Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Towards Misregistration-Tolerant Change Detection using Deep Learning Techniques with Object-Based Image Analysis

Co-registrating is a common pre-processing step for existing change detection algorithms, but registering bi-temporal images is nontrivial. The use of image patch as input for deep learning techniques provides a natural avenue to apply them in the OBIA framework, and have shown successful performance in the object-based land cover mapping and change detection applications. Even though attempts of applying deep learning techniques for change detection applications have been made with varying success, its application under OBIA framework for change detection have not been conducted and its tolerance for misregistration among temporal images are neither known. This study performed change detection under OBIA framework using deep learning techniques for the first time, and evaluated its performance regarding their tolerance of image misregistration on training and testing dataset. Our results demonstrate the proposed change detection scheme is surprisingly robust to image misregistration on the testing dataset, while classifiers trained with the training dataset containing image misregistration errors suffer from slight decrease of overall accuracy.

Liu, Tao↗

Toward the Detection of Polyglot Files

Standardized file types play a key role in the development and use of computer software. However, it is possible to confound standardized file type processing by creating a file that is valid in multiple file types. The resulting polyglot (many languages) file can confuse file type identification, allowing elements of the file to evade analysis. This is especially problematic for malware detection systems that rely on file type identification for feature extraction. Although work has been done to identify file types using more comprehensive methods than file signatures, accurate identification of polyglot files remains an open problem. Since malware detection systems routinely perform file type-specific feature extraction, polyglot files need to be filtered out prior to ingestion by these systems. Otherwise, malicious content could pass through undetected. To address the problem of polyglot detection we assembled a data set using the mitra tool. We then evaluated the performance of the most commonly used file identification tools, including file, polydet, binwalk, and TrID. Our analysis demonstrates that existing file type detection tools fail to provide reliable polyglot detection. We then evaluated the ability of a range of machine and deep learning models to detect polyglot files. The most performant models were MalConv2 and Catboost, which demonstrated the highest recall on our data set with 95.16% and 95.45%, respectively. These models outperformed existing methods and could be incorporated into a malware detector’s file processing pipeline to filter out potentially malicious polyglots before file type-dependent feature extraction takes place.

Koch, Luke↗

Toward the Detection of Polyglot Files

Standardized file types play a key role in the development and use of computer software. However, it is possible to confound standardized file type processing by creating a file that is valid in multiple file types. The resulting polyglot (many languages) file can confuse file type identification, allowing elements of the file to evade analysis. This is especially problematic for malware detection systems that rely on file type identification for feature extraction. Although work has been done to identify file types using more comprehensive methods than file signatures, accurate identification of polyglot files remains an open problem. Since malware detection systems routinely perform file type-specific feature extraction, polyglot files need to be filtered out prior to ingestion by these systems. Otherwise, malicious content could pass through undetected. To address the problem of polyglot detection we assembled a data set using the mitra tool. We then evaluated the performance of the most commonly used file identification tools, including file, polydet, binwalk, and TrID. Our analysis demonstrates that existing file type detection tools fail to provide reliable polyglot detection. We then evaluated the ability of a range of machine and deep learning models to detect polyglot files. The most performant models were MalConv2 and Catboost, which demonstrated the highest recall on our data set with 95.16% and 95.45%, respectively. These models outperformed existing methods and could be incorporated into a malware detector’s file processing pipeline to filter out potentially malicious polyglots before file type-dependent feature extraction takes place.

Koch, Lucas↗

EQ_phase_detection

The EQ_phase_detection software is designed to scan continuous daily waveforms to detect earthquake phase arrivals from local to regional (150 km) events. The detections are made with a deep learning encoder-decoder model. When the model detects an earthquake in the waveforms, a second model is implemented to classify the first arriving motions. Both deep learning models are trained with the Tensorflow package using publicly available benchmark data sets. The software input is a path to a directory that contains waveforms in mseed format and the associated response files in xml format. The output is a data table of time stamped detections, signal amplitude, signal-to-noise ratio, and softmax probability of the detection in a generic format applicable to post-processing association algorithms for event locations. Additionally, the p-wave and s-wave waveforms are saved in a data table for rapid access when producing improved locations using correlation-based techniques. The software is designed for multiprocessing with multiple GPU’s for rapid processing of large data sets. The configuration file provides flexibility in the trained models implemented and allows access to multiple models trained for different sampling rates or input dimensions. This is particularly useful for regions with multiple networks that do not have the same data parameters.

