Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORRECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Correction to: Information Transmission and Criticality in the Contact Process

The original publication of the article unfortunately contained a mistake in the first sentence of Theorem 1 and in the second part of the proof of Theorem 1. The corrected statement of Theorem as well as the corrected proof are given below. The full text of the corrected version is available at http://arxiv.org/abs/1705.11150.

97 MATHEMATICS AND COMPUTING↗

Error correction in short time steps during the application of quantum gates

We propose a modification of the standard quantum error-correction method to enable the correction of errors that occur due to the interaction with a noisy environment during quantum gates without modifying the codification used for memory qubits. Using a perturbation treatment of the noise that allows us to separate it from the ideal evolution of the quantum gate, we demonstrate that in certain cases it is necessary to divide the logical operation in short time steps intercalated by correction procedures. A prescription of how these gates can be constructed is provided, as well as a proof that, even for the cases when the division of the quantum gate in short time steps is not necessary, this method may be advantageous for reducing the total duration of the computation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Higher order corrected thermodynamics and statistics of Kerr–Newman–Gödel black hole

In this paper, we consider the rotating charged Gödel black hole and study the effect of the higher order corrections of the entropy on the thermodynamics and statistics quantities of the Kerr–Newman–Gödel black hole. The leading order correction is logarithmic while higher-order terms are proportional to the inverse of the area of the black hole. We obtain modified thermodynamics and statistics and find that correction terms are important in the stability of the black hole.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation and test of an automated control hunting fault correction algorithm in a fault detection and diagnostics tool

Control hunting due to improper proportional–integral–derivative (PID) parameters in the building automation system (BAS) is one of the most common faults identified in commercial buildings. It can cause suboptimal performance and early failure of heating, ventilation, and air conditioning (HVAC) equipment. Commercial fault detection and diagnostics (FDD) software represents one of the fastest growing market segments in smart building technologies in the United States. Implementation of PID retuning procedures as an auto-correction algorithm and integration into FDD software has the potential to mitigate control hunting across a heterogeneous portfolio of buildings with different BAS in a scalable way. This paper presents the development, implementation, and field testing of an automated control hunting fault correction algorithm based on lambda tuning open-loop rules. The algorithm was developed in a commercial FDD software and successfully tested among nine variable air volume boxes in an office building in the United States. The paper shows the feasibility of using FDD tools to automatically correct control hunting faults, discusses scalability considerations, and proposes a path forward for the HVAC industry and academia to further improve this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an approach to correcting MicroPEM baseline drift

Highlights: • Unacceptable baseline drift of real-time PM{sub 2.5} data measured by microPEM can lead to exposure miscalculation. • A reliable method was developed to adjust the baseline based on ambient PM{sub 2.5} levels provided by fixed monitoring sites. • It is also critical to tie the real-time data with mass-weighted average optical properties of PM{sub 2.5} collected. • This method can efficiently correct ~ 81% of the measurements with the baseline drift issue. Fine particulate matter (PM{sub 2.5}) is associated with various adverse health outcomes. The MicroPEM (RTI, NC), a miniaturized real-time portable particulate sensor with an integrated filter for collecting particles, has been widely used for personal PM{sub 2.5} exposure assessment. Five-day deployments were targeted on a total of 142 deployments (personal or residential) to obtain real-time PM{sub 2.5} levels from children living in New York City and Baltimore. Among these 142 deployments, 79 applied high-efficiency particulate air (HEPA) filters in the field at the beginning and end of each deployment to adjust the zero level of the nephelometer. However, unacceptable baseline drift was observed in a large fraction (> 40%) of acquisitions in this study even after HEPA correction. This drift issue has been observed in several other studies as well. The purpose of the present study is to develop an algorithm to correct the baseline drift in MicroPEM based on central site ambient data during inactive time periods.

