Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transmittal of the Calculation Package that Supports the Analysis of Performance of the Environmental Management Waste Management Facility Oak Ridge, Tennessee (Based 5-Cell Design Issued 8/14/09)

This document presents the results of an assessment of the performance of a build-out of the Environmental Management Waste Management Facility (EMWMF). The EMWMF configuration that was assessed includes the as-constructed Cells 1 through 4, with a groundwater underdrain that was installed beneath Cell 3 during the winter of 2003-2004, and Cell 5, whose proposed design is an Addendum to Remedial Design Report for the Disposal of Oak Ridge Reservation Comprehensive Environmental Response, Compensation, and Liability Act of 1980 Waste, Oak Ridge, Tennessee, DOE/OR/01-1873&D2/A5/R1. The total capacity of the EMWMF with 5 cells is about 1.7 million cubic yards. This assessment was conducted to determine the conditions under which the approved Waste Acceptance Criteria (WAC) for the EMWMF found in the Attainment Plan for Risk/Toxicity-Based Waste Acceptance Criteria at the Oak Ridge Reservation, Oak Ridge, Tennessee [U.S. Department of Energy (DOE) 2001a], as revised for constituents added up to October 2008, would remain protective of public health and safety for a five-cell disposal facility. For consistency, the methods of analyses and the exposure scenario used to predict the performance of a five-cell disposal facility were identical to those used in the Remedial Investigation and Feasibility Study (RI/FS) and its addendum (DOE 1998a, DOE 1998b) to develop the approved WAC. To take advantage of new information and design changes departing from the conceptual design, the modeling domain and model calibration were upaded from those used in the RI/FS and its addendum. It should be noted that this analysis is not intended to justify or propose a change in the approved WAC.

54 ENVIRONMENTAL SCIENCES↗

High Efficiency Adsorption Chillers: High Efficiency Adsorption Cooling Using Metal Organic Heat Carriers

BEETIT Project: PNNL is incorporating significant improvements in materials that adsorb liquids or gases to design more efficient adsorption chillers. An adsorption chiller is a type of air conditioner that is powered by heat, solar or waste heat, or combustion of natural gas. Unlike typical chillers, this type has few moving parts and uses almost no electricity to operate. PNNL is designing adsorbent materials at the molecular level with at least 3 times higher refrigerant capacity and up to 20 times faster kinetics than adsorbents used in current chillers. By using the new adsorbent, PNNL is able to create a chiller that is significantly smaller, has twice the energy efficiency, and lower costs for materials and assembly time compared to conventional adsorption chillers.

ARPA-E↗

Optimal Sizing of Energy Storage and Photovoltaic Power Systems for Demand Charge Mitigation (Poster)

Commercial facility utility bills are often a strong function of demand charges -- a fee proportional to peak power demand rather than total energy consumed. In some instances, demand charges can constitute more than 50% of a commercial customer's monthly electricity cost. While installation of behind-the-meter solar power generation decreases energy costs, its variability makes it likely to leave the peak load -- and thereby demand charges -- unaffected. This then makes demand charges an even larger fraction of remaining electricity costs. Adding controllable behind-the-meter energy storage can more predictably affect building peak demand, thus reducing electricity costs. Due to the high cost of energy storage technology, the size and operation of an energy storage system providing demand charge management (DCM) service must be optimized to yield a positive return on investment (ROI). The peak demand reduction achievable with an energy storage system depends heavily on a facility's load profile, so the optimal configuration will be specific to both the customer and the amount of installed solar power capacity. We explore the sensitivity of DCM value to the power and energy levels of installed solar power and energy storage systems. An optimal peak load reduction control algorithm for energy storage systems will be introduced and applied to historic solar power data and meter load data from multiple facilities for a broad range of energy storage system configurations. For each scenario, the peak load reduction and electricity cost savings will be computed. From this, we will identify a favorable energy storage system configuration that maximizes ROI.

14 SOLAR ENERGY↗

Composite Materials for Hazard Mitigation of Reactive Metal Hydrides.

