At least 1,063 records · Page 59

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Analysis of Energy Savings and CO2 Emission Reduction Contribution for Industrial Facilities in USA

Abstract Energy audits can identify energy consumptions, energy costs of the facility and evolve to develop measures to maximize efficiency, optimize supply energy, and eliminate waste. This paper investigates the potential energy savings at 20 different industrial sectors with 152 assessments for various facilities in Wisconsin, USA. On average, eight energy recommendations were suggested and applied in each facility. This paper provides a detailed guideline for each industry in terms of eight different energy categories: heating, ventilation, and air conditioning (HVAC) systems, heat recovery systems, electrical demand management, and utility bills, motors, compressors, waste management, and productivity enhancement, lighting, besides building envelope. In total, the energy savings were as follows: 98 million kWh in the shape of electricity, 561 billion British thermal units (BTUs) gas savings, 44 million gallons water savings, and 2-million-pound solid waste savings. Based on these savings, a 100-thousand-ton reduction in carbon dioxide emissions was obtained.

Energy & Fuels↗

A new approach to both high safety and high performance of lithium-ion batteries

We present a novel concept to achieve high performance and high safety simultaneously by passivating a Li-ion cell and then self-heating before use. By adding a small amount of triallyl phosphate in conventional electrolytes, we show that resistances of the passivated cells can increase by ~5×, thereby ensuring high safety and thermal stability. High power before battery operation is delivered by self-heating to an elevated temperature such as 60°C within tens of seconds. The present approach of building a resistive cell with highly stable materials and then delivering high power on demand through rapid thermal stimulation leads to a revolutionary route to high safety when batteries are not in use and high battery performance upon operation.

36 MATERIALS SCIENCE↗

Life Cycle Water Consumption and Water Resource Assessment for Utility-Scale Geothermal Systems: An In-Depth Analysis of Historical and Forthcoming EGS Projects

This report is the third in a series of reports sponsored by the U.S. Department of Energy Geothermal Technologies Program in which a range of water-related issues surrounding geothermal power production are evaluated. The first report made an initial attempt at quantifying the life cycle fresh water requirements of geothermal power-generating systems and explored operational and environmental concerns related to the geochemical composition of geothermal fluids. The initial analysis of life cycle fresh water consumption of geothermal power-generating systems identified that operational water requirements consumed the vast majority of water across the life cycle. However, it relied upon limited operational water consumption data and did not account for belowground operational losses for enhanced geothermal systems (EGSs). A second report presented an initial assessment of fresh water demand for future growth in utility-scale geothermal power generation. The current analysis builds upon this work to improve life cycle fresh water consumption estimates and incorporates regional water availability into the resource assessment to improve the identification of areas where future growth in geothermal electricity generation may encounter water challenges.

15 GEOTHERMAL ENERGY↗

City of San Antonio, Texas Better Buildings Program

The San Antonio Better Buildings Program is a unified single-point-of-service energy efficiency delivery mechanism targeting residential, commercial, institutional, industrial and public buildings. This comprehensive and replicable energy efficiency program is designed to be an effective demand side management initiative to provide a seamless process for program participants to have turn-key access to expert analysis, support and incentives to improve the performance of their in-place energy using systems, while reducing electrical energy use and demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Sensor for Measuring Pump Efficiency: Small Business Voucher Project with KCF Technologies

This document is to fulfill the final report requirements for the Small Business Voucher (SBV) CRADA project with ORNL and KCF Technologies (CRADA/NFE-16-06133). Pumping systems account for nearly 20% of the world’s electrical energy demand and range from 25-50% of the energy usage in many industrial and building power plants. The energy cost is the largest element in the total cost of owning a pump (~40%). In response to a recent DOE mandate for improved pump efficiency pump manufacturers are preparing for the changes that the impending regulations will bring, including design improvements. This mandate also establishes a need for new low cost pump efficiency measurement systems. The standard industry definition of pump efficiency is the mechanical water horsepower delivered divided by the electrical horsepower input to the motor. KCF Technologies has developed a new sensor measurement technique to estimate fluid pump efficiency using a thermodynamic approach. KCF Technologies applied for a SBV grant with ORNL as the research partner. KCF needed a research partner with the proper facilities to demonstrate the efficacy of its wireless sensor unit for measuring pump efficiency. The ORNL Building Technologies Research and Integration Center (BTRIC) test resources were used to test and demonstrate the successful measurement of pump efficiency with the KCF sensor technology. KCF is now working on next steps to commercialize this sensing technology.

