Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,060 records · Page 59

Moving beyond 90% Carbon Capture by Highly Selective Membrane Processes

A membrane-based system with a retentate recycle process in tandem with an enriching cascade was studied for >90% carbon capture from coal flue gas. A highly CO 2 -selective facilitated transport membrane (FTM) was utilized particularly to enhance the CO 2 separation efficiency from the CO 2 -lean gases for a high capture degree. A techno-economic analysis showed that the retentate recycle process was advantageous for ≤90% capture owing to the reduced parasitic energy consumption and membrane area. At >90% capture, the enriching cascade outperformed the retentate recycle process since a higher feed-to-permeate pressure ratio could be applied. An overall 99% capture degree could be achieved by combining the two processes, which yielded a low capture cost of USD47.2/tonne, whereas that would be USD 42.0/tonne for 90% capture. This FTM-based approach for deep carbon capture and storage can direct air capture for the mitigation of carbon emissions in the energy sector.

42 ENGINEERING↗

Improvement of General Electric’s Chilled Ammonia Process with the use of Membrane Technology

General Electric Environmental Control Solutions (formerly Alstom Power Environmental Control Systems) set out to complete the Phase 1 award requirements for a Phase II renewal application for their project selected under DOE-FOA-0001190 “Small and Large Scale Pilots for Reducing the Cost of CO 2 Capture and Compression”. The project focus was to implement several improvement concepts utilizing membrane technology at the recipient’s Chilled Ammonia Process (CAP) CO 2 capture large-scale pilot plant. The goal was to lower the overall cost of technology. During the development of costs for the preliminary techno-economic assessment (TEA), it became clear that the capital and operating costs of this concept were not economically attractive. All work related to a Phase II renewal application at that point was halted as GE made the decision not to submit a Phase II renewal application. Discussions with DOE resulted in a path towards useful information produced from the design and cost work already completed on the project. With the reverse osmosis (RO) unit providing most of the cost issues, GE would provide a sensitivity analysis of the RO unit with respect to project cost. This information would be included with the Techno-Economic Analysis along with the Technology Gap Analysis.

20 FOSSIL-FUELED POWER PLANTS↗

Carbon balance of CO2-EOR for NCNO classification

The question of whether carbon dioxide enhanced oil recovery (CO2-EOR) constitutes a valid alternative for greenhouse gas emission reduction has been frequently asked by the general public and environmental sectors. Through this technology, operational since 1972, oil production is enhanced by injecting CO2 into depleted oil reservoirs in order displace the residual oil toward production wells in a solvent/miscible process. For decades, the CO2 utilized for EOR has been most commonly sourced from natural CO2 accumulations. More recently, a few projects have emerged where anthropogenic CO2 (A-CO2) is captured at an industrial facility, transported to a depleted oil field, and utilized for EOR. If carbon geologic storage is one of the project objectives, all the CO2 injected into the oil field for EOR could technically be stored in the formation. Even though the CO2 is being prevented from entering the atmosphere, and permanently stored away in a secured geologic formation, a question arises as to whether the total CO2 volumes stored in order to produce the incremental oil through EOR are larger than the CO2 emitted throughout the entire CO2-EOR process, including the capture facility, the EOR site, and the refining and burning of the end product. We intend to answer some of these questions through a DOE-NETL funded study titled “Carbon Life Cycle Analysis of CO2-EOR for Net Carbon Negative Oil (NCNO) Classification”. NCNO is defined as oil whose carbon emissions to the atmosphere, when burned or otherwise used, are less than the amount of carbon permanently stored in the reservoir in order to produce the oil. In this paper, we focus on the EOR site in what is referred to as a gate-to-gate system, but are inclusive of the burning of the refined product, as this end member is explicitly stated in the definition of NCNO. Finally, we use Cranfield, Mississippi, as a case study and come to the conclusion that the incremental oil produced is net carbon negative.

54 ENVIRONMENTAL SCIENCES↗

Data Gap Assessment Subtask 4.1 Topical Report

Data sets were compiled and assessed for the Cambro-Ordovician Storage Complex across the CarbonSAFE Illinois East Sub-Basin study area to assess the data needs to support drilling a stratigraphic borehole at the East Sub-Basin case study site located at the Wabash Integrated Gasification Combined Cycle (IGCC) plant north of Terre Haute, Indiana. Available data for the Mt. Simon Sandstone, within a 50 mile range in the East Sub-Basin study area, was assembled and cataloged. A summary of regional data documenting seal penetrations in the Cambrian Eau Claire and Ordovician Maquoketa was compiled, but a lack of deep well control over the project area illustrates the need for test boring and data acquisition at the East Sub-Basin case study site.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of Cryogenic Systems for Post Combustion CO2 Capture

Cryogenic capture of carbon dioxide from flue gas streams is one potential pathway to reduce the CO2 emissions from power plants and industrial sources. In this paper, a minimum energy analysis of idealized cryogenic carbon capture processes is performed. Parametric studies on this idealized process are quantified to study the effect of minimum capture temperature and simulated heat exchange approach temperatures. The theoretical and practical difficulties in approaching this ideal process are described and discussed. Finally, the Sustainable Energy Solutions External Cooling Loop Cryogenic Carbon Capture™ process is evaluated and compared to the idealized carbon-capture process.

