science themes to be pursued.

79 ASTRONOMY AND ASTROPHYSICS↗

Grating spectrometer system for beam emission spectroscopy diagnostics using high-energy negative-ion-based neutral beam injection on LHD

A beam emission spectroscopy (BES) system was developed for density gradient and fluctuation diagnostics in the Large Helical Device (LHD). In order to cover the large Doppler shift of the H{alpha} beam emission because of the high-energy negative-ion-based neutral beam atom (acceleration voltage V{sub acc}=90-170 kV) and the large motional Stark splitting due to the large vxB field (magnetic field B=3.0 T), a grating spectrometer was used instead of a conventional interference filter system. The reciprocal linear dispersion is about 2 nm/mm, which is sufficient to cover the motional Stark effect spectra using an optical fiber with a diameter of 1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Baryon spectroscopy: Recent results from the Crystal Barrel/TAPS experiment at ELSA

To understand the spectrum and the properties of baryon resonances, the CBELSA/TAPS experiment at ELSA investigates the photoproduction of single- and multi-meson final states off the nucleon. In the latter final states baryon cascades via Dp and Dh and also via higher mass baryon resonances are clearly observed. A partial wave analysis based on single and double meson photoproduction data as well as data from other reactions allows a first determination of resonance properties including partial decay widths of various N* and {Delta}* states. Those include also the decays into the different p{pi}{sup 0{pi}0} and p{pi}{sup 0{eta}} decay channels resulting partly in unexpected results. Recently not only single but also double polarisation experiments have been performed, which are absolutelly necessary to resolve ambiguities in the partial wave analyses (PWA) used to extract the resonances from the data; without the measurement of polarisation observables a model-independent PWA will not be possible. Polarisation observables have been investigated using linearly, circularly polarized or unpolarized photons impinging on an longitudinally polarized or unpolarized target. Given the angular coverage of the Crystal-Barrel/TAPS experiment this data cover almost the full angular range and phase space. This data will provide key information for the partial wave analyses and brings us one step closer towards the needed complete experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-medium modifications of the {omega} meson

We have investigated the in-medium modifications of {omega} mesons in photoproduction experiments using the Crystal Barrel(CB)/TAPS detector system at the ELSA accelerator facility in Bonn. {omega}-mesons were reconstructed using the {omega}{yields}{pi}{sup 0{gamma}} channel. In a first analysis of the data set on a Nb target, published by D. Trnka et al.. [1], evidence for an in-medium mass shift of the {omega}-meson was deduced from the observed {omega} lineshape. The signal shape is, however, sensitive to the background subtraction and fitting procedure as pointed out in the literature [2, 3]. For this reason a re-analysis of the same data set was initiated with the goal to reduce the background and to deduce the shape and the absolute magnitude of the background directly from the data. Here we present recent results from this re-analysis. The omega signal resulting after background subtraction has been compared to different scenarios of Gi-BUU transport model calculations for the full incident photon energy range (900-2200 MeV) and near the production threshold (900-1400 MeV).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