In an attempt to mitigate the hazards associated with storing large quantities of reactive metal hydrides, polymer composite materials were synthesized and tested under simulated usage and accident conditions. The composites were made by polymerizing vinyl monomers using free-radical polymerization chemistry, in the presence of the metal hydride. Composites with vinyl-containing siloxane oligomers were also polymerized with and without added styrene and divinyl benzene. Hydrogen capacity measurements revealed that addition of the polymer to the metal hydride reduced the inherent hydrogen storage capacity of the material. The composites were found to be initially effective at reducing the amount of heat released during oxidation. However, upon cycling the composites, the mitigating behavior was lost. While the polymer composites we investigated have mitigating potential and are physically robust, they undergo a chemical change upon cycling that makes them subsequently ineffective at mitigating heat release upon oxidation of the metal hydride. Acknowledgements The authors would like to thank the following people who participated in this project: Ned Stetson (U.S. Department of Energy) for sponsorship and support of the project. Ken Stewart (Sandia) for building the flow-through calorimeter and cycling test stations. Isidro Ruvalcaba, Jr. (Sandia) for qualitative experiments on the interaction of sodium alanate with water. Terry Johnson (Sandia) for sharing his expertise and knowledge of metal hydrides, and sodium alanate in particular. Marcina Moreno (Sandia) for programmatic assistance. John Khalil (United Technologies Research Corp) for insight into the hazards of reactive metal hydrides and real-world accident scenario experiments. Summary In an attempt to mitigate and/or manage hazards associated with storing bulk quantities of reactive metal hydrides, polymer composite materials (a mixture of a mitigating polymer and a metal hydride) were synthesized and tested under simulated usage and accident conditions. Mitigating the hazards associated with reactive metal hydrides during an accident while finding a way to keep the original capability of the active material intact during normal use has been the focus of this work. These composites were made by polymerizing vinyl monomers using free-radical polymerization chemistry, in the presence of the metal hydride, in this case a prepared sodium alanate (chosen as a representative reactive metal hydride). It was found that the polymerization of styrene and divinyl benzene could be initiated using AIBN in toluene at 70°C. The resulting composite materials can be either hard or brittle solids depending on the cross-linking density. Thermal decomposition of these styrene-based composite materials is lower than neat polystyrene indicating that the chemical nature of the polymer is affected by the formation of the composite. The char-forming nature of cross-linked polystyrene is low and therefore, not an ideal polymer for hazard mitigation. To obtain composite materials containing a polymer with higher char-forming potential, siloxane-based monomers were investigated. Four vinyl-containing siloxane oligomers were polymerized with and without added styrene and divinyl benzene. Like the styrene materials, these composite materials exhibited thermal decomposition behavior significantly different than the neat polymers. Specifically, the thermal decomposition temperature was shifted approximately 100 °C lower than the neat polymer signifying a major chemical change to the polymer network. Thermal analysis of the cycled samples was performed on the siloxane-based composite materials. It was found that after 30 cycles the siloxane-containing polymer composite material has similar TGA/DSC-MS traces as the virgin composite material indicating that the polymer is physically intact upon cycling. Hydrogen capacity measurements revealed that addition of the polymer to the metal hydride in the form of a composite material reduced the inherent hydrogen storage capacity of the material. This reduction in capacity was observed to be independent of the amount of charge/discharge cycles except for the composites containing siloxane, which showed less of an impact on hydrogen storage capacity as it was cycled further. While the reason for this is not clear, it may be due to a chemically stabilizing effect of the siloxane on the metal hydride. Flow-through calorimetry was used to characterize the mitigating effectiveness of the different composites relative to the neat (no polymer) material. The composites were found to be initially effective at reducing the amount of heat released during oxidation, and the best performing material was the siloxane-containing composite which reduced the heat release to less than 50% of the value of the neat material. However, upon cycling the composites, all mitigating behavior was lost. The combined results of the flow-through calorimetry, hydrogen capacity, and thermogravimetric analysis tests lead to the proposed conclusion that while the polymer composites have mitigating potential and are physically robust under cycling, they undergo a chemical change upon cycling that makes them ineffective at mitigating heat release upon oxidation of the metal hydride.

