Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALCULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Dose-Response Relationship for Image-Guided Stereotactic Body Radiotherapy of Pulmonary Tumors: Relevance of 4D Dose Calculation

Purpose: To evaluate outcome after image-guided stereotactic body radiotherapy (SBRT) for early-stage non-small-cell lung cancer (NSCLC) and pulmonary metastases. Methods and Materials: A total of 124 patients with 159 pulmonary lesions (metastases n = 118; NSCLC, n = 41; Stage IA, n = 13; Stage IB, n = 19; T3N0, n = 9) were treated with SBRT. Patients were treated with hypofractionated schemata (one to eight fractions of 6-26 Gy); biologic effective doses (BED) to the clinical target volume (CTV) were calculated based on four-dimensional (4D) dose calculation. The position of the pulmonary target was verified using volume imaging before all treatments. Results: With mean/median follow-up of 18/14 months, actuarial local control was 83% at 36 months with no difference between NSCLC and metastases. The dose to the CTV based on 4D dose calculation was closely correlated with local control: local control rates were 89% and 62% at 36 months for >100 Gy and <100 Gy BED (p = 0.0001), respectively. Actuarial freedom from regional and systemic progression was 34% at 36 months for primary NSCLC group; crude rate of regional failure was 15%. Three-year overall survival was 37% for primary NSCLC and 16% for metastases; no dose-response relationship for survival was observed. Exacerbation of comorbidities was the most frequent cause of death for primary NSCLC. Conclusions: Doses of >100 Gy BED to the CTV based on 4D dose calculation resulted in excellent local control rates. This cutoff dose is not specific to the treatment technique and protocol of our study and may serve as a general recommendation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Heterogeneity-Based Dose Calculation Using a Deterministic Grid-Based Boltzmann Equation Solver for Intracavitary Brachytherapy

Purpose: To investigate the dosimetric impact of the heterogeneity dose calculation Acuros (Transpire Inc., Gig Harbor, WA), a grid-based Boltzmann equation solver (GBBS), for brachytherapy in a cohort of cervical cancer patients. Methods and Materials: The impact of heterogeneities was retrospectively assessed in treatment plans for 26 patients who had previously received {sup 192}Ir intracavitary brachytherapy for cervical cancer with computed tomography (CT)/magnetic resonance-compatible tandems and unshielded colpostats. The GBBS models sources, patient boundaries, applicators, and tissue heterogeneities. Multiple GBBS calculations were performed with and without solid model applicator, with and without overriding the patient contour to 1 g/cm{sup 3} muscle, and with and without overriding contrast materials to muscle or 2.25 g/cm{sup 3} bone. Impact of source and boundary modeling, applicator, tissue heterogeneities, and sensitivity of CT-to-material mapping of contrast were derived from the multiple calculations. American Association of Physicists in Medicine Task Group 43 (TG-43) guidelines and the GBBS were compared for the following clinical dosimetric parameters: Manchester points A and B, International Commission on Radiation Units and Measurements (ICRU) report 38 rectal and bladder points, three and nine o'clock, and {sub D2cm3} to the bladder, rectum, and sigmoid. Results: Points A and B, D{sub 2} cm{sup 3} bladder, ICRU bladder, and three and nine o'clock were within 5% of TG-43 for all GBBS calculations. The source and boundary and applicator account for most of the differences between the GBBS and TG-43 guidelines. The D{sub 2cm3} rectum (n = 3), D{sub 2cm3} sigmoid (n = 1), and ICRU rectum (n = 6) had differences of >5% from TG-43 for the worst case incorrect mapping of contrast to bone. Clinical dosimetric parameters were within 5% of TG-43 when rectal and balloon contrast were mapped to bone and radiopaque packing was not overridden. Conclusions: The GBBS has minimal impact on clinical parameters for this cohort of patients with unshielded applicators. The incorrect mapping of rectal and balloon contrast does not have a significant impact on clinical parameters. Rectal parameters may be sensitive to the mapping of radiopaque packing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of On-Board kV Cone Beam Computed Tomography–Based Dose Calculation With Deformable Image Registration Using Hounsfield Unit Modifications

