Wear and Corrosion Behavior of Graphene-Nanoplate-Reinforced Copper Matrix Composites Prepared Through Electrostatic Self-Assembly

Synthesis of graphene nanoplates (GNPs)/copper (Cu) composites is one of the key challenges in the uniform dispersion of GNPs in the Cu matrix because of their density difference. In this work, GNPs/Cu composites are synthesized through electrostatic self-assembly and spark plasma sintering. The GNPs are uniformly dispersed in the Cu matrix. The graphene protective films are formed in the composites to protect the Cu matrix. The antifriction performance of the GNPs/Cu composites is investigated using a ball-on-disk apparatus. The corrosion resistance of the GNPs/Cu composites is estimated using potentiodynamic polarization curves. Wear and corrosion mechanisms are analyzed through scanning electron microscopy with energy-dispersive spectroscopy. The antifriction performance and corrosion resistance of the composites can be significantly improved by adding GNPs.

36 MATERIALS SCIENCE↗

Corrosion Behavior of a Reactive Bond Between Stainless Steel and a Cast AlCeMg Alloy

Corrosion is a longstanding issue for metal components, especially those used in heat exchanger applications. Al–Ce–Mg alloys may provide a potential solution to this problem due to their good mechanical properties and potential reaction bonding with other metals. The reaction bonding involves a “reactive” bond that occurs upon casting of Al–Ce–Mg alloy over stainless steel (SS). Here this study examined the corrosion response of Al–2Ce–6Mg (atomic percent)/(SS) reactive bond interfaces after samples were completely submerged in nitric, sulfuric, formic, and mixed acids for 267 h. Scanning electron microscopy revealed that in the as-cut condition, reactive bond formations were seen frequently throughout the length of the casting and maintained a secure bond between the alloy and the SS tubes. Furthermore, the nitric, sulfuric, and the mixed acids did not have a deleterious effect on the reactive bond structure. However, formic acid did produce changes in both the microstructural appearance and the elemental profile across the bond due to the formation of corrosion reaction products on the acid-exposed surface.

36 MATERIALS SCIENCE↗

Mechanism of the α-Zr to hexagonal-ZrO transformation and its impact on the corrosion performance of nuclear Zr alloys

Displacive transformations have been widely reported in metals, alloys and ceramics, but rarely reported to be important in the aqueous corrosion of alloys. We report here our analysis of the formation of the hexagonal-ZrO suboxide during the aqueous corrosion of α-Zr alloys and propose this to be a paraequilibrium displacive transformation with the rate controlled by oxygen diffusion. Two orientation relationships were identified between α-Zr and hexagonal-ZrO, ( 0002 ) α − Z r ∥ ( 1 ¯ 011 ) h − Z r O and [ 2 ¯ 110 ] α - Z r ∥ [ 10 1 ¯ 2 ] h - Z r O or ( 0002 ) α − Z r ∥ ( 22 4 ¯ 1 ¯ ) h − Z r O and [ 2 ¯ 110 ] α − Z r ∥ [ 1 1 ¯ 01 ] h − Z r O , with the first one more commonly observed. No specific orientation relationships between either hexagonal-ZrO and monoclinic-ZrO 2 or α-Zr and monoclinic-ZrO 2 were identified, which suggests that the formation of often-reported bulk oxide texture during aqueous corrosion is not related directly to the texture of the metallic substrate. In conclusion, these results provide a guideline for understanding the mechanisms of crystallographic evolution during oxide growth on commercial zirconium alloys, and also demonstrate the capability of transmission Kikuchi diffraction to investigate orientation relationships in nano-scale materials.

36 MATERIALS SCIENCE↗

Morphologies of dealloying corrosion attack at grain boundaries

Dealloying corrosion at grain boundaries severely compromises the performance of polycrystalline materials across a wide variety of technological applications. The impact of this phenomenon depends upon the morphology and rate of intergranular dealloying, which can range from planar to wormhole-like patterns that rapidly advance into the alloy. Using 2D and 3D multi-phase field simulations, we reveal how diverse microstructures result from a fundamental interplay between alloy composition and a grain boundary migration mechanism that alters diffusional pathways of dealloying. Inside intergranular dealloying channels, corrosion product buildup can spawn new channels that branch into grain interiors, such that alloys can be degraded from the inside out. These processes further lead to an atypical coarsening mode assisted by diffusion in the dealloying agent. We summarize a unifying explanation for dealloying morphology selection in polycrystalline alloys, which provides an important step towards their optimization for dealloying corrosion environments.

