Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

THE CIRCULAR POLARIZATION OF SAGITTARIUS A* AT SUBMILLIMETER WAVELENGTHS

We report the first detections of circularly polarized emission at submillimeter wavelengths from the compact radio source and supermassive black hole candidate Sgr A* at a level of 1.2% {+-} 0.3% at 1.3 mm wavelength (230 GHz) and 1.6% {+-} 0.3% at 860 {mu}m (345 GHz) with the same handedness, left circular polarization (LCP), as observed at all lower frequencies (1.4-15 GHz). The observations, taken with the Submillimeter Array in multiple epochs, also show simultaneous linear polarization (LP) at both wavelengths of about 6%. These properties differ sharply from those at wavelengths longer than 1 cm (frequencies below 30 GHz), where weak circular polarization (CP) ({approx}0.5%) dominates over LP, which is not detected at similar fractional limits. We describe an extensive set of tests to ensure the accuracy of our measurements. We find no CP in any other source, including the bright quasar 1924-292, which traces the same path on the sky as Sgr A* and therefore should be subject to identical systematic errors originating in the instrument frame. Since a relativistic synchrotron plasma is expected to produce little CP, the observed CP is probably generated close to the event horizon by the Faraday conversion process. We use a simple approximation to show that the phase shift associated with Faraday conversion can be nearly independent of frequency, a sufficient condition to make the handedness of CP independent of frequency. Because the size of the {tau} = 1 surface changes by more than an order of magnitude between 1.4 and 345 GHz, the magnetic field must be coherent over such scales to consistently produce LCP. To improve our understanding of the environment of SgrA* critical future measurements includes determining whether the Faraday rotation deviates from a {lambda}{sup 2} dependence in wavelength and whether the circular and linear components of the flux density are correlated.

79 ASTRONOMY AND ASTROPHYSICS↗

Pre-accretional sorting of grains in the outer solar nebula

Despite their micrometer-scale dimensions and nanogram masses, chondritic porous interplanetary dust particles (CP IDPs) are an important class of extraterrestrial material since their properties are consistent with a cometary origin and they show no evidence of significant post-accretional parent body alteration. Consequently, they can provide information about grain accretion in the comet-forming region of the outer solar nebula. We have previously reported our comparative study of the sizes and size distributions of crystalline silicate and sulfide grains in CP IDPs, in which we found these components exhibit a size-density relationship consistent with having been sorted together prior to accretion. Here we extend our data set and include GEMS (glass with embedded metal and sulfide), the most abundant amorphous silicate phase observed in CP IDPs. We find that while the silicate and sulfide sorting trend previously observed is maintained, the GEMS size data do not exhibit any clear relationship to these crystalline components. Therefore, GEMS do not appear to have been sorted with the silicate and sulfide crystals. The disparate sorting trends observed in GEMS and the crystalline grains in CP IDPs present an interesting challenge for modeling early transport and accretion processes. They may indicate that several sorting mechanisms operated on these CP IDP components, or alternatively, they may simply be a reflection of different source environments.

79 ASTRONOMY AND ASTROPHYSICS↗

Necessity of macroscopic operation for the creation of superpositions of macroscopically distinct states

We consider the creation of superpositions of macroscopically distinct states by a completely positive (CP) operation on a subsystem. We conclude that the subsystem on which the CP operation acts must be macroscopically large if the success probability of the CP operation does not vanish in the thermodynamic limit. In order to obtain this conclusion, we show two inequalities, each of which represents a trade-off relation among the magnitude of an indicator for superpositions of macroscopically distinct states, the success probability of a CP operation, and the volume of the subsystem on which the CP operation acts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-momentum-transfer nonrelativistic limit of the relativistic impulse approximation expression for Compton-scattering doubly differential cross sections and characterization of their relativistic contributions

