Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Experimental comparison of grating- and propagation-based hard X-ray phase tomography of soft tissue

When imaging soft tissues with hard X-rays, phase contrast is often preferred over conventional attenuation contrast due its superior sensitivity. However, it is unclear which of the numerous phase tomography methods yields the optimized results at given experimental conditions. Therefore, we quantitatively compared the three phase tomography methods implemented at the beamline ID19 of the European Synchrotron Radiation Facility: X-ray grating interferometry (XGI), and propagation-based phase tomography, i.e., single-distance phase retrieval (SDPR) and holotomography (HT), using cancerous tissue from a mouse model and an entire heart of a rat. We show that for both specimens, the spatial resolution derived from the characteristic morphological features is about a factor of two better for HT and SDPR compared to XGI, whereas the XGI data generally exhibit much better contrast-to-noise ratios for the anatomical features. Moreover, XGI excels in fidelity of the density measurements, and is also more robust against low-frequency artifacts than HT, but it might suffer from phase-wrapping artifacts. Thus, we can regard the three phase tomography methods discussed as complementary. The application will decide which spatial and density resolutions are desired, for the imaging task and dose requirements, and, in addition, the applicant must choose between the complexity of the experimental setup and the one of data processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-272: Direct Verification of a Treatment Planning System Megavoltage Linac Beam Photon Spectra Models, and Analysis of the Effects On Patient Plans

Purpose: For the photon dose calculation Philips Pinnacle Treatment Planning System (TPS) uses collapsed cone convolution algorithm, which relies on energy spectrum of the beam in computing the scatter component. The spectrum is modeled based on Linac’s standard commissioning data and typically is not independently verified. We explored a methodology of using transmission measurements in combination with regularization data processing to unfold Linac spectra. The measured spectra were compared to those modeled by the TPS, and the effect on patient plans was evaluated. Methods: Transmission measurements were conducted in narrow-beam geometry using a standard Farmer ionization chamber. Two attenuating materials and two build -up caps, having different atomic numbers, served to enhance discrimination between absorption of low and high-energy portions of the spectra, thus improving the accuracy of the results. The data was analyzed using a regularization technique implemented through spreadsheet-based calculations. Results: The unfolded spectra were found to deviate from the TPS beam models. The effect of such deviations on treatment planning was evaluated for patient plans through dose distribution calculations with either TPS modeled or measured energy spectra. The differences were reviewed through comparison of isodose distributions, and quantified based on maximum dose values for critical structures. While in most cases no drastic differences in the calculated doses were observed, plans with deviations of 4 to 8% in the maximum dose values for critical structures were discovered. The anatomical sites with large scatter contributions are the most vulnerable to inaccuracies in the modeled spectrum. Conclusion: An independent check of the TPS model spectrum is highly desirable and should be included as part of commissioning of a new Linac. The effect is particularly important for dose calculations in high heterogeneity regions. The developed approach makes acquisition of megavoltage Linac beam spectra achievable in a typical radiation oncology clinic.

60 APPLIED LIFE SCIENCES↗

Approximate recoverability and relative entropy II: 2-positive channels of general von Neumann algebras

Abstract We generalize our results in paper I in this series to quantum channels between general von Neumann algebras, proving the approximate recoverability of states which undergo a small change in relative entropy through the channel. To this end, we derive a strengthened form of the quantum data processing inequality for the change in relative entropy of two states under a channel between two von Neumann algebras. Compared to the usual inequality, there is an explicit lower bound involving the fidelity between the original state and a recovery channel.

97 MATHEMATICS AND COMPUTING↗

Beyond integration: modeling every pixel to obtain better structure factors from stills

Most crystallographic data processing methods use pixel integration. In serial femtosecond crystallography (SFX), the intricate interaction between the reciprocal lattice point and the Ewald sphere is integrated out by averaging symmetrically equivalent observations recorded across a large number (10 4 -10 6 ) of exposures. Although sufficient for generating biological insights, this approach converges slowly, and using it to accurately measure anomalous differences has proved difficult. This report presents a novel approach for increasing the accuracy of structure factors obtained from SFX data. A physical model describing all observed pixels is defined to a degree of complexity such that it can decouple the various contributions to the pixel intensities. Model dependencies include lattice orientation, unit-cell dimensions, mosaic structure, incident photon spectra and structure factor amplitudes. Maximum likelihood estimation is used to optimize all model parameters. The application of prior knowledge that structure factor amplitudes are positive quantities is included in the form of a reparameterization. The method is tested using a synthesized SFX dataset of ytterbium(III) lysozyme, where each X-ray laser pulse energy is centered at 9034 eV. This energy is 100 eV above the Yb 3+ L -III absorption edge, so the anomalous difference signal is stable at 10 electrons despite the inherent energy jitter of each femtosecond X-ray laser pulse. This work demonstrates that this approach allows the determination of anomalous structure factors with very high accuracy while requiring an order-of-magnitude fewer shots than conventional integration-based methods would require to achieve similar results.