54 ENVIRONMENTAL SCIENCES↗

Practical Use of the Extended No Action Level (eNAL) Correction Protocol for Breast Cancer Patients With Implanted Surgical Clips

Purpose: To describe the practical use of the extended No Action Level (eNAL) setup correction protocol for breast cancer patients with surgical clips and evaluate its impact on the setup accuracy of both tumor bed and whole breast during simultaneously integrated boost treatments. Methods and Materials: For 80 patients, two orthogonal planar kilovoltage images and one megavoltage image (for the mediolateral beam) were acquired per fraction throughout the radiotherapy course. For setup correction, the eNAL protocol was applied, based on registration of surgical clips in the lumpectomy cavity. Differences with respect to application of a No Action Level (NAL) protocol or no protocol were quantified for tumor bed and whole breast. The correlation between clip migration during the fractionated treatment and either the method of surgery or the time elapsed from last surgery was investigated. Results: The distance of the clips to their center of mass (COM), averaged over all clips and patients, was reduced by 0.9 {+-} 1.2 mm (mean {+-} 1 SD). Clip migration was similar between the group of patients starting treatment within 100 days after surgery (median, 53 days) and the group starting afterward (median, 163 days) (p = 0.20). Clip migration after conventional breast surgery (closing the breast superficially) or after lumpectomy with partial breast reconstructive techniques (sutured cavity). was not significantly different either (p = 0.22). Application of eNAL on clips resulted in residual systematic errors for the clips' COM of less than 1 mm in each direction, whereas the setup of the breast was within about 2 mm of accuracy. Conclusions: Surgical clips can be safely used for high-accuracy position verification and correction. Given compensation for time trends in the clips' COM throughout the treatment course, eNAL resulted in better setup accuracies for both tumor bed and whole breast than NAL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-level spectral deferred corrections scheme for the shallow water equations on the rotating sphere

Efficient time integration schemes are necessary to capture the complex processes involved in atmospheric flows over long periods of time. We propose a high-order, implicit–explicit numerical scheme that combines Multi-Level Spectral Deferred Corrections (MLSDC) and the Spherical Harmonics (SH) transform to solve the wave-propagation problems arising from the shallow-water equations on the rotating sphere. The iterative temporal integration is based on a sequence of corrections distributed on coupled space–time levels to perform a significant portion of the calculations on a coarse representation of the problem and hence to reduce the time-to-solution while preserving accuracy. In our scheme, referred to as MLSDC-SH, the spatial discretization plays a key role in the efficiency of MLSDC, since the SH basis allows for consistent transfer functions between space–time levels that preserve important physical properties of the solution. We study the performance of the MLSDC-SH scheme with shallow-water test cases commonly used in numerical atmospheric modeling. We use this suite of test cases, which gradually adds more complexity to the nonlinear system of governing partial differential equations, to perform a detailed analysis of the accuracy of MLSDC-SH upon refinement in time. We illustrate the stability properties of MLSDC-SH and show that the proposed scheme achieves up to eighth-order convergence in time. Finally, we study the conditions in which MLSDC-SH achieves its theoretical speedup, and we show that it can significantly reduce the computational cost compared to single-level Spectral Deferred Corrections (SDC).

97 MATHEMATICS AND COMPUTING↗

A Method for Correcting IMRT Optimizer Heterogeneity Dose Calculations

Radiation therapy treatment planning for volumes close to the patient's surface, in lung tissue and in the head and neck region, can be challenging for the planning system optimizer because of the complexity of the treatment and protected volumes, as well as striking heterogeneity corrections. Because it is often the goal of the planner to produce an isodose plan with uniform dose throughout the planning target volume (PTV), there is a need for improved planning optimization procedures for PTVs located in these anatomical regions. To illustrate such an improved procedure, we present a treatment planning case of a patient with a lung lesion located in the posterior right lung. The intensity-modulated radiation therapy (IMRT) plan generated using standard optimization procedures produced substantial dose nonuniformity across the tumor caused by the effect of lung tissue surrounding the tumor. We demonstrate a novel iterative method of dose correction performed on the initial IMRT plan to produce a more uniform dose distribution within the PTV. This optimization method corrected for the dose missing on the periphery of the PTV and reduced the maximum dose on the PTV to 106% from 120% on the representative IMRT plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement and Evaluation of Inhomogeneity Corrections and Monitor Unit Verification for Treatment Planning