The nonrelativistic (nr) impulse approximation (NRIA) expression for Compton-scattering doubly differential cross sections (DDCS) for inelastic photon scattering is recovered from the corresponding relativistic expression (RIA) of Ribberfors [Phys. Rev. B 12, 2067 (1975)] in the limit of low momentum transfer (q{yields}0), valid even at relativistic incident photon energies {omega}{sub 1}>m provided that the average initial momentum of the ejected electron <p{sub i}> is not too high, that is, <p{sub i}> <m. This corresponds to a binding energy E{sub b}<10 keV. This q{yields}0 nr limit is simultaneous with the approach of the scattering angle {theta} to 0 deg. ({theta}{yields}0 deg.) around the Compton peak maximum. This explains the observation that it is possible to obtain an accurate Compton peak (CP) even when {omega}{sub 1}>m using nr expressions when {theta} is small. For example, a 1% accuracy can be obtained when {omega}{sub 1}=1 MeV if {theta}<20 deg. However as {omega}{sub 1} increases into the MeV range, the maximum {theta} at which an accurate Compton peak can be obtained from nr expressions approaches closer to zero, because the {theta} at which the relativistic shift of CP to higher energy is greatest, which starts at 180 deg. when {omega}{sub 1}<300 keV, begins to decrease, approaching zero even though the {theta} at which the relativistic increase in the CP magnitude remains greatest around {theta}=180 deg. The relativistic contribution to the prediction of Compton doubly differential cross sections (DDCS) is characterized in simple terms using Ribberfors further approximation to his full RIA expression. This factorable form is given by DDCS=KJ, where K is the kinematic factor and J the Compton profile. This form makes it possible to account for the relativistic shift of CP to higher energy and the increase in the CP magnitude as being due to the dependence of J(p{sub min},{rho}{sub rel}) (where p{sub min} is the relativistic version of the z component of the momentum of the initial electron and {rho}{sub rel} is the relativistic charge density) and K(p{sub min}) on p{sub min}. This characterization approach was used as a guide for making the nr QED S-matrix expression for the Compton peak kinematically relativistic. Such modified nr expressions can be more readily applied to large systems than the fully relativistic version.

74 ATOMIC AND MOLECULAR PHYSICS↗

Emergence of longitudinal 7-branes and fuzzy S{sup 4} in compactification scenarios of M(atrix) theory

In M(atrix) theory, there exist membranes and longitudinal 5-branes (L5-branes) as extended objects. Transverse components of these brane solutions are known to be described by fuzzy CP{sup k} (k=1, 2), where k=1 and k=2 correspond to spherical membranes and L5-branes of CP{sup 2}xS{sup 1} world-volume geometry, respectively. In addition to these solutions, we here show the existence of L7-branes of CP{sup 3}xS{sup 1} geometry, introducing extra potentials to the M(atrix) theory Lagrangian. As in the cases of k=1, 2, the L7-branes (corresponding to k=3) also break the supersymmetries of M(atrix) theory. The extra potentials are introduced such that the energy of a static L7-brane solution becomes finite in the large N limit where N represents the matrix dimension of fuzzy CP{sup 3}. As a consequence, fluctuations from the L7-branes are suppressed, which effectively describes compactification of M(atrix) theory down to 7 dimensions. We show that one of the extra potentials can be considered as a matrix-valued 7-form. The presence of the 7-form in turn supports a possibility of Freund-Rubin type compactification. This suggests that our modification of M(atrix) theory can also lead to a physically interesting matrix model in four dimensions. In hope of such a possibility, we further consider compactification of M(atrix) theory down to fuzzy S{sup 4} which can be defined in terms of fuzzy CP{sup 3}. Along the way, we also find a new L5-brane solution to M(atrix) theory which has purely spherical geometry in the transverse directions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for mixing-induced C P violation using partial reconstruction of B ¯ 0 → D * + X ℓ - ν ¯ ℓ and kaon tagging

We describe in detail a previously published measurement of CP violation in B 0 -B¯ 0 oscillations, based on an integrated luminosity of 425.7 fb -1 collected by the BABAR experiment at the PEPII collider. We apply a novel technique to a sample of about 6 million B¯ 0 →D* + ℓ - ν ℓ ¯ decays selected with partial reconstruction of the D*+ meson. The charged lepton identifies the flavor of one B meson at its decay time, the flavor of the other B is determined by kaon tagging. We determine a CP violating asymmetry ACP=(N(B0B0)-N(B¯ 0 B¯ 0 ))/(N(B 0 B 0 )+N(B¯ 0 B¯ 0 ))=(0.06±0.17 +0.38 -0.32 )% corresponding to Δ CP =1-|q/p|=(0.29±0.84 +1.88 -1.61 )×10 -3 . This measurement is consistent and competitive with those obtained at the B factories with dilepton events.

