Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Balloon-borne Infrared Telescope (BIRT) for far-infrared spectroscopy

The Japanese-made Balloon-borne Infrared Telescope (BIRT) designed for FIR astronomy is described. The BIRT system includes a 50-cm-diam telescope; an attitude-control system consisting of an attitude stabilization and a pointing and tracking subsystems; the ground support system consisting of four personal-computer systems; and electronics consisting of three small computer systems, servo circuits, power amplifiers, and other small circuits. Between 1985 and 1988, the BIRT has flown eight times, demonstrating that it is able to provide a suitable telescope observations on a stable platform with a long integration time. Structural diagrams of the BIRT overall system, the optical system, and the wobbling mechanism are presented along with a block diagram of the on-board electronics.

Shibai, Hiroshi↗

New method for scanning spacecraft and balloon-borne/space-based experiments

A new method is presented for scanning balloon-borne experiments, free-flying spacecraft, and gimballed experiments mounted to the space shuttle or the space station. It uses rotating-unbalanced-mass (RUM) devices for generating circular, line, or raster scan patterns and an auxiliary control system for target acquisition, keeping the scan centered on the target, and producing complementary motion for raster scanning. It is ideal for applications where the only possible way to accomplish the required scan is to physically scan the entire experiment or spacecraft as in X-ray and gamma ray experiments. In such cases, this new method should have advantages over prior methods in terms of either power, weight, cost, performance, stability, or a combination of these.

Polites, Michael E.↗

Results of the 1991 NASA/JPL balloon flight solar cell calibration program

The 1991 solar cell calibration balloon flight was completed on August 1, 1991. All objectives of the flight program were met. Thirty-nine modules were carried to an altitude of 119,000 ft. (36.3 km). Data telemetered from the modules were corrected to 28 C and to 1 AU. The calibrated cells have been returned to the participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗

Rotating-unbalanced-mass devices and methods for scanning balloon-borne-experiments, free-flying spacecraft, and space shuttle/space station attached experiments

A method and apparatus for scanning balloon-borne experiments, free-flying spacecraft, or gimballed experiments mounted on a space shuttle or space station, makes use of one or more rotating unbalanced mass devices for selectively generating circular, line, or raster scan patterns for the experiment line of sight. An auxiliary control system may also be used in combination with the rotating unbalanced mass device, for target acquisition, keeping the scan centered on the target, or for producing complementary motion for raster scanning. The rotating unbalanced mass makes use of a mass associated with a drive shaft, such mass having a center of gravity which is displaced from the drive shaft rotation axis. The drive shaft is driven with a substantially constant angular velocity, thereby resulting in relatively low power requirements since no acceleration or deceleration of the mass is generally involved during steady state operations. The resulting centrifugal force of the rotating unbalanced mass is used to generate desired reaction forces on the experiment or spacecraft to create a desired scan pattern for the experiment line of sight.

Polites, Michael E.↗

A balloon-borne payload for imaging hard X-rays and gamma rays from solar flares

Hard X-rays and gamma rays provide direct evidence of the roles of accelerated particles in solar flares. An approach that employs a spatial Fourier-transform technique for imaging the sources of these emissions is described, and the development of a balloon-borne imaging device based on this instrumental technique is presented. The detectors, together with the imaging optics, are sensitive to hard X-ray and gamma-ray emission in the energy-range from 20 to 700 keV. This payload, scheduled for its first flight in June 1992, will provide 11-arc second angular resolution and millisecond time resolution with a whole-sun field of view. For subsequent flights, the effective detector area can be increased by as much as a factor of four, and imaging optics with angular resolution as fine as 2 arcsec can be added to the existing gondola and metering structures.