Corrosion↗

Application of gamma-ray radiography and gravimetric measurements after accelerated corrosion tests of steel embedded in mortar

The accelerated corrosion by the impressed current technique is widely used in studies of concrete durability since it has the advantage that tests can be carried out within reasonable periods of time. In the present work the relationship between the applied current density and the resulting damage on the reinforcing steel, by applying optical microscopy, scanning electron microscopy, gamma-ray radiography and gravimetric measurements, was studied by means of the implementation of accelerated corrosion tests on reinforced mortar. The results show that the efficiency of the applied current is between 1 and 77%, regardless of the applied current density, the water/cement ratio and the mortar cover depth of the specimens. The results show the applicability of the gamma-ray radiography technique to detect localized corrosion of steel rebars in laboratory specimens.

36 MATERIALS SCIENCE↗

Effect of soluble inhibitors on the corrosion behaviour of galvanized steel in fresh concrete

Highlights: • Metastable passivation of galvanized steel occurs immediately in concrete with Cr VI ≥ 15 ppm. • Stable passivation of galvanized steel in concrete with Cr VI ≥ 6 ppm occurs in three steps. • Nitrite decreases hydrogen evolution by moving corrosion potential to more positive values. • Nitrite favours the formation of a compact layer of CHZ, which leads to a stable passivation. • DEA and MoO{sub 4}{sup 2-} do not have significant effect on the passivation time of galvanized steel. - Abstract: The effect of some soluble inhibitors on the passivation time of galvanized steel reinforcements in fresh concrete was studied in order to reduce H{sub 2} evolution associated with the active corrosion. The investigation was performed by means of corrosion potential monitoring, scanning electron microscopy, energy-dispersive X-ray spectroscopy and X-ray diffraction analysis. The obtained results indicate that the passivation of galvanized steel in concrete containing chromates occurs in three steps with different mechanisms and that dissolved oxygen is necessary for the beginning of passivation process. Among the inhibitors studied as alternative to Cr VI, nitrite seem the most promising one, even if it is less effective than chromate. Diethanolamine and molybdate ions do not have significant effect on the passivation time of galvanized steel in fresh concrete.

36 MATERIALS SCIENCE↗

Influence of surface modifications on pitting corrosion behavior of nickel-base alloy 718. Part 1: Effect of machine hammer peening

The effect of surface modifications induced by machine hammer peening on pitting corrosion behavior of nickel-base alloy 718 in a 3.5 wt.% NaCl solution is investigated. Severe work hardening and high compressive residual stress are generated with surface smoothing and microstructure evolution in terms of formation of nano-grains and nano-twins in the near surface region after machine hammer peening. Electrochemical tests results show that machine hammer peening has a beneficial influence on the corrosion resistance, indicated by a significant increase of the critical pitting potential (+134 mV) accompanied with lower corrosion current density and higher polarization resistance.

36 MATERIALS SCIENCE↗

Measurement of Localized Corrosion Rates at Inclusion Particles in AA7075 by In Situ Three Dimensional (3D) X-ray Synchrotron Tomography

In situ X-ray synchrotron tomography was used to measure the localized corrosion rate of Mg2Si particles present in 7075 aluminum alloys in deionized ultra-filtered (DIUF) water. The evolution of hydrogen bubbles was captured as a function of time and the measured volume was used to calculate the local corrosion rate of Mg2Si particles. It was shown that in the absence of chloride ions, stress was needed to create fresh particle surfaces, either by fracture or debonding, to initiate corrosion at the particles.

A. Aluminum alloys↗

Homogenization of Al x CoCrFeNi high-entropy alloys with improved corrosion resistance

The present work investigates the homogenization effect of 1250 °C heat treatment on the Al x CoCrFeNi high-entropy alloys (HEAs). The multi-phase microstructures with chemical segregations are inevitable with the increased Al content in the alloys, which cause work function variations and localized corrosion. After heat treatment, the homogenization effect revealed by the microstructure simplification and chemical-segregation reduction leads to the decreased work function variations and the improved corrosion resistance. Furthermore, thermodynamic calculations that are reliable to predict the phase transformations of the Al x CoCrFeNi HEAs, indicates a further enhancement in corrosion resistance through annealing could be guided for many other HEAs systems.