Experiment-HEP,HEPEX↗

Evidence for C P violation in B + → K * ( 892 ) + π 0 from a Dalitz plot analysis of B + → K S 0 π + π 0 decays

We report a Dalitz plot analysis of charmless hadronic decays of charged B mesons to the final state K 0 S π + π 0 using the full BABAR data set of 470.9 ± 2.8 million B¯B events collected at the Υ(4S) resonance. We measure the overall branching fraction and CP asymmetry to be B(B + → K 0 π + π 0 ) = (31.8 ± 1.8 ± 2.1 +6.0 –0.0 ) × 10 –6 and A CP (B + → K 0 π + π 0 ) = 0.07 ± 0.05 ± 0.03 +0.02 –0.03 , where the uncertainties are statistical, systematic, and due to the signal model, respectively. This is the first measurement of the branching fraction for B + → K 0 π + π 0 . We find first evidence of a CP asymmetry in B + → K*(892) + π 0 decays: A CP (B + → K*(892) + π 0 ) = –0.52 ± 0.14 ± 0.04 +0.04 –0.02 . The significance of this asymmetry, including systematic and model uncertainties, is 3.4 standard deviations. As a result, we also measure the branching fractions and CP asymmetries for three other intermediate decay modes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of C P Violation in Charm Decays

A search for charge-parity $(CP)$ violation in $D^0 → K^–K^+$ and $D^0 → π^–π^+$ decays is reported, using $p p$ collision data corresponding to an integrated luminosity of 5.9 fb –1 collected at a center-of-mass energy of 13 TeV with the LHCb detector. The flavor of the charm meson is inferred from the charge of the pion in $D^*(2010)^+ → D^0π^+$ decays or from the charge of the muon in $\overline B → D^0μ^–\overline ν_μX$ decays. The difference between the $CP$ asymmetries in $D^0 → K^–K^+$ and $D^0 → π^–π^+$ decays is measured to be $ΔA_{CP} = [–18.2 ± 3.2($stat$) ± 0.9($syst$)] × 10^{–4}$ for $π$-tagged and $ΔACP = [–9 ± 8($stat$) ± 5($syst$)] × 10^{–4}$ for $μ-$ tagged $D^0$ mesons. Combining these with previous LHCb results leads to $ΔA_{CP} = (–15.4 ± 2.9) × 10^{–4}$, where the uncertainty includes both statistical and systematic contributions. The measured value differs from zero by more than 5 standard deviations. This is the first observation of $CP$ violation in the decay of charm hadrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test of Superconducting Wires and Rutherford Cables With High Specific Heat

High-field accelerator magnets made of state-of-the-art Nb 3 Sn Rutherford cables demonstrate relatively long trainings due to sudden heat depositions originated by thermo-mechanical perturbations in the magnet coils. Coil sensitivity to these perturbations can be reduced by increasing the specific heat, Cp, of major coil components - strands, or whole cable, or epoxy. The R&D on all these three approaches is in progress. This paper studies feasibility of increasing the Cp of Rutherford-type cables by using a thin composite Cu/Gd 2 O 3 tape. The tape can be either wrapped around the cable, placed on the cable wide faces under the insulation, and/or inserted as a core. In this work, Cu/Gd 2 O 3 ribbons with ~30% of Gd 2 O 3 powder and two different thicknesses were produced by Hyper Tech Research, Inc. Wire and cable samples outfitted with these high-Cp ribbons, or tapes, were prepared and tested at FNAL for the Minimum Quench Energy (MQE). At 80%Ic, the MQE gain average over the tested magnetic field range of the NbTi cable with high-Cp tape on both sides was ~1.3. The MQE gain average of the NbTi wire wrapped with the high-Cp ribbon was 3.1.

