Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compiler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Comparative Evaluation of Control-Oriented Heavy Duty Vehicle Air Drag Coefficient Models

Heavy-duty vehicles (HDVs) are a significant source of fuel consumption and greenhouse gas emissions, prompting solutions such as HDV platooning to mitigate these negative impacts through air drag reduction. The intervehicle distance in an HDV platoon needs to be carefully selected, such that the platoon-level energy efficiency and safety considerations can be well balanced. Underlying this problem lies in accurately modeling the relationship between HDV air drag coefficient and intervehicle distance. Through comprehensive evaluation and comparison, we analyze five control-oriented HDV air drag coefficient models, including the polynomial model, rational polynomial model, rational model, semi-quadratic model, and ridge model. Leveraging Scipy Curve-Fit toolbox and our previously compiled air drag coefficient datasets, we optimally identify the parameters inside each model. The calibrated models are then thoroughly evaluated via five complementary metrics. The comparison results reveal that the semi-quadratic model has the highest overall performance, while the widely adopted rational model only exhibits suboptimal performance.

Best, Micah↗

A multi-criteria CCUS screening evaluation of the Gulf of Mexico, USA

Continued research into reservoir characterization along with offshore carbon dioxide (CO 2 ) transportation and infrastructure assets is needed to facilitate development of safe and successful carbon capture, utilization, and storage (CCUS) projects. This paper outlines a multi-criteria evaluation methodology that incorporates disparate sets of quantitative, spatially variable data into a decision-making framework for screening the Gulf of Mexico (GOM) outer continental shelf (OCS) for potentially viable CO 2 storage and enhanced oil recovery (EOR) sites. Criteria categories include favorable geologic characteristics, logistics, and potential risks. Data compiled for 14 criteria from several publicly available geographic information system (GIS) layers was aggregated over 2559 spatially balanced points across the study area using the National Energy Technology Laboratory (NETL)-developed Cumulative Spatial Impact Layers™ (CSIL) GIS tool. Criteria are weighted by qualitative expert opinion relative to their perceived importance to given scenarios— the output of combined criteria values and weights enables regional CO 2 storage suitability differentiation. The methodology considers both technical and non-technical factors impacting CCUS decision-making. The flexible methodology enables a systematic approach to regional ranking at high spatial resolution over a large study domain. Additionally, the framework enables high-grading of priority sites that warrant further characterization and follow-on analysis. Areas along the Louisiana coast and Mississippi River Delta consistently rank high for all scenarios largely a result of the favorable geology with the potential for stacked storage, as well as the density of existing pipelines and platforms, and proximity to several onshore CO 2 sources. High-graded regions for the CO 2 EOR-related scenarios are typically located further offshore towards the middle and edge of the OCS compared to higher priority regions for the geologic storage scenarios which fall closer to the Louisiana coastline.

54 ENVIRONMENTAL SCIENCES↗

Using Hydrogen Safety Best Practices and Learning from Safety Events

A best practice is a technique or methodology that has reliably led to a desired result. A wealth of experience regarding the safe use and handling of hydrogen exists as a result of an extensive history in a wide variety of industrial and aerospace settings. Hydrogen Safety Best Practices (www.h2bestpractices.org) captures this vast knowledge base and makes it publically available to those working with hydrogen and related systems, including those just starting to work with hydrogen. This online manual is organized under a number of hierarchical technical content categories. References, including publications and other online links, that deal with the safety aspects of hydrogen are compiled for easy access. This paper discusses the development of Hydrogen Safety Best Practices as a safety knowledge tool, the nature of its technical content, and the steps taken to enhance its value and usefulness. Specific safety event examples are provided to illustrate the link between technical content in the online best practices manual and a companion safety knowledge tool, Hydrogen Incident Reporting and Lessons Learned (www.h2incidents.org), which encourages the sharing of lessons learned and other safety event information.