Purpose: The purpose of this study was to estimate the accuracy of the dose calculation of On-Board Imager (Varian, Palo Alto, CA) cone beam computed tomography (CBCT) with deformable image registration (DIR), using the multilevel-threshold (MLT) algorithm and histogram matching (HM) algorithm in pelvic radiation therapy. Methods and Materials: One pelvis phantom and 10 patients with prostate cancer treated with intensity modulated radiation therapy were studied. To minimize the effect of organ deformation and different Hounsfield unit values between planning CT (PCT) and CBCT, we modified CBCT (mCBCT) with DIR by using the MLT (mCBCT{sub MLT}) and HM (mCBCT{sub HM}) algorithms. To evaluate the accuracy of the dose calculation, we compared dose differences in dosimetric parameters (mean dose [D{sub mean}], minimum dose [D{sub min}], and maximum dose [D{sub max}]) for planning target volume, rectum, and bladder between PCT (reference) and CBCTs or mCBCTs. Furthermore, we investigated the effect of organ deformation compared with DIR and rigid registration (RR). We determined whether dose differences between PCT and mCBCTs were significantly lower than in CBCT by using Student t test. Results: For patients, the average dose differences in all dosimetric parameters of CBCT with DIR were smaller than those of CBCT with RR (eg, rectum; 0.54% for DIR vs 1.24% for RR). For the mCBCTs with DIR, the average dose differences in all dosimetric parameters were less than 1.0%. Conclusions: We evaluated the accuracy of the dose calculation in CBCT, mCBCT{sub MLT}, and mCBCT{sub HM} with DIR for 10 patients. The results showed that dose differences in D{sub mean}, D{sub min}, and D{sub max} in mCBCTs were within 1%, which were significantly better than those in CBCT, especially for the rectum (P<.05). Our results indicate that the mCBCT{sub MLT} and mCBCT{sub HM} can be useful for improving the dose calculation for adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Proton Dose Calculation Accuracy in the Lung

Purpose: To quantify the accuracy of a clinical proton treatment planning system (TPS) as well as Monte Carlo (MC)–based dose calculation through measurements and to assess the clinical impact in a cohort of patients with tumors located in the lung. Methods and Materials: A lung phantom and ion chamber array were used to measure the dose to a plane through a tumor embedded in the lung, and to determine the distal fall-off of the proton beam. Results were compared with TPS and MC calculations. Dose distributions in 19 patients (54 fields total) were simulated using MC and compared to the TPS algorithm. Results: MC increased dose calculation accuracy in lung tissue compared with the TPS and reproduced dose measurements in the target to within ±2%. The average difference between measured and predicted dose in a plane through the center of the target was 5.6% for the TPS and 1.6% for MC. MC recalculations in patients showed a mean dose to the clinical target volume on average 3.4% lower than the TPS, exceeding 5% for small fields. For large tumors, MC also predicted consistently higher V5 and V10 to the normal lung, because of a wider lateral penumbra, which was also observed experimentally. Critical structures located distal to the target could show large deviations, although this effect was highly patient specific. Range measurements showed that MC can reduce range uncertainty by a factor of ∼2: the average (maximum) difference to the measured range was 3.9 mm (7.5 mm) for MC and 7 mm (17 mm) for the TPS in lung tissue. Conclusion: Integration of Monte Carlo dose calculation techniques into the clinic would improve treatment quality in proton therapy for lung cancer by avoiding systematic overestimation of target dose and underestimation of dose to normal lung. In addition, the ability to confidently reduce range margins would benefit all patients by potentially lowering toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy

