Fermilab PIP-II CDS and CM Cryogenic Controls System

Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules. Design includes Siemens PCS7 Controls System with 26 Remote IO Rittal Cabinets and 48 Relay Racks for Temperature Readouts, Valve Positioners, Level, Heater Controls etc. Electrical Drawings and Design have been completed with focus now on fabrication of the 26 Rittal Cabinets and 48 Relay Racks. All materials have been procured. EPICS will be used as a SCADA system communicating to S7 Controllers via OPC UA.

Patel, Pratik [Fermilab]↗

Controlling the spatio-temporal dose distribution during STEM imaging by subsampled acquisition: In-situ observations of kinetic processes in liquids

Subsampled image acquisition followed by image inpainting in the scanning transmission electron microscope (STEM) is a novel approach to control dose and increase the image frame rate during experiments, thereby allowing independent control of the spatial and temporal dose envelope during image acquisition. Here, subsampled imaging is shown to permit precise in-situ observations of the fundamental kinetic processes behind nucleation and growth of silver (Ag) nanoparticles from an aqueous solution. At high sampling-levels, nanoparticles can be observed with morphologies that are consistent with strong interface interactions, i.e. rafts and pillars, whereas at low sampling-levels, the particles exhibit regular spherical morphologies. The relative numbers of rafts/pillars and regular nanoparticles, their sizes and their incubation times can be attributed to local changes in the molar concentration of the Ag ions in the aqueous solution; higher sampling-levels significantly increase the reactants in the vicinity of the window, leading to rapid supersaturation and the precipitation on the window surface. These precisely controlled kinetics highlight subsampled imaging as a method by which the driving force for nucleation and growth (i.e the electron beam) can be disentangled from the spatial/temporal resolution of the observation in all in-situ experiments, providing a pathway to identify and quantify the importance of individual kinetic factors behind nucleation and growth in a wide variety of complex materialssystems and architectures.

74 ATOMIC AND MOLECULAR PHYSICS↗

Analysis to Inform CA Grid Integration Rules for PV: Final Report on Inverter Settings for Transmission and Distribution System Performance

The fourth solicitation of the California Solar Initiative (CSI) Research, Development, Demonstration and Deployment (RD&D) Program established by the California Public Utilities Commission (CPUC) supported the Electric Power Research Institute (EPRI), National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) with data provided from Pacific Gas and Electric (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E) conducted research to determine optimal default settings for distributed energy resource advanced inverter controls. The inverter functions studied are aligned with those developed by the California Smart Inverter Working Group (SIWG) and those being considered by the IEEE 1547 Working Group. The advanced inverter controls examined to improve the distribution system response included power factor, volt-var, and volt-watt. The advanced inverter controls examined to improve the transmission system response included frequency and voltage ride-through as well as Dynamic Voltage Support. This CSI RD&D project accomplished the task of developing methods to derive distribution focused advanced inverter control settings, selecting a diverse set of feeders to evaluate the methods through detailed analysis, and evaluating the effectiveness of each method developed. Inverter settings focused on the transmission system performance were also evaluated and verified. Based on the findings of this work, the suggested advanced inverter settings and methods to determine settings can be used to improve the accommodation of distributed energy resources (PV specifically). The voltage impact from PV can be mitigated using power factor, volt-var, or volt-watt control, while the bulk system impact can be improved with frequency/voltage ride-through.

14 SOLAR ENERGY↗

Inverse Calculation of Burden Distribution Matrix Using B-spline Model Based PDF control in Blast Furnace Burden Charging Process

The inverse calculation of burden distribution matrix (BDM) is one of the most important challenges in the blast furnace operation in iron-making processes. In general, blast furnace consumes 65% of the total energy for the whole steel-making. Focusing on this practical challenge, this article proposes a new burden distribution spatial model in calculating burden charging process, and develops a B-spline approximation-based probability density function (PDF) control algorithm to assign the expected thickness distribution of burden layer and, thus, develops a new method for the required inverse calculation of BDM. First, a novel method for the thickness distribution of burden layer is given using B-spline model to produce an expected distribution shape subjected to a desired tracking within a specific spatial constraint. Then, according to the coexistence of continuous and bounded discrete variables in BDM, a novel hybrid optimization control method by combining integer programming and PDF tracking is further established for the effective inverse calculation of BDM. Finally, the proposed PDF-based iterative inverse calculation of BDM using B-spline models are tested using various data from industrial examples. Furthermore, the simulation results show that the proposed method is well suited to solve the BDM inverse calculation problem in practice.