43 PARTICLE ACCELERATORS↗

SU-D-18C-01: A Novel 4D-MRI Technology Based On K-Space Retrospective Sorting

Purpose: Current 4D-MRI techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of an entirely new framework of 4D-MRI based on k-space retrospective sorting. Methods: An important challenge of the proposed technique is to determine the number of repeated scans(NR) required to obtain sufficient k-space data for 4D-MRI. To do that, simulations using 29 cancer patients' respiratory profiles were performed to derive the relationship between data acquisition completeness(Cp) and NR, also relationship between NR(Cp=95%) and the following factors: total slice(NS), respiratory phase bin length(Lb), frame rate(fr), resolution(R) and image acquisition starting-phase(P0). To evaluate our technique, a computer simulation study on a 4D digital human phantom (XCAT) were conducted with regular breathing (fr=0.5Hz; R=256×256). A 2D echo planer imaging(EPI) MRI sequence were assumed to acquire raw k-space data, with respiratory signal and acquisition time for each k-space data line recorded simultaneously. K-space data was re-sorted based on respiratory phases. To evaluate 4D-MRI image quality, tumor trajectories were measured and compared with the input signal. Mean relative amplitude difference(D) and cross-correlation coefficient(CC) are calculated. Finally, phase-sharing sliding window technique was applied to investigate the feasibility of generating ultra-fast 4D-MRI. Result: Cp increased with NR(Cp=100*[1-exp(-0.19*NR)], when NS=30, Lb=100%/6). NR(Cp=95%) was inversely-proportional to Lb (r=0.97), but independent of other factors. 4D-MRI on XCAT demonstrated highly accurate motion information (D=0.67%, CC=0.996) with much less artifacts than those on image-based sorting 4D-MRI. Ultra-fast 4D-MRI with an apparent temporal resolution of 10 frames/second was reconstructed using the phase-sharing sliding window technique. Conclusions: A novel 4D-MRI technology based on k-space sorting has been successfully developed and evaluated on the digital phantom. Framework established can be applied to a variety of MR sequences, showing great promises to develop the optimal 4D-MRI technique for many radiation therapy applications. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

SU-E-T-398: Feasibility of Automated Tools for Robustness Evaluation of Advanced Photon and Proton Techniques in Oropharyngeal Cancer

Purpose: Advanced radiotherapy (RT) techniques such as proton pencil beam scanning (PBS) and photon-based volumetric modulated arc therapy (VMAT) have dosimetric advantages in the treatment of head and neck malignancies. However, anatomic or alignment changes during treatment may limit robustness of PBS and VMAT plans. We assess the feasibility of automated deformable registration tools for robustness evaluation in adaptive PBS and VMAT RT of oropharyngeal cancer (OPC). Methods: We treated 10 patients with bilateral OPC with advanced RT techniques and obtained verification CT scans with physician-reviewed target and OAR contours. We generated 3 advanced RT plans for each patient: proton PBS plan using 2 posterior oblique fields (2F), proton PBS plan using an additional third low-anterior field (3F), and a photon VMAT plan using 2 arcs (Arc). For each of the planning techniques, we forward calculated initial (Ini) plans on the verification scans to create verification (V) plans. We extracted DVH indicators based on physician-generated contours for 2 target and 14 OAR structures to investigate the feasibility of two automated tools (contour propagation (CP) and dose deformation (DD)) as surrogates for routine clinical plan robustness evaluation. For each verification scan, we compared DVH indicators of V, CP and DD plans in a head-to-head fashion using Student's t-test. Results: We performed 39 verification scans; each patient underwent 3 to 6 verification scan. We found no differences in doses to target or OAR structures between V and CP, V and DD, and CP and DD plans across all patients (p > 0.05). Conclusions: Automated robustness evaluation tools, CP and DD, accurately predicted dose distributions of verification (V) plans using physician-generated contours. These tools may be further developed as a potential robustness screening tool in the workflow for adaptive treatment of OPC using advanced RT techniques, reducing the need for physician-generated contours.

60 APPLIED LIFE SCIENCES↗

Parameterization of photon beam dosimetry for a linear accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modeled data, (3) the quality assurance process of a linear accelerator’s (Linac) beam characteristics, (4) the establishment of a standard data set for comparison with other data, etcetera. Parameterization of the photon beam dosimetry creates a data set that is portable and easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon beam dosimetric quantities, including percentage depth doses (PDDs), profiles, and total scatter output factors (S{sub cp}). Methods: S{sub cp}, PDDs, and profiles for different field sizes, depths, and energies were measured for a Linac using a cylindrical 3D water scanning system. All data were smoothed for the analysis and profile data were also centered, symmetrized, and geometrically scaled. The S{sub cp} data were analyzed using an exponential function. The inverse square factor was removed from the PDD data before modeling and the data were subsequently analyzed using exponential functions. For profile modeling, one halfside of the profile was divided into three regions described by exponential, sigmoid, and Gaussian equations. All of the analytical functions are field size, energy, depth, and, in the case of profiles, scan direction specific. The model’s parameters were determined using the minimal amount of measured data necessary. The model’s accuracy was evaluated via the calculation of absolute differences between the measured (processed) and calculated data in low gradient regions and distance-to-agreement analysis in high gradient regions. Finally, the results of dosimetric quantities obtained by the fitted models for a different machine were also assessed. Results: All of the differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 and 0.5 mm, respectively. The differences in the low gradient regions were 0.20% ± 0.20% (<1% for all) and 0.50% ± 0.35% (<1% for all) for PDDs and profiles, respectively. For S{sub cp} data, all of the absolute differences were less than 0.5%. Conclusions: This novel analytical model with minimum measurement requirements was proved to accurately calculate PDDs, profiles, and S{sub cp} for different field sizes, depths, and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-36: Comparison of Ball Bearing and Iso-Cube Phantoms for KV-MV Iso-Center Coincidence Check