Purpose: To assess the impact of approximations in current analytical dose calculation methods (ADCs) on tumor control probability (TCP) in proton therapy. Methods: Dose distributions planned with ADC were compared with delivered dose distributions as determined by Monte Carlo simulations. A total of 50 patients were investigated in this analysis with 10 patients per site for 5 treatment sites (head and neck, lung, breast, prostate, liver). Differences were evaluated using dosimetric indices based on a dose-volume histogram analysis, a γ-index analysis, and estimations of TCP. Results: We found that ADC overestimated the target doses on average by 1% to 2% for all patients considered. The mean dose, D95, D50, and D02 (the dose value covering 95%, 50% and 2% of the target volume, respectively) were predicted within 5% of the delivered dose. The γ-index passing rate for target volumes was above 96% for a 3%/3 mm criterion. Differences in TCP were up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head and neck, and lung patients, respectively. Differences in normal tissue complication probabilities for bladder and anterior rectum of prostate patients were less than 3%. Conclusion: Our results indicate that current dose calculation algorithms lead to underdosage of the target by as much as 5%, resulting in differences in TCP of up to 11%. To ensure full target coverage, advanced dose calculation methods like Monte Carlo simulations may be necessary in proton therapy. Monte Carlo simulations may also be required to avoid biases resulting from systematic discrepancies in calculated dose distributions for clinical trials comparing proton therapy with conventional radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gradient Theory simulations of pure fluid interfaces using a generalized expression for influence parameters and a Helmholtz energy equation of state for fundamentally consistent two-phase calculations

The fidelity of Gradient Theory simulations depends on the accuracy of saturation properties and influence parameters, and require equations of state (EoS) which exhibit a fundamentally consistent behavior in the two-phase regime. Widely applied multi-parameter EoS, however, are generally invalid inside this region. Hence, they may not be fully suitable for application in concert with Gradient Theory despite their ability to accurately predict saturation properties. The commonly assumed temperature-dependence of pure component influence parameters usually restricts their validity to subcritical temperature regimes. This may distort predictions for general multi-component interfaces where temperatures often exceed the critical temperature of vapor phase components. Then, the calculation of influence parameters is not well defined. In this paper, one of the first studies is presented in which Gradient Theory is combined with a next-generation Helmholtz energy EoS which facilitates fundamentally consistent calculations over the entire two-phase regime. Illustrated on pentafluoroethane as an example, reference simulations using this method are performed. They demonstrate the significance of such high-accuracy and fundamentally consistent calculations for the computation of interfacial properties. These reference simulations are compared to corresponding results from cubic PR EoS, widely-applied in combination with Gradient Theory, and mBWR EoS. The analysis reveals that neither of those two methods succeeds to consistently capture the qualitative distribution of obtained key thermodynamic properties in Gradient Theory. Furthermore, a generalized expression of the pure component influence parameter is presented. This development is informed by its fundamental definition based on the direct correlation function of the homogeneous fluid and by presented high-fidelity simulations of interfacial density profiles. As a result, the new model preserves the accuracy of previous temperature-dependent expressions, remains well-defined at supercritical temperatures, and is fully suitable for calculations of general multi-component two-phase interfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast and accurate calculation of dilute quantum gas using Uehling–Uhlenbeck model equation

The Uehling–Uhlenbeck (U–U) model equation is studied for the fast and accurate calculation of a dilute quantum gas. In particular, the direct simulation Monte Carlo (DSMC) method is used to solve the U–U model equation. DSMC analysis based on the U–U model equation is expected to enable the thermalization to be accurately obtained using a small number of sample particles and the dilute quantum gas dynamics to be calculated in a practical time. Finally, the applicability of DSMC analysis based on the U–U model equation to the fast and accurate calculation of a dilute quantum gas is confirmed by calculating the viscosity coefficient of a Bose gas on the basis of the Green–Kubo expression and the shock layer of a dilute Bose gas around a cylinder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A parallel orbital-updating based plane-wave basis method for electronic structure calculations