Johnson, Christopher↗

Narrow-Band Imaging Improves Detection of Colorectal Peritoneal Metastases: A Clinical Study Comparing Advanced Imaging Techniques

Background: Colorectal peritoneal metastases (PM) are often diagnosed in an advanced disease stage. Cytoreduction and hyperthermic intraperitoneal chemotherapy (HIPEC) improve survival of patients with colorectal PM, although most benefit is seen in patients with limited peritoneal disease. Advanced imaging techniques might improve the detection of PM, potentially leading to earlier diagnosis and improved cytoreduction. This prospective clinical trial compared three advanced techniques with conventional white-light imaging for the detection of colorectal PM: narrow-band imaging (NBI), near-infrared indocyanine green fluorescent imaging (NIR-ICG), and spray-dye chromoendoscopy (SDCE). Methods: Patients with colorectal PM were prospectively included. Prior to cytoreduction and HIPEC, all abdominal regions were inspected with white-light imaging, NBI, NIR-ICG, and SDCE during exploratory laparoscopy. Primary endpoints were sensitivity and specificity for the detection of PM, using pathological examination of biopsied lesions as the reference standard. The safety of all techniques was assessed. Results: Between May 2016 and March 2018, four different techniques were analyzed in 28 patients, resulting in 169 biopsies. Sensitivity for the detection of PM significantly increased from 80.0% with white light to 96.0% with NBI (p = 0.008), without loss of specificity (74.8% vs. 73.1%, respectively, p = 0.804). The use of NIR-ICG and SDCE was discontinued after 10 patients had undergone treatment because the lesions were not fluorescent using NIR-ICG, and because SDCE did not visualize the whole peritoneum. No adverse events relating to the imaging techniques occurred. Conclusion: NBI substantially increased the detection of PM. This method is safe and could improve the detection of metastatic lesions and help optimize cytoreduction in patients with colorectal PM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrabroadband 2D electronic spectroscopy with high-speed, shot-to-shot detection

Two-dimensional electronic spectroscopy (2DES) is an incisive tool for disentangling excited state energies and dynamics in the condensed phase by directly mapping out the correlation between excitation and emission frequencies as a function of time. Despite its enhanced frequency resolution, the spectral window of detection is limited to the laser bandwidth, which has often hindered the visualization of full electronic energy relaxation pathways spread over the entire visible region. Here, we describe a high-sensitivity, ultrabroadband 2DES apparatus. We report a new combination of a simple and robust setup for increased spectral bandwidth and shot-to-shot detection. We utilize 8-fs supercontinuum pulses generated by gas filamentation spanning the entire visible region (450 – 800 nm), which allows for a simultaneous interrogation of electronic transitions over a 200-nm bandwidth, and an all-reflective interferometric delay system with angled nanopositioner stages achieves interferometric precision in coherence time control without introducing wavelength-dependent dispersion to the ultrabroadband spectrum. To address deterioration of detection sensitivity due to the inherent instability of ultrabroadband sources, we introduce a 5-kHz shot-to-shot, dual chopping acquisition scheme by combining a high-speed line-scan camera and two optical choppers to remove scatter contributions from the signal. Comparison of 2D spectra acquired by shot-to-shot detection and averaged detection shows a 15-fold improvement in the signal-to-noise ratio. In conclusion, this is the first direct quantification of detection sensitivity on a filamentation-based ultrabroadband 2DES apparatus.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface-Enhanced Raman Spectroscopy Detection of Ionic Solutes by Surfactant-Mediated Adsorption to a Hydrophobic Surface