08 HYDROGEN↗

Assessing hydrogen supply chains: An integrated review of leakage and energy efficiency studies

This paper examines hydrogen leakage and efficiency across the supply chain for liquid, gaseous, and mixed hydrogen systems. These factors are crucial for assessing hydrogen's role in mitigating emissions and facilitating a clean energy transition. Drawing on a comprehensive review of existing literature and model-based analysis, the study compiles leakage rates and efficiency metrics at each stage of the supply chain: production, storage, transmission, distribution, and end-use. These data inform system scenarios that estimate the impact of leakage on overall performance and climate benefits. The analysis also identifies persistent data gaps, particularly for liquid and mixed system configurations, and outlines priorities for future research. A comparison of hydrogen system types shows that gaseous pathways generally achieve the highest efficiencies (28 %–39 %) and the lowest leakage rates (∼4.5 %) across the supply chain. Liquid hydrogen systems, while favorable for long-distance and high-volume transport due to their higher energy density, exhibit lower efficiency (∼28 %) and a greater leakage potential (∼12 %). Mixed systems, which combine gaseous and liquid elements (e.g., pipeline transmission followed by liquefaction and truck distribution), show compounded energy losses and moderate-to-high leakage rates (6.8 %–9.4 %), highlighting trade-offs associated with added system complexity. The study highlights opportunities for technological advancements, including optimizing liquefaction, enhancing insulation for storage and transportation, and refining refueling equipment. These improvements are crucial for maximizing the climate benefits of hydrogen. The results offer actionable insights for researchers, industry, and policymakers working to develop low-leakage, high-efficiency hydrogen infrastructure.

08 HYDROGEN↗

ClusterSculptor: Software for Expert-Steered Classification of Single Particle Mass Spectra

To take full advantage of the vast amount of highly detailed data acquired by single particle mass spectrometers requires that the data be organized according to some rules that have the potential to be insightful. Most commonly statistical tools are used to cluster the individual particle mass spectra on the basis of their similarity. Cluster analysis is a powerful strategy for the exploration of high-dimensional data in the absence of a-priori hypotheses or data classification models, and the results of cluster analysis can then be used to form such models. More often than not, when examining the data clustering results we find that many clusters contain particles of different types and that many particles of one type end up in a number of separate clusters. Our experience with cluster analysis shows that we have a vast amount of non-compiled knowledge and intuition that should be brought to bear in this effort. We will present new software we call ClusterSculptor that provides comprehensive and intuitive framework to aid scientists in data classification. ClusterSculptor uses k-means as the overall clustering engine, but allows tuning its parameters interactively, based on a non-distorted compact visual presentation of the inherent characteristics of the data in high-dimensional space. ClusterSculptor provides all the tools necessary for a high-dimensional activity we call cluster sculpting. ClusterSculptor is designed to be coupled to SpectraMiner, our data mining and visualization software package. The data are first visualized with SpectraMiner and identified problems are exported to ClusterSculptor, where the user steers the reclassification and recombination of clusters of tens of thousands particle mass spectra in real-time. The resulting sculpted clusters can be then imported back into SpectraMiner. Here we will greatly improved single particle chemical speciation in an example of application of this new tool to a number of particle types of atmospheric importance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Literature Survey and a Universal Evaporation Correlation for Plate type Heat Exchangers

Plate heat exchangers are widely used in the industry. Being compact in nature, they are good candidates to be used as evaporators with reduced charge. Here, a review of the existing evaporation heat transfer coefficient data for plate heat exchangers has been carried out. The literature survey also includes compilation of available Nusselt number correlations. In this work, an attempt has been made to develop a universal Nusselt number correlation that can be used to predict the heat transfer coefficient during evaporation of several key refrigerants using various plate geometries. The predicted values of Nusselt number using proposed correlation were found to be in good agreement with the experimental data of ammonia (R-717), R-134a, R-410A and few relatively new refrigerants. The proposed correlation is valid for 313 < Re eq < 12,700, 0.000136 < Bo eq < 0.0019 and is shown to predict the actual data within ±30% error. The predicted heat transfer coefficient was also found to be in good agreement with results from the major plate exchanger manufacturers.

42 ENGINEERING↗

Equilibrium vapor pressure properties for absorbent and adsorbent materials

Sorption devices are important tools for the efficient utilization of fuels and waste heat. Amid a tremendous diversity of cycles and applications, all sorption systems have an equilibrium vapor pressure that depends on the sorbent temperature and composition. The vapor pressure properties of working fluids are reported in the literature in a variety of ways, which impedes wide-ranging cross comparisons or screening studies for novel applications. This work compiles equilibrium vapor pressure properties for 123 liquid absorbents with 31 absorbates and 139 solid adsorbents with 16 adsorbates. The adsorption pairs are represented with six functional forms. Additionally, most of the absorption pairs are represented with 10 functional forms, plus several that are represented with custom empirical equations. Because the functional forms used in the literature vary widely, in this work each functional form was generalized. This paper is designed to facilitate comparisons of working fluid properties for screening studies, provide a quick reference to existing research, and present a framework for standardizing the reportage of vapor pressure equilibrium data for existing and future working pairs.

