At least 1,063 records · Page 59

Soil Moisture Active/Passive (SMAP) L-band Microwave Radiometer Post-Launch Calibration Revisit: Approach and Performance

The SMAP microwave radiometer is a fully-polarimetric L-band radiometer flown on the SMAP satellite in a 6 AM / 6 PM sun-synchronous orbit at 685-km altitude. After the SMAP L1B_TB data product version4was released in 2018, the radiometer has undergonefurther calibration and validation. The goal isto reducethe difference between antenna temperature (TA) ofascending and descending orbits during the eclipse, andto reduce the dips in the calibration drift over the Cold Sky (CS) during the eclipse seasons in 2017 and 2018. The post-launch calibration algorithmhas been revisitedby retrieving all of the calibration parameters simultaneouslywith two different options for thehot calibration source(theglobal ocean, or the radiometer internal reference load). The performance of the two options are compared here. Theoption with the radiometer internal reference load has been chosen by the SMAP science team for data release version 5. In addition, a correction offset is applied to the input signal to account for offsets during the early-mission stages with theSMAP SAR transmitter operating alongside the radiometer.

Jinzheng Peng↗

Automated Noise Calibration System (VT-1000)

This paper details an automated Noise Source calibration system in development at Jet Propulsion Laboratory, California Institute of Technology (JPL). The paper begins with a discussion on Noise Figure and Excess Noise Ratio (ENR) theory, fundamentals and governing equations. As part of the fundamentals is a discussion of the system’s use of the Y-factor method to obtain accurate measurements of the Unit Under Test (UUT), and how these measurements are compared against a known ENR standard to obtain the UUT’s ENR values. There is also an in-depth discussion on uncertainty quantification for Noise Source system calibrations. The architecture of the automated calibration system is provided, which includes both the system’s hardware and software configuration. The software is written in Python 3, and provides the user detailed instruction on how to proceed, including step-by-step connection requirements. This system automates much of the measurement process, including real-time uncertainty quantification and report generation, as well as real-time feedback to the user to allow intervention if necessary. The system takes advantage of a database of results from previous measurements to compare calibration history of the ENR measurements. The automated system presented here operates over a frequency range from 10 MHz to 50 GHz, and has shown substantial time savings over traditional manual methods of performing this calibration.

Timpe, Scott↗

Polarimetric calibration of the Multi-Angle Imager for Aerosols (MAIA)

NASA’s Multi-Angle Imager for Aerosols (MAIA) mission, under development at the Jet Propulsion Laboratory, is designed to study the adverse health effects of different types of particulate air pollution. Planned for launch in 2023 for a 3-year mission, the MAIA satellite instrument will focus on a selected set of metropolitan target areas, where air quality monitors and health data are available. Aerosol concentration and speciation are inferred from multi-angle measurements of backscattered sunlight in 14 spectral bands from 350-2200 nm, with bands near 442, 645 and 1040 nm measuring the degree (DoLP) and angle of linear polarization (AoLP) in addition to radiance. The pushbroom camera has a ~240-km cross-track field of view with a nadir resolution of ~200 m, and is mounted onto a biaxial gimbal to provide along-track view angles within ±60°, to extend the field of regard to ±48°, and to view the instrument’s onboard calibrator (OBC) and dark target. The OBC consists of a sunlit transmissive diffuser, followed by 12 polarizers at different orientations. MAIA’s polarimetry is implemented using miniature wire grid polarizers on the focal plane array, and dual photoelastic modulators (PEMs) and achromatic quarter-wave plates to rapidly rotate the polarization. The resulting ~26-Hz intensity modulation encodes the linearly polarized and total radiance in each pixel, leaving the DoLP and AoLP insensitive to gain calibration. We report on the polarimetric calibration of the MAIA camera using a vacuum-compatible polarization state generator, consisting of a 1600W Xenon lamp, 12-inch integrating sphere, and rotating high-extinction polarizer. Mueller-matrix-based calibration coefficients for each detector pixel are derived from measurements at multiple polarizer angles, and are used to correct the measurements for instrumental polarization aberrations. Prior to flight, the calibrated MAIA camera is panned across the OBC to characterize its output, using uniform illumination with an irradiance similar to the Sun.