36 MATERIALS SCIENCE↗

Electrohydrodynamic Enabled Electrochemical Membrane Dehumidifier for Separate Sensible and Latent Cooling

In hot and humid parts of the world, air conditioning is a necessity for an adequate standard of living. Cooling and heating represent one-third of building energy consumption. When cooling humid air, a substantial amount of the cooling energy is absorbed by water vapor condensation. The dehumidification cooling load is referred to as the latent cooling load and the dry bulb cooling load is referred to as the sensible cooling load. In most residential applications, the total cooling load is processed by a vapor compression cycle. Processing the latent load separately would not only reduce energy consumption. It would also reduce the required refrigeration capacity. Refrigerants often have adverse ecological impacts, contributing to the greenhouse effect and depletion of the ozone layer. Reduction of the cooling capacity in a system could reduce the amount of refrigerant charge required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The TRANSCEND University Consortium: Theme 2 - Site Decommissioning, Deconstruction and Remediation - 20329

This paper will discuss the aims, objectives and progress to-date under Theme 2 of the TRANSCEND consortium project: Site decommissioning, deconstruction and remediation. Decommissioning nuclear sites involves waste retrieval, decontamination, deconstruction and, where necessary, containment and/or remediation of the remaining structure and surrounding land. Critical to management of these processes is limiting radiation exposure for the workforce, restricting the spread of radionuclides in groundwater, surface water and airborne particulates, and minimising the volume of contaminated waste for disposal. The aim of Theme 2 research is to develop new technologies for monitoring, remediation and containment that serve to minimise the volume of radioactively contaminated waste for disposal, for application prior to, during and after retrieval, deconstruction and decontamination operations. Prior research, conducted under the previous DISTINCTIVE project, demonstrated that colloidal silica grout can penetrate low permeability materials (including cement) for hydraulic barrier formation, and improved sorption capacity. The silica grout can be injected at surface using extremely small (potentially gravity-driven) fluid pressures, without the need for borehole drilling. Current work is investigating the erodibility of silica-grouted soils for inhibition of airborne and water-borne particulates as well as enhancing the grout's sorption capacity by addition of other materials to provide a chemical, as well as hydraulic, barrier to subsurface migration. EK remediation uses low voltage DC current to control migration of contaminants in porous media as well as to remove or degrade them. Researchers in the consortium have already demonstrated that low-energy ex-situ EK techniques can be used to provide remediation and volume minimisation for AWE legacy wastes in the UK. Under the current project researchers are building EK test cells containing simulated site materials at laboratory and intermediate(m)-scales to: remove, focus or degrade contaminants (remediation or waste minimisation); and direct subsurface water, chemical and colloid flow (fencing/containment or forced migration). This lab-based research is being informed by numerical models of EK processes that can subsequently be used to design full-scale on-site applications by nuclear site holders. Research under theme 2 of TRANSCEND will ultimately combine novel non-invasive detection technologies with EK techniques and colloidal silica grout barriers, to optimise the containment of radionuclide contamination in soils. Thus, allowing us to detect in-situ contamination, mobilise it to a selected location and grout it in-situ, prior to the initiation of decommissioning and deconstruction operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward Accelerating Discovery via Physics-Driven and Interactive Multifidelity Bayesian Optimization

Both computational and experimental material discovery bring forth the challenge of exploring multidimensional and often nondifferentiable parameter spaces, such as phase diagrams of Hamiltonians with multiple interactions, composition spaces of combinatorial libraries, processing spaces, and molecular embedding spaces. Often these systems are expensive or time consuming to evaluate a single instance, and hence classical approaches based on exhaustive grid or random search are too data intensive. This resulted in strong interest toward active learning methods such as Bayesian optimization (BO) where the adaptive exploration occurs based on human learning (discovery) objective. However, classical BO is based on a predefined optimization target, and policies balancing exploration and exploitation are purely data driven. In practical settings, the domain expert can pose prior knowledge of the system in the form of partially known physics laws and exploration policies often vary during the experiment. Here, we propose an interactive workflow building on multifidelity BO (MFBO), starting with classical (data-driven) MFBO, then expand to a proposed structured (physics-driven) structured MFBO (sMFBO), and finally extend it to allow human-in-the-loop interactive interactive MFBO (iMFBO) workflows for adaptive and domain expert aligned exploration. These approaches are demonstrated over highly nonsmooth multifidelity simulation data generated from an Ising model, considering spin–spin interaction as parameter space, lattice sizes as fidelity spaces, and the objective as maximizing heat capacity. Detailed analysis and comparison show the impact of physics knowledge injection and real-time human decisions for improved exploration with increased alignment to ground truth. Here, the associated notebooks allow to reproduce the reported analyses and apply them to other systems.