Purpose: To compare two different quality assurance tools for kV-MV isocenter coincidence check. Methods: Ball-Bearing device (BBD) (Elekta) provided along with a CBCT equipped LINAC and isocenter cube phantom (CP) (a commercial product of Modus Medical Devices) are utilized to check the coincidence between the MV and kV beam isocenters. The microstepping meter of the BBD allows precision adjustment to better than 0.01mm in three directions. The BBD is aligned to the MV-isocenter with the lasers and followed by taking MV-images of at two collimator angles at each cardinal gantry, then its position adjusted. This process takes in iterative steps until 0.25mm tolerance is achieved. Four planar kV-images are taken at cardinal angles and deviations of BBD position from kVisocenter are evaluated. CP is positioned on the couch with the lasers at known offset from the isocenter. CBCT is utilized to set the cube to its kV isocenter with the precision of linac’s couch (1mm). MV-images are taken at various gantry, collimator, and couch angles and evaluated with the CP manufacturer provided QA software to determine coincidence of the 6mm steel ball at cube center with MV-isocenter. Three sets of measurements, one after another, were performed on the same day for each phantom on the same linac. Results: Assuming little variation between kV and MV isocenters in a short time, BBD measurements are more reproducible than CP. With comparable conditions both methods agree within 0.5 mm in each direction, while for BBD average standard deviation was 0.07mm and for iso-cube 0.3mm. Conclusion: Since BBD is more reliable and its results are more reproducible, it should be used during the monthly QA. Since CP is a more efficient device, it should be used for daily QA. A comparison study between the two devices should be periodically performed.

60 APPLIED LIFE SCIENCES↗

Chimeric Fatty Acyl-Acyl Carrier Protein Thioesterases Provide Mechanistic Insight into Enzyme Specificity and Expression

Medium-chain fatty acids are commodity chemicals. Increasing and modifying the activity of thioesterases (TEs) on medium-chain fatty acyl-acyl carrier protein (acyl-ACP) esters may enable a high-yield microbial production of these molecules. The plant Cuphea palustris harbors two distinct TEs: C. palustris FatB1 ( Cp FatB1) (C 8 specificity, lower activity) and Cp FatB2 (C 14 specificity, higher activity) with 78% sequence identity. We combined structural features from these two enzymes to create several chimeric TEs, some of which showed nonnatural fatty acid production as measured by an enzymatic assay and gas chromatography-mass spectrometry (GC-MS). Substantially, chimera 4 exhibited an increased C 8 fatty acid production in correlation with improved microbial expression. This chimera led us to identify Cp FatB2-specific amino acids between positions 219 and 272 that lead to higher protein levels. Chimera 7 produced a broad range of fatty acids and appeared to combine a fatty acid binding pocket with long-chain specificity and an ACP interaction site that may activate fatty acid extrusion. Using homology modeling and in silico docking with ACP, we identified a “positive patch” within amino acids 162 to 218, which may direct the ACP interaction and regulate access to short-chain fatty acids. On the basis of this modeling, we transplanted putative ACP interaction sequences from Cp FatB1 into Cp FatB2 and created a chimeric thioesterase that produced medium-chain as well as long-chain fatty acids. Hence, the engineering of chimeric enzymes and characterizing their microbial activity and chain-length specificity suggested mechanistic insights into TE functions and also generated thioesterases with potentially useful properties. These observations may inform a rational engineering of TEs to allow alkyl chain length control. IMPORTANCE: Medium-chain fatty acids are important commodity chemicals. These molecules are used as plastic precursors and in shampoos and other detergents and could be used as biofuel precursors if production economics were favorable. Hydrocarbon-based liquid fuels must be optimized to have a desired boiling point, low freezing point, low viscosity, and other physical characteristics. Furthermore, the solubility and harshness of detergents and the flexibility of plastic polymers can be modulated. The length and distribution of the carbon chains in the hydrophobic tails determine these properties. The biological synthesis of cell membranes and fatty acids produces chains of primarily 16 to 18 carbons, which give rise to current biofuels. The ultimate goal of the work presented here is to engineer metabolic pathways to produce designer molecules with the correct number of carbons in a chain, so that such molecules could be used directly as specialty commodity chemicals or as fuels after minimal processing.

