Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

ON THE ROAD TO MORE REALISTIC GALAXY CLUSTER SIMULATIONS: THE EFFECTS OF RADIATIVE COOLING AND THERMAL FEEDBACK PRESCRIPTIONS ON THE OBSERVATIONAL PROPERTIES OF SIMULATED GALAXY CLUSTERS

Flux-limited X-ray surveys of galaxy clusters show that clusters come in two roughly equally proportioned varieties: 'cool core' clusters (CCs) and non-'cool core' clusters (NCCs). In previous work, we have demonstrated using cosmological N-body + Eulerian hydrodynamic simulations that NCCs are often consistent with early major merger events that destroy embryonic CCs. In this paper we extend those results and conduct a series of simulations using different methods of gas cooling and of energy and metal feedback from supernovae, where we attempt to produce a population of clusters with realistic central cooling times, entropies, and temperatures. We find that the use of metallicity-dependent gas cooling is essential to prevent early overcooling, and that adjusting the amount of energy and metal feedback can have a significant impact on observable X-ray quantities of the gas. We are able to produce clusters with more realistic central observable quantities than have previously been attained. However, there are still significant discrepancies between the simulated clusters and observations, which indicates that a different approach to simulating galaxies in clusters is needed. We conclude by looking toward a promising subgrid method of modeling galaxy feedback in clusters that may help to ameliorate the discrepancies between simulations and observations.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE INITIAL MASS FUNCTION OF LOW-METALLICITY STARS: THE IMPORTANCE OF DUST COOLING

The first stars to form in the universe are believed to have distribution of masses biased toward massive stars. This contrasts with the present-day initial mass function, which has a predominance of stars with masses lower than 1 M{sub Sun }. Therefore, the mode of star formation must have changed as the universe evolved. Such a transition is attributed to a more efficient cooling provided by increasing metallicity. Especially dust cooling can overcome the compressional heating, which lowers the gas temperature thus increasing its instability to fragmentation. The purpose of this paper is to verify if dust cooling can efficiently cool the gas, and enhance the fragmentation of gas clouds at the early stages of the universe. To confirm that, we calculate a set of hydrodynamic simulations that include sink particles, which represent contracting protostars. The thermal evolution of the gas during the collapse is followed by making use of a primordial chemical network and also a recipe for dust cooling. We model four clouds with different amounts of metals (10{sup -4}, 10{sup -5}, 10-6 Z{sub Sun }, and 0), and analyze how this property affect the fragmentation of star-forming clouds. We find evidence for fragmentation in all four cases, and hence conclude that there is no critical metallicity below which fragmentation is impossible. Nevertheless, there is a clear change in the behavior of the clouds at Z {approx}< 10{sup -5} Z{sub Sun }, caused by the fact that at this metallicity, fragmentation takes longer to occur than accretion, leading to a flat mass function at lower metallicities.

79 ASTRONOMY AND ASTROPHYSICS↗

SEARCHING FOR COOLING SIGNATURES IN STRONG LENSING GALAXY CLUSTERS: EVIDENCE AGAINST BARYONS SHAPING THE MATTER DISTRIBUTION IN CLUSTER CORES

The process by which the mass density profile of certain galaxy clusters becomes centrally concentrated enough to produce high strong lensing (SL) cross-sections is not well understood. It has been suggested that the baryonic condensation of the intracluster medium (ICM) due to cooling may drag dark matter to the cores and thus steepen the profile. In this work, we search for evidence of ongoing ICM cooling in the first large, well-defined sample of SL selected galaxy clusters in the range 0.1 < z < 0.6. Based on known correlations between the ICM cooling rate and both optical emission line luminosity and star formation, we measure, for a sample of 89 SL clusters, the fraction of clusters that have [O II]{lambda}{lambda}3727 emission in their brightest cluster galaxy (BCG). We find that the fraction of line-emitting BCGs is constant as a function of redshift for z > 0.2 and shows no statistically significant deviation from the total cluster population. Specific star formation rates, as traced by the strength of the 4000 A break, D{sub 4000}, are also consistent with the general cluster population. Finally, we use optical imaging of the SL clusters to measure the angular separation, R{sub arc}, between the arc and the center of mass of each lensing cluster in our sample and test for evidence of changing [O II] emission and D{sub 4000} as a function of R{sub arc}, a proxy observable for SL cross-sections. D{sub 4000} is constant with all values of R{sub arc}, and the [O II] emission fractions show no dependence on R{sub arc} for R{sub arc} > 10'' and only very marginal evidence of increased weak [O II] emission for systems with R{sub arc} < 10''. These results argue against the ability of baryonic cooling associated with cool core activity in the cores of galaxy clusters to strongly modify the underlying dark matter potential, leading to an increase in SL cross-sections.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct observations of plasma upflows and condensation in a catastrophically cooling solar transition region loop

