Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Fracture resistance of vintage cast iron in gaseous hydrogen

In an effort to decarbonize legacy energy systems, several projects around the world are exploring alternatives to natural gas. Gaseous hydrogen is proposed as a carbon-free fuel to displace natural gas in existing legacy natural gas distribution systems, some of which continue to operate after 100 years (or more) in service. These systems, particularly in older industrial centers, contain cast iron pipe. However, the fracture resistance of most metals is degraded in gaseous hydrogen environments. This study evaluated the fracture resistance of several legacy cast iron pipe materials while exposed to gaseous hydrogen. Measurements were performed in three environments: air, a gas mixture with hydrogen partial pressure of 1 bar and pure hydrogen with a partial pressure of 34 bar. Although cast iron is generally considered a low ductility metal, elastic-plastic fracture methods are needed to assess the fracture resistance of the relatively small specimens that can be extracted from legacy pipe. Hydrogen reduced the fracture resistance of these cast iron materials by 10-40%. In air, the fracture resistance was determined to be as high as 21 MPa m 1/2 , whereas in gaseous hydrogen at pressure of about 1 bar the fracture resistance was as low as 13 MPa m 1/2 . Additional modest degradation of the fracture resistance was assessed at higher partial pressure (as low as 12 MPa m 1/2 ).

08 HYDROGEN↗

GridLAB-D Technical Support Document: Residential Equivalent Thermal Parameter Model

GridLAB-D is a power distribution systems simulation and analysis tool developed by Pacific Northwest National Laboratory. Although GridLAB-D and its underlying residential load model has been used in a variety of power systems analyses, comprehensive documentation of the derivation of the residential house model has not been formally published. The purpose of this technical support document is to serve as a comprehensive resource for the thermal dynamics modeling and house definition implemented in GridLAB-D. It covers model derivation, parameter definitions, and implementation steps in the codebase.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SBIR Phase I Final Report, TACO: Distributed and Heterogeneous Sparse Compiler

Tensor algebra is a powerful tool for computing, but writing optimized codes that operate on sparse tensors can be very complex. This project enables a Tensor Algebra Compiler (TACO) that simplifies this task from man-years to man-days and extends TACO to support complex and large distributed systems. This report details the hypotheses, approaches used, and findings in this project.

97 MATHEMATICS AND COMPUTING↗

T-FSM: A Scalable Distributed Task-Based System for Frequent Subgraph Pattern Mining from a Big Graph

Finding frequent subgraph patterns in a big graph is an important problem with many applications such as classifying chemical compounds and building indexes to speed up graph queries. Since this problem is NP-hard, some recent parallel and distributed systems have been developed to accelerate the mining. However, they often have a huge memory cost, very long running time, suboptimal load balancing, poor scale-out capability, and possibly inaccurate results. In this article, we propose an efficient system called T-FSM for parallel mining of frequent subgraph patterns in a big graph. T-FSM supports a new anti-monotonic frequentness measure called Fraction-Score, which is more accurate than the widely used MNI measure. The execution engine of T-FSM supports both intra-machine parallelism and inter-machine parallelism. For intra-machine parallelism, T-FSM adopts a novel task-based execution model to ensure high multithreading concurrency, bounded memory consumption, and effective load balancing. For inter-machine parallelism, T-FSM ensures good scale-out performance with a lightweight pattern rebalancing approach that reduces workload skewness of pattern evaluations among machines. To avoid recomputing the contexts for migrated patterns, we design a novel context cache table to support concurrent and asynchronous requesting and caching of remote context data, which can timely evict and garbage collect used pattern contexts that are no longer needed to keep memory consumption bounded. Extensive experiments show that T-FSM is orders of magnitude faster than existing state-of-the-art parallel systems (more than 10×, 51×, 131×, 55× speedup over ScaleMine, DistGraph, Pangolin and Peregrine, respectively) and distributed systems (more than 42× and 88× over ScaleMine and DistGraph, respectively) for frequent subgraph pattern mining, and it scales out satisfactorily to 512 CPU cores on the Polaris supercomputer at Argonne National Laboratory.