42 ENGINEERING↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Ultrafast spatiotemporal laser pulse engineering using chromatic dispersion.

We discuss a new method for manipulating the optical field distribution in time and space at the focal plane of a chromatic lens. Chromatic dispersion and aberration make it possible to control the photon distribution in both time and space by properly controlling the amplitude and phase of the incident laser pulse, including shortening a laser pulse or generating a specific time-dependent transverse distribution. As an example, we discuss the generation of a quasi-three-dimensional ellipsoidal photon distribution and a proof-of-principle experiment, where favourable agreement between theoretical calculations and the data is observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing Electric Grid System Benefits of MPC-Based Residential Load Shaping: Preprint

Routinely encouraging and discouraging residential electric load throughout the day will be increasingly critical in efficiently managing the smart grid to reliably deliver clean, low-cost electricity. Yet, manipulating the duty cycles of thermostatically controlled loads such as heating, air conditioning, and hot water heaters can have the effect of destabilizing or stabilizing the grid. This work explores the potential for price-responsive control of residential air conditioning to shape electric demand at the distribution feeder level to minimize electricity production costs. Physical models of the interplay between building thermal and electric loads are used to Simulate time-series temperature and load behavior. Instantaneous load-adding and load-shedding opportunities are quantified in more than 100,000 individual homes on 204 distribution feeders with results presented for 35 cities across the United States. In the context of distributed model predictive control, simulation of feeder-level response to a residential day-ahead 5-minute pricing vector to 2,146 homes highlights an aggregate impact of flexible loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Decentralized State Estimation and Remedial Control Action for Minimum Wind Curtailment Using Distributed Computing Platform

Intermittency of wind energy poses a great challenge for power system operation and control. Wind curtailment might be necessary at the certain operating condition to keep the line flow within the limit. Remedial Action Scheme (RAS) offers quick control action mechanism to keep reliability and security of the power system operation with high wind energy integration. In this paper, a new RAS is developed to maximize the wind energy integration without compromising the security and reliability of the power system based on specific utility requirements. A new Distributed Linear State Estimation (DLSE) is also developed to provide the fast and accurate input data for the proposed RAS. A distributed computational architecture is designed to guarantee the robustness of the cyber system to support RAS and DLSE implementation. The proposed RAS and DLSE is validated using the modified IEEE-118 Bus system. Simulation results demonstrate the satisfactory performance of the DLSE and the effectiveness of RAS. Real-time cyber-physical testbed has been utilized to validate the cyber-resiliency of the developed RAS against computational node failure.

17 WIND ENERGY↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From Femtoseconds to Gigaseconds: The SolDeg Platform for the Performance Degradation Analysis of Silicon Heterojunction Solar Cells

Heterojunction Si solar cells exhibit notable performance degradation. Here, we modeled this degradation by electronic defects getting generated by thermal activation across energy barriers over time. To analyze the physics of this degradation, we developed the SolDeg platform to simulate the dynamics of electronic defect generation. First, femtosecond molecular dynamics simulations were performed to create a-Si/c-Si stacks, using the machine learning-based Gaussian approximation potential. Second, we created shocked clusters by a cluster blaster method. Third, the shocked clusters were analyzed to identify which of them supported electronic defects. Fourth, the distribution of energy barriers that control the generation of these electronic defects was determined. Fifth, an accelerated Monte Carlo method was developed to simulate the thermally activated time-dependent defect generation across the barriers. Our main conclusions are as follows. (1) The degradation of a-Si/c-Si heterojunction solar cells via defect generation is controlled by a broad distribution of energy barriers. (2) We developed the SolDeg platform to track the microscopic dynamics of defect generation across this wide barrier distribution and determined the time-dependent defect density N(t) from femtoseconds to gigaseconds, over 24 orders of magnitude in time. (3) We have shown that a stretched exponential analytical form can successfully describe the defect generation N(t) over at least 10 orders of magnitude in time. (4) We found that in relative terms, Voc degrades at a rate of 0.2%/year over the first year, slowing with advancing time. (5) We developed the time correspondence curve to calibrate and validate the accelerated testing of solar cells. We found a compellingly simple scaling relationship between accelerated and normal times t normal ∝ t accel T(accel)/T(normal) . (6) We also carried out experimental studies of defect generation in a-Si:H/c-Si stacks. We found a relatively high degradation rate at early times that slowed considerably at longer time scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sequential Mitigation Solutions to Enable Distributed PV Grid Integration: Preprint