Minimal observational evidence exists for fast transition region (TR) upflows in the presence of cool loops. Observations of such occurrences challenge notions of standard solar atmospheric heating models as well as their description of bright TR emission. Using the EUV Imaging Spectrometer on board Hinode, we observe fast upflows (v {sub λ} ≤ –10 km s{sup –1}) over multiple TR temperatures (5.8 ≤log T ≤ 6.0) at the footpoint sites of a cool loop (log T ≤ 6.0). Prior to cool loop energizing, asymmetric flows of +5 km s{sup –1} and –60 km s{sup –1} are observed at footpoint sites. These flows, speeds, and patterns occur simultaneously with both magnetic flux cancellation (at the site of upflows only) derived from the Solar Dynamics Observatory's Helioseismic Magnetic Imager's line-of-sight magnetogram images, and a 30% mass influx at coronal heights. The incurred non-equilibrium structure of the cool loop leads to a catastrophic cooling event, with subsequent plasma evaporation indicating that the TR is the heating site. From the magnetic flux evolution, we conclude that magnetic reconnection between the footpoint and background field is responsible for the observed fast TR plasma upflows.

79 ASTRONOMY AND ASTROPHYSICS↗

Forming chondrules in impact splashes. I. Radiative cooling model

The formation of chondrules is one of the oldest unsolved mysteries in meteoritics and planet formation. Recently an old idea has been revived: the idea that chondrules form as a result of collisions between planetesimals in which the ejected molten material forms small droplets that solidify to become chondrules. Pre-melting of the planetesimals by radioactive decay of {sup 26}Al would help produce sprays of melt even at relatively low impact velocity. In this paper we study the radiative cooling of a ballistically expanding spherical cloud of chondrule droplets ejected from the impact site. We present results from numerical radiative transfer models as well as analytic approximate solutions. We find that the temperature after the start of the expansion of the cloud remains constant for a time t {sub cool} and then drops with time t approximately as T ≅ T {sub 0}[(3/5)t/t {sub cool} + 2/5]{sup –5/3} for t > t {sub cool}. The time at which this temperature drop starts t {sub cool} depends via an analytical formula on the mass of the cloud, the expansion velocity, and the size of the chondrule. During the early isothermal expansion phase the density is still so high that we expect the vapor of volatile elements to saturate so that no large volatile losses are expected.

79 ASTRONOMY AND ASTROPHYSICS↗

MECHANISM OF OUTFLOWS IN ACCRETION SYSTEM: ADVECTIVE COOLING CANNOT BALANCE VISCOUS HEATING?

Based on the no-outflow assumption, we investigate steady-state, axisymmetric, optically thin accretion flows in spherical coordinates. By comparing the vertically integrated advective cooling rate with the viscous heating rate, we find that the former is generally less than 30% of the latter, which indicates that the advective cooling itself cannot balance the viscous heating. As a consequence, for radiatively inefficient flows with low accretion rates such as M-dot ≲10{sup −3} M-dot {sub Edd}, where M-dot {sub Edd} is the Eddington accretion rate, the viscous heating rate will be larger than the sum of the advective cooling rate and the radiative cooling one. Thus, no thermal equilibrium can be established under the no-outflow assumption. We therefore argue that in such cases outflows ought to occur and take away more than 70% of the thermal energy generated by viscous dissipation. Similarly, for optically thick flows with extremely large accretion rates such as M-dot ≳10 M-dot {sub Edd}, outflows should also occur owing to the limited advection and the low efficiency of radiative cooling. Our results may help to understand the mechanism of outflows found in observations and numerical simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EFFECT OF DUST COOLING ON LOW-METALLICITY STAR-FORMING CLOUDS