97 MATHEMATICS AND COMPUTING↗

Co-simulation of transactive energy markets: A framework for market testing and evaluation

The proliferation of distributed energy resources (DER)—and the ability to intelligently control these assets—is re-defining the electrical distribution system. As the number of controllable devices rapidly expands, grid operators must determine how to incorporate these assets while delivering reliable, equitable, and affordable electricity. One possible approach is to establish distribution-level electricity markets and allow devices/aggregations of devices to participate in price establishment. While this approach purports some of the same benefits as the highly successful wholesale electricity markets (i.e., open competition, efficient price discovery, reduced communication overhead), this needs to be researched and quantified via an analysis platform that models distribution-level markets at the appropriate fidelity. Specifically, the simultaneous evaluation of market performance, DER performance, DER bidding approaches, and distribution feeder power quality requires modeling that spans multiple technical areas. Co-simulation has emerged as a powerful tool in addressing this type of problem, where outputs depend on a range of underlying areas of expertise and associated models. In this paper we describe a solution, as implemented in the HELICS co-simulation platform, where we include (1) high fidelity house models, (2) intelligent bidding agents, (3) a modular market integration/design, and (4) a distribution feeder model. We then present a case study where we test two different market designs: (1) a pseudo-wholesale double-blind auction, and (2) an asynchronous matching market. In this work, the markets are run under two DER penetration levels and economic results are compared to full retail net energy metering and avoided cost net metering scenarios that bookend current approaches to remuneration of DER participation. We show the potential for transactive markets to provide increased value for most customers relative to net metering (and all customers relative to avoided cost scenarios) while decreasing costs for the utility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operating-Envelopes-Aware Decentralized Welfare Maximization for Energy Communities

We propose an operating-envelope-aware, prosumer-centric, and efficient energy community that aggregates individual and shared community distributed energy resources and transacts with a regulated distribution system operator (DSO) under a generalized net energy metering tariff design. To ensure safe network operation, the DSO imposes dynamic export and import limits, known as dynamic operating envelopes, on end-users' revenue meters. Given the operating envelopes, we propose an incentive-aligned community pricing mechanism under which the decentralized optimization of community members' benefit implies the optimization of overall community welfare. The proposed pricing mechanism satisfies the cost-causation principle and ensures the stability of the energy community in a coalition game setting. Numerical examples provide insights into the characteristics of the proposed pricing mechanism and quantitative measures of its performance.

distributed energy resources aggregation↗

Voltage regulation in distribution grids: A survey

Environmental and sustainability concerns have caused a recent surge in the penetration of distributed energy resources into the power grid. This may lead to voltage violations in the distribution systems making voltage regulation more relevant than ever. Owing to this and rapid advancements in sensing, communication, and computation technologies, the literature on voltage control techniques is growing at a rapid pace in distribution networks. In particular, there is a paradigm shift from traditional offline centralized approaches to distributed ones leveraging increased and varied types of actuators, real-time sensing, fast and efficient computations, and an overall distributed situational awareness. This paper reviews state-of-the-art voltage control algorithms, summarizes the underlying methods, and classifies their coordination mechanisms into local, centralized, distributed, and decentralized. The underlying solution methodologies are further classified into two categories, open-loop and feedback-based. Two specific example workflows are provided to illustrate these solutions for voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bridging Power System Protection Gaps with Data-driven Approaches

Protection is a critical function in power systems to avoid equipment damage, maintain personnel safety, and support system reliability. However, current protective relay technology cannot adequately protect equipment and personnel from effects of some events; these deficiencies are termed protection gaps. In this research, a data-driven approach is proposed to complement traditional protection technology and distinguish fault conditions from transients caused by normal operations. A convolutional neural network (CNN) based fault detection approach is implemented to achieve data translation invariance of the time-series input data. As a result, the data-driven method can accurately detect system faults despite variation and noise in the input data. In addition, using the CNN–based method avoids the complicated manual feature extraction procedure required by many traditional data-driven methods. The effectiveness of the proposed approach is tested on four kinds of protection gaps: high impedance faults, transformer/generator inter-turn faults, distribution system PV circuit faults, and the mis-operation situations of Zone 3 line protection relays operating under system stress. Finally, a transfer learning method is also proposed to address the common issue of data-driven methods for which real-world training data are scarce. Extensive study results demonstrate that the proposed approach can accurately bridge power system protection gaps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Results on Communication- and Memory-Aware Load Balancing Model and Algorithms

While load balancing in distributed-memory computing has been well-studied, we present an innovative approach to this problem: a unified, reduced-order model that combines three key components to describe “work” in a distributed system: computation, communication, and memory. Our model enables an optimizer to explore complex tradeoffs in task placement, such as augmented parallelism, at the expense of data replication increasing memory usage. We propose a fully distributed, heuristic-based load balancing optimization algorithm, and demonstrate that it quickly finds close-to-optimal solutions. We formalize the complex optimization problem as a mixed-integer linear program, and compare it to our strategy. Finally, we show that when applied to an electromagnetics code, our approach obtains up to 2.3x speedups for the imbalanced execution.