97 MATHEMATICS AND COMPUTING↗

Northeast Clean Energy Application Center

From October 1, 2009 through September 30, 2013 (“contract period”), the Northeast Clean Energy Application Center (“NE-CEAC”) worked in New York and New England (Connecticut, Rhode Island, Vermont, Massachusetts, New Hampshire, and Maine) to create a more robust market for the deployment of clean energy technologies (CETs) including combined heat and power (CHP), district energy systems (DES), and waste heat recovery (WHR) systems through the provision of technical assistance, education and outreach, and strategic market analysis and support for decision-makers. CHP, DES, and WHR can help reduce greenhouse gas emissions, reduce electrical and thermal energy costs, and provide more reliable energy for users throughout the United States. The NE-CEAC’s efforts in the provision of technical assistance, education and outreach, and strategic market analysis and support for decision-makers helped advance the market for CETs in the Northeast thereby helping the region move towards the following outcomes: Reduction of greenhouse gas emissions and criteria pollutants; Improvements in energy efficiency resulting in lower costs of doing business; Productivity gains in industry and efficiency gains in buildings; Lower regional energy costs; Strengthened energy security; Enhanced consumer choice; Reduced price risks for end-users; and Economic development effects keeping more jobs and more income in our regional economy Over the contract period, NE-CEAC provided technical assistance to approximately 56 different potential end-users that were interested in CHP and other CETs for their facility or facilities. Of these 56 potential end-users, five new CHP projects totaling over 60 MW of install capacity became operational during the contract period. The NE-CEAC helped host numerous target market workshops, trainings, and webinars; and NE-CEAC staff delivered presentations at many other workshops and conferences. In total, over 60 different workshops, conferences, webinars, and presentation were hosted or delivered during the contract period. The NE-CEAC also produced publically available educational materials such as CHP project profiles. Finally, the NE-CEAC worked closely with the relevant state agencies involved with CHP development. In New York, the NE-CEAC played an important role in securing and maintaining funding for CHP incentive programs administered by the New York State Energy Research Development Authority. NE-CEAC was also involved in the NYC Mayor's Office DG Collaborative. The NECEAC was also named a strategic resource for the Connecticut Department of Energy and Environmental Protection’s innovative Microgrid Pilot Program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Document Management: A Focused Analysis on the Configuration Management Process at Y-12 National Security Complex

The configuration management process at Y-12 is a crucial process to ensure safe operations and compliance with Department of Energy (DOE) regulations and requirements. This process is evaluated utilizing systems-thinking methodology in order to understand the current operational flow, with the ultimate goal of building an easily understandable, representative model. This model offers insights on key areas of waste and provides a potential solution by modernizing rate limiting steps: a software implementation to update the traditional document management system and make it paperless. Stakeholders of the software implementation are identified in order to define characteristic requirements of an effective product and the anticipated benefit is evaluated. Ultimately, this project is an effort to increase the quality of life for all stakeholders, while improving the capacity, throughput, and effectiveness of a necessary process at Y-12.

42 ENGINEERING↗

The Status of LILW Complex Disposal Facility Construction in Korea-18511

This paper provides the status and experiences of Low and Intermediate-level radioactive Waste (LILW) disposal facility in Korea. The LILW disposal facility is being constructed in Gyeongju-si, Korea. It can dispose of 800,000 drums (hereafter, 'drums' means '200 liter drum equivalents' unless specified otherwise) of radioactive waste in a site of 2,060,000 m{sup 2}. The first stage of the LILW facility construction was completed in June 2014, and approved for use by Nuclear Safety and Security Commission (NSSC) in December 2014. The first stage of the LILW facility, which is a type of underground silo with disposal capacity of 35,200 m{sup 3} (100,000 drums), consists of a construction tunnel, an operation tunnel, an access shaft, and six silos, etc. Silo for final disposal is located 80∼130 m below sea level, 25 m in diameter and 50 m in height. The capacity of each silo is approximately 16,700 drums. The second stage of the LILW facility is under construction and will be completed by December 2020. The second stage of the LILW facility, which is a type of near-surface disposal with disposal capacity of 32,875 m{sup 3} (125,000 drums), consists of an underground gallery, three movable cranes and twenty vaults, etc. Vault for final disposal is located about 100 m above sea level, 20 m in width, 20 m length and 10.9 m in height. The capacity of each vault is approximately 6,250 drums. A second receipt and storage facility is to be completed by June 2021. This facility is under designing to prepare for further increasing radioactive waste receipt quantities. It has storage capacity of 10,000 drums (existing receipt and storage facility have storage capacity of 7,000 drums)and will be divided into several sections for pre-disposal work, storage, a passage to link the existing facility to the second receipt and storage facility and truck bay, etc. These components of the LILW disposal facilities are together called LILW complex disposal facility. It is the world's first LILW disposal facility with two different types of disposal facilities in one site. For efficient operation, these disposal facilities share a receipt and storage building, a waste water treatment system, a measurement and monitoring system, etc. Once the construction of the first two stages is completed, LILW disposal facilities will be incrementally expanded, and as the whole LILW disposal facilities are completed, all LILW in Korea will be disposed of these disposal facilities efficiently according to its radioactivity level and managed safely by KORAD. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Eddy current sensor for in-situ monitoring of swelling of Li-ion prismatic cells