Werne, Thomas↗

The Impact of Pixel Size on the Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides the scientific community the observed TOA SW and LW fluxes for climate monitoring and climate model validation. CERES utilizes hourly geostationary imager derived broadband fluxes, which rely on the channel radiances and associated cloud retrievals, to estimate the broadband fluxes between CERES observations. This requires stable imager visible channel calibration, which the CERES project verifies by utilizing deep convective clouds (DCC) as an invariant Earth target. GSICS, which is an international collaboration, is also evaluating the DCC invariant target calibration methodology to provide consistent calibration coefficients across geostationary imagers anchored to the Aqua-MODIS calibration reference. Tropical DCC are the brightest, coldest, most Lambertian, top of the atmosphere Earth targets. The DCC invariant target calibration methodology relies on a large ensemble of tropical DCC-identified pixel-level reflectances, which are histogrammed to find the mode reflectance of the probability density function (PDF). The imager stability is monitored by tracking the monthly DCC PDF mode reflectance over time. Radiometric scaling is accomplished by ratioing the GEO and VIIRS DCC mode reflectance values. The PDF shape and mode dependency on sensor pixel resolution, which varies among sensors, is unknown. This study will characterize the impact of pixel resolution on the DCC PDFs by aggregating Landsat 30-m pixel reflectances into various coarser pixel resolutions ranging from 100-m to 4-km, and comparing the corresponding PDF statistics. This analysis will assist in improving the uncertainty in a DCC-based intercalibration between instruments with different pixel resolutions.

Conor Haney↗

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗

Energy Performance Assessment of Radiant Cooling System through Modeling and Calibration at Component Level

The paper describes a case study of an information technology office building with a radiant cooling system and a conventional variable air volume (VAV) system installed side by side so that performancecan be compared. First, a 3D model of the building involving architecture, occupancy, and HVAC operation was developed in EnergyPlus, a simulation tool. Second, a different calibration methodology was applied to develop the base case for assessing the energy saving potential. This paper details the calibration of the whole building energy model to the component level, including lighting, equipment, and HVAC components such as chillers, pumps, cooling towers, fans, etc. Also a new methodology for the systematic selection of influence parameter has been developed for the calibration of a simulated model which requires large time for the execution. The error at the whole building level [measured in mean bias error (MBE)] is 0.2%, and the coefficient of variation of root mean square error (CvRMSE) is 3.2%. The total errors in HVAC at the hourly are MBE = 8.7% and CvRMSE = 23.9%, which meet the criteria of ASHRAE 14 (2002) for hourly calibration. Different suggestions have been pointed out to generalize the energy saving of radiant cooling system through the existing building system. So a base case model was developed by using the calibrated model for quantifying the energy saving potential of the radiant cooling system. It was found that a base case radiant cooling system integrated with DOAS can save 28% energy compared with the conventional VAV system.

Building Energy Simulation↗

Automated calibration of multistatic arrays

A method is disclosed for calibrating a multistatic array having a plurality of transmitter and receiver pairs spaced from one another along a predetermined path and relative to a plurality of bin locations, and further being spaced at a fixed distance from a stationary calibration implement. A clock reference pulse may be generated, and each of the transmitters and receivers of each said transmitter/receiver pair turned on at a monotonically increasing time delay interval relative to the clock reference pulse. Ones of the transmitters and receivers may be used such that a previously calibrated transmitter or receiver of a given one of the transmitter/receiver pairs is paired with a subsequently un-calibrated one of the transmitters or receivers of an immediately subsequently positioned transmitter/receiver pair, to calibrate the transmitter or receiver of the immediately subsequent transmitter/receiver pair.