59 BASIC BIOLOGICAL SCIENCES↗

Note: Switching crosstalk on and off in Kelvin probe force microscopy

In Kelvin Probe Force Microscopy (KPFM) electronic crosstalk can occur between the excitation signal and probe deflection signal. Here, we demonstrate how a small modification to our commercial instrument enables us to literally switch the crosstalk on and off. We study in detail the effect of crosstalk on open-loop KPFM and compare with closed-loop KPFM. We measure the pure crosstalk signal and verify that we can correct for it in the data-processing required for open-loop KPFM. We also demonstrate that open-loop KPFM results are independent of the frequency and amplitude of the excitation signal, provided that the influence of crosstalk has been eliminated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visual Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis (Milestone Report)

In 1997, an uncertainty analysis was conducted of the Video Scanning Hartmann Optical Tester (VSHOT). In 2010, we have completed a new analysis, based primarily on the geometric optics of the system, and it shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic troughmirror panel test. These help to guide the operator in proper setup, and help end-users to understand the data they are provided. We include both the systematic (bias) and random (precision) errors for VSHOT testing and their contributions to the uncertainty. The contributing factors we considered in this study are: target tilt; target face to laser output distance; instrument vertical offset;laser output angle; distance between the tool and the test piece; camera calibration; and laser scanner. These contributing factors were applied to the calculated slope error, focal length, and test article tilt that are generated by the VSHOT data processing. Results show the estimated 2-sigma uncertainty in slope error for a parabolic trough line scan test to be +/-0.2 milliradians;uncertainty in the focal length is +/- 0.1 mm, and the uncertainty in test article tilt is +/- 0.04 milliradians.

14 SOLAR ENERGY↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Sensor Suite

The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. When looking for a sensor that would provide XYZ point cloud data for mapping the decision was between a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The selection between Lidars is detailed. The Hokuyo UTM-30LX-EW shown provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg.. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. The rotating planar scan from the 2D Lidar can be stitched into a 3D scan as shown in the graphic below. Along with XYZ data, the Lidar provides return intensity data in color which can be used to distinguish between different materials within the tunnel. To provide visual feedback a camera system needed to be identified. The common solution for this is a high resolution camera with a small FOV mounted on a pan-tilt system. But, given the critical nature of the visual feedback we looked into solutions without the need for moving parts. Two panospheric cameras give a FOV large enough to get a full 360 deg. view.. Camera color data (RGB) can also be combined with the 3D mapping data from the Lidar and overlaid on the map to give the user the ability to see inside the entire length of the tunnel as if they were inside. Situational awareness is required for the crawler in the tunnel in order for it to be able to register the 3D scans to create a final map. For this we procured a Microstrain 3DM-GX5-25 Inertial Measurement Unit (IMU). To perform the Lidar rotation we have two servos driving the pan and tilt. The servo controls and most data processing will be performed via an onboard computer. The sensor components are to be packaged together using 3D printed mounts into a standalone unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synchrotron Area X-ray Detectors, Present and Future

X-ray experiments are very frequently detector limited at today's storage ring synchrotron radiation (SR) sources, and will be even more so at future Energy Recovery Linac and X-ray Free Electron Laser sources. Image plate and phosphor-coupled CCD detectors that predominate at present-day sources were outgrowths of technologies initially developed for the medical and astronomical communities, respectively, with resultant limitations for SR. These limitations are enumerated. The growth of commercial silicon foundries and design tools enabling the production of large, customized integrated circuits is beginning to have a profound impact on SR detectors and is ushering in the age of 'designer detectors'. Novel area Pixel Array Detectors (PADs) are starting to appear in which each pixel has dedicated, complex circuitry capable of high speed and, in some cases, significant data processing power for specific applications. PADs now at, or near the horizon will be described. Integrated circuit methods continue to develop at a rapid pace. Implications for future x-ray detectors will be discussed.