In-situ monitoring an on-board rechargeable battery in hybrid cars can be used to ensure a long operating life of the battery and safe operation of the vehicle. Intercalations of ions in the electrode material during charge and discharge of a Lithium Ion battery cause periodic stress and strain of the electrode materials that can ultimately lead to fatigue resulting in capacity loss and potential battery failure. Currently this process is not monitored directly on the cells. This work is focused on development technologies that would quantify battery swelling and provide in-situ monitoring for onboard vehicle applications. Several rounds of tests have been performed to spatially characterize cell expansion of a 5 Ah cell with a nickel/manganese/cobalt-oxide cathode (Sanyo, Japan) used by Ford in their Fusion HEV battery pack. A collaborative team of researchers from GE and the University of Michigan has characterized the free expansion of these cells to be in the range of 100×125 microns (1% of total cell thickness) at the center point of the cell. GE proposed to use a thin eddy current (EC) coil to monitor these expansions on the cells while inside the package. The photolithography manufacturing process previously developed for EC arrays for detecting cracks in aircraft engine components was used to build test coils for gap monitoring. These sensors are thin enough to be placed safely between neighboring cells and capable of monitoring small variations in the gap between the cells. Preliminary investigations showed that these coils can be less than 100 micron thick and have sufficient sensitivity in a range from 0 to 2 mm. Laboratory tests revealed good correlation between EC and optical gap measurements in the desired range. Further technology development could lead to establishing a sensor network for a low cost solution for the in-situ monitoring of cell swelling during battery operation.

42 ENGINEERING↗

Carbonation reaction of recycled concrete aggregates (RCA): CO 2 mass consumption under various treatment conditions

Concrete is a key building material around the world due to its excellent strength and durability. Recycling demolished concrete for new construction materials may play a significant role in sustainable development. Producing recycled concrete aggregates (RCA) from waste concrete is one approach for such an initiative. However, using RCA may pose challenges, such as reduced density, lower elastic modulus and strength, and increased water absorption. Recently, the carbonation of RCA has emerged as a method to address those concerns. This study explores the carbon sequestration capacity of RCA through carbonation, examining various parametric conditions, including initial CO 2 pressure, relative humidity, temperature, and pre-treatment approach. Both lab-scale and large-scale carbonation tests were conducted. Additionally, a cost analysis and CO 2 footprint assessment were performed. The findings showed that applying higher initial CO 2 pressures (e.g., 40–60 psi) and optimal relative humidity (~55 %) could significantly enhance the carbonation efficiency of RCA. Elevating temperature also led to accelerated CO 2 consumption, being more effective on the lab scale. The economic analysis presented potential cost benefits when substituting natural aggregates with CO 2 -treated RCA. All in all, these results suggest that the carbonation of RCA may provide significant environmental benefits through carbon sequestration, promoting sustainable construction practices.