Highlights: • Propose three parallel orbital-updating based plane-wave basis methods for electronic structure calculations. • These new methods can avoid the generating of large scale eigenvalue problems and then reduce the computational cost. • These new methods allow for two-level parallelization which is particularly interesting for large scale parallelization. • Numerical experiments show that these new methods are reliable and efficient for large scale calculations on modern supercomputers. - Abstract: Motivated by the recently proposed parallel orbital-updating approach in real space method , we propose a parallel orbital-updating based plane-wave basis method for electronic structure calculations, for solving the corresponding eigenvalue problems. In addition, we propose two new modified parallel orbital-updating methods. Compared to the traditional plane-wave methods, our methods allow for two-level parallelization, which is particularly interesting for large scale parallelization. Numerical experiments show that these new methods are more reliable and efficient for large scale calculations on modern supercomputers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculation of strain compensation thickness for III–V semiconductor quantum dot superlattices

Models based on continuum elasticity theory are discussed to calculate the necessary thickness of a strain compensation (SC) layer for a superlattice (SL) of strained quantum wells (QW) or quantum dots (QD). These models are then expanded to cover material systems (substrates, QW or QD, and SC) composed of AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, or InSb, as well as the ternary, quaternary, and higher order material alloys possible in the Al/Ga/In/P/As/Sb systems. SC thickness calculation methods were compared against dynamical scattering simulations and experimental X-ray diffraction measurements of the InAs/GaP/GaAs QD/SC/Substrate superlattices of varying SC thickness. Based on the reduced (but not eliminated) strain present, a further modified strain compensation thickness is calculated to maximize the number of SL repeat units before the onset of misfit dislocations is also calculated. In conclusion, these models have been assembled into a free application on nanoHUB for use by the community.

36 MATERIALS SCIENCE↗

Phase equilibria in the U-Si system from first-principles calculations

Density functional theory calculations have been used with spin-orbit coupling and on-site Coulomb correction (GGA + U) methods to investigate the U-Si system. Structural prediction methods were employed to identify alternate stable structures. Convex hulls of the U-Si system were constructed for each of the methods to highlight the competing energetics of various phases. For GGA calculations, new structures are predicted to be dynamically stable, but these have not been experimentally observed. When the GGA + U (U eff > 1.3 eV) method is considered, the experimentally observed structures are predicted to be energetically preferred. Phonon calculations were used to investigate the energy predictions and showed that the use of the GGA + U method removes the significant imaginary frequencies observed for U 3 Si 2 when the correction is not considered. In conclusion, total and partial electron density of states calculations were also performed to understand the role of GGA + U methods and orbitals on the bonding and stability of U-Si compounds.

36 MATERIALS SCIENCE↗

Structural, mechanical, and electronic properties of TaB{sub 2}, TaB, IrB{sub 2}, and IrB: First-principle calculations

First-principle calculations were performed to investigate the structural, elastic, and electronic properties of TaB{sub 2}, TaB, IrB{sub 2}, and IrB. The calculated equilibrium structural parameters, shear modulus, and Young's modulus of TaB{sub 2} are well consistent with the available experimental data, and TaB{sub 2} with P6/mmm space group has stronger directional bonding between ions than WB{sub 2}, OsB{sub 2}, IrN{sub 2}, and PtN{sub 2}. For TaB{sub 2}, the hexagonal P6/mmm structure is more stable than the orthorhombic Pmmn one, while for IrB{sub 2} the orthorhombic Pmmn structure is the most stable one. The high shear modulus of P6/mmm phase TaB{sub 2} is mainly due to the strong covalent pi-bonding of B-hexagon in the (0001) plane. Such a B-hexagon network can strongly resist against an applied [112-bar0] (0001) shear deformation. Correlation between the hardness and the elastic constants of TaB{sub 2} was discussed. The band structure shows that P6/mmm phase TaB{sub 2} and Pmmn phase IrB{sub 2} are both metallic. The calculations show that both TaB and IrB are elastically stable with the hexagonal P6{sub 3}/mmc structure. - Elastic constant c{sub 44} of TaB{sub 2} is calculated to be 235 GPa. This value is exceptionally high, exceeding those of WB{sub 2}, OsB{sub 2}, WB{sub 4}, OsN{sub 2}, IrN{sub 2}, and PtN{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The calculated magnetic, electronic and thermodynamic properties of Ce{sub 3}Co{sub 29}Si{sub 4}B{sub 10} compound