42 ENGINEERING↗

Experiments and numerical modeling of surrogate droplet combustion for a 93 octane gasoline calibration fuel

Gasoline is the world’s most prolific liquid transportation fuel for ground transportation vehicles. Yet, a fundamental understanding of its burning characteristics is still lacking. Complicating this matter is the highly multicomponent nature of gasoline (comprised of hundreds of chemical species) and the seasonable variability of its composition due to variations in the crude oil feedstocks used in refining. The need to bring order to this complex problem has led to development of calibration fuels (Tier II in presented study) which on average will provide repeatable metrics that replicate performance of refined gasoline for various engine designs. This study presents results of experiments using the configuration of an isolated droplet to study the combustion dynamics of calibration fuel and three different surrogates (S4, S5, S6) for the calibration fuel. Droplet burning is under microgravity conditions, where gas transport is determined entirely by fuel evaporation in order to promote spherical symmetry in the burning process. The initial droplet diameters ranged between 0.55 mm and 0.60 mm. The droplets were spark-ignited and their burning histories were recorded by digital video cameras to obtain quantitative data. For each fuel, the evolutions of droplet, flame, and soot-shell diameters were measured to calculate the burn rates, flame-droplet diameter ratios (FSR) and soot-droplet diameter ratios. Additionally, a detailed numerical modeling is presented. This simulation includes multicomponent phase equilibrium, unsteady gas and liquid transport, radiative heat transfer, internal liquid diffusion and detailed combustion chemistry of different fuels during their burning process. Experiment results show that the calibration fuel and surrogates have a close burn rates and FSR, and S5 presents a relatively similar results with calibration fuel. Predictions from the numerical simulation using the surrogate are compared with experiment measurements, which showed a good agreement with the experiment results, including the droplet burning rate and FSR.

Guo, Songtao↗

Trial-based calibration for audio-based identification, recognition, and detection system

The disclosed technologies include methods for generating a calibration model using data that is selected to match the conditions of a particular trial that involves an automated comparison of data samples, such as a comparison-based trial performed by an audio-based recognition, identification, or detection system. The disclosed technologies also include improved methods for selecting candidate data used to build the calibration model. The disclosed technologies further include methods for evaluating the performance of the calibration model and for rejecting a trial when not enough matched candidate data is available to build the calibration model. The disclosed technologies additionally include the use of regularization and automated data generation techniques to further improve the robustness of the calibration model.

McLaren, Mitchell Leigh↗

Bayesian optimization for inverse calibration of expensive computer models: A case study for Johnson-Cook model in machining

Inverse model calibration for identifying the constitutive model parameters can be computationally demanding for expensive-to-evaluate simulation models. Here, this paper presents a modified Bayesian optimization (BO) method, denoted as BO-bound, that incorporates theoretical bounds on the quantity of interest. A case study for the inverse calibration of the Johnson Cook (J-C) flow stress model parameters is presented using machining (cutting) force data. The results show fast calibration of the five J-C parameters within 25 simulations. In general, the BO-bound method is applicable for inverse calibration of any expensive simulation models as well as optimization problems with known bounds.

Bayesian optimization↗

Test-Based Calibration of Safety Factors for Capacity Models

In this paper, a simple procedure to calibrate the safety factor of capacity models is presented. The calibration can be carried out based on any available database of experimental tests, even of limited size. The procedure aims to assess the model capability of predicting the test results and to calibrate the safety factor so that the capacity equation meets the target reliability level required by the code or sought by the calibrator. After predicting each test of the database with the capacity equation under consideration, the test-prediction pairs are checked for the property of linearity, and the relative error for the properties of homoscedasticity and normality. Once these properties are fulfilled—which may require a nonlinear transformation of the test values and/or the predictions—the closed-form equation proposed in this paper is employed to compute a target design value. The model safety factor is finally obtained by comparing such target design value with the design value obtained from the code. The paper also proposes two approximate analytical equations to compute the tolerance factor, used to attain any given fractile, as a function of the (even small) number of tests, with any assigned confidence level. A fundamental outcome of the procedure is that it yields an objective indicator of the model accuracy, measured by the standard deviation of its error, which may be regarded as a parameter useful for selecting the most reliable model among different competing ones. In the long run, the application of the proposed procedure will allow achieving a uniform reliability level throughout all capacity models used in codes and guidelines. A further advantage is that the partial safety factors so derived can be straightforwardly updated when more experiments become available. Finally, as an example, the proposed procedure is herein applied to the ACI 318 shear design capacity equation for concrete members unreinforced in shear.