42 ENGINEERING↗

The impact of ride hailing on parking (and vice versa)

Researching emerging transportation services is critical to forecasting mode choice and providing appropriate infrastructure. One such infrastructure is parking, as parking demand may shift with the availability of ride-hailing services. This study uses ethnographic methods - complemented with passenger surveys collected when driving for Uber and Lyft in the Denver, Colorado, region - to gather quantitative and qualitative data on ride-hailing and analyze the impacts of ride-hailing on parking, including changes in parking demand and parking as a reason to deter driving. The study also examines relationships between parking time and cost. This includes building a classification tree-based model to predict the replaced driving trips as a function of car ownership, destination land type, parking stress, and demographics. The results suggest that: i) ride-hailing is replacing driving trips and could reduce parking demand, particularly at land uses such as airports, event venues, restaurants, and bars; ii) parking stress is a key reason respondents chose not to drive; and iii) respondents are generally willing to pay more for reduced parking time and distance. Conversely, parking supply, time, and cost can all influence travel behavior and ride-hailing use. This work provides insight into potential benefits and disadvantages of ride-hailing as related to parking.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High temperature dynamic engine seal technology development

Combined cycle ramjet/scramjet engines being designed for advanced hypersonic vehicles, including the National Aerospace Plane (NASP), require innovative high temperature dynamic seals to seal the sliding interfaces of the articulated engine panels. New seals are required that will operate hot (1200 to 2000 F), seal pressures ranging from 0 to 100 psi, remain flexible to accommodate significant sidewall distortions, and resist abrasion over the engine's operational life. This report reviews the recent high temperature durability screening assessments of a new braided rope seal concept, braided of emerging high temperature materials, that shows promise of meeting many of the seal demands of hypersonic engines. The paper presents durability data for: (1) the fundamental seal building blocks, a range of candidate ceramic fiber tows; and for (2) braided rope seal subelements scrubbed under engine simulated sliding, temperature, and preload conditions. Seal material/architecture attributes and limitations are identified through the investigations performed. The paper summarizes the current seal technology development status and presents areas in which future work will be performed.

Steinetz, Bruce M.↗

Clustering Days with Similar Airport Weather Conditions

On any given day, traffic flow managers must often rely on past experience and intuition when developing traffic flow management initiatives that mitigate imbalances between the aircraft demand and the weather impacted airport capacity. The goal of this study was to build on recent efforts to apply data mining classification and clustering algorithms to vast archives of historical weather and air traffic data to identify patterns and past decisions that can ultimately inform day-of-operations decision-making. More specifically, this study identified similar weather impacted days at select U.S. airports, and analyzed the traffic management initiatives implemented on these representative days. The identification of the similar days was accomplished by applying a decision tree algorithm to the hourly Localized Aviation Model Output Statistics Program observations and the arrival delays for Newark Liberty International Airport. The branches from the trained decision tree were subsequently pruned to identify four weather conditions that resulted in medium to high delays for the arrivals scheduled to Newark in 2012. Using these weather conditions, four, daily airport-level Weather Impacted Traffic Index values were calculated using the Localized Aviation Model Output Statistics Program observations and the 2012 scheduled arrival counts from the FAAs Aviation System Performance Metric system. The four, daily Weather Impacted Traffic Index values for 2012 were subsequently clustered using an Expectation Maximization clustering algorithm, and nine unique types of weather days at Newark were identified. By far the most prominent type of day at Newark was a day associated with relatively good weather conditions, where there was little convective activity, winds were low, ceilings and visibility were high and there was little precipitation. Moderate levels of convective activity characterized the next most prominent type of day. Days with persistently high winds or low ceiling and visibility levels were relatively rare in 2012. Lastly, the frequency at which Ground Delay Programs, Ground Stops and Miles-in-Trail restrictions were implemented on each of the typical types of days at Newark were analyzed. Based on the results, it does appear as if the usage of Miles-in-Trail, Ground Delay Program and Ground Stop restrictions correlates well with the severity of the weather associated with each unique type of weather impacted day at Newark. Furthermore, the results demonstrate that it is feasible to use historical weather and air traffic archives to provide guidance on the types of traffic management restrictions to implement in response to the weather conditions impacting an airport.