The theory for the formation of the first population of stars (Pop. III) predicts an initial mass function (IMF) composed predominantly of high-mass stars, in contrast to the present-day IMF, which tends to yield stars with masses less than 1 M{sub sun}. The leading theory for the transition in the characteristic stellar mass predicts that the cause is the extra cooling provided by increasing metallicity and in particular the cooling provided at high densities by dust. The aim of this work is to test whether dust cooling can lead to fragmentation and be responsible for this transition. To investigate this, we make use of high-resolution hydrodynamic simulations. We follow the thermodynamic evolution of the gas by solving the full thermal energy equation and also track the evolution of the dust temperature and the chemical evolution of the gas. We model clouds with different metallicities and determine the properties of the cloud at the point at which it undergoes gravitational fragmentation. We follow the further collapse to scales of an AU when we replace very dense, gravitationally bound, and collapsing regions by a simple and nongaseous object, a sink particle. Our results suggest that for metallicities as small as 10{sup -5} Z{sub sun}, dust cooling produces low-mass fragments and hence can potentially enable the formation of low-mass stars. We conclude that dust cooling affects the fragmentation of low-metallicity gas clouds and plays an important role in shaping the stellar IMF even at these very low metallicities.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE COOLING TAILS OF THERMONUCLEAR X-RAY BURSTS: THE IGR J17480-2446 LINK

The neutron star transient and 11 Hz X-ray pulsar IGR J17480-2446, recently discovered in the globular cluster Terzan 5, showed unprecedented bursting activity during its 2010 October-November outburst. We analyzed all X-ray bursts detected with the Rossi X-ray Timing Explorer and find strong evidence that they all have a thermonuclear origin, despite the fact that many do not show the canonical spectral softening along the decay imprinted on type I X-ray bursts by the cooling of the neutron star photosphere. We show that the persistent-to-burst power ratio is fully consistent with the accretion-to-thermonuclear efficiency ratio along the whole outburst, as is typical for type I X-ray bursts. The burst energy, peak luminosity, and daily-averaged spectral profiles all evolve smoothly throughout the outburst, in parallel with the persistent (non-burst) luminosity. We also find that the peak-burst to persistent luminosity ratio determines whether or not cooling is present in the bursts from IGR J17480-2446, and argue that the apparent lack of cooling is due to the 'non-cooling' bursts having both a lower peak temperature and a higher non-burst (persistent) emission. We conclude that the detection of cooling along the decay is a sufficient, but not a necessary condition to identify an X-ray burst as thermonuclear. Finally, we compare these findings with X-ray bursts from other rapidly accreting neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

HST-COS SPECTROSCOPY OF THE COOLING FLOW IN A1795—EVIDENCE FOR INEFFICIENT STAR FORMATION IN CONDENSING INTRACLUSTER GAS

We present far-UV spectroscopy from the Cosmic Origins Spectrograph on the Hubble Space Telescope of a cool, star-forming filament in the core of A1795. These data, which span 1025 Å < λ{sub rest} < 1700 Å, allow for the simultaneous modeling of the young stellar populations and the intermediate-temperature (10{sup 5.5} K) gas in this filament, which is far removed (∼30 kpc) from the direct influence of the central active galactic nucleus. Using a combination of UV absorption line indices and stellar population synthesis modeling, we find evidence for ongoing star formation, with the youngest stars having ages of 7.5{sub −2.0}{sup +2.5} Myr and metallicities of 0.4{sub −0.1}{sup +0.2} Z {sub ☉}. The latter is consistent with the local metallicity of the intracluster medium. We detect the O VI λ1038 line, measuring a flux of f {sub O} {sub VI,} {sub 1038} = 4.0 ± 0.9 × 10{sup –17} erg s{sup –1} cm{sup –2}. The O VI λ1032 line is redshifted such that it is coincident with a strong Galactic H{sub 2} absorption feature, and is not detected. The measured O VI λ1038 flux corresponds to a cooling rate of 0.85 ± 0.2 (stat) ± 0.15 (sys) M {sub ☉} yr{sup –1} at ∼10{sup 5.5} K, assuming that the cooling proceeds isochorically, which is consistent with the classical X-ray luminosity-derived cooling rate in the same region. We measure a star formation rate of 0.11 ± 0.02 M {sub ☉} yr{sup –1} from the UV continuum, suggesting that star formation is proceeding at 13{sub −2}{sup +3}% efficiency in this filament. We propose that this inefficient star formation represents a significant contribution to the larger-scale cooling flow problem.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimized evaporative cooling for sodium Bose-Einstein condensation against three-body loss