Crannell, Carol J.↗

Joint US-USSR Long duration Antarctic Mars calibration Balloon (LAMB) mission

The Long duration Antarctic Mars calibration Balloon (LAMB) project has been established at Goddard Space Flight Center for the evaluation and cross calibration of U.S. and USSR remote sensing gamma-ray and neutron detectors. These detectors are analogs of those flown on the Soviet Phobos mission around Mars and those to be flown on the upcoming U.S. Mars Observer mission. Cosmic rays, which are normally filtered out by the atmosphere, and the earth's magnetic field, will induce gamma-ray and neutron emissions from about a half ton of simulated Mars soil aboard the gondola. The cross calibration of these instruments should greatly facilitate the data analysis from both missions and play a role in U.S.-USSR cooperation in space.

Floyd, S. R.↗

Development of a fracture toughness test for balloon film

This paper describes the equipment and test procedures being developed in an ongoing project to measure J(c) for film in a biaxial stress state. The objective of the research is to confirm J(c) as a material property whose value will permit the initiation of film tear growth to be predicted. Results are presented for two polyethylene balloon films, an LDPE and LLDPE, of thickness 0.8 mil.

Tielking, John T.↗

An assessment on the validity of toughness as a balloon film discriminator

Uniaxial and ball burst toughness for eight commercial polyethylene balloon films have been investigated and compared. Uniaxial toughness was measured in both machine and transverse directions using a rectangular sample 25.4 mm wide by 50.8 mm gage length with an average nominal thickness of 20.32 microns (0.8 mils). Ball burst toughness was measured using a ball burst test fixture with 127 mm hole diameter and 50.8 mm ball diameter resulting in a 0.4 ball to hole diameter ratio. Both the size and shape of the deformed area were observed and the ball burst toughness was calculated based on the deformed area of the film instead of the full area. Specimens were tested at 23 C and -80 C and cross head speed was maintained at 508 mm per minute. The uniaxial toughness were in general, higher than the ball burst toughness. The toughness of the films varied from 12 to 365 MPa when measured uniaxially and from 24 to 73 MPa when measured in the ball burst test. Further investigation showed an apparent correlation between film performance in flight as measured by its stress index and its toughness.

Said, Magdi A.↗

Balloon borne optical disk mass storage system

An on-board data recording system for balloon-borne interferometer using a vacuum operable, ruggedized WORM optical drive is presented. This system, as presently under development, provides 320 Mbytes of data storage (or approximately 11 hrs at the 64 kbits/sec telemetry rate of the experiment). It has the capability of recording the unmodified telemetry bit system as transmitted or doing some preprocessing of the data onboard. The system is compact and requires less than 28 watts of battery power to operate.

Vanek, M. D.↗

Preliminary results of a balloon flight of the solar disk sextant

Preliminary results of a balloon flight on October 11, 1991, of the solar disk sextant (SDS) experiment are reported. The SDS is an instrument which measures the solar diameter at different orientations with respect to the solar polar axis. Fitting straight lines through two fixed-angle data sets with time as the independent variable yields slopes of (7.1 +/ - 1.5) x 10 exp -3 and (6.7 +/- 1.6) x 10 exp -3/mas s, consistent with the value of 6.47 x 10 exp -3/mas s expected from the earth's approach to the sun due to the orbital motion toward perihelion. Upon the instrument's rotation on its axis a sinusoidal component of the diameter measurement was observed in each rotation cycle, with a variable amplitude of about 150 mas. The present result is epsilon of (5.6 +/- 6.3) x 10 exp -6, about 30 deg offset from the polar-equator position. The absolute diameter obtained by means of the FFT definition is found to be 1919.269 +/- 0.240 arcsec or 1919.131 +/- 0.240 arcsec, depending on the orientation mode of the measurement.

Maier, E.↗

Polarization analysis of a balloon-borne solar magnetograph

The main text of the report contains the particular results of our research which relate to the Experimental Vector Magnetograph (EXVM) and the Balloon-borne Vector Magnetograph (BVM). A brief overview of which elements in the EXVM and BVM that are relevant to this polarization analysis are presented. The possible meaning of the 10(exp -5) polarization specification for the BVM is discussed qualitatively. A recommendation of which polarization specification is most relevant for the BVM is provided. A diattenuation budget for the various surfaces in the BVM which will allow the polarization specification to be met is discussed. An explanation of the various coating specifications which are recommended is presented. Optical design of the EXVM and coating specification sheets for the BVM are presented. The appendices of this report contain the more general results of our research on the general topic of polarization aberrations. A general discussion of polarization aberration theory, in terms of the SAMEX solar magnetograph, and rigorous derivations for the Mueller matrices of optical systems are also presented in the appendices.