43 PARTICLE ACCELERATORS↗

A Scientific Data Provenance API for Distributed Applications

Data provenance has been an active area of research as a means to standardize how the origin of data, process event history, and what or who was responsible for influencing results is explained. There are two approaches to capture provenance information. The first approach is to collect observed evidence produced by an executing application using log files, event listeners, and temporary files that are used by the application or application developer. The provenance translated from these observations is an interpretation of the provided evidence. The second approach is called disclosed because the application provides a firsthand account of the provenance based on the anticipated questions on data flow, process flow, and responsible agents. Most observed provenance collection systems collect lot of provenance information during an application run or workflow execution. The common trend in capturing provenance is to collect all possible information, then attempt to find relevant information, which is not efficient. Existing disclosed provenance system APIs do not work well in distributed environment and have trouble finding where to fit the individual pieces of provenance information. This work focuses on determining more reliable solutions for provenance capture. As part of the Integrated End-to-end Performance Prediction and Diagnosis for Extreme Scientific Workflows (IPPD) project, an API was developed, called Producer API (PAPI), which can disclose application targeted provenance, designed to work in distributed environments by means of unique object identification methods. The provenance disclosure approach used adds additional metadata to the provenance information to uniquely identify the pieces and connect them together. PAPI uses a common provenance model to support this provenance integration across disclosure sources. The API also provides the flexibility to let the user decide what to do with the collected provenance. The collected provenance can be sent to a triple store using REST services or it can be logged to a file.

Raju, Bibi↗

Laser beam scattering on an inhomogeneous ensemble of elliptical discs modelling red blood cells in an ectacytometer

We have theoretically studied the effect of difference in particle shapes on the appearance of the diffraction pattern, which arises in the scattering of a laser beam on a dilute suspension of erythrocytes in an ectacytometer. We have proposed data processing algorithms allowing one to estimate the red blood cell shape parameter variance under conditions of laser ectacytometry. The conclusions of the theoretical analysis are verified experimentally. (laser methods in biology)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray refraction-contrast computed tomography images using dark-field imaging optics

If an x-ray beam containing internal information derived from sample soft tissue is incident upon a Laue-case analyzer, the beam will subsequently split into a forwardly diffracted beam and a separate diffracted beam. Using these beams acquired simultaneously, a refraction-contrast computed tomography (CT) imaging system for biomedical use with lower radiation dose can be easily realized, and has a high depicting capability on the soft tissues compared with conventional x-ray CT based on absorption contrast principles. In this paper, we propose an imaging system using dark-field imaging for CT measurement based on a tandem system of Bragg- and Laue-case crystals with two two-dimensional detectors, along with a data-processing method to extract information on refraction from the measured entangled intensities by use of rocking curve fitting with polynomial functions. Reconstructed images of soft tissues are presented and described.

07 ISOTOPE AND RADIATION SOURCES↗

MapReduce SVM Game

Despite technological advances making computing devices faster, smaller, and more prevalent in today's age, data generation and collection has outpaced data processing capabilities. Simply having more compute platforms does not provide a means of addressing challenging problems in the big data era. Rather, alternative processing approaches are needed and the application of machine learning to big data is hugely important. The MapReduce programming paradigm is an alternative to conventional supercomputing approaches, and requires less stringent data passing constrained problem decompositions. Rather, MapReduce relies upon defining a means of partitioning the desired problem so that subsets may be computed independently and recom- bined to yield the net desired result. However, not all machine learning algorithms are amenable to such an approach. Game-theoretic algorithms are often innately distributed, consisting of local interactions between players without requiring a central authority and are iterative by nature rather than requiring extensive retraining. Effectively, a game-theoretic approach to machine learning is well suited for the MapReduce paradigm and provides a novel, alternative new perspective to addressing the big data problem. In this paper we present a variant of our Support Vector Machine (SVM) Game classifier which may be used in a distributed manner, and show an illustrative example of applying this algorithm.