We report on a highly efficient evaporative cooling optimized experimentally. We successfully created sodium Bose-Einstein condensates with 6.4x10{sup 7} atoms starting from 6.6x10{sup 9} thermal atoms trapped in a magnetic trap by employing a fast linear sweep of radio frequency at the final stage of evaporative cooling so as to overcome the serious three-body losses. The experimental results such as the cooling trajectory and the condensate growth quantitatively agree with the numerical simulations of evaporative cooling on the basis of the kinetic theory of a Bose gas carefully taking into account our specific experimental conditions. We further discuss theoretically a possibility of producing large condensates, more than 10{sup 8} sodium atoms, by simply increasing the number of initial thermal trapped atoms and the corresponding optimization of evaporative cooling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

Magnets for Muon 6D Cooling Channels

The Helical Cooling Channel (HCC), an innovative technique for six-dimensional (6D) cooling of muon beams using a continuous absorber inside superconducting magnets, has shown considerable promise based on analytic and simulation studies. The implementation of this revolutionary method of muon cooling requires high field superconducting magnets that provide superimposed solenoid, helical dipole, and helical quadrupole fields. Novel magnet design concepts are required to provide HCC magnet systems with the desired fields for 6D muon beam cooling. New designs feature simple coil configurations that produce these complex fields with the required characteristics, where new high field conductor materials are particularly advantageous. The object of the program was to develop designs and construction methods for HCC magnets and design a magnet system for a 6D muon beam cooling channel. If successful the program would develop the magnet technologies needed to create bright muon beams for many applications ranging from scientific accelerators and storage rings to beams to study material properties and new sources of energy. Examples of these applications include energy frontier muon colliders, Higgs and neutrino factories, stopping muon beams for studies of rare fundamental interactions and muon catalyzed fusion, and muon sources for cargo screening for homeland security.

43 PARTICLE ACCELERATORS↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gas-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model Updates

This work presents the latest improvements to, and investigations performed with, the pebble-bed high-temperature gas-cooled reactor (PB-HTGR) reference plant models for the United States Nuclear Regulatory Commission. These models serve as the foundation for the future development of detailed design evaluation models based on license applications. The reference plant models have been developed with the Comprehensive Reactor Analysis Bundle, or BlueCRAB, which is the code suite proposed for non-light-water reactor systems safety analysis. It incorporates various simulation tools developed by the Nuclear Energy Advanced Modeling and Simulation program, including the Griffin code for reactor physics, the Pronghorn and SAM codes for core thermal fluids, the BISON code for solid conduction and fuel performance, and the SAM code for system analysis. The primary objective of the work that was performed was to assess BlueCRAB’s level of readiness for modeling a PB-HTGR. To do so, we first developed numerical models in BlueCRAB that include the key physics for this technology to ensure an adequate level of fidelity for modeling PB-HTGR core performance and for performing multiphysics simulations for equilibrium core conditions and different accident scenarios. Then we simulated transient scenarios, including depressurized and pressurized loss of forced cooling accidents, over-cooling, and control rod withdrawal events with delayed and prompt supercritical reactivity insertions. The analysis in this report includes comparisons of the 2D thermal fluid porous media models in Pronghorn and SAM, and comparisons of coupled SAM/Griffin/SAM and coupled Pronghorn/Griffin for depressurized and pressurized loss of forced cooling, over-cooling, and control rod withdrawal events. In addition, we compare 3D, 2D, and 0D/PKE neutronic models for the two control rod withdrawal scenarios with coupled Pronghorn/Griffin. The comparisons show that the BlueCRAB models lead to physically intuitive solutions for the scenarios examined. The changes in the various scalar and vector fields, such as neutron flux, power, temperature, density, pressure, and velocity, are within the expected ranges, and their distributions can be explained by the system response of the transients and the geometric and material variations. Several comparisons suggest that the porous media models in Pronghorn and SAM can lead to similar solutions, even though they are based on different methodologies. This work further highlights the need for flexible tools with various levels of fidelity to cover the breadth and depth of needs that may arise in future technical evaluations of the PB-HTGR. We believe that the BlueCRAB capabilities will be a significant asset for confirmatory analyses in order to resolve important safety questions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Auto-DR and Pre-cooling of Buildings at Tri-City Corporate Center