This paper provides a method to assess the impact of multiple mitigation solutions including distribution grid upgrades and advanced control technologies on increasing distributed PV penetration in distribution feeders, and thus paves the way to estimate the costs needed for reaching certain PV penetration level. Based on three assumptions of creating increasing PV penetration scenarios, this paper first studies the distribution impact of PV power and quantifies the PV hosting capacity in distribution feeders. Then, it studies multiple mitigation solutions to increase PV penetration on distribution feeders. These mitigation solutions are implemented in a sequential manner according to their typical costs. The proposed study is demonstrated on two representative distribution feeders.

14 SOLAR ENERGY↗

A simulation-based study on different control strategies for variable speed pump in distributed ground source heat pump systems

Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional control strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Voltage Regulation Performance Evaluation of Distributed Energy Resource Management via Advanced Hardware-in-the-Loop Simulation

This paper evaluates the performance of coordinated control across advanced distribution management systems (ADMS), distributed energy resources (DERs), and distributed energy resource management systems (DERMS) using an advanced hardware-in-the-loop (HIL) platform. This platform provides a realistic laboratory testing environment, including accurate dynamic modeling of a real-world distribution system from a utility partner, real controllers (ADMS and DERMS), physical power hardware (DERs), and standard communications protocols. One grid service—voltage regulation—is evaluated to show the performance of the coordinated grid automation system. The testing results demonstrate that the coordinated DERMS and ADMS system can effectively regulate system voltages within target operation limits using DERs. The realistic laboratory HIL testing results give utilities confidence in adopting the grid automation systems to manage DERs to achieve system-level control and operation objectives (e.g., voltage regulation). This helps utilities mitigate potential risks (e.g., instability) prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust and resilient coordination of feeders with uncertain distributed energy resources: from real-time control to long-term planning

To enable flexible demand and ensure reliable and economical operation of distribution systems, we present a novel hierarchical scheme that actively coordinates responsive behind-the-meter grid resources, including distributed energy resources (DERs), to reliably manage each unbalanced distribution feeder and exploits the available flexibility to economically optimize the entire network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

14 SOLAR ENERGY↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (controllable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Distributed Conditions for Small-signal Stability of Power Grids and Local Control Design

Operating modern power grids with stability guarantees is markedly important. Typical methods for analyzing and certifying power grid stability are largely centralized relying on the ability of the system operator to gather network-wide information and accurately compute the system's eigenvalues. These methods are oftentimes not privacy-preserving and computationally burdensome. They are therefore, not well-suited to modern power grids where small-signal stability has to be evaluated timely, efficiently and in a privacy-preserving fashion. Herein, we introduce a distributed methodology for certifying small-signal stability of power grids and designing the local controllers. First, we analytically derive distributed conditions for network-wide stability that bus agents can inspect using local information. By leveraging these conditions, we then introduce a distributed control design algorithm (DCDA) that can guide the local control design so that stability of the interconnected system is guaranteed. The agents that adopt the proposed distributed algorithm are responsible for tuning their local controllers, producing their local control commands and ensuring that their local stability condition is met. The system operator is only responsible for verifying network-wide stability upon receiving affirmative responses from all agents and, announcing, that the overall system is stable. The proposed DCDA algorithm is numerically validated via simulations using the IEEE 39-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.