97 MATHEMATICS AND COMPUTING↗

Measurement of electron density with the phase-resolved cut-off probe method

The phase resolved cut-off probe method, a precise measurement method for the electron density, was recently proposed [J. H. Kwon et al., Appl. Phys. Lett. 96, 081502 (2010)]. This paper presents the measurements of electron density using the method under various experimental conditions (different pressures, powers, chamber volumes, and discharge sources). The result shows that the method is not only in good agreement with the previous method using wave transmittance under various experimental conditions but it is also able to find the cut-off point clearly even under difficult conditions such as high pressure ({approx} 1 Torr), high discharge power, and small plasma volume. The details of the experimental setup, the operating mechanism of the probe method, and the data processing procedure (algorithm) are also addressed. Furthermore, the reliability of the measurement method is investigated by using an electromagnetic field simulation with cold plasma model (CST-Drude model, Computer Simulation Technology).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Many-core applications to online track reconstruction in HEP experiments

Interest in parallel architectures applied to real time selections is growing in High Energy Physics (HEP) experiments. In this paper we describe performance measurements of Graphic Processing Units (GPUs) and Intel Many Integrated Core architecture (MIC) when applied to a typical HEP online task: the selection of events based on the trajectories of charged particles. We use as benchmark a scaled-up version of the algorithm used at CDF experiment at Tevatron for online track reconstruction – the SVT algorithm – as a realistic test-case for low-latency trigger systems using new computing architectures for LHC experiment. We examine the complexity/performance trade-off in porting existing serial algorithms to many-core devices. Measurements of both data processing and data transfer latency are shown, considering different I/O strategies to/from the parallel devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast entanglement detection for unknown states of two spatial qutrits

We investigate the practicality of the method proposed by Maciel et al. [Phys. Rev. A. 80, 032325 (2009).] for detecting the entanglement of two spatial qutrits (three-dimensional quantum systems), which are encoded in the discrete transverse momentum of single photons transmitted through a multislit aperture. The method is based on the acquisition of partial information of the quantum state through projective measurements, and a data processing analysis done with semidefinite programs. This analysis relies on generating gradually an optimal entanglement witness operator, and numerical investigations have shown that it allows for the entanglement detection of unknown states with a cost much lower than full state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient generation of single and entangled photons on a silicon photonic integrated chip

We present a protocol for generating on-demand, indistinguishable single photons on a silicon photonic integrated chip. The source is a time-multiplexed spontaneous parametric down-conversion element that allows optimization of single-photon versus multiphoton emission while realizing high output rate and indistinguishability. We minimize both the scaling of active elements and the scaling of active element loss with multiplexing. We then discuss detection strategies and data processing to further optimize the procedure. We simulate an improvement in single-photon-generation efficiency over previous time-multiplexing protocols, assuming existing fabrication capabilities. We then apply this system to generate heralded Bell states. The generation efficiency of both nonclassical states could be increased substantially with improved fabrication procedures.

74 ATOMIC AND MOLECULAR PHYSICS↗

Diffusion motions in hydrated sodium alginate by QENS

QENS experiments are very suitable for the study of water-polysaccharides systems both for slow polymer chains dynamics as well as for faster solvent molecules dynamics. By a suitable choice of experimental conditions as well as a properly data processing we can get information about the motion modes of various molecular groups of polymer chains in aqueous solutions presumes. Virtually we can distinguish the polymer protons motions at nanosecond time scale by choosing a narrow energy resolution window. The present work presents the QENS measurements performed at LLB, MIBEMOL neutron spectrometer on sodium alginate hydrated samples. The experimental spectra were fitted using one lorentzian fit. At high polymer concentration the quasielastic part of the line is given by the translational-rotational diffusion performed by heavy water molecules in confined spaces created by the polymer coils. The experimental data are well described by Chudley Elliot and Hall-Ross models.

36 MATERIALS SCIENCE↗

A novel technique for real-time estimation of edge pedestal density gradients via reflectometer time delay data

A new model-based technique for fast estimation of the pedestal electron density gradient has been developed. The technique uses ordinary mode polarization profile reflectometer time delay data and does not require direct profile inversion. Because of its simple data processing, the technique can be readily implemented via a Field-Programmable Gate Array, so as to provide a real-time density gradient estimate, suitable for use in plasma control systems such as envisioned for ITER, and possibly for DIII-D and Experimental Advanced Superconducting Tokamak. The method is based on a simple edge plasma model with a linear pedestal density gradient and low scrape-off-layer density. By measuring reflectometer time delays for three adjacent frequencies, the pedestal density gradient can be estimated analytically via the new approach. Using existing DIII-D profile reflectometer data, the estimated density gradients obtained from the new technique are found to be in good agreement with the actual density gradients for a number of dynamic DIII-D plasma conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