Over the several past years, Lawrence Berkeley National Laboratory (LBNL) has conducted field tests for different pre-cooling strategies in different commercial buildings within California. The test results indicated that pre-cooling strategies were effective in reducing electric demand in these buildings during peak periods. This project studied how to optimize pre-cooling strategies for eleven buildings in the Tri-City Corporate Center, San Bernardino, California with the assistance of a building energy simulation tool -- the Demand Response Quick Assessment Tool (DRQAT) developed by LBNL's Demand Response Research Center funded by the California Energy Commission's Public Interest Energy Research (PIER) Program. From the simulation results of these eleven buildings, optimal pre-cooling and temperature reset strategies were developed. The study shows that after refining and calibrating initial models with measured data, the accuracy of the models can be greatly improved and the models can be used to predict load reductions for automated demand response (Auto-DR) events. This study summarizes the optimization experience of the procedure to develop and calibrate building models in DRQAT. In order to confirm the actual effect of demand response strategies, the simulation results were compared to the field test data. The results indicated that the optimal demand response strategies worked well for all buildings in the Tri-City Corporate Center. This study also compares DRQAT with other building energy simulation tools (eQUEST and BEST). The comparison indicate that eQUEST and BEST underestimate the actual demand shed of the pre-cooling strategies due to a flaw in DOE2's simulation engine for treating wall thermal mass. DRQAT is a more accurate tool in predicting thermal mass effects of DR events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring the Cooling Process for Residual Stress Reduction in Dissimilar Welds

Dissimilar metal welds are currently used in various industry applications; however, a significant number of failures have been reported in these joints due to the existence of large tensile residual stresses induced by arc welding processes. Hence, it is crucial to reduce or eliminate such residual stresses in dissimilar metal welds. Recently, modern techniques such as CO 2 rapid cooling have received attention by scholars to reduce residual stress in similar metal welds. Nevertheless, the effectivity of this technique has not been explored in dissimilar metal welds. In this paper, the impact of in-situ rapid local cooling in dissimilar metal welds is studied experimentally. The residual stresses of CO 2 -cooled welds were measured using the neutron diffraction technique. The effect of rapid cooling on the microstructure of the weld and heat-affected zones were examined. Finally, it is shown that for certain cases, in-situ rapid cooling during the arc welding process can minimize tensile residual stresses in dissimilar metal welds.

42 ENGINEERING↗

THE COOL SURGE FOLLOWING FLUX EMERGENCE IN A RADIATION-MHD EXPERIMENT

Cool and dense ejections, typically Hα surges, often appear alongside EUV or X-ray coronal jets as a result of the emergence of magnetized plasma from the solar interior. Idealized numerical experiments explain those ejections as being indirectly associated with the magnetic reconnection taking place between the emerging and preexisting systems. However, those experiments miss basic elements that can importantly affect the surge phenomenon. In this paper we study the cool surges using a realistic treatment of the radiation transfer and material plasma properties. To that end, the Bifrost code is used, which has advanced modules for the equation of state of the plasma, photospheric and chromospheric radiation transfer, heat conduction, and optically thin radiative cooling. We carry out a 2.5D experiment of the emergence of magnetized plasma through (meso) granular convection cells and the low atmosphere to the corona. Through detailed Lagrange tracing we study the formation and evolution of the cool ejection and, in particular, the role of the entropy sources; this allows us to discern families of evolutionary patterns for the plasma elements. In the launch phase, many elements suffer accelerations well in excess of gravity; when nearing the apex of their individual trajectories, instead, the plasma elements follow quasi-parabolic trajectories with accelerations close to g{sub ⊙}. We show how the formation of the cool ejection is mediated by a wedge-like structure composed of two shocks, one of which leads to the detachment of the surge from the original emerged plasma dome.

79 ASTRONOMY AND ASTROPHYSICS↗