Heterogeneous lung and bone phantoms have been constructed for the purpose of testing monitor unit calculations at or near interfaces for different planning systems. Data have been acquired for 2 linear accelerators: a Varian 2300cd (6 and 25 MV) and an Elekta Synergy (6, 10, and 18 MV). We have reviewed Pinnacle and the correction-based, pre-AAA version of Eclipse planning systems with the intent of exploring the limits of these systems with energy and field size. Data were acquired from 2 x 2 to 10 x 10 cm{sup 2} field sizes over the available range of energies. Our measurements confirm that Pinnacle predicts doses mostly to within {+-} 5%, even near lung-tissue interfaces over the full range of energies and field sizes tested. The Eclipse-modified Batho and equivalent TMR algorithms overpredicted doses by 10% or more in the lung and near the lung-tissue interfaces if the field size was less than 10 x 10 cm{sup 2} when the energy was 18 MV or higher. At lower energies, the field size had to be at least 6 x 6 cm{sup 2} for calculated doses to be within 10% of measurement. For bone-tissue interfaces, doses were generally underestimated by 5% to 10% or more by all calculation methods over the range of field sizes and energies reviewed. A second goal of this study was to review methods for hand-checking monitor units when heterogeneities are included. We evaluated the range of applicability of 2, one-dimensional (1D) inhomogeneity correction factors: the effective attenuation method and the TMR ratio method. The effective attenuation method for monitor unit checking was within {+-} 5% to as small as 6 x 6 cm{sup 2} fields for 6 to 10 MV, useable for 4 x 4 cm{sup 2} fields (within 7%) for 6 MV and close to {+-} 5% for 10 x 10 cm{sup 2} fields in the 18- to 25-MV range. The TMR ratio method was not as good, being within about {+-} 5% to 7% of measurements only for 6 x 6 to 10 x 10 cm{sup 2} fields at 6 MV and 10 x 10 cm{sup 2} fields at the higher energies. Both simple 1D correction methods performed almost as well as Pinnacle for the bone-soft tissue cases. We recommend that if direct measurement of dose for heterogeneous treatment plans is not practiced, then one of these simple cross checks be performed to assure patient safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of high-granularity CdZnTe pixelated detectors to correct response non-uniformities caused by defects in crystals

Following our successful demonstration of the position-sensitive virtual Frisch-grid detectors, we investigated the feasibility of using high-granularity position sensing to correct response non-uniformities caused by the crystal defects in CdZnTe (CZT) pixelated detectors. The development of high-granularity detectors able to correct response non-uniformities on a scale comparable to the size of electron clouds opens the opportunity of using unselected off-the-shelf CZT material, whilst still assuring high spectral resolution for the majority of the detectors fabricated from an ingot. Here, we present the results from testing 3D position-sensitive 15×15×10 mm 3 pixelated detectors, fabricated with conventional pixel patterns with progressively smaller pixel sizes: 1.4, 0.8, and 0.5 mm. We employed the readout system based on the H3D front-end multi-channel ASIC developed by BNL's Instrumentation Division in collaboration with the University of Michigan. We use the sharing of electron clouds among several adjacent pixels to measure locations of interaction points with sub-pixel resolution. By using the detectors with small-pixel sizes and a high probability of the charge-sharing events, we were able to improve their spectral resolutions in comparison to the baseline levels, measured for the 1.4-mm pixel size detectors with small fractions of charge-sharing events. These results demonstrate that further enhancement of the performance of CZT pixelated detectors and reduction of costs are possible by using high spatial-resolution position information of interaction points to correct the small-scale response non-uniformities caused by crystal defects present in most devices.

36 MATERIALS SCIENCE↗

malbacR: A Package for Standardized Implementation of Batch Correction Methods for Omics Data

Mass spectrometry is a powerful tool for identifying and analyzing small molecules, such as metabolites and lipids, in com-plex biological samples. Liquid chromatography and gas chromatography mass spectrometry studies quite commonly in-volve large numbers of samples, which can require significant time for sample preparation and analyses. To accommodate such studies, the samples are commonly split into batches. Inevitably, variations in sample handling, temperature fluctua-tion, imprecise timing, column degradation and other factors result in systematic errors or biases of the measured abundances between the batches. Numerous methods are available via R packages to assist with batch correction for small molecule om-ics data; however, since these methods were developed by different research teams, the algorithms are available in separate R packages, each with different data input and output formats. We introduce the malbacR package which consolidates eleven common batch effect correction methods for small molecule omics data into one place so users can easily implement and compare: pareto scaling, power scaling, range scaling, ComBat, EigenMS, NOMIS, RUV-random, QC-RLSC, WaveI-CA2.0, TIGER, and SERRF. The malbacR package standardizes data input and output formats across these batch correction methods. The package works in conjunction with the pmartR package, allowing users to seamlessly include batch effect cor-rection in a pmartR workflow without needing any additional data manipulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multivariate Drought Monitoring, Propagation, and Projection Using Bias-Corrected General Circulation Models