Chemical modification of the surfaces of surface-enhanced Raman spectroscopy (SERS)-active metals with thin molecular layers expands the variety of molecular species that can be attracted to the SERS surface from solution. This approach can provide selective detection of new classes of molecules that would not otherwise be detectable through direct interaction with a SERS-active metal. For example, polycyclic aromatic compounds can be attracted from aqueous solution to gold or silver SERS substrates that are modified with alkylsilanes or alkanethiols. While n-alkane monolayers attract hydrophobic solutes to a SERS-active surface, they are not well suited to adsorbing more water-soluble, ionized species from solution. In this work, we address SERS detection of ionic solutes by applying the principles of ion-interaction chromatography, where a charged surfactant is added to solution and adsorbs to an n-alkane-modified, SERS-active surface. The adsorbed charged surfactant serves to attract an ionic solute of opposite charge to the surface, where it can be detected. This concept was tested with a model anionic solute, 3-nitrobenzenesulfonate (NBS – ), with a cationic surfactant, cetylpyridinium (CP + ), that adsorbs to a 1-dodecanethiol (C 12 )-modified silver surface. The interfacial populations of both the surfactant and anionic solute can be determined simultaneously from SERS spectra. The adsorption equilibrium of CP + to the C 12 surface was fit to a Langmuir model, and the effect of supporting electrolyte on its adsorption equilibria was also investigated by SERS. The retention of NBS – at the C 12 surface depends on the concentration of CP + . The binding of NBS – to adsorbed CP + is described by an ion-interaction model that includes competition for the NBS – population due to association with surfactant ions in solution. Furthermore, while the strength of this binding interaction is not as great as the hydrophobic interactions that drive aromatic hydrocarbons to hydrophobic SERS surfaces, SERS detection of analyte ions by this approach could be accomplished at concentrations two orders of magnitude lower compared with Raman detection in free solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Bacillus anthracis DNA in Complex Soil and Air Samples Using Next-Generation Sequencing

Bacillus anthracis is the potentially lethal etiologic agent of anthrax disease, and is a significant concern in the realm of biodefense. One of the cornerstones of an effective biodefense strategy is the ability to detect infectious agents with a high degree of sensitivity and specificity in the context of a complex sample background. The nature of the B. anthracis genome, however, renders specific detection difficult, due to close homology with B. cereus and B. thuringiensis. We therefore elected to determine the efficacy of next-generation sequencing analysis and microarrays for detection of B. anthracis in an environmental background. We applied next-generation sequencing to titrated genome copy numbers of B. anthracis in the presence of background nucleic acid extracted from aerosol and soil samples. We found next-generation sequencing to be capable of detecting as few as 10 genomic equivalents of B. anthracis DNA per nanogram of background nucleic acid. Detection was accomplished by mapping reads to either a defined subset of reference genomes or to the full GenBank database. Moreover, sequence data obtained from B. anthracis could be reliably distinguished from sequence data mapping to either B. cereus or B. thuringiensis. We also demonstrated the efficacy of a microbial census microarray in detecting B. anthracis in the same samples, representing a cost-effective and high-throughput approach, complementary to next-generation sequencing. Our results, in combination with the capacity of sequencing for providing insights into the genomic characteristics of complex and novel organisms, suggest that these platforms should be considered important components of a biosurveillance strategy.

59 BASIC BIOLOGICAL SCIENCES↗

Three-Component Spectroelectrochemical Sensor Module for the Detection of Pertechnetate (TcO4-)

This review looks at the advancements in the development of a sensor for technetium (Tc) that is applicable to characterizing and monitoring the vadose zone and associated subsurface water. Subsurface contamination by Tc is of particular concern for two reasons: the extremely long lifetime of its most common isotope 99Tc (half-life = 2 x 105 years) and the fast migration in soils of pertechnetate (TcO4–) which is considered to be the dominant 99Tc species in ground water. TcO4– does not have a characteristic spectral signature which prevents its rapid, sensitive, and economic in-situ detection. To address this problem, a novel spectroelectrochemical sensor has been designed that combines three modes of selectivity (electrochemistry, spectroscopy, and selective partitioning) into a single sensor to substantially improve specificity which is critical in the specific detection of an analyte in the presence of potential interfering species. The sensor consists of a basic spectroelectrochemical configuration: a waveguide with an optically transparent electrode (OTE) that is coated with a thin chemically-selective film that preconcnetrates the analyte. The key to adapting this generic sensor to detect TcO4– and Tc complexes lies in the development of chemically-selective films that preconcentrate the analyte and, when necessary, chemically convert it into a complex with electrochemical and spectroscopic properties appropriate for sensing. This review focuses on the general concept of the sensor and the rationale for the selection of the specific components of choice, the development and characterization of the sensor for the different detection modules, the synthesis and characterization of complexes relevant in the detection of technetium, and the progress in the utilization of the sensor module for the effective detection of these complexes.