97 MATHEMATICS AND COMPUTING↗

A Relaxed PV Bus Model in Linear Power Flow

The emerging multimodal active energy resource units make it necessary to introduce constant voltage amplitude buses (PV bus) in the operation of modern distribution systems. To enable the analysis of PV bus using linear power flow models, this letter proposes a relaxed PV bus model for solving power flow related problems using an indirect modeling approach. The developed PV bus model can be applied to linear power flow models in both rectangular and polar coordinates. Besides, the approximation error of the relaxed PV bus model can also be controlled and quantified. Lastly, the proposed relaxed PV bus model is validated using different test systems. According to the numerical studies, the maximum error on the PV bus approximation in all case studies is only 0.61%, and the maximum error of the supporting power at the PV buses is 6.5%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part II: Large-Scale Demonstration

This work is the second of a two-part series in which we develop and experimentally demonstrate a hierarchical control solution for optimally coordinating thousands of deferrable loads and distributed energy resources (DERs) to provide fast frequency response (FFR) from an entire distribution feeder. In Part I, we developed and proved practical algorithms for fast, cost-based optimal dispatch and for determining the optimal amount of headroom to operate solar inverters with to support FFR dispatch while minimizing opportunity cost. Simulation results in Part I demonstrated the advantages of the hierarchical dispatch approach in being able to maintain fast solution times needed for FFR even when the problem size increases. In Part II, we implement the algorithms developed in Part I in a novel, large-scale power hardware-in-the-loop experiment including embedded controllers and more than 100 powered appliance loads and DER connected to a simulated real-world distribution system with more than 10,000 controlled devices. Experimental results from multiple scenarios confirm that the optimal FFR dispatch approach scales well and can optimally coordinate more than 10,000 net-load resources across a distribution network while achieving hardware response times within 500 ms, which is not possible using state-of-the-art optimal coordination approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Systems Integration Workshop

The U.S. Department of Energy’s Wind Energy Technologies Office (WETO) Wind Systems Integration Workshop was held to facilitate an exchange of information and to solicit feedback to inform WETO’s near- to mid-term research priorities and to accelerate near-term, rapid deployment and integration of wind technologies at both the transmission and distribution levels. Workshop participants identified key research challenges and opportunities for grid services, power electronics, modeling and decision-support tools, transmission and distribution system coordination, and applying energy equity principles to wind grid integration research.

17 WIND ENERGY↗

Comminty Geothermal: Planning and Design of a Heating and Cooling System in Framingham, Massachusetts

These reports, plans, and drawings review the achievements of Home Energy Efficiency Team (HEET) and its partners to plan and design a network of interconnected ground-source heat pump systems, or geothermal network, in an area encompassing multiple environmental justice (EJ) neighborhoods in the City of Framingham, MA. The materials provided in this dataset include, a) stakeholder and design best practices, b) study on optimal method to interconnect geothermal loops, c) guidelines for monitoring and metering, d) operations and maintenance plans, e) permitting guidelines and f) 10-day driller tutorial curriculum. These materials can guide the efficient and ethical design of future geothermal networks nationwide. The capacity of the system is estimated at 217 tons and is designed to provide 100% of heating and cooling needs for the buildings connected to the loop. In this project, 80 boreholes are used as the main thermal resources, the distribution system (or loop) consists of 0.61 miles of an 8-inch single-pipe at ambient temperature, with the capacity to connect 44 buildings, including 13 apartment buildings from the Framingham Housing Authority, one transitional home, one school building and 29 single family homes. While Framingham already has a geothermal network loop that is currently in the commissioning stage, our proposed project is unique because it is the first utility-led expansion loop (2nd loop) project that will connect to an adjacent existing geothermal loop (1st loop) in a pre-existing neighborhood. Both the 1st and 2nd loops are being installed, owned and operated by Eversource Energy, the utility Deployment Partner.