59 BASIC BIOLOGICAL SCIENCES↗

Two Leading ENSO Modes and El Niño Types in the Zebiak–Cane Model

Modern instrumental records reveal that El Niño events differ in their spatial patterns and temporal evolutions. Attempts have been made to categorize them roughly into two main types: eastern Pacific (EP; or cold tongue) and central Pacific (CP; or warm pool) El Niño events. In this study, a modified version of the Zebiak–Cane (MZC) coupled model is used to examine the dynamics of these two types of El Niño events. Linear eigenanalysis of the model is conducted to show that there are two leading El Niño–Southern Oscillation (ENSO) modes with their SST patterns resembling those of two types of El Niño. Thus, they are referred to as the EP and CP ENSO modes. These two modes are sensitive to changes in the mean states. The heat budget analyses demonstrate that the EP (CP) mode is dominated by thermocline (zonal advective) feedback. Therefore, the weak (strong) mean wind stress and deep (shallow) mean thermocline prefer the EP (CP) ENSO mode because of the relative dominance of thermocline (zonal advective) feedback under such a mean state. Consistent with the linear stability analysis, the occurrence ratio of CP/EP El Niño events in the nonlinear simulations generally increases toward the regime where the linear CP ENSO mode has relatively higher growth rate. These analyses suggest that the coexistence of two leading ENSO modes is responsible for two types of El Niño simulated in the MZC model. This model result may provide a plausible scenario for the observed ENSO diversity.

Meteorology & Atmospheric Sciences↗

Making tensor factorizations robust to non-gaussian noise.

Tensors are multi-way arrays, and the CANDECOMP/PARAFAC (CP) tensor factorization has found application in many different domains. The CP model is typically fit using a least squares objective function, which is a maximum likelihood estimate under the assumption of independent and identically distributed (i.i.d.) Gaussian noise. We demonstrate that this loss function can be highly sensitive to non-Gaussian noise. Therefore, we propose a loss function based on the 1-norm because it can accommodate both Gaussian and grossly non-Gaussian perturbations. We also present an alternating majorization-minimization (MM) algorithm for fitting a CP model using our proposed loss function (CPAL1) and compare its performance to the workhorse algorithm for fitting CP models, CP alternating least squares (CPALS).

97 MATHEMATICS AND COMPUTING↗

Measurements of charmless b-hadron decays at CDF; first evidence for the annihilation $B^0_s \to \pi^+ \pi^-$ decay mode.

In this thesis I report on several results obtained from an accurate analysis of the $Bhh$ data sample: Annihilation decay modes: using 6 fb$^{-1}$ of data collected by the CDF experiment, I obtained the first evidence of the $B_s^0\to \pi^+ \pi^-$ decay mode, with a significance of about 3.7$\sigma$, and I performed the most precise measurement of the Branching Ratio of the $B_d^0\to K^+ K^-$ decay mode at the time, corresponding to an excess of 2$\sigma$ level. These measurements have important consequences as discussed in the previous sections: the comparison between these branching fractions and the theoretical predictions provides unique information for tuning the phenomenological models. Our results prompted intense theoretical work both using pQCD and QCDF approaches to accommodate the discrepancies between predictions and experimental results. CP violation: using the full CDF 10 fb$^{-1}$ of data collected by the CDF experiment, I found evidence of the \textbf{CP violation} of $B_s^0 \to K \pi$ decay mode, with a significance of 3$\sigma$, confirming the result recently obtained at LHCb. I also measured the CP asymmetries of the $B_d^0 \to K \pi$ decay modes, in agreement and of comparable resolution with the b-factories experiments, while the most precise measurement up to date is from LHCb. The precision reached in the Acp($B_s^0 \to K \pi$ ) measurement gives the possibility to perform interesting checks of the Standard Model predictions, explained in the previous sections. I also obtained the world's best measurements of the CP asymmetries in $\Lambda_b^0 \to p\pi$ and $\Lambda_b^0 \to pK$ decay modes. These measurements are unique and represent a step forward in the understanding of the \CP\ violation phenomena in the relatively unexplored $\Lambda_b^0$ sector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