Environmental Molecular Sciences Laboratory↗

QUENCH DETECTION IN A SUPERCONDUCTING RADIO FREQUENCY CAVITY WITH COMBINED TEMPERATURE AND MAGNETIC FIELD MAPPING

Local dissipation of RF power in superconducting radio frequency cavities create so called "hot-spots", primary precursors of cavity quench driven by either thermal or magnetic instability. These hot-spots are detected by a temperature mapping system, and a large increase in temperature on the outer surface is detected during cavity quench events. Here, we have used combined magnetic and temperature mapping systems using anisotropic magneto-resistance (AMR) sensors and carbon resisters to locate the hot spots and areas with high trapped flux on a 3.0 GHz single-cell Nb cavity during the RF tests at 2.0 K. The quench location and hot spots were detected near the equator when the residual magnetic field in the Dewar is kept < 1 mG. The hot spots and quench locations moved when the magnetic field is trapped locally, as detected by T-mapping system. No significant dynamics of trapped flux is detected by AMR sensors, however change in magnetic flux during cavity quench is detected by a flux gate magnetometer, close to the quench location. The result provide the direct evidence of hot spots and quench events due to localized trapped vortices.

Ciovati, Gianluigi↗

Detection of Lipomannan in Cattle Infected with Bovine Tuberculosis

Early and rapid detection of bovine tuberculosis (bTB) is critical to controlling the spread of this disease in cattle and other animals. Here in this study, we demonstrate the development of an immunoassay for the direct detection of the bovine bTB biomarker, lipomannan (LM) in serum using a waveguide-based optical biosensor. We apply an ultra-sensitive detection strategy developed by our team, termed lipoprotein capture, that exploits the pull-down of high-density lipoprotein (HDL) nanodiscs from cattle blood that allows for the recovery and detection of associated LM. We also profile the change in the expression of these TB biomarkers as a function of time from a small set of samples collected from studies of bovine TB-infected cattle. Lastly, we demonstrate for the first time the direct detection of bovine LM in serum, and clearly show that the biomarker is expressed in detectable concentrations during the entire course of the infection.

59 BASIC BIOLOGICAL SCIENCES↗

UAS Detection Classification and Neutralization: Market Survey 2015

The purpose of this document is to briefly frame the challenges of detecting low, slow, and small (LSS) unmanned aerial systems (UAS). The conclusion drawn from internal discussions and external reports is the following; detection of LSS UAS is a challenging problem that cannot be achieved with a single detection modality for all potential targets. Classification of LSS UAS, especially classification in the presence of background clutter (e.g., urban environment) or other non-threating targets (e.g., birds), is under-explored. Though information of available technologies is sparse, many of the existing options for UAS detection appear to be in their infancy (when compared to more established ground-based air defense systems for larger and/or faster threats). Companies currently providing or developing technologies to combat the UAS safety and security problem are certainly worth investigating, however, no company has provided the statistical evidence necessary to support robust detection, identification, and/or neutralization of LSS UAS targets. The results of a market survey are included that highlights potential commercial entities that could contribute some technology that assists in the detection, classification, and neutralization of a LSS UAS. This survey found no clear and obvious commercial solution, though recommendations are given for further investigation of several potential systems.

42 ENGINEERING↗

Application of Frequency of Detection Methods in Design and Optimization of the INL Site Ambient Air Monitoring Network