42 ENGINEERING↗

On-Orbit Calibration of a Multi-Spectral Satellite Satellite Sensor Using a High Altitude Airborne Imaging Spectrometer

Earth-looking satellites must be calibrated in order to quantitatively measure and monitor components of land, water and atmosphere of the Earth system. The inevitable change in performance due to the stress of satellite launch requires that the calibration of a satellite sensor be established and validated on-orbit. A new approach to on-orbit satellite sensor calibration has been developed using the flight of a high altitude calibrated airborne imaging spectrometer below a multi-spectral satellite sensor.

sensor calibration calibration Earth-looking satel↗

MODIS and VIIRS Calibration and Characterization in Support of Producing Long-Term High-Quality Data Products

Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated since their launches in 1999 and 2002, respectively, and generated various data products to support the Earth remote sensing disciplines and users worldwide for their research activities and applications, including studies of the Earth system, and its changes over time and geographic regions. The MODIS data have also significantly contributed to the continuity of multi-decadal satellite data records and led to major advances in the Earth remote sensing field. The long-term data records from MODIS observations have been and will continue to be extended by the Visible Infrared Imaging Radiometer Suite (VIIRS) instruments, currently operated aboard the Suomi-National Polar-Orbiting Partnership (NPP) and NOAA-20 satellites. The data quality of satellite instruments strongly depends on their calibration accuracy and stability. In order to help scientists and users gain a better understanding of MODIS and VIIRS data quality, this paper provides an overview of their on-orbit calibration methodologies, approaches, and results derived from instrument on-board calibrators and lunar observations, as well as select Earth view targets. What is also discussed is the calibration consistency between MODIS and VIIRS and its potential impact on producing multi-sensor long-term data records. As illustrated, the overall performance of both MODIS and VIIRS continues to meet their design requirements.

MODIS↗

Quantifying model structural error: Efficient Bayesian calibration of a regional groundwater flow model using surrogates and a data-driven error model

Groundwater model structural error is ubiquitous, due to simplification and/or misrepresentation of real aquifer systems. During model calibration, the basic hydrogeological parameters may be adjusted to compensate for structural error. This may result in biased predictions when such calibrated models are used to forecast aquifer responses to new forcing. Here, we investigate the impact of model structural error on calibration and prediction of a real-world groundwater flow model, using a Bayesian method with a data-driven error model to explicitly account for model structural error. The error-explicit Bayesian method jointly infers model parameters and structural error and thereby reduces parameter compensation. In this study, Bayesian inference is facilitated using high performance computing and fast surrogate models (based on machine learning techniques) as a substitute for the computationally expensive groundwater model. We demonstrate that with explicit treatment of model structural error, the Bayesian method yields parameter posterior distributions that are substantially different from those derived using classical Bayesian calibration that does not account for model structural error. We also found that the error-explicit Bayesian method gives signficantly more accurate prediction along with reasonable credible intervals. Finally, through variance decomposition, we provide a comprehensive assessment of prediction uncertainty contributed from parameter, model structure, and measurement uncertainty. The results suggest that the error-explicit Bayesian approach provides a solution to real-world modeling applications for which data support the presence of model structural error, yet model deficiency cannot be specifically identified or corrected.