Understanding how droughts are characterized, propagated, and projected, particularly multivariate droughts, is necessary to explain the variability and changes in drought characteristics. This study aims to understand multimodel global drought monitoring, propagation, and projection by utilizing a multivariate standardized drought index (MSDI) during the historical (1959–2014) and future (2045–2100) periods under two socioeconomic pathways SSPs (370 and 585), derived from the bias-corrected Coupled Model Intercomparison Project Phase 6 (CMIP6). Based on the energy metrics, the multivariate bias correction method outperformed other techniques in correcting the biases in the CMIP6 drought representation. The drought indicators demonstrate distinct categories for meteorological, hydrological, and multivariate droughts. There were significant high cross correlations between Heatwave Total Length (HWTL) and MSDI in Africa and South America for all lagged times. Europe and North America generally saw the maximum MSDI drought duration (228 months) during the historical period. For future projections, Africa recorded the maximum drought duration (197 months), while Europe witnessed the minimum drought duration for SSP 370 (171 months), and North America (149 months) for SSP 585. Furthermore, during the historical period in tropical Africa, the propagation of meteorological to hydrological drought was slower during the wet months than during the dry months. Under the SSP 370 future projection, there was a shift in the long period of meteorological-hydrological propagation from the middle and late wet months to the beginning of the wet months in tropical Africa. Therefore, tracking and projecting drought characteristics is vital for understanding the risk of drought-related consequences.

54 ENVIRONMENTAL SCIENCES↗

A Machine Learning Bias Correction on Large–Scale Environment of High–Impact Weather Systems in E3SM Atmosphere Model

Large–scale dynamical and thermodynamical processes are common environmental drivers of high–impact weather systems causing extreme weather events. However, such large–scale environmental conditions often display systematic biases in climate simulations, posing challenges to evaluating high–impact weather systems and extreme weather events. In this paper, a machine learning (ML) approach was employed to bias correct the large–scale wind, temperature, and humidity simulated by the atmospheric component of the Energy Exascale Earth System Model (E3SM) at ~1° resolution. The usefulness of the ML approach for extreme weather analysis was demonstrated with a focus on three high–impact weather systems, including tropical cyclones (TCs), extratropical cyclones (ETCs), and atmospheric rivers (ARs). We show that the ML model can effectively reduce climate bias in large–scale wind, temperature, and humidity while preserving their responses to imposed climate change perturbations. The bias correction is found to directly improve water vapor transport associated with ARs, and representations of thermodynamical flows associated with ETCs. When the bias–corrected large–scale winds are used to drive a synthetic TC track forecast model over the Atlantic basin, the resulting TC track density agrees better with that of the TC track model driven by observed winds. In addition, the ML model insignificantly interferes with the mean climate change signals of large–scale storm environments as well as the occurrence and intensity of three weather systems. This study suggests that the proposed ML approach can be used to improve the downscaling of extreme weather events by providing more realistic large–scale storm environments simulated by low–resolution climate models.

54 ENVIRONMENTAL SCIENCES↗

Imaging Single Atoms Using Secondary Electrons with an Aberration-Corrected Electron Microscope

Aberration correction has embarked on a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes. However, improvement of spatial resolution using aberration correction so far has been limited to the use of transmitted electrons both in scanning and stationary mode, with an improvement of 20-40%. In contrast, advances in the spatial resolution of scanning electron microscopes (SEMs), which are by far the most widely used instrument for surface imaging at the micrometre-nanometre scale, have been stagnant, despite several recent efforts. Here, we report a new SEM, with aberration correction, able to image single atoms by detecting electrons emerging from its surface as a result of interaction with the small probe. The spatial resolution achieved represents a fourfold improvement over the best-reported resolution in any SEM. Furthermore, we can simultaneously probe the sample through its entire thickness with transmitted electrons. This ability is significant because it permits the selective visualization of bulk atoms and surface ones, beyond a traditional two-dimensional projection in transmission electron microscopy. It has the potential to revolutionize the field of microscopy and imaging, thereby opening the door to a wide range of applications, especially when combined with simultaneous nanoprobe spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunneling dynamics with a mixed quantum-classical method: Quantum corrected propagator combined with frozen Gaussian wave packets