This report presents an evaluation of a hypothetical INL Site monitoring network and the existing INL air monitoring network using frequency of detection methods. The hypothetical network was designed to address the requirement in 40 CFR Part 61, Subpart H (2006) that “emissions of radionuclides to ambient air from U.S. DOE facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent exceeding 10 mrem/year.” To meet the requirement for monitoring only, “radionuclide releases that would result in an effective dose of 10% of the standard shall be readily detectable and distinguishable from background.” Thus, the hypothetical network consists of air samplers placed at residence locations that surround INL and at other locations where onsite livestock grazing takes place. Two exposure scenarios were used in this evaluation: a resident scenario and a shepherd/rancher scenario. The resident was assumed to be continuously present at their residence while the shepherd/rancher was assumed to be present 24-hours at a fixed location on the grazing allotment. Important radionuclides were identified from annual INL radionuclide National Emission Standards for Hazardous Pollutants reports. Important radionuclides were defined as those that potentially contribute 1% or greater to the annual total dose at the radionuclide National Emission Standards for Hazardous Pollutants maximally exposed individual location and include H-3, Am-241, Pu-238, Pu 239, Cs-137, Sr-90, and I-131. For this evaluation, the network performance objective was set at achieving a frequency of detection greater than or equal to 95%. Results indicated that the hypothetical network for the resident scenario met all performance objectives for H-3 and I-131 and most performance objectives for Cs-137 and Sr-90. However, all actinides failed to meet the performance objectives for most sources. The shepherd/rancher scenario showed that air samplers placed around the facilities every 22.5 degrees were very effective in detecting releases, but this arrangement is not practical or cost effective. However, it was shown that a few air samplers placed in the prevailing wind direction around each facility could achieve the performance objective of a frequency of detection greater than or equal to 95% for the shepherd/rancher scenario. The results also indicate some of the current sampler locations have little or no impact on the network frequency of detection and could be removed from the network with no appreciable deterioration of performance. Results show that with some slight modifications to the existing network (i.e., additional samplers added north and south of the Materials and Fuels Complex and ineffective samplers removed), the network would achieve performance objectives for all sources for both the resident and shepherd/rancher scenario.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Detection and Characterization of Emerging Foreign Animal Disease Pathogens

To best safeguard human and animal health requires early detection and characterization of disease events. This must include effective surveillance for emerging infectious diseases. Both deliberate and natural outbreaks have enormous economic and public health impacts, and can present serious threats to national security. In this project, we developed novel next generation detection technologies to protect the agricultural economy and biosecurity. The first technology is a multiplexed assay to simultaneously detection 10 swine viral and bacterial pathogens. The second one is the Lawrence Livermore Microbial Detection Array (LLMDA) which can detect more than 10,000 microbial species including 4219 viruses, 5367 bacteria, 265 fungi, 117 protozoa and 293 archaea. We analyzed a series of swine clinical samples from past disease events to demonstrate the utility of the assays for faster and cheaper detection of emerging and foreign animal disease pathogens, and their utility as s routine diagnosis and surveillance tool. A second goal of the study is to better understand mechanisms of African swine fever virus (ASFV) infection in pigs to aid the development of countermeasures and diagnostics. There is no vaccine available for ASF. ASF outbreak is on the rise on several European countries. Though ASF is not currently in the U.S., a potential outbreak in the U.S. would be detrimental to the swine industry and the US agricultural economy. We pursued a genome-wide approach to characterize the pig immune responses after ASFV infection. We used RNA sequencing and bioinformatics methods to identify genes and pathways that are affected during ASF infection. We have identified a list of most differentially expressed genes that are in the immune response pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Demonstration and Validation of a Portable Raman Sensor for In-Situ Detection and Monitoring of Perchlorate (ClO 4 - )