The magnetic moment, lattice parameter and atom fraction coordinates for Ce{sub 3}Co{sub 29}Si{sub 4}B{sub 10} are calculated by the first-principles GGA+U method, and the results indicate that the calculated and experimental values are basically accordant when U=2.6 eV. We study the interaction effect and orbital hybridization between Co and Ce atoms. The projected density of states at U=2.6 eV which provided by Co-2c, Ce-2b and Ce-4d sites are contrasted with else U values. Meanwhile the electron density of states for different sites and the distance between various atoms are exhibited. In addition, the thermodynamic properties of Ce{sub 3}Co{sub 29}Si{sub 4}B{sub 10} are evaluated by using a series of interatomic pair potentials. - Graphical abstract: Change of the total magnetic moment for Ce{sub 3}Co{sub 29}Si{sub 4}B{sub 10} along with the value of U. There is a sharply decline of the curve at U=2.6 eV and, at the moment, the total magnetic moment of the compound have a good agreement with the experimental data. - Highlights: • We research of quaternary rare earth and transition metal compounds. • We perform the calculation of magnetic moment and electronic structure by GGA+U method. • The orbital hybridization between Co and Ce atoms is displayed and analyzed. • Show the plot of projected density of states for different sites more clearly. • Calculate the thermodynamic property of rare-earth transition metal compound.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling computational thermodynamics with density-function-theory based calculations to design L12 precipitates in Fe Ni based alloys

Achieving a high-volume fraction of thermodynamically stable L12-type precipitates that are resistant to coarsening is of great importance for the development of low-cost FeNi based austenitic steels. With the aid of computational thermodynamics, this work designed two model alloys: Fe-37.4Ni-6.1Al-2.9Ti (FNAT) and Fe-45.2Ni-5.9Al-8.5Si (FNAS). Both alloys were designed to contain a similar amount of L1 2 precipitate in Fe-Ni matrix without forming other precipitates. Density-Function-Theory (DFT) calculation was coupled with computational thermodynamics to predict the critical radius at which the precipitates change shape from spherical to cuboidal. The calculation results suggest that critical radius for the FNAT alloy is about two orders of magnitude larger than that for the FeNiAlSi alloy. Phase stability and morphology of the L1 2 precipitates in these two alloys were experimentally investigated through X-ray diffraction, atom probe tomography, and scanning and transmission electron microscopy. The L1 2 precipitates in the FeNiAlSi system were found to be cuboidal and rod shaped, with much larger size than the spherical ones in the FeNiAlTi system, agreeing with the calculation results. This work suggested that coupling computational thermodynamics with DFT calculations can be reliably used to design L1 2 precipitates in FeNi based alloys.

36 MATERIALS SCIENCE↗

Dose Calculation on KV Cone Beam CT Images: An Investigation of the Hu-Density Conversion Stability and Dose Accuracy Using the Site-Specific Calibration