36 MATERIALS SCIENCE↗

Coal as Value-Added for Lithium Battery Anodes (Final Report)

Graphite is a basic material used for energy storage in lithium-ion (Li-ion) batteries. More than 70% of worldwide graphite production and nearly 50% of the annual graphite supply for the United States comes from China. Potential economic and national security concerns exist because Li-ion batteries are used not only for the fast-growing electrical vehicle market (15.6% compound annual growth rate [CAGR] from 2018 to 2028 in North America), but also for defense applications including unmanned aerial and ground vehicles. Development of an alternative formulation for Li-ion batteries is key. Building upon previous research confirming the ability of silicon alloys to improve the energy density of anodes, Semplastics developed a novel material based on our X-MAT® polymer-derived ceramic (PDC) technology. The X-MAT anode material is a composite of chemically tailored silicon oxycarbide (SiOC) and domestically sourced coal powder, designed to be a drop-in replacement for graphite within Li-ion battery anodes. Preliminary tests of this material showed more than twice the reversible capacity of graphite anodes (1,000 mAh/g vs. 372 mAh/g), with excellent stability and capacity retention, almost 100% coulombic efficiency, low voltage potential, and low thermal expansion. At full adoption in 2024, we expect the coal utilization to reach 27,300 tons. Through this project, Semplastics proposed to complete development and begin commercialization of this material. The objective was to determine the best formulation for technical performance and economic viability. At the end of the project, the X-MAT anode material is ready for implementation into existing battery manufacturing processes and can have a significant impact on the utilization of coal, with positive effects for the mining sector and the mitigation of carbon dioxide (CO 2 ) emissions.

01 COAL, LIGNITE, AND PEAT↗

Tracking the Sun III; The Installed Cost of Photovoltaics in the United States from 1998-2009

Installations of solar photovoltaic (PV) systems have been growing at a rapid pace in recent years. In 2009, approximately 7,500 megawatts (MW) of PV were installed globally, up from approximately 6,000 MW in 2008, consisting primarily of grid-connected applications. With 335 MW of grid-connected PV capacity added in 2009, the United States was the world's fourth largest PV market in 2009, behind Germany, Italy, and Japan. The market for PV in the United States is driven by national, state, and local government incentives, including up-front cash rebates, production-based incentives, requirements that electricity suppliers purchase a certain amount of solar energy, and federal and state tax benefits. These programs are, in part, motivated by the popular appeal of solar energy, and by the positive attributes of PV - modest environmental impacts, avoidance of fuel price risks, coincidence with peak electrical demand, and the possible deployment of PV at the point of use. Given the relatively high cost of PV, however, a key goal of these policies is to encourage cost reductions over time. Therefore, as policy incentives have become more significant and as PV deployment has accelerated, so too has the desire to track the installed cost of PV systems over time, by system characteristics, by system location, and by component. Despite the significant year-on-year growth, however, the share of global and U.S. electricity supply met with PV remains small, and annual PV additions are currently modest in the context of the overall electric system. To address this need, Lawrence Berkeley National Laboratory initiated a report series focused on describing trends in the installed cost of grid-connected PV systems in the United States. The present report, the third in the series, describes installed cost trends from 1998 through 2009, and provides preliminary cost data for systems installed in 2010. The analysis is based on project-level cost data from approximately 78,000 residential and non-residential PV systems in the U.S., all of which are installed at end-use customer facilities (herein referred to as 'customer-sited' systems). The combined capacity of systems in the data sample totals 874 MW, equal to 70% of all grid-connected PV capacity installed in the United States through 2009 and representing one of the most comprehensive sources of installed PV cost data for the U.S. The report also briefly compares recent PV installed costs in the United States to those in Germany and Japan. Finally, it should be noted that the analysis presented here focuses on descriptive trends in the underlying data, serving primarily to summarize the data in tabular and graphical form; later analysis may explore some of these trends with more-sophisticated statistical techniques. The report begins with a summary of the data collection methodology and resultant dataset (Section 2). The primary findings of the analysis are presented in Section 3, which describes trends in installed costs prior to receipt of any financial incentives: over time and by system size, component, state, system ownership type (customer-owned vs. third party-owned), host customer segment (residential vs. commercial vs. public-sector vs. non-profit), application (new construction vs. retrofit), and technology type (building-integrated vs. rack-mounted, crystalline silicon vs. thin-film, and tracking vs. fixed-axis). Section 4 presents additional findings related to trends in PV incentive levels over time and among states (focusing specifically on state and utility incentive programs as well as state and federal tax credits), and trends in the net installed cost paid by system owners after receipt of such incentives. Brief conclusions are offered in the final section, and several appendices provide additional details on the analysis methodology and additional tabular summaries of the data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Resource Assessment for Distributed Wind Energy: An Evaluation of Best-Practice Methods in the Continental US