36 MATERIALS SCIENCE↗

Phase II Pilot Study of Bevacizumab in Combination with Temozolomide and Regional Radiation Therapy for Up-Front Treatment of Patients With Newly Diagnosed Glioblastoma Multiforme: Interim Analysis of Safety and Tolerability

Purpose: To assess interim safety and tolerability of a 10-patient, Phase II pilot study using bevacizumab (BV) in combination with temozolomide (TMZ) and regional radiation therapy (RT) in the up-front treatment of patients with newly diagnosed glioblastoma. Methods and Materials: All patients received standard external beam regional RT of 60.0 Gy in 30 fractions started within 3 to 5 weeks after surgery. Concurrently TMZ was given daily at 75 mg/m{sup 2} for 42 days during RT, and BV was given every 2 weeks at 10 mg/kg starting with the first day of RT/TMZ. After a 2-week interval upon completion of RT, the post-RT phase commenced with resumption of TMZ at 150 to 200 mg/m{sup 2} for 5 days every 4 weeks and continuation of BV every 2 weeks. Results: For these 10 patients, toxicities were compiled until study discontinuation or up to {approx}40 weeks from initial study treatment for those remaining on-study. In terms of serious immediate or delayed neurotoxicity, 1 patient developed presumed radiation-induced optic neuropathy. Among the toxicities that could be potentially treatment related, relatively high incidences of fatigue, myelotoxicity, wound breakdown, and deep venous thrombosis/pulmonary embolism were observed. Conclusion: The observed toxicities were acceptable to continue enrollment toward the overall target group of 70 patients. Preliminary efficacy analysis shows encouraging mean progression-free survival. At this time data are not sufficient to encourage routine off-label use of BV combined with TMZ/RT in the setting of newly diagnosed glioblastoma without longer follow-up, enrollment of additional patients, and thorough efficacy assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Patterns of Practice in Palliative Radiotherapy for Painful Bone Metastases: Evidence-Based Practice?

Purpose: Multiple randomized controlled trials have demonstrated the equivalence of multifraction and single-fraction (SF) radiotherapy for the palliation of painful bone metastases (BM). However, according to previous surveys, SF schedules remain underused. The objectives of this study were to determine the current patterns of practice internationally and to investigate the factors influencing this practice. Methods and Materials: The members of three global radiation oncology professional organizations (American Society for Radiology Oncology [ASTRO], Canadian Association of Radiation Oncology [CARO], Royal Australian and New Zealand College of Radiologists) completed an Internet-based survey. The respondents described what radiotherapy dose fractionation they would recommend for 5 hypothetical cases describing patients with single or multiple painful BMs from breast, lung, or prostate cancer. Radiation oncologists rated the importance of patient, tumor, institution, and treatment factors, and descriptive statistics were compiled. The chi-square test was used for categorical variables and the Student t test for continuous variables. Logistic regression analysis identified predictors of the use of SF radiotherapy. Results: A total of 962 respondents, three-quarters ASTRO members, described 101 different dose schedules in common use (range, 3 Gy/1 fraction to 60 Gy/20 fractions). The median dose overall was 30 Gy/10 fractions. SF schedules were used the least often by ASTRO members practicing in the United States and most often by CARO members. Case, membership affiliation, country of training, location of practice, and practice type were independently predictive of the use of SF. The principal factors considered when prescribing were prognosis, risk of spinal cord compression, and performance status. Conclusion: Despite abundant evidence, most radiation oncologists continue to prescribe multifraction schedules for patients who fit the eligibility criteria of previous randomized controlled trials. Our results have confirmed a delay in the incorporation of evidence into practice for palliative radiotherapy for painful bone metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Dose Constraint to Reduce Xerostomia in Head-and-Neck Cancer Patients Treated With Intensity-Modulated Radiotherapy