traffic flow management↗

Clustering Days with Similar Airport Weather Conditions

On any given day, traffic flow managers must often rely on past experience and intuition when developing traffic flow management initiatives that mitigate imbalances between the aircraft demand and the weather impacted airport capacity. The goal of this study was to build on recent efforts to apply data mining classification and clustering algorithms to vast archives of historical weather and air traffic data to identify patterns and past decisions that can ultimately inform day-of-operations decision-making. More specifically, this study identified similar weather impacted days at select U.S. airports, and analyzed the traffic management initiatives implemented on these representative days. The identification of the similar days was accomplished by applying a decision tree algorithm to the hourly Localized Aviation Model Output Statistics Program observations and the arrival delays for Newark Liberty International Airport. The branches from the trained decision tree were subsequently pruned to identify four weather conditions that resulted in medium to high delays for the arrivals scheduled to Newark in 2012. Using these weather conditions, four, daily airport-level Weather Impacted Traffic Index values were calculated using the Localized Aviation Model Output Statistics Program observations and the 2012 scheduled arrival counts from the FAAs Aviation System Performance Metric system. The four, daily Weather Impacted Traffic Index values for 2012 were subsequently clustered using an Expectation Maximization clustering algorithm, and nine unique types of weather days at Newark were identified. By far the most prominent type of day at Newark was a day associated with relatively good weather conditions, where there was little convective activity, winds were low, ceilings and visibility were high and there was little precipitation. Moderate levels of convective activity characterized the next most prominent type of day. Days with persistently high winds or low ceiling and visibility levels were relatively rare in 2012. Lastly, the frequency at which Ground Delay Programs, Ground Stops and Miles-in-Trail restrictions were implemented on each of the typical types of days at Newark were analyzed. Based on the results, it does appear as if the usage of Miles-in-Trail, Ground Delay Program and Ground Stop restrictions correlates well with the severity of the weather associated with each unique type of weather impacted day at Newark. Furthermore, the results demonstrate that it is feasible to use historical weather and air traffic archives to provide guidance on the types of traffic management restrictions to implement in response to the weather conditions impacting an airport.

weather↗

Combined Heat and Power Technology Fact Sheet Series: Thermal Energy Storage

This fact sheet provides an overview of thermal energy storage (TES) technologies, which heat or cool a storage medium and, when needed, deliver the stored thermal energy to meet heating or cooling needs. TES systems are used in commercial buildings, industrial processes, and district energy installations to deliver stored thermal energy during peak demand periods, thereby reducing peak energy use. TES systems are often integrated with electric or absorption chillers to reduce peak electricity costs and, in the case of new construction, to reduce capital costs by optimizing chiller size. TES technologies can support sites that have either renewable or fossil power generation, including combined heat and power (CHP) installations. With CHP, TES can help optimize equipment size by reducing the required peak CHP thermal capacity and increasing annual CHP usage. TES can also provide turbine inlet cooling for gas turbines used in CHP applications, which increases power production in hot ambient conditions.

Combined Heat and Power, CHP, Thermal Energy, Tech↗

Glass/Glass Photovoltaic Module Reliability and Degradation: A Review - Figures

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

transparent backsheet↗

Climate-Water-Electricity Interactions in the U.S. Under Alternative Decarbonized Futures

The U.S. electric sector is rapidly evolving, with widespread renewable energy deployment, building and transport electrification, and nuanced decarbonization policies. Climate change influences the supply and demand for electricity by altering water resources for cooling and hydropower, thermal plant efficiencies, and heating and cooling demand. This research combines global climate model data, asset-level water and streamflow modeling, and electric sector capacity expansion modeling to study climate-water-electricity interactions across myriad future climate and electricity scenarios that consider electrification and decarbonization using renewable, hydrogen, carbon capture, and nuclear technologies. Multi-model integration leads to insights into power-water sector interactions and their impacts on grid economics and environmental outcomes.