The recently developed mixed quantum-classical propagation method is extended to treat tunneling effects in multidimensional systems. Formulated for systems consisting of a quantum primary part and a classical bath of heavier particles, the method employs a frozen Gaussian description for the bath degrees of freedom, while the dynamics of the quantum subsystem is governed by a corrected propagator. The corrections are defined in terms of matrix elements of zeroth-order propagators. The method is applied to a model system of a double-well potential bilinearly coupled to a harmonic oscillator. The extension of the method, which includes nondiagonal elements of the correction propagator, enables an accurate treatment of tunneling in an antisymmetric double-well potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superconducting switch concept applied to superconducting undulator phase-error correction

Superconducting undulator (SCU) technology has the potential to significantly enhance the performance of synchrotron radiation sources for storage ring and FEL applications. Since 2002, our team at Lawrence Berkeley National Laboratory has been performing R and D on superconducting undulators, including the fabrication of three Nb{sub 3}Sn prototypes. We have demonstrated experimentally the possibility to provide the prototype with trim coils that could be used for phase error correction. The research effort that we report here demonstrates the possibility to add degrees of freedom to the field correction provided by these coils in a cryogenic environment. By means of bridge of superconducting switches, we can modify the current direction through a trim coil. Here we describe the design of the experimental bridge we fabricated, the results we obtained and finally the generalized concept one could plan to apply to correct the phase errors with trim coils connected to a network of superconducting bridges.

43 PARTICLE ACCELERATORS↗

A semiclassical correction for quantum mechanical energy levels

We propose a semiclassical method for correcting molecular energy levels obtained from a quantum mechanical variational calculation. A variational calculation gives the energy level (i.e., eigenvalue) as the expectation value of the molecular Hamiltonian <{phi}|H|{phi}>, where |{phi}> is the trial wave function. The true (i.e., exact) eigenvalue E can thus be expressed as this variational result plus a correction, i.e., E=<{phi}|H|{phi}>+{Delta}E, the correction being due to the lack of exactness of the trial wave function. A formally exact expression for {Delta}E is usually given (via Loewdin partitioning methodology) in terms of the Greens function of the Hamiltonian projected onto the orthogonal complement of |{phi}>. Formal treatment of this expression (using Brillouin-Wigner perturbation theory to infinite order) leads to an expression for {Delta}E that involves matrix elements of the Greens function for the unprojected, i.e., full molecular Hamiltonian, which can then be approximated semiclassically. (Specifically, the Greens function is expressed as the Fourier transform of the quantum mechanical time evolution operator, e{sup -}iHt/({h_bar}/2{pi}), which in turn is approximated by using an initial value representation of semiclassical theory.) Calculations for several test problems (a one dimensional quartic potential, and vibrational energy levels of H{sub 2}O and H{sub 2}CO) clearly support our proposition that the error in the total eigenvalue E arises solely due to the semiclassical error in approximating {Delta}E, which is usually a small fraction of the total energy E itself.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conduction band offset at GeO{sub 2}/Ge interface determined by internal photoemission and charge-corrected x-ray photoelectron spectroscopies

We report a consistent conduction band offset (CBO) at a GeO{sub 2}/Ge interface determined by internal photoemission spectroscopy (IPE) and charge-corrected X-ray photoelectron spectroscopy (XPS). IPE results showed that the CBO value was larger than 1.5 eV irrespective of metal electrode and substrate type variance, while an accurate determination of valence band offset (VBO) by XPS requires a careful correction of differential charging phenomena. The VBO value was determined to be 3.60 {+-} 0.2 eV by XPS after charge correction, thus yielding a CBO (1.60 {+-} 0.2 eV) in excellent agreement with the IPE results. Such a large CBO (>1.5 eV) confirmed here is promising in terms of using GeO{sub 2} as a potential passivation layer for future Ge-based scaled CMOS devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