Small burst data (SBD) satellite communications
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Primary Goal: Send important sensor data from payload to SV following an event trigger as quickly as possible with high data integrity.
In this paper, we compare three approaches used for continuous transfer of real-time synchrophasor data: IEEE C37.118.2-2011, IEC TR 61850-90-5 and a new protocol being developed under the Department of Energy (DOE) project DOE-OE-859 called the Streaming Telemetry Transport Protocol (STTP). STTP is currently being advanced as a potential third standard protocol via the IEEE Power Engineering Society STTP P10 Work Group (P2664). Each of these three synchrophasor protocols is described in detail in this paper along with the basis for their operating characteristics using Internet Protocol (IP) transport. The dominant protocol for the exchange of synchrophasor data is IEEE C37.118, both in the U.S. and internationally. The most recent IEEE C37.118 standard is broken into two parts where IEEE C37.118.1-2011 (Part 1) defines the normative synchrophasor measurement requirements and IEEE C37.118.2-2011 (Part 2) defines the protocol’s data transmission format. Both the IEC TR 61850-90-5 and the emergent STTP specifications only address synchrophasor data transmission; therefore, this paper focuses on comparing the data transmission protocol elements of these standards. The primary dimensions of comparison of these three protocols explored in this paper are: structure, efficiency, susceptibility to data loss, scalability, security, and other operability functionality. Additionally, though not specifically relevant to synchrophasor data telemetry, the three protocols are evaluated with respect to flexibility for transporting non-synchrophasor precise-time data streams.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Various wireless technologies were field-tested in a six-story laboratory building to identify wireless technologies that can scale for future DR applications through very low node density power consumption, and unit cost. Data analysis included analysis of the signal-to-noise ratio (SNR), packet loss, and link quality at varying power levels and node densities. The narrowband technologies performed well, penetrating the floors of the building with little loss and exhibiting better range than the wideband technology. 900 MHz provided full coverage at 1 watt and substantially complete coverage at 500 mW at the test site. 900 MHz was able to provide full coverage at 100 mW with only one additional relay transmitter, and was the highest-performing technology in the study. 2.4 GHz could not provide full coverage with only a single transmitter at the highest power level tested (63 mW). However, substantially complete coverage was provided at 2.4 GHz at 63 mW with the addition of one repeater node.
For the Domestic Nuclear Detection Office’s Rail Test Center (i.e., DNDO’s RTC), port operation knowledge with flexible collection tools and technique are essential in both technology testing design and implementation intended for live operational settings. Increased contextual data, flexibility in procedures, and rapid availability of information are keys to addressing the challenges of optimization, validation, and analysis within live operational setting data collection. These concepts need to be integrated into technology testing designs, data collection, validation, and analysis processes. A modified data collection technique with a two phased live operation test method is proposed.
Recent trends in high-performance computing point towards increasingly large machines with millions of processing, storage, and networking elements. Unfortunately, the reliability of these machines is inversely proportional to their size, resulting in a system-wide mean-time-between-failures (MTBF) ranging from a few days to a few hours. As such, for long-running applications, the ability to efficiently recover from frequent failures is essential. Traditional forms of fault tolerance, such as checkpoint/restart, suffer from performance issues related to limited I/O and memory bandwidth. In this paper, we present a fault-tolerance mechanism that reduces the cost of failure recovery by maintaining shadow data structures and performing redundant remote memory accesses. We present results from a computational chemistry application running at scale to show that our techniques provide applications with a high degree of fault tolerance and low (2%--4%) overhead for 2048 processors.
No abstract prepared.
Plug loads represent 30percent of total electricity use in residential buildings. Significant energy savings would result from an accurate understanding of which miscellaneous electric devices are using energy, at what time, and in what quantity. Commercially available plug load monitoring and control solutions replace or limit the attached device's native controls - forcing the user to adapt to a separate set of controls associated with the monitoring and control hardware. A better solution is integration of these capabilities at the power supply level. In this paper, we demonstrate a method achieving this integration. Our solution allows unobtrusive power monitoring and control while retaining native device control features. Further, our prototype enables intelligent behaviors by allowing devices to respond to the state of one another automatically. The CPS enables energy savings while demonstrating an added level of functionality to the user. If CPS technology became widespread in devices, a combination of automated and human interactive solutions would enable high levels of energy savings in buildings.
This assessment summary describes how the industrial Technologies Program helped Verizon to find ways to improve the efficiency of its data center by performing a Save Energy Now energy assessment.
Overview fact sheet about the Electric Power Research Institute (EPRI) and Schneider Electric Integrated Network Testbed for Energy Grid Research and Technology Experimentation (INTEGRATE) project at the Energy Systems Integration Facility. INTEGRATE is part of the U.S. Department of Energy's Grid Modernization Initiative.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Protocol analytics for enabling forensics of industrial control systems.