climate change↗

A neural-network-enhanced parameter-varying framework for multi-objective model predictive control applied to buildings

Management of the electrical grid is becoming more complex due to the increased penetration of alternative energy generation technologies and a broadening diversity of electric loads. This complexity creates challenges in balancing demand and generation that can increase the potential for grid instabilities. One effective way to address this issue is to leverage previously unexploited demand flexibility through advanced control strategies. In this work, we propose an advanced control method, called adaptive neural parameter-varying model predictive control (ANPV-MPC), to control the temperature and energy consumption of a building via its Heating, Ventilation, and Air Conditioning system. ANPV-MPC combines key ideas in parameter-varying control, adaptive control, and online learning strategies to bridge the gap between computationally efficient linear model predictive control and more accurate nonlinear model predictive control. The novelty in ANPV-MPC is the use of a physics-inspired Bayesian neural network to estimate the coefficients of the parameter-varying linear control model. The Bayesian neural network additionally provides uncertainty estimates, triggering online training to capture evolving building system conditions. We show that ANPV-MPC can approximate the building system dynamics with a 28.39% higher accuracy than traditional linear model predictive control, resulting in 36.23% better control performance without increasing complexity of the optimal control problem. ANPV-MPC also adapts in real time to previously unseen conditions using online learning, further improving its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous byproducts of laboratory research activities or airborne pathogens. As a result, building ventilation is a primary defense against unseen airborne hazards. Critical laboratory facilities require effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an in-depth intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently many contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in critical laboratory environments. In this article, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories. This article describes a low-cost sensor to support providing a safe, healthy building environment and reduce energy use through effective and efficient ventilation.

dynamic management of indoor air quality↗

Building America Case Study: Low-Load Space-Conditioning Needs Assessment, Northeast and Mid-Atlantic; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment - thus facing penalties in system efficiency, comfort, and cost. To bridge the gap between currently available HVAC equipment and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of multifamily buildings and single-family homes market needs. Over the past decade, Steven Winter Associates, Inc. (SWA) has provided certification and consulting services on hundreds of housing projects and has accrued a large pool of data. CARB compiled and analyzed these data to see what the thermal load ranges are in various multifamily apartments and attached single-family home types (duplex and townhouse). In total, design loads from 941 dwellings from SWA's recent multifamily and attached single-family work across the Northeast and Mid-Atlantic were analyzed. Information on the dwelling characteristics, design loads, and the specifications of installed mechanical equipment were analyzed to determine any trends that exist within the dataset. Of the 941 dwellings, CARB found that only 1% had right-sized heating equipment and 6% of the dwellings had right-sized cooling equipment (within 25% or less of design load).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximum demand charge rates for commercial and industrial electricity tariffs in the United States

NREL has assembled a list of U.S. retail electricity tariffs and their associated demand charge rates for the Commercial and Industrial sectors. The data was obtained from the Utility Rate Database. Keep the following information in mind when interpreting the data: (1) These data were interpreted and transcribed manually from utility tariff sheets, which are often complex. It is a certainty that these data contain errors, and therefore should only be used as a reference. Actual utility tariff sheets should be consulted if an action requires this type of data. (2) These data only contains tariffs that were entered into the Utility Rate Database. Since not all tariffs are designed in a format that can be entered into the Database, this list is incomplete - it does not contain all tariffs in the United States. (3) These data may have changed since this list was developed (4) Many of the underlying tariffs have additional restrictions or requirements that are not represented here. For example, they may only be available to the agricultural sector or closed to new customers. (5) If there are multiple demand charge elements in a given tariff, the maximum demand charge is the sum of each of the elements at any point in time. Where tiers were present, the highest rate tier was assumed. The value is a maximum for the year, and may be significantly different from demand charge rates at other times in the year. Utility Rate Database: https://openei.org/wiki/Utility_Rate_Database For updated dataset as of May 8, 2026 see https://data.openei.org/submissions/8685

/kW↗