Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

Here, the ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific pro-ductivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of Cþþ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms.

detector simulation↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

Electron/hadron separation with the TRD based on GaAs pixel detectors

Transition Radiation Detectors (TRDs) are widely used for particle identification in both high-energy physics and astroparticle physics. They are typically equipped with gaseous detectors. The main limitation of these types of detectors is that TR photons and ionization losses cannot be decoupled, which significantly reduces the particle separation power. Recent advancements in the development of pixel detectors based on GaAs sensors offer a unique opportunity to effectively detect TR photons and separate them from ionization losses. Such detectors represent novel devices that combine precise tracking capabilities with particle identification (PID) properties. The present work is dedicated to an experimental study of particle identification properties of the TRD prototype based on 500 μ m-thick GaAs sensor bonded to a Timepix3 chip. Studies were performed at the CERN SPS and it was shown that at a particle momentum of 20 GeV/c, the probability of misidentifying a hadron as an electron is below 10 −2 for an electron detection efficiency of 98%–99%, and it is 1 . 6⋅10 −4 for electron detection efficiency of 90%. This performance surpasses the electron/hadron rejection power of all known TRDs by an order of magnitude for the same detector length.

GaAs detectors↗

2D perovskite-based high spatial resolution X-ray detectors

Abstract X-ray radiography is the most widely used imaging technique with applications encompassing medical and industrial imaging, homeland security, and materials research. Although a significant amount of research and development has gone into improving the spatial resolution of the current state-of-the-art indirect X-ray detectors, it is still limited by the detector thickness and microcolumnar structure quality. This paper demonstrates high spatial resolution X-ray imaging with solution-processable two-dimensional hybrid perovskite single-crystal scintillators grown inside microcapillary channels as small as 20 µm. These highly scalable non-hygroscopic detectors demonstrate excellent spatial resolution similar to the direct X-ray detectors. X-ray imaging results of a camera constructed using this scintillator show Modulation Transfer Function values significantly better than the current state-of-the-art X-ray detectors. These structured detectors open up a new era of low-cost large-area ultrahigh spatial resolution high frame rate X-ray imaging with numerous applications.

2D perovskite↗

Thin film cadmium telluride charged particle sensors for large area neutron detectors

Thin film semiconductor neutron detectors are an attractive candidate to replace {sup 3}He neutron detectors, due to the possibility of low cost manufacturing and the potential for large areas. Polycrystalline CdTe is found to be an excellent material for thin film charged particle detectors—an integral component of a thin film neutron detector. The devices presented here are characterized in terms of their response to alpha and gamma radiation. Individual alpha particles are detected with an intrinsic efficiency of >80%, while the devices are largely insensitive to gamma rays, which is desirable so that the detector does not give false positive counts from gamma rays. The capacitance-voltage behavior of the devices is studied and correlated to the response due to alpha radiation. When coupled with a boron-based neutron converting material, the CdTe detectors are capable of detecting thermal neutrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nuclear recoil scintillation linearity of a high pressure 4 He gas detector

We investigate scintillation linearity of a commercial high pressure 4 He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a range of recoil energies between 83 keV and 626 keV by tagging neutrons scattering into fixed angles with a far-side organic scintillator detector. Detailed Monte Carlo simulations were compared to experimental data to determine the linearity of the detector response by comparing the scaling of the energy deposits in the simulations to the detector output. In this analysis, a linear scintillation response corresponds to a consistent value for the scaling factor between simulated energy deposits and experimental data for several different scattering angles. Here we demonstrate that the detector can be used to detect fast neutron interactions down to 83 keV recoil energies and can be used to characterize low-energy neutron sources, one of its potential applications.