36 MATERIALS SCIENCE↗

Investigation of impurity driven corrosion behavior in molten 2LiF-BeF 2 salt

A 1000 -h corrosion experiment of 316H stainless steel at 700 °C investigated the role of metal fluoride impurities CrF 2 and FeF 2 in LiF-BeF 2 (66-34 mole %) (FLiBe) salt. Inductively coupled plasma-optical emission spectroscopy (ICP-OES) demonstrated the ability to measure changes in the concentration of these fluorides in FLiBe salt. Cyclic voltammetry (CV) showed the potential for real-time quantitative concentration measurement of corrosion products in the molten salt. Materials characterization revealed that both impurity species influence the dissolution of Cr from the alloy. The collective results from these analysis methods advance the understanding of the influence impurities have on materials corrosion.

2LiF-BeF2↗

Non-galvanic mass transport in molten fluoride salt isothermal corrosion cells

Mass transport of corrosion products between Ni-201 test samples and 316 L capsules in a 500-hour FLiNaK corrosion experiment has been investigated. In one experiment, the capsule and samples were electrically connected for galvanic coupling, while in the other they were electrically isolated using boron-nitride. Post-corrosion characterization of Ni-201 from the two experiments did not reveal any remarkable differences. Substantial transport of Fe and Cr from the 316 L to the Ni-201 via the salt was observed, with notable diffusion of these elements in the near-surface regions of the Ni-201 samples, while a Cr-rich film was also observed on their surfaces.

36 MATERIALS SCIENCE↗

Comparison of Na 2 SO 4 , K 2 SO 4 and Na 2 SO 4 -K 2 SO 4 deposit induced hot corrosion of a β-NiAl coating

Here, hot corrosion behaviour of a β-NiAl coating induced by Na 2 SO 4 , K 2 SO 4 , and Na 2 SO 4 -K 2 SO 4 deposits was investigated at 700 °C in air + 300 ppm SO 2 . To provide an insight into the corrosion mechanisms, phase equilibria of the Na 2 SO 4 -K 2 SO 4 -NiO-SO 3 system were calculated using an in-house developed thermodynamic database. The attack rates and morphologies could be correlated with the deposit compositions and their reactions with oxides. K 2 SO 4 and Na 2 SO 4 -K 2 SO 4 deposits are more corrosive than Na 2 SO 4 . This is attributed to a reduction of the melting temperature of the deposit and the formation of Ni-containing mixed sulphate phases in the presence of K 2 SO 4 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of metal fluorides on the corrosion of structural materials in molten LiF-NaF-KF

The corrosion of structural materials in molten fluoride salts is predominantly caused by the presence of impurities in the salt. Here, this study focuses on understanding the corrosion behavior of selected alloys in molten FLiNaK salt with addition of similar quantities of metal fluoride impurities such as CrF 2 , CrF 3 , FeF 2 , FeF 3 , and NiF 2 . The results show that the presence of selected metal fluoride impurities increases the extent of corrosion of the selected alloys in molten FLiNaK salt, with the exact effect depending on the thermodynamic stability of the fluoride impurity added as well as the composition of the structural alloy studied.

36 MATERIALS SCIENCE↗

Influence of native oxide film on corrosion behavior of additively manufactured stainless steel 316L

The influence of the native oxide film on passive film properties and localized corrosion of additively manufactured SS 316L was studied in 1 wt% HCl by XPS characterization, electrochemical polarization curves, and post-test morphology analysis by SEM. Increased Cr oxidation kinetics was observed in the as-polished sample with the native oxide film resulting in formation of an overall more protective and compact film compared to the cathodically-activated sample. Electrochemical analysis showed that corrosive attack varied between dislocation cell boundaries to cell interiors depending on the initial surface state and polarization conditions. In conclusion, a corrosion mechanism is proposed to explain this variation.