54 ENVIRONMENTAL SCIENCES↗

Flood hazard model calibration using multiresolution model output

Riverine floods pose a considerable risk to many communities. Improving flood hazard projections has the potential to inform the design and implementation of flood risk management strategies. Current flood hazard projections are uncertain, especially due to uncertain model parameters. Calibration methods use observations to quantify model parameter uncertainty. With limited computational resources, researchers typically calibrate models using either relatively few expensive model runs at high spatial resolutions or many cheaper runs at lower spatial resolutions. This leads to an open question: is it possible to effectively combine information from the high and low resolution model runs? We propose a Bayesian emulation–calibration approach that assimilates model outputs and observations at multiple resolutions. As a case study for a riverine community in Pennsylvania, we demonstrate our approach using the LISFLOOD-FP flood hazard model. Here, the multiresolution approach results in improved parameter inference over the single resolution approach in multiple scenarios. Results vary based on the parameter values and the number of available models runs. Our method is general and can be used to calibrate other high dimensional computer models to improve projections.

multiresolution↗

Calibration and uncertainty quantification for Davis Equation of State models for the High Explosive PBX 9501 products

Abstract This paper investigates the uncertainty in the parameters used in the calibration of an Davis Equation Of State (EOS) for the detonation products of the High Explosive PBX 9501. The procedure sought to make use of all available information about this HE to inform the best set of calibration parameters as well as the uncertainty in these parameters. The procedure made use of historical experimental data, the results from thermo‐chemical modeling as well as data on the best isentrope function fit to cylinder test experimental data. Combining all these heterogeneous data sources together in a Bayesian calibration, yielded a posterior mean and covariance. Sampling from the posterior distribution and evaluating an important Quantity Of Interest (QOI) in the EOS model, the detonation speed of a one‐inch rate stick, produced a distribution which showed variations which were in agreement with experiments. The uncertainty in the EOS was reported as eleven sets of model calibrations which spanned the range of this QOI.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A comparison of Gaussian processes and neural networks for computer model emulation and calibration

The Department of Energy relies on complex physics simulations for prediction in domains like cosmology, nuclear theory, and materials science. These simulations are often extremely computationally intensive, with some requiring days or weeks for a single simulation. In order to assure their accuracy, these models are calibrated against observational data in order to estimate inputs and systematic biases. Because of their great computational complexity, this process typically requires the construction of an emulator, a fast approximation to the simulation. In this paper, two emulator approaches are compared: Gaussian process regression and neural networks. Their emulation accuracy and calibration performance on three real problems of Department of Energy interest is considered. On these problems, the Gaussian process emulator tends to be more accurate with narrower, but still well-calibrated uncertainty estimates. The neural network emulator is accurate, but tends to have large uncertainty on its predictions. Finally, as a result, calibration with the Gaussian process emulator produces more constrained posteriors that still perform well in prediction.

97 MATHEMATICS AND COMPUTING↗

Broadband Calibration of Acoustic Emission and Ultrasonic Sensors from Generalized Ray Theory and Finite Element Models

This paper describes a calibration method for acoustic emission and ultrasonic sensors that is effective from 1 kHz to 1 MHz. The method combines generalized ray theory and finite element analysis to model wave propagation at higher and lower frequencies, respectively. A ball impact is used as a calibration source, a thick aluminum plate is used as the test block, and hot glue is used as the couplant. We demonstrate this method on five commercial piezoelectric sensors: Physical Acoustics (PAC) R15a, PAC WSa, Panametrics V101, Panametrics V103, and Valpey-Fisher Pinducer. Our calibration results show that reflections and other wave phases can be more clearly identified with the less-resonant Panametrics sensors. The PAC sensors have the greatest sensitivity and are able to detect surface normal displacements at least down to 1 pm amplitude in the 100s of kHz frequency band. Aperture effect is minimized by the small size of the Pinducer. Our method focuses on the amplitude response of the sensors (phase is ignored) and extends the calibration to a frequency band that is lower than typical analyses. Low frequency information is useful for determining the seismic moment of a seismic source (analogous to the magnitude of an earthquake) and can increase the amount of information acquired in a single recording.

42 ENGINEERING↗