Precise calibration of Hounsfield units (HU) to electron density (HU-density) is essential to dose calculation. On-board kV cone beam computed tomography (CBCT) imaging is used predominantly for patients' positioning, but will potentially be used for dose calculation. The impacts of varying 3 imaging parameters (mAs, source-imager distance [SID], and cone angle) and phantom size on the HU number accuracy and HU-density calibrations for CBCT imaging were studied. We proposed a site-specific calibration method to achieve higher accuracy in CBCT image-based dose calculation. Three configurations of the Computerized Imaging Reference Systems (CIRS) water equivalent electron density phantom were used to simulate sites including head, lungs, and lower body (abdomen/pelvis). The planning computed tomography (CT) scan was used as the baseline for comparisons. CBCT scans of these phantom configurations were performed using Varian Trilogy{sup TM} system in a precalibrated mode with fixed tube voltage (125 kVp), but varied mAs, SID, and cone angle. An HU-density curve was generated and evaluated for each set of scan parameters. Three HU-density tables generated using different phantom configurations with the same imaging parameter settings were selected for dose calculation on CBCT images for an accuracy comparison. Changing mAs or SID had small impact on HU numbers. For adipose tissue, the HU discrepancy from the baseline was 20 HU in a small phantom, but 5 times lager in a large phantom. Yet, reducing the cone angle significantly decreases the HU discrepancy. The HU-density table was also affected accordingly. By performing dose comparison between CT and CBCT image-based plans, results showed that using the site-specific HU-density tables to calibrate CBCT images of different sites improves the dose accuracy to {approx}2%. Our phantom study showed that CBCT imaging can be a feasible option for dose computation in adaptive radiotherapy approach if the site-specific calibration is applied.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of peripheral underdosage at the lung-tumor interface using Monte Carlo radiation transport calculations

Prediction of dose distributions in close proximity to interfaces is difficult. In the context of radiotherapy of lung tumors, this may affect the minimum dose received by lesions and is particularly important when prescribing dose to covering isodoses. The objective of this work is to quantify underdosage in key regions around a hypothetical target using Monte Carlo dose calculation methods, and to develop a factor for clinical estimation of such underdosage. A systematic set of calculations are undertaken using 2 Monte Carlo radiation transport codes (EGSnrc and GEANT4). Discrepancies in dose are determined for a number of parameters, including beam energy, tumor size, field size, and distance from chest wall. Calculations were performed for 1-mm{sup 3} regions at proximal, distal, and lateral aspects of a spherical tumor, determined for a 6-MV and a 15-MV photon beam. The simulations indicate regions of tumor underdose at the tumor-lung interface. Results are presented as ratios of the dose at key peripheral regions to the dose at the center of the tumor, a point at which the treatment planning system (TPS) predicts the dose more reliably. Comparison with TPS data (pencil-beam convolution) indicates such underdosage would not have been predicted accurately in the clinic. We define a dose reduction factor (DRF) as the average of the dose in the periphery in the 6 cardinal directions divided by the central dose in the target, the mean of which is 0.97 and 0.95 for a 6-MV and 15-MV beam, respectively. The DRF can assist clinicians in the estimation of the magnitude of potential discrepancies between prescribed and delivered dose distributions as a function of tumor size and location. Calculation for a systematic set of 'generic' tumors allows application to many classes of patient case, and is particularly useful for interpreting clinical trial data.

61 RADIATION PROTECTION AND DOSIMETRY↗

An analytical method to calculate equivalent fields to irregular symmetric and asymmetric photon fields

Equivalent field is frequently used for central axis depth-dose calculations of rectangular- and irregular-shaped photon beams. As most of the proposed models to calculate the equivalent square field are dosimetry based, a simple physical-based method to calculate the equivalent square field size was used as the basis of this study. The table of the sides of the equivalent square or rectangular fields was constructed and then compared with the well-known tables by BJR and Venselaar, et al. with the average relative error percentage of 2.5 ± 2.5% and 1.5 ± 1.5%, respectively. To evaluate the accuracy of this method, the percentage depth doses (PDDs) were measured for some special irregular symmetric and asymmetric treatment fields and their equivalent squares for Siemens Primus Plus linear accelerator for both energies, 6 and 18 MV. The mean relative differences of PDDs measurement for these fields and their equivalent square was approximately 1% or less. As a result, this method can be employed to calculate equivalent field not only for rectangular fields but also for any irregular symmetric or asymmetric field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of deformed image-based dose calculations for adaptive radiotherapy of nasopharyngeal carcinoma