15 GEOTHERMAL ENERGY↗

Fragility Functions Resource Report: Documented Sources for Electricity and Water Resilience Valuation

Fragility curves provide the vulnerability between hazard intensity and an asset. Federal installations may include many different electricity and water infrastructure types (or assets) such as generators, wind turbines, solar PV, switch yards, substations and power lines as well as water distribution systems that could be affected by different hazards. The vulnerability of each asset is a function of its age, type of materials and maintenance. In addition, the vulnerability changes with the hazards intensity and has a probability distribution function associated with it. The fragility functions are used in conjunction with hazard probability and consequence valuations to determine the values at risk for examination of investment grade analyses of alternative mitigation strategies. This document provides examples of fragility functions and links to their sources for different electricity and water infrastructure assets by hazard type.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Intelligence Measurements and Sensor Systems (AIMS): Gaussian Processes in Remote Sensing: Literature Review

Power grid resilience and reliability is crucial to supporting critical infrastructure. Service interruptions can have devastating consequences to communication, emergency, and transportation services, just to name a few. In addition to infrastructure, power services are crucial to everyday life. Nearly every element of modern-day living relies on a stable and functioning power grid - heating and cooling systems to lighting, refrigeration, telecommunications, and internet access. Interruptions in the power supply can range from minor inconveniences, such as the temporary loss of internet or television services, to more significant problems, like the inability to access medical equipment or emergency services during critical situations. As climate conditions worsen, the reliability of the power grid becomes even more significant. Extreme weather events, such as hurricanes, wildfires, or severe storms, can cause serious damage to power infrastructure, leading to prolonged power outages. Rising temperatures and changing weather patterns can strain the grid, resulting in increased demand for electricity, stressing transmission and distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Non-Parametric Statistical Analysis of Current Waveforms through Power System Sensors

The protection, control, and monitoring of the power grid is not possible without accurate measurement devices. As the percentage of renewable energy sources penetrating the existing grid infrastructure increases, so do uncertainties surrounding their effects on the everyday operation of the power system. Many of these devices are sources of high-frequency transients. These transients may be useful for identifying certain events or behaviors otherwise not seen in traditional analysis techniques. Therefore, the ability of sensors to accurately capture these phenomena is paramount. In this work, two commercial-grade power system distribution sensors are investigated in terms of their ability to replicate high-frequency phenomena by studying their responses to three events: a current inrush, a microgrid “close-in”, and a fault on the terminals of a wind turbine. Kernel density estimation is used to derive the non-parametric probability density functions of these error distributions and their adequateness is quantified utilizing the commonly used root mean square error (RMSE) metric. It is demonstrated that both sensors exhibit characteristics in the high harmonic range that go against the assumption that measurement error is normally distributed.

47 OTHER INSTRUMENTATION↗

CHARACTERIZATION AND DEVELOPMENT OF THE ALL–AQUEOUS COPPER THERMALLY REGENERATIVE AMMONIA BATTERY

Low temperature thermal energy is an abundant and untapped energy source for large scale electrical power and energy production around the world. Many different stationary sources such as industrial and thermal power plants produce significant amounts of low temperature heat that goes unused. The primary reason for the energy loss is because the temperature of the heat is often too low for traditional systems to economically generate power from this waste heat. Many different technologies are being researched to produce grid–scale power from low temperature heat to increase grid efficiency, advance decarbonization efforts, and progress electrical power production to a more distributed system. A thermally regenerative battery (TRB) is one promising technology in this space, as it has large power and energy densities relative to competitive technologies and therefore has the potential to disrupt the current power generation mix. TRBs combine two unit operations (a redox flow battery and a distillation column) which are easily scalable and mature, meaning that if a viable TRB chemistry can be identified, its development to pilot and commercial scale can be streamlined. The all–aqueous, copper thermally regenerative ammonia battery (Cuaq–TRAB) was the first TRB that did not use an electrodeposition/dissolution reaction by stabilizing Cu(I) and Cu(II) in the electrolyte, allowing all electroactive species to be stable in an aqueous phase. Through these electrolyte modifications, coulombic efficiency, open circuit potential, and copper solubility all increased, resulting in large gains to power density, energy density, and energy efficiency.

Cross, Nicholas↗