47 OTHER INSTRUMENTATION↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI-optimized detector design for the future Electron-Ion Collider: the dual-radiator RICH case

Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. Here, we propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development as a potential component of the particle-identification system at the future Electron-Ion Collider (EIC). The EIC is a US-led frontier accelerator project for nuclear physics, which has been proposed to further explore the structure and interactions of nuclear matter at the scale of sea quarks and gluons. We show that the detector design obtained with our automated and highly parallelized framework outperforms the baseline dRICH design within the assumptions of the current model. Our technique can be applied to any detector R&D, provided that realistic simulations are available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance study of charcoal-based radon reduction systems for ultraclean rare event detectors

The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. 222 Rn produces a particularly problematic background in the physics region of interest by the "naked" beta decay of its 214 Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current ton-scale detectors at slow flow rates (0.5-2 SLPM), radon reduction in the entire circulation loop at high flow rates $\mathcal{O}$(100s SLPM) is necessary to reach high sensitivity in future generation experiments. In this article we explore radon dynamics with a charcoal-based radon reduction system in the main circulation loop of time projection chamber detectors. Here, we find that even for perfect radon traps, circulation speeds of 2,000 SLPM are needed to reduce radon concentration in a 10 ton detector by 90%. This is faster by a factor of four than the highest circulation speeds currently achieved in dark matter detectors. We further find that the effectiveness of vacuum swing adsorption systems, which have been employed very successfully at reducing atmospheric radon levels in clean-rooms, is limited by the intrinsic radon activity of the charcoal adsorbent in ultra-low radon environments. Adsorbents with significantly lower intrinsic radon activity than in currently available activated charcoals would be necessary to build effective vacuum swing adsorption systems operated at room temperature for rare event search experiments. If such VSA systems are cooled to about 190 K, this requirement relaxes drastically.

47 OTHER INSTRUMENTATION↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ePix10k 2-megapixel hard X-ray detector at LCLS

The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel −1 pulse −1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

Enhanced Cross-Correlation Inter-Detector Timing

Inter-detector timing is one of the key steps for compositing signals obtained by multiple detectors. Conventionally this is done via inversing time gamma functions of individual detectors and then matching their times at the same gamma level. The applicability of the gamma inverse approach is often restricted to the monotonic gamma functions. This presentation presents a novel approach for inter-detector timing. This new approach introduced an enhanced cross-correlation of gamma values between two time intervals of two detectors. If this enhanced cross-correlation is close to 1, then both intervals should cover the same gamma segment of the signal. Consequently the time shift between the two detector can be derived from the time shift of the these two time intervals. This work will be presented at the 4th Annual Reaction History Analysis Workshop in North Las Vegas.

97 MATHEMATICS AND COMPUTING↗

Verification of Special Nuclear Material (SNM) using Active Well Coincidence Counter (AWCC) and a High Purity Germanium (HPGe) Detector

SNM verification can be accomplished via two methods i.e. destructive analysis (DA) or nondestructive analysis (NDA). The DA modes are much more accurate compared to NDA modes; nevertheless, the sample's physical integrity is destroyed in the process. Techniques such as ICP-MS, ID-ICP-MS, TI-MS are few examples of DA, where a bulk material is ground and mixed with a solution (some form of acid) to acquire a homogenous sample. In contrast, NDA modes utilize signals emitted by the sample such as gamma, neutrons, light, or heat to analyze samples under investigation. HPGe detectors are some of the most frequently used gamma detectors to assay SNM. However, in a high activity scenario it provides a large uncertainty and sometimes becomes unfeasible to measure low energy gamma rays. Meanwhile, neutron detectors are not affected by the gamma background, therefore they can be used in addition to the gamma detectors to verify total fissile mass ({sup 235}U + {sup 239}Pu) of SNM. The AWCC is one of the thermal neutron NDA systems developed at the Los Alamos National Laboratory (LANL). It consists of 42 {sup 3}He detectors to measure gross neutrons (singles), coincidence neutrons (doubles), higher order multiplicity counting (triples, quadruples, etc.). It can effectively operate in both active and passive neutron interrogation modes. It can utilize AmLi, AmBe, or {sup 252}Cf active interrogation neutron sources. It is used to verify declared fissile mass ({sup 235}U or {sup 239}Pu) present in SNM. Objectives: Calibrate HPGe and AWCC for lightly irradiated (with enough {sup 137}Cs gamma background) ∼93% enriched HEU fuels; Verify fissile mass ({sup 235}U +{sup 239}Pu) content using AWCC and HPGe; Model and benchmark AWCC in MCNP6. Neutron coincidence and multiplicity counting: Two or more neutrons are coincident if they are detected by the system within the specified gate window; In AWCC: Gate window is 128 μsec; Induced fission in fissile material such as {sup 235}U and {sup 239}Pu - emission of time correlated neutrons - Singles, Doubles, Triples, or Quadruples; No induced fission in non-fissile materials- no correlated neutrons - only singles. SNM can be verified with high accuracy and precision using gamma and neutron NDA instruments such as HPGe and AWCC. Interaction with thermal neutrons. Non-fissile atoms - do not emit correlated neutrons. Fissile atoms - emit correlated neutrons during induced fission events. The time correlated neutrons can be detected by using coincidence or multiplicity counters such as AWCC. Likewise, {sup 235}U produces 186 keV gamma peak that can be measured by a HPGe gamma detector. Counts under 186 keV gamma peak provide information about {sup 235}U content. Combining AWCC and HPGe results can provide better understanding of special nuclear material under investigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors

Here, we present results of beam tests of charged particle detectors based on single-crystal and poly-crystalline Chemical Vapor Deposition (CVD) diamond. We measured the signal pulse height dependence on the particle flux. The detectors were tested over a range of particle fluxes from 2 kHz/cm 2 to 20 MHz/cm 2 . The pulse height of the sensors was measured with pad and pixel readout electronics. The pulse height of the non-irradiated single-crystal CVD diamond pad sensors was stable with respect to flux, while the pulse height of irradiated single-crystal CVD diamond pad sensors decreased with increasing particle flux. The pulse height of the non-irradiated single-crystal CVD diamond pixel detectors decreased slightly with increasing particle flux while the pulse height of the irradiated single-crystal CVD diamond pixel detectors decreased significantly with increasing particle flux. The observed sensitivity to flux is similar in both the diamond pad sensors constructed using diamonds from the Pixel Luminosity Telescope (PLT) irradiated during its pilot run in the Compact Muon Solenoid (CMS) detector and in neutron irradiated diamond pad sensors from the same manufacturer irradiated to the same fluence of neutrons. The pulse height for irradiated poly-crystalline CVD diamond pad sensors proved to be stable with respect to particle flux.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed X-ray imaging pixel array detector for synchrotron bunch isolation

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. Lastly, we detail the characteristics, operation, testing and application of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methylammonium Lead Tribromide Single Crystal Detectors towards Robust Gamma-Ray Photon Sensing

In recent years, hybrid perovskite single crystalline solid-state detectors have shown promise in γ-ray spectroscopy. Here, the γ-ray photon induced electrical pulses are investigated, which are produced by perovskite solid-state detectors made with the commonly used methylammonium lead tribromide crystals with chlorine incorporation. Under low electric field detector operation, slow pulses generated by γ-rays with average rise times of 65 µs are observed, which decreases to 20 µs when a higher electrical field of 500 V cm -1 is applied. However, the baseline becomes noisy quickly, which prevents collection of clean pulses for spectra construction. Further, by systematically measuring the temperature dependence and current–voltage characteristics, such instability is attributed to the local ion migration under electrical field creating a fluctuating dark noise, which presents a major challenge in perovskite γ-ray detector technologies. It is demonstrated that cycling the bias between positive and negative polarity can stabilize the detector, allowing for longer periods of pulse accumulation for generating energy resolved spectra with resolutions of ≈35% at 59.6 keV and ≈25% at 662 keV at room temperature. The study indicates that the main limiting factors of perovskite-based γ-ray detectors are slow rise times and bias instability. Finally, these challenges must be properly addressed to achieve reproducible, high-resolution γ-ray detection.

47 OTHER INSTRUMENTATION↗

A fast method for optical simulation of flood maps of light-sharing detector modules

Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. Here, we present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We also simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. And while the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