The ultimate goal of adaptive radiotherapy (ART) is to deliver truly customized radiation treatments. Currently, the quality of cone-beam computed tomography (CBCT) images is still inferior to that of conventional CT images in contour delineations and dose calculations for replanning purposes. This retrospective study aims to evaluate the dosimetric accuracy of using deformed conventional CT images for dose calculations, in the hope of inferring the feasibility of ART using planning CT (PCT) images that deformed to up-to-date CBCT images for patients with nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC who had undergone 1 replan in their radiotherapy treatments were selected. The pretreatment PCT images were deformed to match the mid-treatment PCT images by deformable image registration. The same volumetric modulated arc therapy plan was then calculated on the deformed PCT images. The resulting dose distributions and dose volume histograms of the tumors and organs at risk (OARs) were compared with the original plan. Five dose levels, D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%}, were recorded for 9 NPC targets. Four dose levels, D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean}, were recorded for 15 OARs. The greatest percentage difference in observed dose for D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%} of the targets were 1.71%, 1.55%, 0.64%, 0.97%, and 1.13%, respectively. The greatest percentage difference in observed dose for D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean} of the OARs were -26.51% (left optic nerve), -17.06% (left optic nerve), 56.70% (spinal cord), and 18.97% (spinal cord), respectively. In addition, 29 of 45 (64%) dosimetric end points of the targets showed statistically significant dose differences (p p < 0.05). Dose calculations using deformed PCT images could result in significant dose uncertainties in target volumes and OARs. Larger dose deviations were found in OARs in comparison with target volumes. The spinal cord and optic nerve showed the greatest percentage dose differences and the clinical significance has yet to be determined. Deformable registration error was believed to be the problem causing the dose deviations. Owing to unknown clinical significanceof dose deviation results obtained from this study, a conventional CT scan is still required for replanning in patients with NPC who are experiencing significant anatomical changes during the course of radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A modified formula for dose calculations of stereotactic ablative body radiotherapy for non–small cell lung cancer

To provide a modified formula consistent with the Monte Carlo (MC) algorithm for dose calculations during stereotactic ablative body radiotherapy for non–small cell lung cancer. Seventy CyberKnife treatment plans were calculated and analyzed by MC and ray-tracing (RT) algorithms, separately. Parameters of treatment plans were compared, and those associated with differences of dose distributions were analyzed to establish a modified formula. Gross tumor volume and tumor tracking volume (TTV) were defined as the evident disease on the sequences of the window width and level of the lung and the mediastinum. Additionally, the formula was validated by another 20 plans. The prescription dose of the 90 patients was 60 Gy/5f. The RT algorithm overestimated the planning target volume (PTV) D{sub 95} by an average of 8.59 Gy and the gross tumor volume D{sub 99} by an average of 5.84 Gy. The homogeneity index of PTV was underestimated by 0.11 on average, whereas the conformity index and new conformity index was underestimated by 0.05. The RT algorithm overestimated the dose distribution to the spinal cord by 2.23 Gy, the esophagus by 1.96 Gy, the trachea by 1.89 Gy, the left-sided bronchus by 1.77 Gy, the right-sided bronchus by 1.64 Gy, and the heart by 2.16 Gy. The average whole-lung dose volumes of lung tissues and dose volumes of V{sub 5} were overestimated by 2.69 Gy and 7.52%, respectively. A power function distribution (R{sup 2} = 0.8626) was confirmed between PTV D{sub 95} and TTV volumes. PTV D{sub 95} calculated by the MC algorithm could be computed easily with TTV and PTV D{sub 95} calculated by the RT algorithm based on the formula. The modified equation was more consistent with MC algorithm than with other formula, which could be a reference to those not accessible to the MC algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