36 MATERIALS SCIENCE↗

Corrosion characteristics of silicon carbide fiber-reinforced composites in beryllium-bearing molten fluoride salt

Corrosion of SiC-fiber reinforced SiC matrix composites in 2LiF-BeF 2 molten salt was examined following static molten salt exposure for 1000 h at 650 and 750 °C. Composites were fabricated with either Tyranno SA3 or Hi-Nicalon type-S fibers and a chemical vapor infiltration SiC matrix. Both composites showed minimal weight loss after salt exposure and maintained shape. Corrosion was characterized by comprehensive electron microscopy and Raman spectroscopy. In conclusion, based on the results of experimental and thermodynamic analysis, a corrosion mechanism for SiC/SiC is proposed where both the salt and SiC materials play a key role in the phase stability of the composite.

36 MATERIALS SCIENCE↗

Localized Corrosion Behavior of Non-Equiatomic NiFeCrMnCo Multi-Principal Element Alloys

A series of single phase Ni 38 Fe 20 Cr x Mn 21–0.5x Co 21–0.5x multi-principal element alloys (MPEAs) were fabricated and their localized corrosion behavior was tested in 0.6 M NaCl solution. These MPEAs were found to be susceptible to localized corrosion, exhibiting pitting at room temperature, as indicated by positive hysteresis loops and low repassivation potentials observed in cyclic potentiodynamic polarization experiments. The pitting resistance increased with increasing Cr content. Interestingly, even the MPEAs with low chromium content, Ni 38 Fe 20 Cr 6 Mn 18 Co 18 and Ni 38 Fe 20 Cr 10 Mn 16 Co 16 , exhibited passivity and localized corrosion. Here, the passivity observed in these low chromium MPEAs is likely derived from their relatively high nickel content. Crystallographic pit morphology was observed in most of these MPEAs, suggesting the absence of a salt film on the dissolving pit surface. Such crystallographic pit morphology indicates that the pit growth in most of these MPEAs was under charge-transfer/ohmic control.

36 MATERIALS SCIENCE↗

Niobium addition improves the corrosion resistance of TiHfZrNb x high-entropy alloys in Hanks’ solution

High-strength TiHfZrNb x high-entropy alloys could become the ideal materials for small-diameter endovascular stents once their corrosion resistance in the physiological milieu is confirmed. Here, this work aims at evaluating the corrosion resistance of a TiHfZrNb x high-entropy-alloys family in Hanks’ solution at 37 °C and revealing the influence of niobium on the mechanisms of dissolution and passivation. The alloys were subjected to a series of static and dynamic electrochemical tests and surface characterization, employing the static/dynamic/cyclic polarizations, impedance spectroscopy, XPS, AFM, and SEM. Results confirm a higher corrosion resistance of the alloys compared to that of CP-Ti and Ti6Al4V. The addition of niobium considerably improves the microstructural homogeneity that ensures a low dissolution rate and a greater resistance of the film due to the lower concentration of point defects. The passive film behaves as an n-type semiconductor and is composed of a mixture of TiO 2 , Nb 2 O 5 , ZrO 2 , and HfO 2 oxides, with the presence of metallic hydroxides on the outermost layer. A detailed description of the niobium influence on the mechanisms of the dissolution and passivation is presented in this work.

36 MATERIALS SCIENCE↗

A methodology for corrosion testing ODS steels in liquid tin under reactor conditions in HFIR

Liquid metal–based divertor concepts have promising attributes for application in fusion reactors. Liquid tin is being considered as one of those liquid metals due to its excellent thermophysical properties. However, tin is extremely corrosive to steels at elevated temperatures, and the coupled effects of corrosion with neutron irradiation for application in fusion reactors have not been quantified. Researchers at Oak Ridge National Laboratory (ORNL) have designed and irradiated a series of capsules in the High Flux Isotope Reactor (HFIR) to help address gaps in the literature with respect to coupled corrosion and neutron irradiation effects. The capsules are filled with solid tin designed to melt due to the gamma heating in HFIR and allow interaction with the specimens. The capsules contain a SiC thermometer for post-irradiation temperature verification. Five capsules were irradiated in HFIR for 10.5 days, accumulating 0.93 dpa in the FeCrAl specimens. Post-irradiation temperature verification was performed on the SiC thermometers, and temperatures were observed to be higher than what was expected from thermal models. An explanation for the model underprediction is given herein. In conclusion, the capsules described within this article are the first to irradiate liquid metal within the HFIR flux trap and demonstrated the safety basis for continued liquid coolant studies in HFIR.

FeCrAl↗