Costs for environmental analysis and monitoring are increasing at a rapid rate and represent a significant percentage of the total and future remedial expenses at many U.S. Department of Defense (DoD) contaminated sites. It has been reported that about 30 to 40% of the remediation budget is usually spent on long-term monitoring (LTM), of which a large percentage represents laboratory analytical costs. Energetics such as perchlorate (ClO 4 - ) are among the most frequently detected contaminants in groundwater and surface water at or near military installations due to their persistence and mobility. Currently, the standard protocol entails collecting samples in the field, packaging them, and shipping them overnight to a designated laboratory for analysis. This process requires significant sample preparation and handling, and analytical results may not be available for several days to weeks. In this project, we developed and demonstrated a portable Raman sensor based on surface enhanced Raman scattering (SERS) technology to detect ClO 4 - in contaminated water. We summarize major accomplishments as follows: • A SERS sensor based on elevated gold (Au) nano-ellipse dimer architectures was designed and developed for ClO 4 - with a detection limit of ~10 -6 M (or 100 μg/L); The performance of these sensors was evaluated and optimized through variation of their geometric characteristics (i.e., dimer aspect ratio, dimer separation, etc.). • Large-scale commercial production of SERS substrate sensors via nanoimprinting by Nanova Inc. and Nanoimprint lithography (NIL) technology was successfully demonstrated. This is a substantial step forward toward the commercialization of the SERS sensors and may potentially lead to significantly reduced fabrication costs of SERS substrates. • Commercially produced SERS sensors were demonstrated to detect ClO 4 - at levels above 10 -6 M using a portable Raman analyzer. The performance of the commercial SERS sensors for ClO 4 - detection in the presence and absence of interferences was determined for a series of standard solutions. Sulfate (SO 4 2- ) was found to exhibit the greatest interference for the anions tested, which included Cl-, NO 3 - , and SO 4 2- . • Field demonstration of the portable Raman sensor with commercially produced SERS substrates was completed at two Department of Defense (DoD) sites; twice at the Indian Head Naval Surface Warfare Center, Indian Head, MD, and once at Redstone Arsenal, Huntsville, AL. Multiple wells were sampled at both DoD sites, where a standard addition method was employed using the sensor to determine the ClO 4 - 4 - and possibly other energetics that are both important for environmental monitoring and of interest for national security. However, we point out that SERS technology is also prone to interferences due to its sensitivity and responses to other ionic species, such as NO 3 - , SO 4 2- , and dissolved organics or co-contaminants present in the groundwater, which could potentially mask the SERS signal of the target analyte (i.e., ClO 4 - ). As such, SERS analysis was subject to significant variations (e.g., ±20% or more), and its detection limit for ClO 4 - -8 M) and was substantially higher than what we anticipated from laboratory studies. However, despite these complications, the portable Raman sensor developed in this project could be used as a rapid screening tool for ClO 4 - at concentrations above 10 -6 M. Future studies are warranted to further develop the technology and to optimize its performance, and eventually to bring the technology to the market. With additional development and demonstration, the sensor has the potential to reduce analytical costs by eliminating shipping and typical costs associated with laboratory analysis. A cost savings of 30–45% may be realized during a typical sampling event and, more importantly, the technology could allow rapid turn-around of information to decision makers for site characterization and remediation.

47 OTHER INSTRUMENTATION↗

Development of Gamma Background Radiation Digital Twin with Machine Learning Algorithms: Application of Unsupervised Machine Learning to Detection of Anomalies and Nuisances in Gamma Background Radiation Environmental Screening Data

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for development of a digital twin of gamma radiation background, and for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. In one segment of work, we developed a gamma background estimation model using a Longshort term memory (LSTM) network for one-step CPS time series prediction. The LSTM model was validated with two data sets of measurements from two independent NaI detectors positioned on a mobile platform. The data sets contained background radiation only and no orphan isotope sources. The LSTM model was constructed and tested using data from one of the detectors. Performance of the LSTM model was validate through one-step prediction of CPS time series of another NaI detector without re-training. This approach allows to create a digital twin for nuclear background estimation. Using LSTM, it could be possible to detect a source through subtraction of the estimated counts from the measured background. In another segment of work, we investigated detection of gamma emitting sources in the presence of complex background using unsupervised machine learning. Spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

54 ENVIRONMENTAL SCIENCES↗

Magnetic Induction Sensors for Detecting Anomalous Shielding of Radiological and Nuclear Materials: A Feasibility Study

This study examined a concept for improving the nation's ability to detect unauthorized transport of radiological and nuclear material that involves detecting not the radiological or nuclear material itself, but rather the anomalous presence of materials, such as lead and tungsten, typically used to shield such illicit materials from detection. Specifically, the project studied a potentially inexpensive, non-intrusive, and fast method of detecting anomalous shielding: use of magnetic induction sensors to measure currents induced in conductors by a driver coil. The first phase of this work, documented in this report, identified the signatures of materials of interest, assessed the usefulness of measured signatures for discrimination between materials, and then benchmarked models and calculations. The next task involved assessing the strength of these signatures when the materials of interest were enclosed within other materials, such as aluminum and steel, of various thicknesses. A final task mimicked a real-world scenario by testing the ability to detect material signatures of interest at a scale of a vehicle or cargo vessel against a cluttered backdrop, with and without the shielding of another material, such as aluminum or steel. This final task raised doubts regarding whether this detection scheme will be useful under real-world conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lightning Flash Detection System (LFDS) [Poster]

The Electromagnetics Group wanted another system for detecting lightning flashes near/around the Pantex Plant. The current system in use detects lightning by detecting RF signals at a particular frequency. LFDS detects lightning by detecting flashes of light in the visual and near IR spectrums. This work is primarily focused on detecting cloud-to-ground lightning.

42 ENGINEERING↗