20 FOSSIL-FUELED POWER PLANTS↗

Assessment of Multiple Monitoring Methods for Detection of Brine and CO2 Leakage

We assess the effectiveness of four surface-based geophysical methods and in situ monitoring of pressure and chemical changes for detecting brine and CO2 leakage from legacy wells into underground sources of drinking water (USDW) overlying a CO2 storage reservoir. This is the first such effort to evaluate and compare six monitoring methods for detection of CO2 leakage. This assessment, conducted in support of the USDOE National Risk Assessment Partnership (NRAP), utilizes 3000 synthetic data sets, generated in an uncertainty quantification (UQ) model framework. This framework combines the results of (1) a CO2 storage reservoir model of a hypothetical storage operation of 5 MT/yr for 50 years into the 1700-m deep Vedder Fm. at a site near Kimberlina, California with (2) wellbore leakage models of a legacy well and (3) multi-phase flow and reactive transport models of brine and CO2 plume migration in aquifer layers overlying the storage reservoir. Leakage drives subsurface changes, quantified by pressure plumes, CO2-saturation plumes, and total dissolved solids (TDS) plumes, the latter being related to changes in pH and species concentrations. Depending on the depth of leakage, aquifer permeability, and regional groundwater gradient, pressure plume volumes can become larger than the CO2 and TDS plumes; however, reaching detectable thresholds may take too long to be useful. For a single monitoring well located 500 m downgradient of a leaky legacy well, a depth of 570 m is found to be optimal for sampling pressure and chemical changes. We assess four surface-based geophysical monitoring methods: electrical resistivity tomography (ERT), magnetotellurics (MT), gravity, and seismic methods. Sensors cover a 4-km × 2-km area. Both ERT and MT methods are sensitive to changes in CO2 saturation and TDS concentration, whereas gravity and seismic methods detect changes in CO2 saturation. The six monitoring methods complement each other in space and time, and we find that a minimum of 20 kT of CO2 leakage is required for the leakage plume to be detected. Of the four surface-based geophysical methods, gravity monitoring appears to be the most sensitive to CO2 leaks, while the usefulness of in situ pressure and chemical monitoring will depend on the level of unfilterable background noise. Geophysical monitoring methods may detect a leak anywhere in a large area and in a large depth range, but the effectiveness of pressure and chemical monitoring depends on the number of monitoring wells, where those wells are located, and the depth of sampling. Surface-based geophysical monitoring methods are cost-effective alternatives to in situ pressure and chemical monitoring methods.

NRAP, CCS, monitoring, geophysical methods, gravit↗

Annual Technology Baseline: The 2023 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation and storage technologies: land-based wind, offshore wind, distributed wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, commercial battery storage, residential battery storage, pumped storage hydropower, coal, and natural gas. EIA data for nuclear and conventional biopower are included for reference. This webinar presentation introduces the 2023 update to the ATB Electricity data and documentation.

capacity factor↗

Annual Technology Baseline: The 2024 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation and storage technologies: land-based wind, offshore wind, distributed wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, commercial battery storage, residential battery storage, pumped storage hydropower, nuclear, coal, and natural gas. EIA data for conventional biopower are included for reference. This webinar presentation introduces the 2024 update to the ATB Electricity data and documentation.

battery storage↗

Exploring the Feasibility of a Carbon Dioxide Storage Hub in Western North Dakota

The University of North Dakota Energy & Environmental Research Center (EERC) and project partner ONEOK, Inc. (ONEOK) are investigating the feasibility of establishing a CO2 (carbon dioxide) storage hub in western North Dakota—in the heart of the Williston Basin. The conceived Roughrider Carbon Storage Hub would store CO2 captured from six gas-processing plants owned and operated by project partner ONEOK and a planned gas-to-liquids plant. This 2-year U.S. Department of Energy-sponsored Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Phase II feasibility study is evaluating the aggregation of the CO2 captured from these seven sources for injection into stacked geologic storage complexes. The proposed hub includes several aspects that make it a highly qualified candidate for a feasibility study with a notably reduced project risk profile. These include 1) a project partner (ONEOK) with a committed goal to reduce greenhouse gas emissions; 2) prior subsurface data analysis supporting a potential stacked storage configuration with adequate CO2 storage resource; 3) commitment from local, regional, and state-level stakeholders; and 4) a state with U.S. Environmental Protection Agency underground injection control Class VI primacy. ONEOK’s assets in the Williston Basin provide significant environmental benefits by capturing and processing natural gas that may otherwise be flared or vented. Storing CO2 from these gas-processing facilities will reduce overall CO2 emissions in the basin while providing essential services to producers there and contributing to continued energy independence in the domestic markets.

03 NATURAL GAS↗

Tensor renormalization group approach to the $O(2)$ models via symmetry-twisted partition functions

We investigate critical phenomena in the $O(2)$ models using symmetry-twisted partition functions that can be efficiently computed within the tensor renormalization group framework. We first demonstrate, taking the three-dimensional model as an example, that symmetry-twisted partition functions detect the spontaneous breaking of global continuous symmetry. We then consider the same model in two dimensions, where the Berezinskii--Kosterlitz--Thouless (BKT) transition occurs. Since symmetry-twisted partition functions directly provide the helicity modulus at a finite twist angle, we determine the BKT transition point. These results are presented based on Ref.~\cite{Akiyama:2026dzg}. Finally, in addition to the original paper~\cite{Akiyama:2026dzg}, we apply this approach to the two-dimensional generalized $O(2)$ model and confirm that it successfully identifies the phase transitions between the ferromagnetic and nematic phases, as well as between the nematic and paramagnetic phases.

Akiyama, Shinichiro [Tsukuba U., CCS; Tokyo U., IC↗