Current wind resources within the United States (US) indicate a potential to profitably install nearly 1,400 gigawatts of distributed wind (DW) capacity. This amount is equivalent to over half of the United States’ current energy demand from electricity, making it enough to power millions of homes and businesses and replace countless fossil fuel-based generating plants. Despite the potential growth of DW in the US, deployments are presently hindered by a lack of confidence in resource estimation methods. One potential challenge is that smaller-scale turbines, with hub heights of 40 meters or less, are disproportionately impacted by obstacles such as buildings and vegetation. These obstacles may produce complex wake effects, best modeled with high-fidelity complex fluid dynamics (CFD) models that are too computationally expensive to use for routine siting and resource assessment. Thus, installers today make use of heuristics and simple equations to approximate the impact of obstacles while also leveraging long-term resource data from commercial or publicly available atmospheric models. This study evaluates these historical and commonly used methods alongside new lower-order obstacle models produced from CFD simulations and measurement-based bias correction. The preliminary results from this study show the importance of taking care in the choice and application of mesoscale atmospheric models and the significant value of bias correction using measurements from nearby meteorological towers. Detailed obstacle modeling provides only modest additional gains in performance and, in some cases, can add error, especially at sites where turbines have already been located to avoid obvious impact from upwind obstacles. These findings reinforce the importance of collecting in situ measurements and suggest that obstacle models may be better applied in practice to automated or computer-aided siting, rather than in economic wind resource assessments.

17 WIND ENERGY↗

Tiered Approach to Resilience Assessment

Regulatory agencies have long adopted a three-tier structure for risk assessment and risk management. We build on this structure to propose a tiered approach for resilience assessment that can be integrated in the existing regulatory processes. Comprehensive approaches to assessing resilience at appropriate and operational scales, reconciling analytical complexity as needed with stakeholder needs and resources available, and ultimately creating actionable recommendations to enhance resilience is still lacking. Our proposed structure consists of tiers by which analysts can scale a resilience assessment and associated management actions relative to the scope and urgency of the risk and the capacity of resource managers to improve system resilience. We use an application of water allocation decisions in the Platte River Basin, Nebraska, USA to illustrate this approach.

Sustainability, natural resources management, disa↗

Heteroatom-Modified and Compacted Zeolite-Templated Carbons for Gas Storage

Methane, the primary component of natural gas, is an energy-rich fuel by weight but exhibits lower energy density by volume than diesel and gasoline; efforts to increase its “volumetric” energy density have been focused on the design and synthesis of a porous scaffold that can bind the methane favorably. Novel approaches typically invoke the highly designable class of materials known as metal-organic frameworks (MOFs) owing to the relative difficulty of controlling carbon structure and composition precisely, without the use of a metal-based node. In this project, we instead explore the concept of carbon templating to achieve a porous scaffold with atomistically thin walls separated at a distance of ~1.2 nm, ideal for the formation of precisely two layers of methane per pore. This bottom-up templating approach permits the use of any small molecular precursor to build up the carbon scaffold, begging the question: which other elements (besides carbon) can be used to tune the surface for optimal methane binding without compromising the structure of the overall material? Boron and nitrogen were both explored and nitrogen was identified as the ideal agent for increasing methane binding to the optimal strength for use at near room temperature. Densification of the resulting materials by mechanical compaction was then explored to produce free-standing pellets with the highest methane “delivery” capacities of any known material. Here we define the amount “delivered” as the amount stored minus the amount remaining in the tank at 73 psi, the lowest useful pressure for vehicular transportation applications. The key features of the resulting methane storage system are rapid discharging and refueling speeds, extremely long cycle life (infinite cycle life for high-purity methane), a near-constant heat of refueling (making the heat generated upon refueling easier to manage), and a low maximum pressure of operation (<1500 psi), enabling the use of all-metal Type I cylinders and significantly reducing the costs of conversion of existing vehicles to cleaner burning, abundantly available natural gas). The technical effectiveness of this approach was further improved by exploring several cost-reduction strategies and investigating the reliability of such storage systems in the presence of “real” natural gas mixtures which contain a mixture of gaseous species.

03 NATURAL GAS↗