Reiley, Daniel J.↗

Results of the 1992 NASA/JPL Balloon Flight Solar Cell Calibration Program

The 1992 solar cell calibration balloon flight was completed on August 1, 1992. All objectives of the flight program were met. Forty-one modules were carried to an altitude of 119,000 ft (36.3 km). Data telemetered from the modules was corrected to 28 C and 1 AU. The calibrated cells have been returned to 39 participants and can now be used as reference standards in simulator testing of cells and arrays.

Anspaugh, B. E.↗

Feasibility study of a long duration balloon flight with NASA/GSFC and Soviet Space Agency Gamma Ray Spectrometers

A feasibility study of conducting a joint NASA/GSFC and Soviet Space Agency long duration balloon flight at the Antarctic in Jan. 1993 is reported. The objective of the mission is the verification and calibration of gamma ray and neutron remote sensing instruments which can be used to obtain geochemical maps of the surface of planetary bodies. The gamma ray instruments in question are the GRAD and the Soviet Phobos prototype. The neutron detectors are supplied by Los Alamos National Laboratory and the Soviet Phobos prototype. These are to be carried aboard a gondola that supplies the data and supplies the power for the period of up to two weeks.

Sharp, William E.↗

Investigation of solar active regions at high resolution by balloon flights of the solar optical universal polarimeter, extended definition phase

Technical studies of the feasibility of balloon flights of the former Spacelab instrument, the Solar Optical Universal Polarimeter, with a modern charge-coupled device (CCD) camera, to study the structure and evolution of solar active regions at high resolution, are reviewed. In particular, different CCD cameras were used at ground-based solar observatories with the SOUP filter, to evaluate their performance and collect high resolution images. High resolution movies of the photosphere and chromosphere were successfully obtained using four different CCD cameras. Some of this data was collected in coordinated observations with the Yohkoh satellite during May-July, 1992, and they are being analyzed scientifically along with simultaneous X-ray observations.

Tarbell, Theodore D.↗

Processing parameters associated with scale-up of balloon film production

A method is set forth for assessing strain-rate profiles that can be used to develop a scale-up theory for blown-film extrusion. Strain rates are evaluated by placing four ink dots on the stalk of an extruded bubble to follow the displacements of the dots as a function of time. The instantaneous Hencky strain is obtained with the displacement data and plotted for analysis. Specific attention is given to potential sources of error in the distance measurements and corrections for these complex bubble geometries. The method is shown to be effective for deriving strain-rate data related to different processing parameters for the production of balloon film. The strain rates can be compared to frostline height, blow-up ratio, and take-up ratio to optimize these processing variables.

Simpson, D. M.↗

Early results from the MIT millimeter and sub-millimeter balloon-borne anisotropy measurement

The MIT balloon-borne bolometric search for Cosmic Microwave Background Radiation (CMBR) anisotropies places the most stringent constraints to date on fluctuations in the CMBR. Four maps of half of the Northern Hemisphere at 1.8, 1.1, 0.63 and 0.44 mm wavelength, have a beam size of 3.8 deg with a 1 sigma sensitivity of less than 0.1 mK (thermodynamic) per FOV in each of the first two channels. Analysis of the sky map at 1.8 mm wavelength using a likelihood ratio test for galactic latitudes of 15 deg and greater yields a 95 percent confidence level (CL) upper limit on fluctuations of the CMBR at DeltaT/T less than or equal to 1.6 x 10 exp -5 with a statistical power of 92 percent for Gaussian fluctuations at a correlation angle of 13 deg. Between 3 deg and 22 deg, the upper limit for fluctuations is DeltaT/T less than or equal to 4.0 x 10 exp -5 (95 percent CL).

Meyer, Stephan S.↗