Purpose: To investigate the predictors of incidence and duration of xerostomia (XT) based on parotid glands (PG), submandibular glands (SMG), and both glands taken as a whole organ (TG) in head-and-neck cancer patients treated with intensity-modulated radiotherapy. Methods and Materials: A prospective study was initiated in May 2003. Sixty-three head-and-neck patients (44 with nasopharynx cancer) were included in the analysis. Using the dose-volume histogram the PG, SMG, and TG mean doses were calculated. Unstimulated and stimulated salivary flow were measured and XT-related questionnaires were compiled before and at 3, 6, 12, 18, and 24 months after radiotherapy. Salivary gland toxicity was evaluated using the Radiation Therapy Oncology Group scale, and Grade >=3 toxicity was used as the endpoint. The XT incidence was investigated according to descriptive statistics and univariate and multivariate analysis. The Bonferroni method was used for multiple comparison adjustment. Results: After a reduced flow at 3 months after radiotherapy, recovery of salivary flow was observed over time. Primary site and salivary gland mean doses and volumes were identified in univariate analysis as prognostic factors. Multivariate analysis confirmed that TG mean dose (p = 0.00066) and pretreatment stimulated salivary flow (p = 0.00420) are independent factors for predicting XT. Conclusion: The TG mean dose correlates with XT as assessed by Radiation Therapy Oncology Group criteria, salivary output, and XT-related questionnaires. Our results suggest that TG mean dose is a candidate dose constraint for reducing XT, requiring considerably more validation in non-nasopharyngeal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Radiobiological Analysis of Multicenter Data for Postoperative Keloid Radiotherapy

Purpose: To identify factors significantly affecting recurrence rates after postoperative external beam radiotherapy (XRT) of keloids, and to delineate any radiation dose response and effects of radiation dose per fraction. Methods and Materials: A comprehensive literature review was performed to compile a database of 2,515 resected keloids (36.9% earlobe). Postoperative XRT was 45- to 100-kV X-rays in 27.0% or 120- to 250-kV X-rays in 11.1%, Co-60 in 1.9%, Sr-90 in 4.7%, 1.5- to 9-MeV electrons in 26.5%, and no XRT in 28.8%. In the 1,791 irradiated patients, the median radiation parameters were as follows: total dose, 15 Gy (range, 6-30 Gy); dose per fraction, 5.0 Gy (range, 2-15 Gy); fractions, 3 (range, 1-10); and time, 7 days (range, 0-33 days). Results: Multivariate stepwise logistic regression correlated decreased keloid recurrence with earlobe location (p = 1.98E-10; odds ratio, 0.34), biologically effective dose (p = 1.01E-27), and treatment with electron beam or Co-60 vs. other techniques (p = 0.0014; odds ratio, 0.72). Different radiobiological models calculated values of {alpha}/{beta} = 1.12 to 2.86 (mean, 2.08) and time (repopulation) correction factors for biologically effective dose from 0.98 to 2.13 Gy per day (mean, 1.34) starting 10 days after surgery. Different models (with {alpha}/{beta} = 2.08) predicted that doses needed for 90% and 95% control with 3 fractions of postoperative electron beam were 16.0 to 16.2 Gy and 18.3 to 19.2 Gy, respectively, in less than 10 days for earlobe keloids and 21.5 to 22.2 Gy and 23.4 to 24.8 Gy, respectively, in less than 10 days for other sites. Conclusions: Postoperative keloid radiotherapy requires moderately high doses and optimal technique to be effective. The relatively low {alpha}/{beta} ratio indicates that radiotherapy with a limited number of fractions and high doses per fraction is the best strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Matched Survival Analysis in Patients With Locoregionally Advanced Resectable Oropharyngeal Carcinoma: Platinum-Based Induction and Concurrent Chemoradiotherapy Versus Primary Surgical Resection

Purpose: The outcome of a prospective case series of 47 patients with newly diagnosed resectable locoregionally advanced oropharyngeal squamous cell carcinoma treated with platinum-based induction-concurrent chemoradiotherapy (IC/CCRT) was compared with the outcome of 47 matched historical control patients treated with surgery and postoperative RT. Methods and Materials: A total of 47 control patients with locoregionally advanced oropharyngeal squamous cell carcinoma were identified from review of a prospectively compiled comprehensive computerized head-and-neck cancer database and were matched with a prospective case series of patients undergoing IC/CCRT by disease stage, nodal status, gender, and age ({+-}5 years). The IC/CCRT regimen consisted of one cycle of induction chemotherapy followed by conventionally fractionated RT to a total dose of 66-70 Gy concomitantly with two cycles of chemotherapy. Each cycle of chemotherapy consisted of cisplatinum, 100 mg/m{sup 2}, and a continuous infusion of 5-fluorouracil, 1,000 mg/m{sup 2}/d for 5 days. The survival analysis was performed using Kaplan-Meier estimates. Matched-pair survival was compared using the Cox proportional hazards model. Results: No significant difference was found in the overall survival or progression-free survival rates between the two groups. The matched analysis of survival did not show a statistically significant greater hazard ratio for overall death (hazard ratio, 1.35; 95% confidence interval, 0.65-2.80; p = .415) or progression (hazard ratio, 1.44; 95% confidence interval, 0.72-2.87; p = .301) for patients undergoing IC/CCRT. Conclusion: Although the sample size was small and not randomized, this matched-pair comparison between a prospective case series and a historical cohort treated at the same institution showed that the efficacy of IC/CCRT with salvage surgery is as good as primary surgical resection and postoperative RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anal Cancer: An Examination of Radiotherapy Strategies

The Radiation Therapy Oncology Group 9811, ACCORD-03, and ACT II Phase III trials in anal cancer showed no benefit for cisplatin-based induction and maintenance chemotherapy, or radiation dose-escalation >59 Gy. This review examines the efficacy and toxicity of chemoradiation (CRT) in anal cancer, and discusses potential alternative radiotherapy strategies. The evidence for the review was compiled from randomized and nonrandomized trials of radiation therapy and CRT. A total of 103 retrospective/observational studies, 4 Phase I/II studies, 16 Phase II prospective studies, 2 randomized Phase II studies, and 6 Phase III trials of radiotherapy or chemoradiation were identified. There are no meta-analyses based on individual patient data. A 'one-size-fits-all' approach for all stages of anal cancer is inappropriate. Early T1 tumors are probably currently overtreated, whereas T3/T4 lesions might merit escalation of treatment. Intensity-modulated radiotherapy or the integration of biological therapy may play a role in future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ExacTrac Snap Verification: A New Tool for Ensuring Quality Control for Lung Stereotactic Body Radiation Therapy

Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SV before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contemporary Trends in Radiation Oncology Resident Research

Purpose: To test the hypothesis that recent resident research productivity might be different than a decade ago, and to provide contemporary information about resident scholarly activity. Methods and Materials: We compiled a list of radiation oncology residents from the 2 most recent graduating classes (June 2014 and 2015) using the Association of Residents in Radiation Oncology annual directories. We queried the PubMed database for each resident's first-authored publications from postgraduate years (PGY) 2 through 5, plus a 3-month period after residency completion. We abstracted corresponding historical data for 2002 to 2007 from the benchmark publication by Morgan and colleagues (Int J Radiat Oncol Biol Phys 2009;74:1567-1572). We tested the null hypothesis that these 2 samples had the same distribution for number of publications using the Wilcoxon rank-sum test. We explored the association of demographic factors and publication number using multivariable zero-inflated Poisson regression. Results: There were 334 residents publishing 659 eligible first-author publications during residency (range 0-17; interquartile range 0-3; mean 2.0; median 1). The contemporary and historical distributions were significantly different (P<.001); contemporary publication rates were higher. Publications accrued late in residency (27% in PGY-4, 59% in PGY-5), and most were original research (75%). In the historical cohort, half of all articles were published in 3 journals; in contrast, the top half of contemporary publications were spread over 10 journals—most commonly International Journal of Radiation Oncology • Biology • Physics (17%), Practical Radiation Oncology (7%), and Radiation Oncology (4%). Male gender, non-PhD status, and larger residency size were associated with higher number of publications in the multivariable analysis. Conclusion: We observed an increase in first-author publications during training compared with historical data from the mid-2000s. These contemporary figures may be useful to medical students considering radiation oncology, current residents, training programs, and prospective employers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Quality and Safety Competency Curriculum for Radiation Oncology Residency: An International Delphi Study

Purpose: To develop an entry-to-practice quality and safety competency profile for radiation oncology residency. Methods and Materials: A comprehensive list of potential quality and safety competency items was generated from public and professional resources and interprofessional focus groups. Redundant or out-of-scope items were eliminated through investigator consensus. Remaining items were subjected to an international 2-round modified Delphi process involving experts in radiation oncology, radiation therapy, and medical physics. During Round 1, each item was scored independently on a 9-point Likert scale indicating appropriateness for inclusion in the competency profile. Items indistinctly ranked for inclusion or exclusion were re-evaluated through web conference discussion and reranked in Round 2. Results: An initial 1211 items were compiled from 32 international sources and distilled to 105 unique potential quality and safety competency items. Fifteen of the 50 invited experts participated in round 1: 10 radiation oncologists, 4 radiation therapists, and 1 medical physicist from 13 centers in 5 countries. Round 1 rankings resulted in 80 items included, 1 item excluded, and 24 items indeterminate. Two areas emerged more prominently within the latter group: change management and human factors. Web conference with 5 participants resulted in 9 of these 24 items edited for content or clarity. In Round 2, 12 participants rescored all indeterminate items resulting in 10 items ranked for inclusion. The final 90 enabling competency items were organized into thematic groups consisting of 18 key competencies under headings adapted from Deming's System of Profound Knowledge. Conclusions: This quality and safety competency profile may inform minimum training standards for radiation oncology residency programs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Financial Relationships With Industry of Editorial Board Members of the Three Journals of the American Society for Radiation Oncology

Purpose: To quantitate financial conflicts of interest (FCOIs) among radiation oncology peer-reviewers, specifically editorial board members of the 3 American Society for Radiation Oncology journals. Methods and Materials: The public Centers for Medicare and Medicaid Services Open Payments database delineates payments in 3 categories (general payments, research funding, and company ownership). After excluding non-US and non-MDs, names of board members were searched. Values of each FCOI were extracted for 2013 to 2015 and compiled. Results: Of 85 board members, 65 (76%) received any form of payment during the overall period. The majority of delivered payments were general payments: 59 (69%) received at least 1 general payment during these 3 years. In each year, 9 board members (11%) received research funding, and 3 board members (4%) reported company ownership. Over the studied period, all board members received a sum total of $5,387,985; this was composed of $665,801 (12%) in general payments, $3,758,968 (70%) in research funding, and $963,216 (18%) in company ownership. The mean general payment and research funding amounts (all members) were $2,621 and $14,741, respectively. Median (interquartile range) general payments and research funding only in board members receiving payments were $419 ($91-$5072) and $56,250 ($13,345-$200,000), respectively. When assessing general payments according to amount, the vast majority of editorial board members received lower-quantity or no such payments, along with a smaller proportion that received higher-volume payments. The most frequent sources of general payments were Varian, Elekta, and Bristol-Myers Squibb. Merck and Varian were the most frequent funding sources for research payments. Conclusions: In this population, the majority of FCOIs were general payments, but research funding comprised the highest monetary sums. Large-volume FCOIs do not apply to the vast majority of editorial board members, implying that the maintained integrity of academic peer-review is likely not influenced to a large extent by FCOIs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A human antibody epitope map of Pfs230D1 derived from analysis of individuals vaccinated with a malaria transmission-blocking vaccine

Pfs230 domain 1 (Pfs230D1) is an advanced malaria transmission-blocking vaccine antigen demonstrating high functional activity in clinical trials. However, the structural and functional correlates of transmission-blocking activity are not defined. Here, we characterized a panel of human monoclonal antibodies (hmAbs) elicited in vaccinees immunized with Pfs230D1. These hmAbs exhibited diverse transmission-reducing activity, yet all bound to Pfs230D1 with nanomolar affinity. We compiled epitope-binning data for seventeen hmAbs and structures of nine hmAbs complexes to construct a high-resolution epitope map and revealed that potent transmission-reducing hmAbs bound to one face of Pfs230D1, while non-potent hmAbs bound to the opposing side. The structure of Pfs230D1D2 revealed that non-potent transmission-reducing epitopes were occluded by the second domain. The hmAb epitope map delineated binary hmAb combinations that synergized for extremely high-potency, transmission-reducing activity. Finally, this work provides a high-resolution guide for structure-based design of enhanced immunogens and informs diagnostics that measure the transmission-reducing response.

60 APPLIED LIFE SCIENCES↗